• Title/Summary/Keyword: LMU

Search Result 12, Processing Time 0.021 seconds

LMU Design Optimization for the Float-Over Installation of Floating Offshore Platforms (부유식 해양구조물의 플로트오버 설치용 LMU 최적설계)

  • Kim, Hyun-Seok;Park, Byoungjae;Sung, Hong Gun;Lee, Kangsu
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.34 no.1
    • /
    • pp.43-50
    • /
    • 2021
  • A Leg Mating Unit (LMU) is a device utilized during the float-over installation of offshore structures that include hyperelastic pads and mating part. The hyperelastic pads absorb the loads, whereas the mating part works as guidance between topside and supporting structures during the mating sequence of float-over installation. In this study, the design optimization of an LMU for the float-over installation of floating-type offshore structures is conducted to enhance the performance and to satisfy the requirements defined by classification society regulations. The initial dimensions of the LMU are referred to the dimensions of those used in fixed-type float-over installation because only the location and the number of LMUs are known. The two-parameter Mooney-Rivlin model is adopted to describe the hyperelastic pads under given material parameters. Geometric variables, such as the thickness, height, and width of members, as well as configuration variables, such as the angle and number of members, are defined as design variables and are parameterized. A sampling-based design sensitivity analysis based on latin hypercube sampling method is performed to filter the important design variables. The design optimization problem is formulated to minimize the total mass of the LMU under maximum von Mises stress and reaction force constraints.

Structural Optimization of an LMU Using Approximate Model (근사모델을 이용한 의 구조최적설계)

  • Han, Dong-Seop;Jang, Si-Hwan;Park, Soon-Hyeong;Lee, Kwon-Hee
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.6
    • /
    • pp.75-82
    • /
    • 2018
  • This study suggests an optimal design process of an LMU, which is installed on the top side of offshore structures. The LMU is consist of EB(elastomeric bearing) and steel plate, and supports the vertical loads of offshore structures and assists its stable installation. The structural design requirement of the LMU is related to its stiffness. This study utilizes the finite element analysis to predict the stiffness. The stiffness of the EB depends on the size of the bearing. Thus, the design variables in this study are defined as the thickness, the width and the number of plates. Since the LMU has different loads for different locations, its stiffness should be designed differently. The multiobjective function is introduced to attain the target stiffness. In this process, the metamodel using the kriging interpolation method is adopted to replace the true stiffness.

A Study on the Development of an Engine Monitoring System for Small Vessel Using CSMA/CD (CSMA/CD 프로토콜을 이용한 중.소형 선박용 기관 모니터링 시스템 구성에 관한 연구)

  • 신명철;고두석;윤경국;안병원;김윤식
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.3 no.2
    • /
    • pp.455-463
    • /
    • 1999
  • This study is on the development of an engine monitoring system which can be applied not only for mid-size vessels but also small vessels less than 20 gross tonnage. Monitoring system consists of a set LMU(Local Monitoring Unit) that collect data from local machinery, a host computer that controls LMU and a stable communication system which adopts CSMA/CD protocol. The LMU is composed of 80C196KC microprocessor, which consists of CPU, digital input/output, analog input/output and communication module. Communication system between the host computer(compatible IBM PC) and LMUs is the multidrop configuration using RS-485 method and confirmed high performance communication by the aid of polling method as well as carrier sense multiple access with collision detection(CSMA/CD) protocol.

  • PDF

The study on the LBS for WiBro repeater (휴대인터넷 중계기를 위한 LBS 적용 방안에 관한 연구)

  • Ahn Jun-Bae;Ryoo Kyoo-Tae
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.53-56
    • /
    • 2006
  • WiBro service provider have made an effort to provide the subscriber's location and have deployed LBS system using cell-ID method. Cell-ID method has a location error problem if repeater is used on the other cell places at the same time. We introduce and analysis LMU(Location Measurement Unit) on the repeater fer location detection of subscriber which is serviced via the repeater. In this paper we propose the method using LMU on the repeater to avoid these location errors and to provide more exact location to the subscriber. we can conclude that the location error can be more exact at the building which uses repeater. It represents in which level the subscriber is serviced at the building.

