• 제목/요약/키워드: LOI

검색결과 234건 처리시간 0.029초

BIM기반 플로팅 공공시설 설계단계별 정보설정에 관한 연구 (A Study of BIM level of design process information for floating public facilities)

  • 전기형;정원조;홍순연;김정길
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2013년도 추계학술대회
    • /
    • pp.295-296
    • /
    • 2013
  • 플로팅건축은 기존 육상의 건축과 달리 다양한 주체와 복잡한 협업이 이루어지므로, 분야별, 단계별 협업에서 프로젝트 참여자들간의 긴밀한 의사소통이 요구되어 진다. 효율적인 정보관리를 위해 국내 외에서 이용되고 있는 BIM(Building Information Modeling)을 활용하면 플로팅건축 프로젝트의 효율적인 진행을 가능하게 한다. 설계프로세스별 정보수준에(LOI) 관한 기준을 정의함으로써 BIM기반 통합설계프로세스 진행시 단계별 적합한 정보를 제공하도록 하였다.

  • PDF

자외선 경화형 인계 단량체를 이용한 면직물의 방염가공 (Flame-retardant Finish of Cotton Fabrics Using UV-curable Phosphorous-containing Monomers)

  • 장진호;정용균
    • 한국염색가공학회지
    • /
    • 제20권4호
    • /
    • pp.8-14
    • /
    • 2008
  • Flame-retardant cotton fabrics were prepared by UV curing of photocurable aqueous formulations of phosphorous-containing methacrylate monomers and 2-hydroxy-2-methyl-1-phenyl-1-propanone as flame retardants and a photoinitiator respectively, which is an environmentally friendly and energy-saving process. The characterization of the UV-coated cotton fabric was made by ATR, TGA and limited oxygen index measurement. UV cured coating onto cotton fabrics reduced the first thermal decomposition temperature and mass loss as well as increase in the amount of char residue compared with the untreated cotton fabric presumably due to modified thermal decomposition process. The LOI values up to 28.5 and 27.2 were obtained by the UV curing of MMEP and TMEP respectively. The treatment was durable to five laundering cycles, which was more prominent in the case of trifunctional TMEP treatment.

PUB 분말이 충전된 혼합폐플라스틱/$Mg(OH)_{2}$ 복합소재의 난연성 및 기계적 특성 (Flame Retardancy & Mechanical Properties of Mixed Waste $Plastic/Mg(OH)_{2}$ Composites Reinforced with PUB Powder)

  • 정기창;송종혁
    • 한국안전학회지
    • /
    • 제21권1호
    • /
    • pp.65-71
    • /
    • 2006
  • Flame retardancy and mechanical properties of polyolefinic mixed waste plastics/filler composites were investigated by using inorganic flame retardant(magnesium hydroxide) and PUB(polyurethane block) powder generated from cryogenic insulation process. All composites were obtained by extrusion and after compression molding. The effect of PUB powder on the properties of the composites was studied by tensile and izod impact test, morphology studies and flammability as LOI and UL94 vertical burning test and smoke density. The objective of this work is to obtain good mechanical properties from recycled PP composites with $Mg(OH)_{2}/PUB$ powder as fillers and optimum cost-performance balance, in addition to flame retardant characteristics.

POFA를 혼입한 시멘트 페이스트의 유동특성에 폴리카르본산계 감수제가 미치는 영향에 관한 실험적 연구 (An Experimental Study on the Effects of Polycarboxylate Superplasticizer on the Fluidity Properties of Cement Pastes with POFA)

  • 위광우;정성민;이윤수;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.137-138
    • /
    • 2016
  • Palm Oil Fuel Ash(POFA),which is burned in palm oil factories to get energy and gathered, has been studied in many countries due to its chemical properties. However POFA has high value of LOI and lots of pores on its particle surface. Therefore, in this study, POFA's fluidity were confirmed by mini-slump test and plastic viscosity test. Through the results, fluidity of POFA reduced according to the replacement ratio of POFA because of high value of LOI and its pores on surface and plastic viscosity of POFA increased. In addition, when superplasticizer was added, fluidity increased due to the steric effect of polycarboxylate superplasticizer.

