• Title/Summary/Keyword: LNG storage tank

Search Result 211, Processing Time 0.028 seconds

A Study on Integrated Control and Safety Management Systems for LNG Membrane Storage Tank (멤브레인식 LNG 저장탱크용 통합제어안전관리시스템에 대한 연구)

  • Kim, Chung-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.2
    • /
    • pp.40-46
    • /
    • 2010
  • In this study, the integrated control and safety management system for a super-large LNG membrane storage tank has been presented based on the investigation and analysis of measuring equipments and safety analysis system for a conventional LNG membrane storage tank. The integrated control and safety management system, which may increase a safety and efficiency of a super-large LNG membrane storage tank, added additional pressure gauges and new displacement/force sensors at the steel anchor between an inner tank and a prestressed concrete structure. The displacement and force sensors may provide clues of a membrane panel failure and a LNG leakage from the inner tank. The conventional leak sensor may not provide proper information on the membrane panel fracture even though LNG is leaked until the leak detector, which is placed at the insulation area behind an inner tank, send a warning signal. Thus, the new integrated control and safety management system is to collect and analyze the temperature, pressure, displacement, force and LNG density, which are related to the tank system safety and leakage control from the inner tank. The digital data are also measured from measurement systems such as displacement and force of a membrane panel safety, LNG level and density, cool-down process, leakage, and pressure controls.

The Evaluation of Mechanical Properties and Fatigue Life for Domestic 304 Stainless Steel Used as Membrane Material in LNG Storage Tank (LNG저장탱크의 멤브레인용 국산 304 스테인리스강의 기계적성질 및 피로수명 평가)

  • Kim, Hyeong-Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.10
    • /
    • pp.1644-1650
    • /
    • 2001
  • Mechanical properties of domestic 374 stainless steel have been evaluated fur membrane material used in LNG storage tank. LNG tank is operated around -162$^{\circ}C$. The temperature of membrane depends on LNG level. Accordingly, the membrane material is deteriorated by variation of liquid pressure and temperature. Tensile test and fatigue life test were performed at room temperature and -l62$^{\circ}C$ per code requirements. Especially the biaxial fatigue life test was conducted with shaped membrane sheet at a thermal strain of $\Delta$T=190$^{\circ}C$ The test results obtained with the domestic 304 stainless steel showed better properties compared to the values required by code.

The Study of Kogas Membrane Performance Test for LNG Storage Tank (Kogas 멤브레인 성능평가에 관한 연구)

  • Kim Y.K.;Hong S.H.;Yoon I.S.;Oh B.T.;Seo H.S.
    • Journal of the Korean Institute of Gas
    • /
    • v.6 no.4 s.18
    • /
    • pp.17-22
    • /
    • 2002
  • LNG demand has been rapidly increasing in Korea for a variety of reasons including stable supply, non-polluting, and high combustion efficiency characteristics. One of the most important structural core element of the LNG storage tank is the membrane, consisting of stainless steel. The membrane to be applied inside of LNG storage tank is provided with corrugations to absorb thermal contraction and expansion caused by LNG temperature. Experimental studies are presented to investigate the deformation and strength of the membrane which is designed by Kogas. All experiments are conducted on the basis of RPIS, and we found the results is fully satisfied with the RPIS.

  • PDF

Review about Thermal Stability Reinforcing Method of the Concrete Sidewall of the LNG Storage Tank Using Sprayed PUF (스프레이 PUF를 이용한 LNG 저장탱크 외조 벽체의 열적 안정성 강화 방법에 대한 고찰)

  • Lee, Yeongbeom;Choe, Keonhyeong;Yoon, Ihnsoo;Han, Chonghun
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.1
    • /
    • pp.17-24
    • /
    • 2014
  • LNG storage tank is a facility to store liquefied natural gas (LNG) and its safety and stability to be greatly needed. When there is a LNG leakage in case of primary container problem, a special facility such as a bund wall should be constructed to store the leaked LNG. But this method makes the land usage inefficient and construction price high. So nowadays the full containment type LNG storage tank is selected instead of constructing a bund wall. In the full containment type tank, the concrete sidewall has the ability to store LNG temporarily. There are largely two methods to give the concrete sidewall the ability. In a method, rebar should be used when constructing the side wall of the LNG storage tank. In the other method, the protecting material such as sprayed polyurethane foam should be applied on the inner surface of the concrete sidewall. Sprayed PUF keeps the temperature of the sidewall above the specified temperature during the specified periods. Recently the thermal stability reinforcing method using sprayed polyurethane foam has been applied to all LNG storage tank built in Korea.

A Study on the Strength Safety Analysis of a Full Containment LNG Storage Tank Due to a Wind Pressure (완전밀폐식 LNG 저장탱크에 작용하는 풍압에 의한 강도안전 해석에 관한 연구)

  • Kim, Chung-Kyun;Jeong, Nam-In
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.1
    • /
    • pp.36-41
    • /
    • 2008
  • Using the finite element analysis, this paper presents the strength safety of a side wall of an outer tank and a roof structures in a full containment LNG storage tank system. The outer tank structure in which is constructed with a prestressed concrete is forced by internal hydrostatic and hydrodynamic pressures of a leaked LNG and an external wind pressure including a typhoon one. The FEM computed results show that the ring beam between a side wall of an outer tank and a roof structure supports most of the internal and the external loads. This means that the design point of the outer tank system is a ring beam structure and the other one is a center part of the roof structure. In this FE analysis model of a full containment LNG tank system, the outer tank and the roof structures are safe for the given combined loads such as an internal leaked LNG pressure and an external typhoon pressure.

