• 제목/요약/키워드: LRB system

검색결과 73건 처리시간 0.026초

Seismic response variation of multistory base-isolated buildings applying lead rubber bearings

  • Islam, A.B.M. Saiful;Al-Kutti, Walid A.
    • Computers and Concrete
    • /
    • 제21권5호
    • /
    • pp.495-504
    • /
    • 2018
  • The possibility of earthquakes in vulnerable regions indicates that efficient technique is required for seismic protection of buildings. During the recent decades, the concept is moving towards the insertion of base isolation on seismic prone buildings. So, investigation of structural behavior is a burning topic for buildings to be isolated in base level by bearing device. This study deals with the incorporation of base isolation system and focuses the changes of structural responses for different types of Lead Rubber Bearing (LRB) isolators. A number of sixteen model buildings have been simulated selecting twelve types of bearing systems as well as conventional fixed-base (FB) scheme. The superstructures of the high-rise buildings are represented by finite element assemblage adopting multi-degree of freedoms. Static and dynamic analyses are carried out for FB and base isolated (BI) buildings. The dynamic analysis in finite element package has been performed by the nonlinear time history analysis (THA) based on the site-specific seismic excitation and compared employing eminent earthquakes. The influence of the model type and the alteration in superstructure behavior of the isolated buildings have been duly assessed. The results of the 3D multistory structures show that the lateral forces, displacement, inertia and story accelerations of the superstructure of the seismic prone buildings are significantly reduced due to bearing insertion. The nonlinear dynamic analysis shows 12 to 40% lessening in base shear when LRB is incorporated leading to substantial allowance of horizontal displacement. It is revealed that the LRB isolators might be potential options to diminish the respective floor accelerations, inertia, displacements and base shear whatever the condition coincides. The isolators with lower force intercept but higher isolation period is found to be better for decreasing base shear, floor acceleration and inertia force leading to reduction of structural and non-structural damage. However, LRB with lower isolator period seems to be more effective in dropping displacement at bearing interface aimed at reducing horizontal shift of building structure.

Variations in the hysteretic behavior of LRBs as a function of applied loading

  • Ozdemir, Gokhan;Bayhan, Beyhan;Gulkan, Polat
    • Structural Engineering and Mechanics
    • /
    • 제67권1호
    • /
    • pp.69-78
    • /
    • 2018
  • The study presented herein focused on the change in hysteretic force-deformation behavior of lead rubber bearings (LRBs). The material model used to idealize response of LRBs under cyclic motion is capable of representing the gradual attrition in strength of isolator unit on account of lead core heating. To identify the effect of loading history on the hysteretic response of LRBs, a typical isolator unit is subjected to cyclic motions with different velocity, amplitude and number of cycles. Furthermore, performance of an LRB isolated single degree of freedom system is studied under different seismic input levels. Finally, the significance of lead core heating effect on LRBs is discussed by considering the current design approach for base isolated structures. Results of this study show that the response of an LRB is governed strongly by the amplitude and number of cycles of the motion and the considered seismicity level.

라이즈 스팬 비에 의한 200m 허니컴 래티스 돔의 동적 응답 분석 (Dynamic Response Analysis of 200m Honeycomb Lattice Domes by Rise Span Ratio)

  • 박강근;정미자
    • 한국공간구조학회논문집
    • /
    • 제19권2호
    • /
    • pp.51-61
    • /
    • 2019
  • The objective of this study is to analysis the seismic response of 200m spanned honeycomb lattice domes under horizontal and up-down ground motion of El Centro earthquake. For the analysis of seismic response of the honeycomb lattice domes by rise/span ratio, the time history analysis is used for the estimation of the dynamic response. The low rise lattice dome is less deformed and less stressed than the high rise lattice dome for the earthquake ground motion. The 3-dimensional earthquake response is not significantly different the dynamic response of one directional ground motion. The earthquake response of domes with LRB isolation system is significantly reduced for the asymmetric vertical deformation and the horizontal and vertical accelerations.