  • PDF

THE PARTICLE SIZE EFFECT ON COMBUSTION BEHAVIOR OF CELLULOSE INSULATION

  • Choi, Jeong-Hwa;Kim, Hong;Ryu, Kyong-Ok
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.185-192
    • /
    • 1997
  • The combustion of cellulose insulation treated with Borax, Boric acid and Aluminum Sulfate as combustion retardants is examined by candle type combustion tester. The cellulose fibers in cellulose insulation are classified by diameter as less than 0.2mm, 0.2mm-0.5mm, 0.5mm-2mm and more than 2mm. The burning behavior of cellulose insulation are studied by LOI (Limit Oxygen Index: Beginning point of smoldering), L- point (Lower point of combustion transition from smoldering- flaming to flaming combustion), LOI, L-point and H-point rise with the increasing particle size of cellulose fibers because thermal decomposition rate of cellulose fiber decreases. The phenomena of combustion transition from smoldering to flaming combustion are determined by the generating rate of combustible gas and the formation rate of combustible gas mixture within the zone of cellulose fiber heated.

  • PDF

방염스티로폴 약제 개발과 방염판넬 생산시 물성에 관한 연구 (Studies on the Synthesis of Diphenylphenylamidophosphate for Flame retandant agents of EPS and It's the effect of Flame Retardandy and properties in panel production)

  • 이광우
    • 한국산업융합학회 논문집
    • /
    • 제4권2호
    • /
    • pp.185-191
    • /
    • 2001
  • Diphenylpropylamidophosphate(DPPAP) was synthesized as flame retardant for Expanded Polystyrene(EPS). Structure of DPPAP was investigated by the m, NMR, DSC. We make FR panels with EPS beads which treated with DPPAP and expanded by expand machines. FR panels were used in this study after formation by form machines and then cutting by cutting machines. The following conclusions were obtained: 1. The new synthetic agent was developed without the use of solvent such as pyridine or tertiary amine in the synthesis of DPPAP which served as flame retardant for EPS. 2. The flame retandancy effect of EPS treated with DPPAP was found excellent in LOI tests. 3. The properties of FR EPS panels treated with DPPAP did not difference.

  • PDF

유교가 베트남에서 국가이념으로 성립되는 과정 (The Road to Confucianism as a State Ideology in Vietnam)

  • 유인선
    • 수완나부미
    • /
    • 제3권1호
    • /
    • pp.1-23
    • /
    • 2011
  • This paper traces the process how Confucianism was established as a state ideology in Vietnam. Confucianism is said to have first been introduced into Vietnam around the early 3rd century. However, it had been outshone by Buddhism until the 1389s when Ho Quy Ly rose to power and emphasized pre-Qin Confucianism. In 1428, Lê Loi founded a new dynasty and changed the state ideology from Buddhism to Confucianism. Despite this radical shift, however, Confucianism was not firmly established at the beginning of the Lê Dynasty. It was Lê Thanh Tong (1460-1497) who fully established neo-Confucianism as the state ideology. The reason was that he devoted himself to the study of Confucian texts from a young age and sought to strengthen his own royal authority by emphasizing the neo-Confucian concept of loyalty and filial piety.

  • PDF

옥외 광고물 소재의 연소특성 평가 (Evaluation of Combustion Characteristics of Outdoor Advertisement Materials)

  • 엄상용;김경진;이수경
    • 한국화재소방학회논문지
    • /
    • 제26권5호
    • /
    • pp.79-84
    • /
    • 2012
  • 상층 및 인접건물로의 연소확대 위험성이 있는 옥외 광고물 소재의 연소특성을 평가하였다. 본 연구에서는 UL 94와 ASTM D 2863에 따라 난연성과 한계산소지수를 평가하였다. 난연성 평가결과, 포멕스가 V-0의 높은 난연성을 보이는 반면 다른 시료들에서는 등급외의 난연성을 보였다. 한계산소지수 평가 결과에서도 포멕스의 한계산소지수가 가장 높았다. ISO 5660-1에 따라 콘칼로리미터를 이용하여 연소특성을 평가하였으며, 콘칼로리미터 시험결과 옥외 광고물 소재들은 화재확대 예방에 취약하다는 것을 알 수 있었다. 플렉스의 착화시간이 가장 빨랐으며, 특히 아크릴판은 최대 열방출율 뿐만 아니라 총 방출열량 또한 다른 소재들에 비해 높았다.

