• Title/Summary/Keyword: LPG Pressure Regulator

Search Result 13, Processing Time 0.016 seconds

A Study on the Strength Safety of a Gas Valve (가스밸브의 강도안전성에 관한 연구)

  • Kim, Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.1
    • /
    • pp.60-63
    • /
    • 2018
  • This paper presents the FEM analysis results on the strength safety of a gas valve for a LPG cylinder. Based on the FEM analysis, the maximum von Mises stress on the boundary zone between a safety valve and the upper area of the thread is 99.2 MPa for the supplied gas pressure of 3.5 MPa in which the gas valve is fully opened. The maximum von Mises stress of 99.2 MPa is considered as safety value, because that value is lower than the yield stress of a brass material. In this case, the maximum deformation at the upper right part of the pressure regulator is 0.002mm. The maximum deformation zone is not a meaning part of the sealing part such as an O-ring or a diaphragm of a gas valve and a pressure regulator. The proposed hybrid gas valve model in which is integrated with a conventional cut-off valve and a pressure regulator is recommended as a gas leakage free mechanism and minimized compact size for a LPG cylinder.

Evaluation of Service Life of Low Pressure LP-Gas Regulators for Home Use (가정용 LPG 저압조정기의 사용수명 평가)

  • Kim Young-Gyu;Kim Pil-Jong;Cho Seok-Beom;Kwon Boo-Kil
    • Journal of the Korean Institute of Gas
    • /
    • v.9 no.3 s.28
    • /
    • pp.44-48
    • /
    • 2005
  • Experimental works were carried out to evaluate the service life of low pressure LPG regulators for domestic use. Experimental results showed that the operating pressure of regulators used for 7 years notably deviated from the standard value of the adjusting pressure and the lock-up pressure. Thus, it is estimated that low pressure LPG regulators have approximately 6 years of service life.

  • PDF

Evaluation of Performance and Service Life of Low Pressure LPG Regulators for Home Use (가정용 LP가스 저압조정기의 성능 및 수명 평가)

  • Kim Young-Gyu;Cho Seok-Beom;Kim Pil-Jong
    • Journal of Energy Engineering
    • /
    • v.15 no.1 s.45
    • /
    • pp.23-27
    • /
    • 2006
  • This paper presents the evaluation of LPG (Liquefied petroleum gas) regulators for home use. For the evaluation, several properties of the regulators were experimentally analyzed, such as the operation of safety device, the adjusting and lock-up pressure, the adjusting spring and the diaphragm, with respect to the used time of the regulators. Experimental results showed that the initial operation performance of regulators were degraded with increase of the service time and also showed that the degradation of the performance and material property could become serious after six-year-use of the regulator.

Aging Characteristics of Low Pressure LPG Regulators for Domestic Use (가정용 LPG 저압조정기의 경년특성에 관한 연구)

  • Kim Young-Gyu;Kwon Jeong-Rock
    • Journal of the Korean Institute of Gas
    • /
    • v.3 no.1
    • /
    • pp.58-63
    • /
    • 1999
  • Experimental works were carried out to evaluate how the lapse of time affects the performance characteristics and the service life of low pressure LPG regulators for domestic use. Experimental results showed that the operating pressure of safety devices deviated from the opening pressure value and the closing pressure value from just 1 year after service, and the operating pressure of regulators used for 7${\~}$8 years notably deviated from the reference value of the adjusting pressure and the closing pressure. And the material properties of springs and diaphragms deteriorated after 5${\~}$6 years of service. Thus, it is estimated that low pressure LPG regulators have approximately 6 years of service life. However, it is highly recommended that regulators exceeding 5 years of service should be replaced for the safety of consumer and accident prevention even if they are operating normally.

  • PDF

Evaluation of Performance and Service Life of Low Pressure LPG Regulators for Home Use

  • Kim Young-Gyu;Cho Seok-Beom;Kim Pil-Jong;Kwon Boo-Kil
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.329-334
    • /
    • 2006
  • This paper presents the evaluation of LPG (Liquefied petroleum gas) regulators for home use. For the evaluation, several properties of the regulators were experimentally analyzed, such as the operation of safety device, the adjusting and lock-up pressure, the adjusting spring and the diaphragm, with respect to the used time of the regulators. Experimental results showed that the initial operation performances of regulators were degraded with increase of the service time and also showed that the degradation of the performance and material property could become serious after about six-year-use of the regulators.

