• Title/Summary/Keyword: LNG membrane

Search Result 148, Processing Time 0.026 seconds

Experimental Study of Impact Behaviors of the Membrane for LNG Storage Tank (LNG 저장탱크용 멤브레인의 충격거동에 관한 실험적 연구)

  • Kim, Young-Gyu;Kim, Chung-Kyun
    • Journal of the Korean Society of Safety
    • /
    • v.10 no.4
    • /
    • pp.68-74
    • /
    • 1995
  • This paper analyzes the behaviors of the membrane under drop impact loadings using the acoustic emission technique. The analysis is useful for evaluating the strength of the membrane as well as for studying its damping characterisics due to the corrugation and the ring knot. The membrane for LNG storage tank is basically composed linear and circular elements. Two membrane specimens have approximately same drop impact mass and same drop speed. Locan 320 system with piezoelectric sensor is used in the experimental measurement. Experimental results for the membranes indicated that AE siganls having higher energies were generated with increasing drop impact loadings. It was confirmed that the ring knot. membrane has high absorption of drop impact loadings in comparison with the flat membrane. These results are very important to reliable design and to improve the safey of the membrane components.

  • PDF

Numerical Model of Heat Diffusion and Evaporation by LNG Leakage at Membrane Insulation (LNG 화물창 방열재 균열에 따른 액화천연가스의 확산 및 온도 예측을 위한 수치 모델)

  • Lee, Jang Hyun;Kim, YoonJo;Hwang, Se Yun
    • Journal of Ocean Engineering and Technology
    • /
    • v.28 no.6
    • /
    • pp.517-526
    • /
    • 2014
  • The leakage of cryogenic LNG through cracks in the insulation membrane of an LNG carrier causes the hull structure to experience a cold spot as a result of the heat transfer from the LNG. The hull structure will become brittle at this cold spot and the evaporated natural gas may potentially lead to a hazard because of its flammability. This paper presents a computational model for the LNG flow and heat diffusion in an LNG insulation panel subject to leakage. The temperature distribution in the insulation panel and the speed of gas diffusion through it are simulated to assess the safety level of an LNG carrier subject that experiences a leak. The behavior of the leaked LNG is modeled using a multiphase flow that considers the mixture of liquid and gas. The simulation model considers the phase change of the LNG, gas-liquid multiphase interactions in the porous media, and accompanying rates of heat transfer. It is assumed that the NO96-GW membrane storage is composed of glass wool and plywood for the numerical simulation. In the numerical simulation, the seepage, heat diffusion, and evaporation of the LNG are investigated. It is found that the diffusion speed of the leakage is very high to accelerate the evaporation of the LNG.

On the Leakage Safety Analysis of Membrane LNG Storage Tank With Thermal Resistance Effects (열저항 효과를 고려한 멤브레인식 LNG 저장탱크의 누설 안전성에 관한 연구)

  • Kim C.K.;Cho S.H.;Suh H.S.;Hong S.H.;Lee S.R.;Kim Y.G.;Kwon B.K.
    • Journal of the Korean Institute of Gas
    • /
    • v.8 no.4 s.25
    • /
    • pp.1-7
    • /
    • 2004
  • In this paper, the FE analysis has been presented for the leakage safety of the membrane LNG storage tank based on the thermal resistance effects between the insulation panel and prestressed concrete structure. The FEM calculated results show that the leakage safety of plywood and polyurethane materials does not guarantee any more due to a strength failure of the insulation structure. But the PC structure of outer tank may delay leaked LNG of 10 days even though the inner tank and insulation structure are simultaneously failed. This means that the membrane LNG storage tank may be safe because of the stiffness of the outer tank.

  • PDF

Development of the Automatic Design Program for Scaffolding System of the Membrane LNG Carrier (멤브레인 LNG 운반선용 스카폴딩 시스템의 자동 설계 프로그램 개발)

  • Lee, Hee-Tae;Shin, Sang-Beom;Park, Yun-Ki
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.47 no.2
    • /
    • pp.233-241
    • /
    • 2010
  • Scaffolding system in the membrane LNG carrier is a steel structure composed of various pipe-shaped members connected by specific coupling devices. In this study, the automatic design program for scaffolding system in membrane LNG carrier has been developed. It enables user to arrange members easily considering design constraints and input variables such as size of tank, position of legs, level height and so on. In addition to that, it creates finite element analysis model with loading and boundary conditions automatically and carries out structural analysis. With post processor based a state-of-the-art computer graphics, users can easily check the results of structural analysis and make a report for structural safety of scaffolding system.

The Stress Measurement of Membrane Type LNG Storage Tank (멤브레인식 LNG저장탱크 응력측정법)

  • Kim, Y.K.;Hong, S.H.;Yoon, I.S.;Oh, B.T.;Seo, H.S.
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.138-142
    • /
    • 2000
  • In LNG Tank, it is very important to measure the strain in Membrane by theoretical and experimental stress analysis. In this paper, perform the test about strain gage, thermal sensor and lead wire to make clear the properies. The test results conclude that stress measurement by strain gage must consider the effect of many factors to measure strain acculately. The corrections should be made on apparent strain, lead wire length and Membrane shape. It is also important to measure the temperatures accurately at the strain gage location

  • PDF

Evaluation on the Formability of Corrugated Membrane panels of a LNG Storage Tank (LNG 저장탱크용 멤브레인의 성형성 평가)

  • 박구환;변상규;김성원;강범수
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1997.10a
    • /
    • pp.98-101
    • /
    • 1997
  • Membrane panels for LNG(Liquid Natural Gas) tank are formed to corrugared ones by press forming. The environment of LNG tank is so severe that the service temperature is -162$^{\circ}C$ and the room temperature is 20$^{\circ}C$. The thermal deformation derived by the severe temperature change is absorbed by the corrugations of the membrane panels. In this paper the formability of stainless steel membrane panel is examined by the finite element analysis. Two corrugated shapes are suggested, and analyzed to obtain a sound absorption performance of the thermal distortion. Also the design considers forming characteristics and economy of production.

