• Title/Summary/Keyword: LMF

Search Result 41, Processing Time 0.202 seconds

Interference Cancellation System in Repeater Using Signed-Signed LMF Algorithm (Signed-Signed LMF 알고리즘을 이용한 간섭제거 중계기)

  • Han, Yong-Sik
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.5
    • /
    • pp.805-810
    • /
    • 2019
  • Recently, a majority of 4G mobile telecommunication manufacturers prefer repeaters with good adaptability. In this paper, we propose a new LMF(: Least Means Fourth) algorithm for LTE(: Long Term Evolution) RF(: Radio Frequency) Repeater. The proposed algorithm is a modification of the LMF, which appropriately adjusts the step size and improves performance according to the Sign function. The steady state MSE(: Mean Square Error) performance of the proposed LMF algorithm with step size of 0.009 is low level at about -25dB, and the proposed LMF algorithm requires 500 less iterations than the conventional algorithms at MSE of -25dB.

A Study on Least Mean Fourth (LMF) and Least Mean Squares-Fourth (LMSF) Blind Equalization Algorithm (최소평균 사제곱 (LMF) 및 최소평균 제곱과 사제곱을 혼합한 형태 (LMSF)의 블라인드 등화 알고리즘에 관한 연구)

  • Yoon, Tae-Sung;Byun, Youn-Shik
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.38-44
    • /
    • 1997
  • In this study, wer derived LMF-Sato, LMSF-Sato complex blind equalization algorithms for complex data. And then, the convergence rates, the convergence characteristics at the steady state and the stability of the proposed LMF and LMSF blind equalization algorithms are compared with those of LMS-Sato blind equalization algorithm. In simulations with 16-QAM data, LMF-Sato and LMSF-Sato algorithms showed better performance comparing with LMS-Sato algorithm generally. When the initial estimation errors of the weights of the equalizer are large, LMF-Sato algorithm showed ill characteristic in stability. However, LMSF-Sato algorithm has good covergence characteristics and preserves robustness.

  • PDF

An algebraic step size least mean fourth algorithm for acoustic communication channel estimation (음향 통신 채널 추정기를 이용한 대수학적 스텝크기 least mean fourth 알고리즘)

  • Lim, Jun-Seok
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.1
    • /
    • pp.55-62
    • /
    • 2016
  • The least-mean fourth (LMF) algorithm is well known for its fast convergence and low steady-state error especially in non-Gaussian noise environments. Recently, there has been increasing interest in the least mean square (LMS) algorithms with variable step size. It is because the variable step-size LMS algorithms have shown to outperform the conventional fixed step-size LMS in the various situations. In this paper, a variable step-size LMF algorithm is proposed, which adopts an algebraic optimal step size as a variable step size. It is expected that the proposed algorithm also outperforms the conventional fixed step-size LMF. The superiority of the proposed algorithm is confirmed by the simulations in the time invariant and time variant channels.

An acoustic channel estimation using least mean fourth with an average gradient vector and a self-adjusted step size (기울기 평균 벡터를 사용한 가변 스텝 최소 평균 사승을 사용한 음향 채널 추정기)

  • Lim, Jun-Seok
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.3
    • /
    • pp.156-162
    • /
    • 2018
  • The LMF (Least Mean Fourth) algorithm is well known for its fast convergence and low steady-state error especially in non-Gaussian noise environments. Recently, there has been increasing interest in the LMS (Least Mean Square) algorithms with self-adjusted step size. It is because the self-adjusted step-size LMS algorithms have shown to outperform the conventional fixed step-size LMS in the various situations. In this paper, a self-adjusted step-size LMF algorithm is proposed, which adopts an averaged gradient based step size as a self-adjusted step size. It is expected that the proposed algorithm also outperforms the conventional fixed step-size LMF. The superiority of the proposed algorithm is confirmed by the simulations in the time invariant and time variant channels.

Leakage Magnetic Field Suppression Using Dual-Transmitter Topology in EV Wireless Charging

  • Zhu, Guodong;Gao, Dawei;Lin, Shulin
    • Journal of Power Electronics
    • /
    • v.19 no.3
    • /
    • pp.625-636
    • /
    • 2019
  • This paper proposes an active leakage magnetic field (LMF) suppression scheme, which uses the dual-transmitter (DT) topology, for EV wireless charging systems (EVWCS). The two transmitter coils are coplanar, concentric and driven by separate inverters. The LMF components generated by the three coils cancel each other out to reduce the total field strength. This paper gives a detailed theoretical analysis on the operating principles of the proposed scheme. Finite element analysis is used to simulate the LMF distribution patterns. Experimental results show that when there is no coil misalignment, 97% of the LMF strength can be suppressed in a 1kW prototype. These results also show that the impact on efficiency is small. The trade-off between LMF suppression and efficiency is revealed, and a control strategy to balance these two objectives is presented.