Study for Fire Examples of LPG Leakage Including Fuel hose, Injector and Pressure Regulator Connector in Vehicle (자동차 연료호스, 인젝터 및 압력조절기 연결부에서 LP 가스 누출에 의한 화재사례 고찰)

  • Lee, Il Kwon;Kook, Chang Hoo;Suh, Moon Won;Jung, Dong Hwa
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.3
    • /
    • pp.8-13
    • /
    • 2013
  • The purpose of this paper is to study for fire example by fuel leakage in LPG Vehicle. At first example, the car was repaired the fuel line that was connected with pressure hose between fuel regulator and injector in engine. But the service man was not very tighten with regular torque. At a result, the gas leaked on hot parts of engine. It verified the production of fire by engine heat. At second example, when the repair man, after replacement the injector, inserted the injector in a assembling part of it, he didn't the transform condition of fixing part. Therefore, the tearing phenomenon of O ring producted the controlled leakage of fuel by the injector deflection. It found the fact that the fuel leaked with gap of O ring. At third example. the fuel-cut solenoid valve was lined with pressure regulator unit. But the service man didn't throughly certify the leaked work of connected parts after repaired it. As a result, it certified the fire by engine heating leaked liquefied petroleum gas. Therefore it have to minimize the fire production that the driver should do no problem to throughly manage the fuel system.

Overpressure Prevention of Pipeline Attached to Outlet of LPG Vaporizer (온수전열식 기화기 후단 배관내 가스의 이상압력상승 방지방안에 관한 연구)

  • Park Kyo-Shik;Park Heui-Joon;Kim Ji-Yoon
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.2 s.14
    • /
    • pp.62-68
    • /
    • 2001
  • Overpressure in pipeline attached to outlet of LPG vaporizer has been studied to provide countermeasures to prevent it. The cause of liquefaction in pipeline was reviewed using vapor pressure curve with temperature, pressure, and composition to suggest method of controlling such parameters. Performance of vaporizer has been tested to detect defective design of float ball, and then improved scheme was suggested. Trouble of regulator attached to vaporizer was also studied to give countermeasures.

  • PDF

A Study on the Natural Evaporation Capacity of LPG Container (액화석유가스 용기의 자연 증발량에 관한 연구)

  • Jo Young-Do;Kim Ji-Yoon
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.2 s.14
    • /
    • pp.22-29
    • /
    • 2001
  • The number of gas containers and the period of exchanging gas containers are vsy important in designing liquefied petroleum gas(LPG) supply system for small capacity domain. And also the evaluation of remaining LPG in containers to be exchanged is very useful information in commerce. However seldon has been studied on calculating method about those with respect to gas consumption pattern. In this study, a simulation method was developed to estimate the evaporation capacity of LPG container, the mass gas flow rate from LPG container, the temperature and vapor pressure of LPG, and the remained LPG at containers to be exchange by using LPG property equations, mass balance equation, and heat balance equation. The simulation results were correlated well with experimental data. The overall heat transfer coefficient from air to LPG is approximately $9{\~}13 kcal/m^2{\cdot}hr{\cdot}^{\circ}C$ and does not strongly affect on the evaporation capacity of LPG container. The mass gas flow rate from LPG container is constant when the vapor pressure of LPG is within pressure regulator's control range. While, out of range, it suddenly reduce to a evaporation rate which is balanced with heat transfer from air. The evaporation capacity of LPG container increased with surrounding temperature and the composition of propane, and decreased drastically with continuous gas consumption. The number of gas containers divided the number of houses using gas supply system was reduced by using automatic gas feeding device.

  • PDF

LPG Cylinder Leak Experiment from Multiple Leak Scenarios (누출종류에 따른 LP가스용기 누출량 실증 실험)

  • Lee, Minkyung;Lee, Kang-Ok;Kim, Young Gyu
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.6
    • /
    • pp.61-66
    • /
    • 2019
  • Unlike NG supplied through pipes, LPG is mainly used for independent storage of cylinders or small storage tanks. As LPG is widely used in islands and underdeveloped areas, accidents due to neglect of safety management are high. Houses and businesses that have LPG accidents are likely to be damaged due to relatively high population density. Therefore, the necessity of strengthening the safety management of LPG is constantly raised. Accordingly, in 1996, Korea Gas Safety Corporation conducted an LPG leak test. In this study, based on the 96-year experiment, the gas leakage measurement of LPG vessels was conducted by adding several conditions such as outside temperature and pipe condition. Through this, the trend of leakage for various scenarios of LPG leakage was examined. In the case of a gas leak, when the article which may affect the pressure such as a regulator is not connected, the leakage amount is greatly changed by the outside air temperature, and when the regulator is fastened, the influence of the outlet pressure is large. It is expected that the experiment can be used as basic data for determining gas accidents and leakages that may occur later.