  • PDF

Status and Prospect of Site Welding Technology for LNG Strorage Tank (LNG 저장탱크의 현장용접 시공기술의 현상 및 전망)

  • 이광희;전혁성
    • Journal of Welding and Joining
    • /
    • v.13 no.3
    • /
    • pp.8-17
    • /
    • 1995
  • LNG를 저장할 수 있는 탱크는 주로 지상식이거나 반지하식이며 그 용량은 매우 다양하다. 우리나라에서는 지상식 탱크가 평택 인수기지에 10만m$^{3}$급 Membrane Type 6기가 건설되었고 1기는 거의 완성단계이며, 현재 추가로 건설 중인 3기를 포함하면 총 10기의 탱크를 확보하게 된다. 또한 제2인수기지인 인천에도 동급 으로서 9%Ni강을 사용하는 Double Wall Type LNG 탱크 3기를 건설 중이다. 전세계적 으로 볼 때 LNG 저장 탱크의 78%는 지상식으로 Double Wall Type 또는 Membrane 저장 탱크 형식을 취하고 있으나, 최근에는 안전성 측면, 토지 가격의 상승, 토지의 합리적 이용 측면 등을 감안하여 LNG 탱크를 지하화, 대형화하는 추세이다. 본고에서는 Fig. 1과 같은 구조의 Double Wall Type LNG 저장탱크 중 초저온의 LNG에 직접 접하는 저 온용 재료(9%니켈강)로 만들어지는 내조 용접에 대해서 중점적으로 논하기로 하며, 특히 9% 니켈강 Shell Plate Horizontal Joint에 채용되는 Automatic Submerged ARC 용접에 대해 실제 현장 용접 시공상태를 나타내고자 한다.

  • PDF

A Study on Low Temperature Strength and Fatigue Strength of Austenitic Stainless Steel for Membrane Type LNG Tank (멤브레인형 LNG 탱크용 오스테나이트계 스테인리스강의 저온강도 및 피로강도에 관한 연구)

  • 이해우;신용택;박정웅;이재원;강창룡
    • Journal of Welding and Joining
    • /
    • v.17 no.3
    • /
    • pp.50-54
    • /
    • 1999
  • Feasibility study of the application of a developed annealed austenitic stainless steel at cryogenic temperature has been performed for membrane tank of LNG ship. Chemical properties of developed stainless steel are compared with a domestic commercial stainless steel and a foreign stainless steel which are used for LNG ships. Tensile properties at cryogenic temperature and fatigue strength at room temperature are measured for but and lap joints which are TIG welded specimens. Developed stainless steel having a small amount of titanium component shows the finest grain size in the HAZ, compared with the other stainless steel studied. Tensile strength, elongation and fatigue strength of the developed stainless steel are equal to those of the foreign stainless steel studied and are higher than the domestic commercial stainless steel studied.

  • PDF

Numerical Simulation of Membrane of LNG Insulation System using User Defined Material Subroutine (사용자지정 재료 서브루틴을 활용한 LNG선박 단열시스템 멤브레인의 수치해석)

  • Kim, Jeong-Hyeon;Kim, Seul-Kee;Kim, Myung-Soo;Lee, Jae-Myung
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.27 no.4
    • /
    • pp.265-271
    • /
    • 2014
  • 304L stainless steel sheets are used as a primary barrier for the insulation of membrane-type liquefied natural gas(LNG) carrier cargo containment system. 304L stainless steel is a transformation-induced-plasticity(TRIP) steel that exhibits complex material behavior, because it undergoes phase transformation during plastic deformation. Since the TRIP behavior is very important mechanical characteristics in a low-temperature environment, significant amounts of data are available in the literature. In the present study, a uniaxial tensile test for 304L stainless steel was performed to investigate nonlinear mechanical characteristics. In addition, a viscoplastic model and damage model is proposed to predict material fractures under arbitrary loads. The verification was conducted not only by a material-based comparative study involving experimental investigations, but also by a structural application to the LNG membrane of a Mark-III-type cargo containment system.

A Study on Simplified Sloshing Impact Response Analysis for Membrane-Type LNG Cargo Containment System (LNG 화물창 단열구조의 슬로싱 충격응답 간이해석법에 관한 연구)

  • Nho, In-Sik;Ki, Min-Seok;Kim, Sung-Chan
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.48 no.5
    • /
    • pp.451-456
    • /
    • 2011
  • To ensure structural integrity of membrane type LNG tank, the rational assessment of the sloshing impact responses of tank structures should be preceded. The sloshing impact pressures acting on the insulation system of LNG tank are typical irregular loads and the resulting structural responses show very complex behaviors accompanied with fluid structure interaction. So it is not easy to estimate them accurately and immense time consuming calculation process would be necessary. In this research, a simplified method to analyse the dynamic structural responses of LNG tank insulation system under pressure time histories obtained by sloshing model test or numerical analysis was studied. The proposed technique based on the concept of linear combination of the triangular response functions which are the transient responses of structures under the unit triangular impact pressure acting on structures. The validity of suggested method was verified through the example calculations and applied to the dynamic structural response analysis of a real Mark III membrane type insulation system using the sloshing impact pressure time histories obtained by model test.