Single Oral Dose Toxicity Test of Low Molecular Weight Fucoidan in Rats

  • Yoon, Hyun-Soo;Shin, Yong-Kyu;Jung, Young-Mi;Lee, Hyeung-Sik;Ku, Sae-Kwang
    • Biomolecules & Therapeutics
    • /
    • v.17 no.3
    • /
    • pp.325-331
    • /
    • 2009
  • The object of this study was to evaluate the single oral dose toxicity of Low Molecular Weight Fucoidan (LMF) in male and female rats. LMF was administered to female and male SD rats as an oral dose of 2,000, 1,000 and 500 mg/kg (body wt.). Animals were monitored for the mortality and changes in body weight, clinical signs and gross observation organ weight and histopathology of 14 principle organs were examined upon necropsy. As the results, no LMF treatment related mortalities, clinical signs, changes on the body and organ weights, gross and histopathological observations against 14 principle organs were detected up to 2,000 mg/kg in both female and male rats except for some sporadic findings not LMF treatment related toxicological signs. Therefore, $LD_{50}$ (50% lethal dose) and approximate LD of LMF after single oral treatment in female and male rats were considered over 2,000 mg/kg - the limited dosages recommended by KFDA Guidelines [2005-60, 2005], respectively.

A Regularized Mixed Norm Multi-Channel Image Restoration Algorithm (정규화 혼합 Norm을 이용한 다중 채널 영상 복원 방식)

  • 홍민철;신요안;이원철
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.2C
    • /
    • pp.272-282
    • /
    • 2004
  • This paper introduces a regularized mixed norm multi-channel image restoration algorithm using both within-and between- channel deterministic information. For each channel a functional which combines the least mean squares (LMS), the least mean fourth (LMF), and a smoothing functional is proposed. We introduce a mixed norm parameter that controls the relative contribution between the LMS and the LMF, and a regularization parameter defining the degree of smoothness of the solution, where both parameters are updated at each iteration according to the noise characteristics of each channel. The novelty of the proposed algorithm is that no knowledge of the noise distribution for each channel is required and that the parameters mentioned above are adjusted based on the partially restored image.

An Algorithm for the Characterization of Surface Crack by Use of Dipole Model and Magneto-Optical Non-Destructive Inspection System

  • Lee, Jin-Yi;Lyu, Sung-Ki;Nam, Young-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.10
    • /
    • pp.1072-1080
    • /
    • 2000
  • Leakage magnetic flux (LMF) is widely used for non-contact detection of cracks. The combination of optics and LMF offers advantages such as real time inspection, elimination of electrical noise, high spatial resolution, etc. This paper describes a new nondestructive evaluation method based on an original magneto-optical inspection system, which uses a magneto-optical sensor, LMF, and an improved magnetization method. The improved magnetization method has the following characteristics: high observation sensitivity, independence of the crack orientation, and precise transcription of the geometry of a complex crack. The use of vertical magnetization enables the visualization of the length and width of a crack. The inspection system provides the images of the crack, and shows a possibility for the computation of its depth.

  • PDF

Inhibition of Cytopathic Effect of Human Immunodeficiency Virus-1 by Water-soluble Extract of Ganoderma lucidum

  • Kim, Ha-Won;Shim, Mi-Ja;Choi, Eung-Chil;Kim, Byoung-Kak
    • Archives of Pharmacal Research
    • /
    • v.20 no.5
    • /
    • pp.425-431
    • /
    • 1997
  • To examine components of Ganoderma lucidum for anti-human immunodeficiency virus (HIV) activity, the aqueous extracts of its basidiocarps were separated into high-molecular-weight (HMF) and low-molecular-weight (LMF) fractions. These fractions were used in XTT [2,3-bis (2-methoxy-4-nitro-5-sulfophenyl)-5-[(phenylamino) carbonyl]-2H-tetrazolium hydroxide] antiviral assay which can quantitatively measure cytopathic effects of HIV-1 on CEM, human T lymphoblastoid cell line. The CEM cell line added with serial diluted HMF or LMF was cultured in the absence or presence of HIV-1. The results showed that the LMF of the aqueous extract strongly inhibited cytopathic effect of the target cell induced by HIV-1. When two-fold serially diluted LMF ranging from $40.97{\mu}g/ml$4 to 125.00 .mu.g/ml was added to the virus-free culture system, no toxicity on the target cells was detected in all the concentrations tested. However, when it was added to the HIV-infected culture system, the viabilities of the target cell reached a plateau recovering its viabilities to 71.7% and 82.5% in experiment-1 and -2 at 15.60 .mu.g/ml, respectively. The cell viabilities were then gradually decreased but maintained at more than 50% above 31.20 .mu.g/ml concentration. On the contrary, HMF did not prevent any HIV-induced cytopathic effect at any concentrations tested on this cell line. From these results, negligible toxicities were observed by both HMF and LMF of G. luciolum, and recovery of cell viability in HIV infected target cell was induced only by LMF of the carpophores.

  • PDF

Development of High-strength Polyethylene Terephthalate (PET) Sheet Through Low Melting Point Binder Compounding and Compression Process (저 융점 바인더 복합화 및 압착공정을 통한 고강도 폴리에틸렌 테레프탈레이트(PET) 시트 개발)

  • Moon, Jai Joung;Park, Ok-Kyung;Kim, Nam Hoon
    • Composites Research
    • /
    • v.33 no.5
    • /
    • pp.282-287
    • /
    • 2020
  • In the present study, a high-strength polyethylene terephthalate (PET) sheet was fabricated through a densification process of low melting PET fiber (LMF) combined PET sheet. During the thermal heat treatment process of the combined LMF, individual PET fiber was connected, which in turn leads to the improvement of the interfacial bonding force between the fibers. Also, the densification of the PET sheet leads to reduce macrospore density and in return could enhance the binding force between the overlapped PET networks. Consequently, the asprepared LMF-PET sheet showed about 410% improved tensile strength and the same elongation compared to before compression. Besides, the enhanced bonding force can prevent the shrinkage of the PET fiber network and exhibited excellent dimensional stability.