사장교 케이블 댐퍼시스템 개발과 검증실험 (Development of Cable Damper System and Its Verification Test)

  • 서주원;김남식;서정인;정운
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.394-402
    • /
    • 2001
  • In order to lessen cable vibration, new cable damper system with high damping rubber was developed using the basis of the LRB design scheme. The analysis model of cable damper system incorporate voigt-kelvin damper model into the nonlinear cable analysis model. To achieve maximum damping capacity both reducing damper stiffness and developing high damping rubber were performed. As a result of verification test, the high damping rubber damper show its effectiveness in improving cable damping capacity.

  • PDF

스카이브릿지의 안전성확보를 위한 FPS 설계방법에 대한 연구 (Study of Structural Design Method of Friction Pendulum System for Fail Safe of a Sky-Bridge)

  • 김현수
    • 한국산학기술학회논문지
    • /
    • 제14권7호
    • /
    • pp.3502-3507
    • /
    • 2013
  • 스카이브릿지가 연결되는 건물에 강접합될 경우에는 비정형성이 크게 되어 지진하중에 매우 불리하게 거동할 수 있다. 따라서, 마찰진자베어링(FPS)이나 납고무베어링(LRB)와 같은 연결시스템을 사용하여 스카이브릿지와 구조물을 연결하게 된다. 이러한 연결시스템은 큰 지진하중이 발생하였을 때 스카이브릿지가 연결된 건물에서 분리되어 낙교하지 않도록 신중하게 설계되어야 한다. 본 논문에서는 수직방향 인장력에대해서 저항성이 없는 마찰진자감쇠기를 이용한 연결시스템을 설계하는 과정에서 반드시 검토해야할 사항을 분석하였다. 이를 위하여 실제 시공된 누리꿈 스퀘어를 예제구조물로 선택하였고 예상되는 지진하중이 가해졌을 때 스카이브릿지 연결시스템에서 발생하는 응답을 분석하여 낙교를 방지할 수 있는 설계 프로세스를 정립하였다.

납 면진받침을 적용한 건축물의 내진 설계 (Seismic Design of Building Using LRB(Lead Rubber Bearing))

  • 김두훈
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1998년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Spring 1998
    • /
    • pp.258-265
    • /
    • 1998
  • Seismic isolation has developed to the point where it may be considered as a viable design alternate for a wide range of building structures. However, it needs to consider various aspects to adopt a suitable isolation system for buildings practically. This report presents the basis for the preliminary design procedure which has been developed for the seismic isolation system using the lead rubber bearings. The design procedures have been developed to ensure that the bearings will safely support the maximum gravity load throughout the life of the structure while they provide a period shift and hysteretic damping during the design earthquake.

  • PDF

LRB를 이용한 병렬전단벽 구조물의 지진응답제어 (Seismic Responses Control of Coupled Shear Wall Structures Using LRBs)

  • 박용구;김현수;고현;김민균;이동근
    • 한국지진공학회논문집
    • /
    • 제14권6호
    • /
    • pp.1-9
    • /
    • 2010
  • 대부분의 전단벽 구조물은 통로의 목적으로 개구부를 필요로 하게 되고 전단벽들 사이가 슬래브나 연결보로 연결된 병렬 전단벽의 형태를 띠게 된다. 이러한 구조물에 지진하중이 작용할 때 연결보에 과도한 전단력이 작용하여 연결보가 취성적으로 파괴되거나 전단벽이 먼저 항복하는 문제점이 발생할 수 있다. 이를 방지하기 위하여 연결보에 감쇠장치를 설치하게 되면 구조물의 진동제어효과와 더불어 연결보의 응력집중 및 취성적 파괴를 막을 수 있어서 내진성능 향상을 기대할 수 있다. 본 논문에서는 병렬전단벽 연결보 중앙부에 LRB (Lead Rubber Bearing)가 설치된 구조물의 지진응답제어효과 및 응력의 분포를 평가하여 구조적 효율성을 확인하고자 한다. 이를 위하여 병렬전단벽의 거동을 비교적 정확하게 모사할 수 있는 모형화 방법을 제안하였고, 제안된 모형화 방법을 통하여 지진하중을 받는 예제 병렬구조물에 대한 시간이력해석을 수행한 후 지진응답제어성능을 검토하였다.

