• Title/Summary/Keyword: LOCK OUT

Search Result 160, Processing Time 0.031 seconds

Analysis of Fault Current Limiting Characteristics According to Variation of Inductances in Separated Three-phase Flux-lock Type SFCL (분리된 삼상자속구속형 전류제한기의 인덕턴스 변화에 따른 전류제한 특성 분석)

  • Doo, Seung-Gyu;Du, Ho-Ik;Kim, Min-Ju;Park, Chung-Ryul;Kim, Yong-Jin;Lee, Dong-Hyeok;Han, Byoung-Sung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.6
    • /
    • pp.522-525
    • /
    • 2009
  • We investigated the fault current characteristics of the separates three-phase flux-lock type superconducting fault current limiter(SFCL) according to the variation of inductances. The single-phase flux-lock type SFCL consists of two coils. The primary coil is wound in parallel to the secondary coil on an iron core. And superconductor is series connected on secondary coil. Superconductor is using the YBCO coated conductor. The separated three-phase flux-lock type SFCL consists of single-phase flux-phase type SFCL in each phase. To analyze the current limiting characteristics of a three-phase flux-lock type SFCL, the short circuit experiments were carried out fault such as the triple line-to-ground fault. The experimental result shows that fault current limiting characteristics of additive polarity winding was better than subtractive polarity winding and when the inductances of coil 2 was lower, resistances of YBCO CC was more generated.

A Fast Locking Dual-Loop PLL with Adaptive Bandwidth Scheme (루프 대역폭 조절기를 이용한 빠른 위상 고정 시간을 갖는 이중 루프 위상고정루프)

  • Song, Youn-Gui;Choi, Young-Shig
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.5
    • /
    • pp.65-70
    • /
    • 2008
  • A novel fast locking dual-loop integer-N phase locked loop(PLL) with adaptive bandwidth scheme is presented. When the PLL is out-of-lock, bandwidth becomes much wider than 1/10 of channel spacing with the wide bandwidth loop. When the PLL is near in-lock, bandwidth becomes narrower than 1/10 of channel spacing with the narrow bandwidth loop. The proposed PLL is designed based on a $0.35{\mu}m$ CMOS process with a 3.3V supply voltage. Simulation results show the fast look time of $50{\mu}s$ for an 80MHz frequency jump in a 200KHz channel spacing PLL with almost 14 times wider bandwidth than the channel spacing.

Analysis on Power Burden of HTSC Module due to Fault Current's Amplitude of a Flux-Lock Type SFCL with Two Triggering Currents (두 트리거 전류를 갖는 자속구속형 초전도한류기의 고장전류 크기에 따른 초전도 모듈의 전력부담 분석)

  • Han, Tae-Hee;Lim, Sung-Hun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.7
    • /
    • pp.424-428
    • /
    • 2016
  • In this paper, the power burden of High-TC superconducting (HTSC) module comprising the flux-lock type superconducting fault current limiter (SFCL) with two triggering currents during the fault period was analyzed. The short-circuit tests for the simulated power system with the SFCL in the different fault positions, which were expected to affect the amplitude of the fault current, were carried out. Through the comparative analysis on the power burden of the HTSC modules, the proposed flux-lock type SFCL was confirmed to be effective to divide into two power burdens according to the amplitude of the fault currents.

An historical analysis on the carbon lock-in of Korean electricity industry (한국 전력산업의 탄소고착에 대한 역사적 분석)

  • Chae, Yeoungjin;Roh, Keonki;Park, Jung-Gu
    • Journal of Energy Engineering
    • /
    • v.23 no.2
    • /
    • pp.125-148
    • /
    • 2014
  • This paper performs a historical analysis on the various factors contributing to the current carbon lock-in of Korean electricity industry by using techo-institutional complex. The possibilities of the industry's carbon lock-out toward more sustainable development are also investigated. It turns out that market, firm, consumer, and government factors are all responsible for the development of the carbon lock-in of Korean power industry; the Korean government consistently favoring large power plants based on the economy of scale; below-cost electricity tariff; inflation policy to suppress increases in power price; rapid demand growth in summer and winter seasons; rigidities of electricity tariff; and expansion of gas-fired and imported coal-fired large power plants. On the other hand, except for nuclear power generation and smart grid, environment laws and new and renewable energy laws are the other remaining factors contributing to the carbon lock-out. Considering three key points that Korea is an export-oriented economy, the generation mix is the most critical factor to decide the amounts of carbon emission in the power industry, and the share of industry and commercial power consumption is over 85%, it is unlikely that Korea will achieve the carbon lock-out of power industry in the near future. Therefore, there are needs for more integrated approaches from market, firm, consumer, and government all together in order to achieve the carbon lock-out in the electricity industry. Firstly, from the market perspective, it is necessary to persue more active new and renewable energy penetration and to guarantee consumer choices by mitigating the incumbent's monopoly power as in the OECD countries. Secondly, from the firm perspective, the promotion of distributed energy system is urgent, which includes new and renewable resources and demand resources. Thirdly, from the consumer perspective, more green choices in the power tariff and customer awareness on the carbon lock-out are needed. Lastly, the government shall urgently improve power planning frameworks to include the various externalities that were not properly reflected in the past such as environmental and social conflict costs.

