• Title/Summary/Keyword: LINKED SYSTEM

Search Result 1,889, Processing Time 0.034 seconds

The Analysis of Relationship between Railway Signaling Standards and Other Safety Standards for Safety Meaning Establishment (열차제어시스템 안전성 개념 확립을 위한 국제 표준들의 관계분석)

  • Jo, Hyun-Jeong;Hwang, Jong-Gyu
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1145-1146
    • /
    • 2008
  • Failures of equipments are linked directly to extensive damages of human lives or financial losses from the increasing uses of railway signaling equipments utilizing computers. Then safety organizations have to establish for guaranteeing safety during the system life-cycle. In this paper, we examine the relationship between railway signaling standards and other safety standards for safety meaning establishment.

  • PDF

PLC Manager for Incompatible PLCs in a Cell Controller (비호환 기종 PLC들의 통합제어를 위한 PLC매니저 설계)

  • Park, Won-Yil
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.4
    • /
    • pp.658-665
    • /
    • 1994
  • CIM is generally considered as a solution for total automation of a manufacturing system. In a CIM system, Flexible Manufacturing System(FMS) is linked colsely to the actual manufacturing line. This study will examine the strategy of integrating incompatible FA equipments, expecially PLCs (Programable Logic Controllers). PLC Manager is proposed as a model for integrating PLC algorithms, whose primary tasks are to communicate line-field data with PLCs and cell controller. To operate it, a PLC script language is designed and implemented.

A Study on the Overseas Case Analysis of Evacuation Guidance System for High-rise and Underground Complexes (초고층 및 지하연계 복합건축물 피난유도 시스템의 국외 사례 분석 연구)

  • Choi, Byeong-Yun;Kim, Dong-Oh;Seo, Jeong-Wan;Kang, Boo-Seong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.117-118
    • /
    • 2023
  • This study is a basic research study to establish an effective evacuation guidance system in case of fire in high-rise and underground-linked complex buildings. As a result of the analysis of overseas cases, it is judged that it is necessary to develop an evacuation guidance system using artificial intelligence.

  • PDF

Analysis of Sugar Chain Structure of PAS-7 Glycoprotein from Bovine Milk Fat Globule Membrane by US RAAM 2000 (OGS RAAM2000을 이용한 유지방구막 PAS-7 당단백질의 당쇄구조 해석)

  • 석진석
    • Food Science of Animal Resources
    • /
    • v.21 no.4
    • /
    • pp.367-373
    • /
    • 2001
  • Glycoproteins PAS-6(50 kDa) and -7(47 kDa) from the bovine milk fat globule membrane share a common protein core but differ in their carbohydrate moiety. We have analyzed and proposed the structures of the N-linked sugar chains of PAS-7 by Oxford Glyco System(OGS) RAAM2000. The N-linked sugar chains were liberated from PAS-7 by hydrazinolysis and, after modifying the reducing ends with 2-aminobenzamide(2-AB), were separated into one neutral(7N, 55%) and two acidic(7M, mono-, 43%; 7D, di-, 2%) sugar chain groups. 7N was finally separated into 5 chains(a, b, c, d, and e), respectively. The structure of this 2AB-neutral sugar chain was determined by sugar analysis, exoglycosidase digestion with OGS glycosidase Kit and OGS RAAM2000 system. The results show that fraction e was the same of reported 7N1A, the biantennary complex type with a fucose on reducing end and two N-acetyllactosamine branch on non-reducing end. Therefore, it was proved that OGS RAAM2000 method is in conformity with conventional analysis of sugar chain structure from bovine PAS-7.

  • PDF

A Development of Real Time Artificial Intelligence Warning System Linked Discharge and Water Quality (II) Construction of Warning System (유량과 수질을 연계한 실시간 인공지능 경보시스템 개발 (II) 경보시스템 구축)

  • Yeon, In-Sung;Ahn, Sang-Jin
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.7 s.156
    • /
    • pp.575-584
    • /
    • 2005
  • The judgement model to warn of possible pollution accident is constructed by multi-perceptron, multi layer neural network, neuro-fuzzy and it is trained stability, notice, and warming situation due to developed standard axis. The water quality forecasting model is linked to the runoff forecasting model, and joined with the judgement model to warn of possible pollution accident, which completes the artificial intelligence warning system. And GUI (Graphic User Interface) has been designed for that system. GUI screens, in order of process, are main page, data edit, discharge forecasting, water quality forecasting, warming system. The application capability of the system was estimated by the pollution accident scenario. Estimation results verify that the artificial intelligence warning system can be a reasonable judgement of the noized water pollution data.

Respiratory Chain-Linked Components of the Marine Bacterium Vibrio alginolyticus Affect Each Other

  • Kim, Young-Jae
    • Journal of Microbiology
    • /
    • v.40 no.2
    • /
    • pp.125-128
    • /
    • 2002
  • The aerobic respiratory chain of Vibrio alginolyticus possesses two different kinds of NADH oxidase systems, i.e., an $Na^{+}$-dependent NADH oxidase system and an $Na^{+}$-independent NADH oxidase system. When deamino-NADH, which is the only substrate for the $Na^{+}$-dependent NADH oxidase system, was used as a substrate, the maximum activities of $N^{+}$-dependent NADH: quinone oxidoreductase and $Na^{+}$-dependent NADH oxidase were obtained at about 0.06 M and 0.2 M NaCl, respectively. When NADH, which is a substrate for both $Na^{+}$-dependent and $Na^{+}$-independent NADH oxidase systems was used as a substrate, the NADH oxidase activity had a pH optimum at about 8.0. In cGntrastl when deamino-NADH was used as a substrate, the NADH oxidase activity had a pH optimum at about 9.0. On the other handle inside-out membrane vesicles prepared from the wild-type bacterium generated only a very small $\Delta$pH by the NADH oxidase system, whereas inside-out membrane vesicles prepared from Napl, which is a mutant defective in the $Na^{+}$ pump, generated $\Delta$pH to a considerable extent by the NADH oxidase system. On the basis of the results\ulcorner it was concluded that the respiratory chain-linked components of V. atginotyticus affect each other.

Research on Backup Protective Coordination for Distribution Network (네트워크 배전계통용 백업 보호협조에 관한 연구)

  • Kim, WooHyun;Chae, WooKyu;Hwang, SungWook;Kim, JuYong
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.1
    • /
    • pp.15-19
    • /
    • 2022
  • The radial distribution systems (RDS) commonly used around the world has the following disadvantages. First, when the DL is operated on a radial system, the line utilization rate is usually kept low. Second, if a fault occurs in the radial DL, a power outage of 3 to 5 minutes is occurring depending on the operator's proficiency and fault situation until the fault section is separated and the normal section is replaced. To solve this problem, Various methods have been proposed at domestic and foreign to solve this problem, and in Korea, research is underway on the advanced system of operating multiple linked DL always. A system that is electrically linked always, and that is built to enable high-speed communication during the protection coordination is named networked distribution system (NDS). Because the load shares the DL, the line utilization rate can be improved, and even if the line faults, the normal section does not need to be cut off, so the normal section does not experience a power outage. However, since it is impossible to predict in which direction the fault current will flow when a failure occurs in the NDS, a communication-based protection coordination is used, but there is no backup protection coordination method in case of communication failure. Therefore, in this paper, we propose a protective cooperation method to apply as a backup method when communication fails in NDS. The new method is to change TCC by location of CB using voltage drop in case of fault.