  • PDF

Speciation Mode Reconstruction for Lepilemur six species (L. mustelinus, L. edwardsi, L. dorsalis, L. leucopus, L. ruficaudatus, L. septentrionalis) Based on the Lepilemur Karyotype Analysis (여우원숭이속(Lepilemuridae)의 핵형 분석을 통해 나타난 Lepilemur 6종(L. mustelinus, L. edwardsi, L. dorsalis, L. leucopus, L. ruficaudatus, L. septentrionalis)의 종 분화 양상)

  • 정기윤
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.5 no.2
    • /
    • pp.141-149
    • /
    • 2004
  • The aim of this study was to test the validity of the hypothesis that the karyotypes of four species of Lepilemuridae were formed spontaneously from their ancestral hybrid karyotype. Hypothetical ancestral haploid Karyotype of Lepilemuridae is composed of 18 autosomes and X chromosomes. Lepilemur mustelinus karyotype has four tandem fused chromosomes and one Robertsonian translocated chromosome pairs. Lepilemur septentrionalis septentrionalis karyotype has only two pairs of translocated chromosomes. We reconstruct and suggest ancestral karyotype of LMU(ancLMU) and LSS(ancLSS), from which all four studied species were derived. Hybrids of ancLMU and ancLSS were formed and produce differently fused equilibrated gametes via circular form arrangement during gametogenesis. Five unit of trivalent homologous chromosome pairs were engaged in a circular form to give new gamete corresponding to the karyotype of L. dorsalis, orientation of one unit of trivalent was inversed in the circle to gave new gamete corresponding to the karyotype of L. leucopus. Seven homologous chromosome pairs were engaged in circular form to give haploid karyotype of Lepilemur ruficaudatus. Only one homologous chromosome pair is dissociated and the other chromosome pairs rearranged in the circle to form haploid karyotype of Lepilemur edwardsi. The new gametes could be produced from these circular forms. When the new gamete fertilized with the same type of gamete, The new homozygote is produced as existing L. dorsalis, L. leucopus, L. edwardsi and L. ruficaudatus. These results support the theory that new species could be formed in hybrid population through activated chromosome fusion, chromosome rearrangement in circular from at zygotene stage and production of equilibrated gametes to form homozygote new species.

  • PDF

Assessment of N-Loading and Manure Units for Regional Recycling Farming -Case Study in Yeoju-Gun Region- (지역순환농업을 위한 분뇨단위 설정과 질소부하 평가 -여주지역 사례-)

  • Ryoo, Jong-Won;Choi, Deog-Cheon
    • Korean Journal of Organic Agriculture
    • /
    • v.20 no.1
    • /
    • pp.21-36
    • /
    • 2012
  • In this study, the assessment of livestock manure nitrogen loading for recycling farming in Yeoju-Gun carried out comparing manure units based on the cultivation areas and the N-amount of manure that are generated from livestock manure. Manure units (MU) are used in the permitting, registration, because they allow equal standards for all animals based on manure nutrient production. An MU is calculated by multiplying the number of animals by manure unit factor for the specific type of animal. The manure unit factor for MU determination was determined by dividing amounts of manure N produced 80kg N/year. In this study, manure unit by nitrogen concentration and amount of animal manure was calculated as follows: Hanwoo multiplied by 0.36, dairy cows multiplied by 0.8. swine multiplied by 0.105. The laying hens and broilers multiplied by 0.0079, 0.0049, respectively. The analysis of liquid manure unit per ha shows that the N loading by LMU is quite different by region. When it comes to nitrogen loading, the LMU per ha of cultivated land in excess of the N-amount was the highest in the Bukne-myeon province with 2.76 MU/ha, which is higher than the appropriate level. The Ganam-myeon province came next with 2.53 LMU. To be utilized as a valid program to build the environmentally friendly agricultural system, diverse measures shall be mapped out to properly determine manure units, evaluate N-loading and to properly manage their nutrient balance of each region.