Current Limiting Characteristics According to the Increase of Voltage in Separated Three-Phase Flux-Lock Type Superconducting Fault Current Limiter Using YBCO CC (YBCO CC를 이용한 분리된 삼상 자속구속형 고온초전도 전류제한기의 전압 증가에 따른 전류제한 특성)

  • Doo, Seung-Gyu;Du, Ho-Ik;Kim, Min-Ju;Kim, Yong-Jin;Lee, Dong-Hyeok;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.355-356
    • /
    • 2009
  • In this paper, we investigated the fault current limiting characteristics according to the increase of voltage in the separates three-phase flux-lock type high-Tc superconducting fault current limiter using YBCO CC. The separated three-phase flux-lock type SFCL consists of single-phase flux-phase type SFCL in each phase. Superconductor was using the YBCO CC. To analyze the current limiting characteristics of a three-phase flux-lock type SFCL, the short circuit experiments were carded out fault such as the triple line-to-ground fault. The experimental result shows that fault current limiting characteristics was improved on the high voltage level.

  • PDF

A study on the relationship between 'Lock, Door and Axis' with the principal of following to the 'Tip, Root and Middle qi' (관합추(關闔樞)와 표본중기(標本中氣) 종화규율(從化規律)의 상관성(相關性)에 관한 연구(硏究))

  • Lee, Sang-Hyup
    • Journal of Korean Medical classics
    • /
    • v.26 no.4
    • /
    • pp.95-103
    • /
    • 2013
  • Objective : I would like to study the relationship between the theory of 'Lock, Door and Axis' with the principal of following to the 'Tip, Root and Middle qi' in Huang-Di-Nei-Jing. It can be analysed from the relativeness among the sentences to appearing in Shang-Han-Lun. And consider the theoretical relationship of the two books. Method : First, I search out the exact meaning of 'Lock, Door and Axis' theory. Second, The principal of following to the 'Tip, Root and Middle qi' is closely associated with 'Lock, Door and Axis' theory. Third, I would like to prove that the several sentence in the Shang-Han-Lun are closely related to the Huang-Di-Nei-Jing. Result : Zhang Zhong-jing's Shang-Han-Lun quote a theoretical basis in the Huang-Di-Nei-Jing. Furthermore, it extensively quote to explan a disease and treatment, and so on. Conclusion : It is necessary to study hard the Huang-Di-Nei-Jing for understand clearly the sentences of Shang-Han-Lun. I think that Huang-Di-Nei-Jing have a decisive effect on the Zhang Zhong-jing's thinking to the disease and his medical theory.

Analysis of Fault Current Limiting Characteristics According to Variation of Fault Current level in Integrated Three-Phase Flux-Lock Type Superconducting Fault Current Limiting (사고전류 변화에 따른 일체화된 삼상자속구속형 고온초전도 사고전류제한기의 사고전류 제한 특성 분석)

  • Han, Byoung-Sung;Park, Chung-Ryul;Du, Ho-Ik;Choi, Hyo-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.39-40
    • /
    • 2007
  • The analysis of fault current limiting characteristics according to variation of fault current level in the integrated three-phase flux-lock type superconducting fault current limiter (SFCL), which consisted of three-phase flux-lock reactor wound on an iron core with the same turn's ratio between coil 1 and coil 2 for each single phase, was performed. To analyze the current limiting characteristics of this integrated three-phase flux-lock type SFCL, the short circuit experiments was carried out the various three-phase faults such as the single line-to-ground fault, the double line-to-ground fault, the triple line-to-ground fault. From the experimental results, the fault current limiting characteristic was improved according to increase of fault current level.