연속추출법을 이용한 사격장 오염토양 중 중금속의 화학적 형태 결정 (The Determination of Chemical Forms of Heavy Metals in Shooting Area Contaminated Soil Using Sequential Extraction Method)

  • 문경혜;박홍기;유경근;;;김주엽
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제20권6호
    • /
    • pp.111-116
    • /
    • 2015
  • The soil sample obtained from shooting area contaminated with Pb, Cu, and Zn was investigated to determine the chemical forms of heavy metals with Tessier’s sequential extraction method, which is constituted of five fractions such as ‘exchangeable’, ‘bound to carbonate’, ‘bound to oxide’, ‘bound to organic matter’, and residual fractions. The amount of organic matter was measured by loss on ignition (LOI) and then the results of ‘bound to organic matter’ and LOI were compared. The sequential extraction results show that 4.7%-45% of Pb, 6.2%-25.9% of Cu and 3.9%-15.3% of Zn belong to the ‘bound to organic matter’ fraction, but LOI result shows that only 1.0%-2.8% of organic matter exists in the soil sample. In heavy medium separation tests, because Pb and Cu extracted in ‘bound to organic matter’ and residual fractions were removed, the heavy metals in the fractions would exist as heavier forms. These results suggest that the part of heavy metal extracted in ‘bound to organic matter’ fraction would result from the oxidation of metallic forms by hydrogen peroxide and nitric acid used in the fraction, and, consequently, that the ‘bound to organic matter’ fraction should be investigated in detail to determine the removal method and treatment capacity when the Tessier’s sequential extraction method is used to examine heavy metal contaminants resulted from elemental metal like bullets.

인과 염소 함유 변성폴리에스테르와 APT-Trimer에 의한 PU 난연도료의 제조 및 도막물성 (Preparation and Physical Properties of PU Flame-Retardant Coatings Using Modified Polyester Containing Phosphorus/Chlorine and APT-Trimer)

  • 박홍수;조혜진;심일우;함현식;김승진;성기천
    • 한국응용과학기술학회지
    • /
    • 제22권3호
    • /
    • pp.270-280
    • /
    • 2005
  • To maximize a synergy effect in flame-retardancy of flame-retardant coatings, phosphorus and chlorine were introduced in polymer chains. Two-components PU flame-retardant modified polyesters (ABTTC-10C, -20C, -30C) were prepared by curing, at room temperature, of isocyanate (allophanate-trimer) and prepared modified polyesters which contain phosphorus and chlorine. To examine the film properties of the prepared flame-retardant coatings, film specimens were prepared with the prepared coatings. The film properties of ABTTC, ABTTC-10C and ABTTC-20C, which contain 0, 10 and 20wt%, 2,4-dichlorobenzoic acid (2,4-DCBA), respectively, were proved to be good, whereas the film properties of ABTTC-30C, which contains 30wt% 2,4-DCBA, were proved to be a little bit poor. Two kinds of flame retardancy tests, $45^{\circ}$Meckel burner method and LOI method, were performed. With the $45^{\circ}$Meckel burner method, three flame-retardant coatings except ABTTC showed less than 3.4 cm of char length, and showed less than 2 seconds of afterflaming and afterglow. From this result, the prepared flame-retardant coatings were proved to have the 1st grade flame retardancy. With the LOI method, the LOI values of the coatings containing more than 10wt% 2,4-DCBA were higher than 30wt%, which means that the coatings possess good flame-retardancy. From these results, it was found that synergistic effect in flame-retardancy was taken place by the introduced phosphorus and chlorine.