LRB 면진장치를 적용한 원전구조물의 지진응답에 따른 확률론적 연구 (A Probabilistic Study on Seismic Response of Seismically Isolated Nuclear Power Plant Structures using Lead Rubber Bearing)

  • 김현정;송종걸;문지호
    • 한국지진공학회논문집
    • /
    • 제22권2호
    • /
    • pp.45-54
    • /
    • 2018
  • The seismically isolated nuclear power plants shall be designed for design basis earthquake (DBE) and considered to ensure safety against beyond design basis earthquake (BDBE). In order to limit the excessive displacement of the seismic isolation system of the seismically isolated structure, the moat is installed at a certain distance from the upper mat supporting the superstructure. This certain distance is called clearance to stop (CS) and is calculated from the 90th percentile displacement of seismic isolation system subjected to BDBE. For design purposes, the CS can be obtained simply by multiplying the median displacement of the seismic isolation system against DBE by scale factor with a value of 3. The DBE and BDBE used in this study were generated by using 30 sets of artificial earthquakes corresponding to the nuclear standard design spectrum. In addition, latin hyper cube sampling was applied to generate 30 sets of artificial earthquakes corresponding to maximum - minimum spectra. For the DBE, the median displacement and the 99th percentile displacement of the seismic isolation system were calculated. For the BDBE, the suitability of the scale factor was assessed after calculating the 90th percentile displacement of the seismic isolation system.

E-Shape 강재이력댐퍼의 수치모델과 기초격리구조물의 지진응답 (A Study on Base Isolation Performance and Phenomenological Model of E-Shape Steel Hysteretic Damper)

  • 황인호;주민관;심종성;이종세
    • 대한토목학회논문집
    • /
    • 제28권5A호
    • /
    • pp.685-690
    • /
    • 2008
  • 최근 대규모의 지진피해로 인해 내진설계에 대한 관심이 높아지면서, LRB(Lead Rubber Bearing), FPS(Friction Pendulum System) 등 다양한 지진격리장치에 대한 연구가 진행되고 있다. 본 연구에서 E-Shape 강재이력댐퍼를 이용한 지진격리장치의 성능 평가를 위해 E-Shape 댐퍼의 동적거동 실험을 수행하였으며, 이를 바탕으로 해석적 연구를 위한 수치모델을 제안하였다. 또한, 제안된 E-Shape 강재이력댐퍼의 수치모델을 6자유도를 가진 5층 건물에 적용하여 LRB 시스템과 이력거동을 비교하여 지진격리성능 평가를 수행하였다. 본 연구를 통하여 제안된 수치모델은 실제 E-Shape 강재이력댐퍼의 동적거동을 적절히 묘사할 수 있으며, E-Shape 강재이력댐퍼는 비선형 거동을 통한 에너지를 적절히 소산시킴으로서 기존 시스템과 비교하여 충분히 지진격리성능을 발휘할 수 있을 것으로 사료된다.

Effects of the isolation parameters on the seismic response of steel frames

  • Deringol, Ahmet H.;Bilgin, Huseyin
    • Earthquakes and Structures
    • /
    • 제15권3호
    • /
    • pp.319-334
    • /
    • 2018
  • In this paper, an analytical study was carried out to propose an optimum base-isolated system for the design of steel structures equipped with lead rubber bearings (LRB). For this, 5 and 10-storey steel moment resisting frames (MRFs) were designed as Special Moment Frame (SMF). These two-dimensional and three-bay frames equipped with a set of isolation systems within a predefined range that minimizes the response of the base-isolated frames subjected to a series of earthquakes. In the design of LRB, two main parameters, namely, isolation period (T) and the ratio of strength to weight (Q/W) supported by isolators were considered as 2.25, 2.5, 2.75 and 3 s, 0.05, 0.10 and 0.15, respectively. The Force-deformation behavior of the isolators was modelled by the bi-linear behavior which could reflect the nonlinear characteristics of the lead-plug bearings. The base-isolated frames were modelled using a finite element program and those performances were evaluated in the light of the nonlinear time history analyses by six natural accelerograms compatible with seismic hazard levels of 2% probability of exceedance in 50 years. The performance of the isolated frames was assessed in terms of roof displacement, relative displacement, interstorey drift, absolute acceleration, base shear and hysteretic curve.