  • PDF

A Study on the Integrated Control and Safety Management System for 9% Ni Steel LNG Storage Tank (9% 니켈강재식 LNG 저장탱크용 통합제어안전관리시스템에 관한 연구)

  • Kim, Chung-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.5
    • /
    • pp.13-18
    • /
    • 2010
  • This paper presents the development of an integrated control and safety management system for 9% nickel steel LNG storage tank. The new system added the measuring equipment of pressure, displacement and force compared to the conventional measurement and control system. The measured data has simultaneously been processed by integrating and analyzing with new control equipments and safety management systems. The integrated control and safety management system, which may increase a safety and efficiency of a super-large full containment LNG storage tank, added additional pressure gauges and new displacement/force sensors at the outer side wall and a welding zone of a stiffener and top girder of an inner tank, and the inner side wall of a corner protection tank. The displacement and force sensors may provide failure clues of 9% nickel steel structures such as an inner tank and a corner protection, and a LNG leakage from the inner tank. The conventional leak sensor may not provide proper information on 9% nickel steel tank fracture even though LNG is leaked until the leak detector, which is placed at the insulation area between an inner tank and a corner protection tank, sends a warning signal. Thus, the new integrated control and safety management system is to collect and analyze the temperature, pressure, displacement, force, and LNG density, which are related to the tank system safety and leakage control from the inner tank. The digital data are also measured from control systems such as displacement and force of 9% nickel steel tank safety, LNG level and density, cool-down process, leakage, and pressure controls.

Integrity comparison for various design specifications of corner protections in LNG storage tank (LNG저장탱크 코너프로텍션의 설계사양에 따른 건전성 비교)

  • Kim Hyoungsik;Hong Seongho;Seo Heungseok
    • Journal of the Korean Institute of Gas
    • /
    • v.6 no.4 s.18
    • /
    • pp.33-39
    • /
    • 2002
  • [ $9\%$ ] nickel steel LNG storage tank have double containments that can store cryogenic LNG independently. Inner tank material is used as $9\%$ nickel steel and outer tank is constructed by concrete. Comer protection which is installed on inner surface of concrete corner is consist of $9\%$ nickel steel liner and form glass insulator that make reduce tension at corner when LNG is leaked from inner tank. It is very difficult to design corner protection because expansion and contraction of liner make stress state complex. Corner protections of operating tank in KOGAS are designed by Japanese engineering company such as TKK, KHI and England company of WHESSOE. This paper is mainly focused on the integrity comparison of them according to requirements of Appendix 4 in ASME Section VIII Div. 2 by using FEM.

  • PDF

Advanced Heat Transfer Analysis Model of LNG Storage Tank (LNG 저장탱크의 개선된 온도해석 모델)

  • 전세진;정철헌;진병무;김성운
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.115-120
    • /
    • 2003
  • Several methodologies were devised to reasonably predict the temperature boundary conditions of inner face of the concrete outer tank so as to set up heat transfer analysis model of the full containment above-ground LNG storage tank. In this model, outer tank is solely taken into account and the beneficial effect of suspended deck and insulation layers on the temperature distribution of outer tank is separately formulated according to the proposed procedures. More effective design of the insulations can be achieved when the proposed simple schemes are used in the preliminary stage.

  • PDF

The Analysis of LNG Storage Tank Steel Roof Behavior by the Change of Design Variables (설계 변수 변화에 따른 LNG 저장탱크 Steel Roof 거동 분석)

  • Kim Y,K.;Kim J.H.;Oh B.T,;Yoon I.S.;Yang Y,M.
    • Journal of the Korean Institute of Gas
    • /
    • v.9 no.1 s.26
    • /
    • pp.33-37
    • /
    • 2005
  • This paper deals with parametric studies for the structural response of LNG Storage Tank steel roof behavior acoording to change in design condition. In the design of steel roof, it may be required to represent a stable behavior under many loading conditions and those of combinations. We fulfill the analysis the steel roof behavior during concret placing and additionally change the design variabls like H beam, pressure and steel roof plate thickness. On the basis of the obtained results from this studies a guideline for a more reasonable design of LNG storage tank steel roof is introduced.

  • PDF

The Development of Wall Membrane for LNG Storage Tank (LNG 저장탱크용 벽체 멤브레인 개발)

  • Oh, B.T.;Hong, S.H.;Yoon, I.S.;Kim, Y.K.;Seo, H.S.
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.907-912
    • /
    • 2001
  • KOGAS had developed the Ring-knot membrane for LNG storage tank. But we found that some modifications were needed in using the Ring-knot membrane for the commercial LNG storage tanks. So, both analytical and experimental studies have been performed to investigate the strength of the new membrane and the reaction force at the anchor point. Using nonlinear FEM code and experiments, the stress analysis of the new corrugated membrane shapes subject to the cryogenic liquid pressure and thermal loading are performed to ensure the stability and fatigue strength of the new membrane. This paper reports on the results of investigations into this new type of membrane.

  • PDF