Accuracy of intraoral scans of edentulous jaws with different generations of intraoral scanners compared to laboratory scans

  • Kontis, Panagiotis;Guth, Jan-Frederik;Schubert, Oliver;Keul, Christine
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.5
    • /
    • pp.316-326
    • /
    • 2021
  • PURPOSE. Purpose of this in vitro study was to determine the accuracy of different intraoral scans versus laboratory scans of impressions and casts for the digitization of an edentulous maxilla. MATERIALS AND METHODS. A PEEK model of an edentulous maxilla, featuring four hemispheres on the alveolar ridges in region 13, 17, 23 and 27, was industrially digitized to obtain a reference dataset (REF). Intraoral scans using Cerec Primescan AC (PRI) and Cerec AC Omnicam (OMN), as well as conventional impressions (scannable polyvinyl siloxane) were carried out (n = 25). Conventional impressions (E5I) and referring plaster casts were scanned with the inEOS X5 (E5M). All datasets were exported in STL and analyzed (Geomagic Qualify). Linear and angular differences were evaluated by virtually constructed measurement points in the centers of the hemispheres (P13, P17, P23, P27) and lines between the points (P17-P13, P17-P23, P17-P27). Kolmogorov-Smirnov test and Shapiro-Wilk test were performed to test for normal distribution, Kruskal-Wallis-H test, and Mann-Whitney-U test to detect significant differences in trueness, followed by 2-sample Kolmogorov-Smirnov test to detect significant differences in precision (P < .008). RESULTS. Group PRI showed the highest trueness in linear and angular parameters (P < .001), while group E5I showed the highest precision (P < .001). CONCLUSION. Intraoral scan data obtained using Primescan showed the highest trueness while the indirect digitization of impressions showed the highest precision. To enhance the workflow, indirect digitization of the impression itself appears to be a reasonable technique, as it combines fast access to the digital workflow with the possibility of functional impression of mucosal areas.

Stiffness evaluation of elastomeric bearings for leg mating unit (LMU용 일래스토머릭 베어링의 강성평가)

  • Han, Dong-Seop;Jang, Si-Hwan;Lee, Kwon-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.106-111
    • /
    • 2017
  • In this study, the stiffness of an LMU (Leg Mating Unit), which is a device required for installing the top side part of an offshore structure, was examined through structural analysis. This unit is mounted on the supporting point of the structure and is used to absorb the shock at installation. It is a cylindrical structure with an empty center. To support the vertical load, elastomeric bearings (EBs) and iron plates are laminated in layers. The stiffness of the EBs is basically influenced by the size of the bearings, but it varies with the number of laminated sheets inside the same sized structure. The relationship between the stiffener and the compressive stiffness is investigated, and its design is suggested. The stiffness of the EBs is analyzed by calculating the reaction force, while controlling the displacement. First, the relationship between the size of the reinforcing plate and the compressive stiffness is considered. Next, the relationship between the number of stacked reinforcing plates and the compression stiffness is considered. Different loads are required for each installed point. The goal is to design the compression stiffness in such a way that the same deformation occurs at each point in the analysis. In this study, ANSYS is used to perform the FE analysis.

Design of a Paging Scheme based on user Mobility Classes for Advanced Cellular Mobile Networks (차세대 이동통신망을 위한 사용자 이동패턴에 근거한 페이징 기법의 설계)

  • Jeon, Wha-Sook;Jeong, Dong-Geun
    • Journal of KIISE:Information Networking
    • /
    • v.29 no.3
    • /
    • pp.216-223
    • /
    • 2002
  • This paper proposes an efficient location management scheme for next-generation cellular mobile networks. In the proposed scheme, the users are classified into two classes according to their mobility patterns; high mobility users (HMU) and low mobility users (LMU). We design the intelligent location management strategy based on theme user mobility classes. The performance of the proposed scheme is compared with that of pure intelligent paging scheme by computer simulation. As a result, it is shown that the proposed scheme provides the better performance than the pure intelligent paging scheme.

Inorganic and Transition Metal Azides

  • Seok, Won-K.;Klapotke, Thomas M.
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.4
    • /
    • pp.781-788
    • /
    • 2010
  • Experimental and theoretical studies show that all covalent azides possess a nonlinear azide group. They also rationalize this remarkable structural feature. We have seen that the most important non-covalent contributions in the covalently bound azides system (X-N1-N2-N3) are the $\pi$-delocalization over the entire molecule and a strong negative hyperconjugation which donates electron density from the filled $\sigma$ (X-N1) orbital into the unfilled, antibonding $\pi^*$ (N2-N3) orbital. For transition metal azide complexes, a bent configuration and a small difference between the N-N bond lengths, generally the longer one being adjacent to the transition metal, were observed.