  • PDF

Lock-on Characteristics of Wake Behind a Rotationally Oscillating Circular Cylinder (주기적으로 회전진동하는 원주 후류의 공진특성에 관한 연구)

  • Lee, Jung-Yeop;Lee, Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.8 s.239
    • /
    • pp.895-902
    • /
    • 2005
  • Lock-on characteristics of flow around a circular cylinder oscillating rotationally with a relatively high forcing frequency have been investigated experimentally. Dominant governing parameters are Reynolds number (Re), angular amplitude of oscillation (${\theta}_A$), and frequency ratio $F_R=f_f/f_n,\;where\;f_f$ is a forcing frequency and $f_n$ is a natural frequency of vortex shedding. Experiments were carried out under the conditions of $Re=4.14{\times}10^3,\;{\pi}/90{\leq}{\theta_A}{\leq}{\pi}/3,\;and\;F_R=1.0$. The effect of this active flow control technique on the lock-on flow characteristics of the cylinder wake was evaluated with wake velocity measurements and spectral analysis of hot-wire signals. The rotational oscillation modifies the flow structure of near wake significantly. The lock-on phenomenon always occurs at $F_R=1.0$, regardless of the angular amplitude ${\theta}_A$. In addition, when the angular amplitude is less than a certain value, the lock-on characteristics appear only at $F_R=1.0$,. The range of lock-on phenomena expands and vortex formation length is decreased, as the angular amplitude increases. The rotational oscillation create a small-scale vortex structure in the region just near the cylinder surface. At ${\theta}_A=60^{\circ}$, the drag coefficient was reduced about $43.7\%$ at maximum.

Analysis of Quench Generation in Fault Types According to Inductance Variation in Integrated Three-Phase Flux-Lock Type Superconducting Fault Current Limiting (삼상일체화된 자속구속형 고온초전도 전류제한기의 인덕턴스 변화에 따른 사고유형별 퀜치발생 분석)

  • Park, Chung-Ryul;Lim, Sung-Hun;Park, Hyoung-Min;Cho, Yong-Sun;Choi, Hyo-Sang;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.165-166
    • /
    • 2005
  • In this paper, we investigated the quench generation of HTSC elements in fault types according to inductance variation in the integrated three-phase flux-lock type SFCL. The integrated three-phase flux-lock type SFCL was the upgrade version of the single-phase flux-lock type SFCL. The structure of the integrated three-phase flux-lock type SFCL consisted of three-phase flux-lock reactor wound on an iron core with the ratio of the same turn between coil 1 and coil 2 in each phase. When the SFCL is operated under the normal condition, the flux generated in the iron core is zero because the flux generated between two coils of each single phase is canceled out. Therefore, the SFCL's impedance is zero, and the SFCL has negligible influence on the power system. However, if a fault occurs in any single-phase among three phases, the flux generated in the iron core is not zero any more. The flux makes HTSC elements of all phases quench irrespective of the fault type, which reduces the current of fault phase as well as the current of sound phase. It was observed that the fault current limiting characteristics of the suggested SFCL were dependent on the quench characteristics of HTSC elements in all three phases.

  • PDF

Analysis of Fault Current limiting Characteristics According to Fault Type in Integrated Three-Phase Flux-Lock Type Superconducting Fault Current limiting (사고종류에 따른 삼상 일체화된 자속구속형 SFCL의 사고전류제한특성 분석)

  • Park, Chung-Ryul;Lim, Sung-Hun;Park, Hyoung-Min;Cho, Yong-Sun;Choi, Hyo-Sang;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.54-56
    • /
    • 2005
  • In this paper, we investigated the quench characteristics of HTSC elements in the integrated three-phase flux-lock type SFCL according to fault types such as the single-line-to-ground fault, the double-line-to-ground fault, the line-to-line fault and the three-line-to-ground fault. The integrated three-phase flux-lock type SFCL was the upgrade version of the single-phase flux-lock type SFCL. The structure of the integrated three-phase flux-lock type SFCL consisted of three-phase flux-lock reactor wound on an iron core with the ratio of the same turn between coil 1 and coil 2 in each phase. When the SFCL is operated under the normal condition, the flux generated in the iron core is zero because the flux generated between two coils of each single phase is canceled out. Therefore, the SFCL's impedance is zero, and the SFCL has negligible influence on the power system. However, if a fault occurs in any single-phase among three phases, the flux generated in the iron core is not zero any more. The flux makes HTSC elements of all phases quench irrespective of the fault type, which reduces the current of fault phase as well as the current of sound phase. It was observed that the fault current limiting characteristics of the suggested SFCL were dependent on the quench characteristics of HTSC elements in all three phases.

  • PDF