• Title/Summary/Keyword: LIMESTONE AREA

Search Result 284, Processing Time 0.225 seconds

Characteristics and Distribution Pattern of Carbonate Rock Resources in Kangwon Area: The Gabsan Formation around the Mt. Gachang Area, Chungbuk, Korea (강원 지역에 분포하는 석회석 자원의 특성과 부존환경: 충북 가창산 지역의 갑산층을 중심으로)

  • Park, Soo-In;Lee, Hee-Kwon;Lee, Sang-Hun
    • Journal of the Korean earth science society
    • /
    • v.21 no.4
    • /
    • pp.437-448
    • /
    • 2000
  • The Middle Carboniferous Gabsan Formation is distributed in the Cheongrim area of southern Yeongwol and the Mt. Gachang area of Chungbuk Province. This study was carried out to investigate the lithological characters and geochemical composition of the limestones and to find out controlling structures of the limestones of the formation. The limestones of the Gabsan Formation are characterized by the light gray to light brown in color and fine and dense textures. The limestone grains are composed of crinoid fragments, small foraminfers, fusulinids, gastropods, ostracods, etc. Due to the recrystallization, some limestones consist of fine crystalline calcites. The chemical analysis of limestones of the formation was conducted to find out the contents of CaO, MgO, Al$_2$O$_3$, Fe$_2$O$_3$ and SiO$_2$. The content of CaO ranges from 49.78-60.63% and the content of MgO ranges from 0.74 to 4.63% The contents of Al$_2$O$_3$ and Fe$_2$O$_3$ are 0.02-0.55% and 0.02${\sim}$0.84% , respectively. The content of SiO$_2$ varies from 1.55 to 4.80%, but some samples contain more than 6.0%. The limestones of the formation can be grouped into two according to the CaO content: One is a group of which CaO content ranges from 49.78 to 56.26% and the other is a group of which CaO content varies from 59.36 to 60.38%. In the first group, the contents of Al$_2$O$_3$, Fe$_2$O$_3$ and SiO$_2$ range very irregularly according to the CaO content. In the second group, the values of MgO, Al$_2$O$_3$, Fe$_2$O$_3$ and SiO$_2$ are nearly same. Detailed structural analysis of mesoscopic structures and microstructures indicates the five phase of deformation in the study area. The first phase of deformation(D$_1$) is characterized by regional scale isoclinal folds, and bedding parallel S$_1$ axial plane foliation which is locally developed in the mudstone and sandstone. Based on the observations of microstructures, S$_1$ foliations appear to be developed by grain preferred orientation accompanying pressure-solution. During second phase of deformation, outcrop scale E-W trending folds with associated foliations and lineations are developed. Microstructural observations indicate that crenulation foliations were formed by pressure-solution, grain boundary sliding and grain rotation. NNW and SSE trending outcrop scale folds, axial plane foliations, crenulation foliations, crenulation lineations, intersection lineations are developed during the third phase of deformation. On the microscale F$_3$ fold, axial plane foliations which are formed by pressure solution are well developed. Fourth phase of deformation is characterized by map scale NNW trending folds. The pre-existing planar and linear structures are reoriented by F$_4$ folds. Fifth phase of deformation developed joints and faults. The distribution pattern of the limestones is mostly controlled by F$_1$ and F$_4$ folds.

  • PDF

Origin of Massive Amphibolitic Rocks in Imgye Area, Korea (임계지역(臨溪地域)에 분포(分布)하는 각섬석질암(角閃石質岩)의 성인(成因))

  • So, Chil-Sup;Kim, Youn-Ki;Chi, Se-Jung;Park, Maeng-Eon
    • Economic and Environmental Geology
    • /
    • v.14 no.4
    • /
    • pp.183-191
    • /
    • 1981
  • Major and trace elements analyses are presented for 13 amphibolites by wet chemical and emission spectroscopic methods. These chemical data were compared with limestone and quartzite closely associated with the amphibolites. The chemical similarity of the amphibolites studied to the basic igneous rock and low oxidation ratios (<30) are indicative of the igneous intrusive, especially middle stage differentiates. Petrographic and stratigraphic study of the rocks suggest the more igneous features rather than those of sedimentary progenitors.

  • PDF

Talc Mineralization in the Middle Ogcheon Metamorphic Belt (II) : Poongjeon Talc Deposit (중부옥천변성대의 활석광화작용에 관한 연구 (II) : 풍전활석광상을 중심으로)

  • Park, Hee-In;Lee, In Sung;Hur, Soon Do;Shin, Dong Bok
    • Economic and Environmental Geology
    • /
    • v.30 no.6
    • /
    • pp.543-551
    • /
    • 1997
  • Poongjeon talc deposits is emplaced in dolomite and dolomitic limestone of the Cambro-Ordovician Samtaesan Formation. Ore in Poongjeon is low grade talc and the deposit has been known as the contact metasomatic or hydrothermal replacement type related to the intrusion of late Cretaceous granite in this area. X-ray diffraction, electron microprobe analysis, fluid inclusion and stable isotope analysis were utilized to examine the mineralogy of the ore and the origin of the ore fluid. The ore from Poongjeon mine mainly consists of talc and tremolite with minor amount of illite, vermiculite, smectite, and chlorite-vermiculite mixed layer. Occurrence of ore body indicates that the talc-tremolite ore was formed through the replacement by the $SiO_2$-rich hydrothermal fluid along the bedding and dike boundaries, or contact of amphibolite and basic dike with carbonate rocks. The temperature and pressure of the ore forming fluids at the time of the talc mineralization were estimated as $350^{\circ}C$ and 400 bar, respectively, based on the heating and freezing data of the fluid inclusions in quartz from talc-tremolite veins. During the talc-tremolite formation, fluids were divided into $CO_2$-enriched fluid and $CO_2$-poor fluid from $CO_2$ immiscibility (or effervescence). Oxygen isotope values (${\delta}^{18}O$) of the talc-tremolite fall within a range between 12.2 and 12.9‰. Hydrogen isotope values(${\delta}D$) of the ore range from -60 to -85‰ and $H_2O$ contents range from 2.0 to 3.4 wt.%. ${\delta}^{18}O$ and ${\delta}D$ values of talc ore indicate that the hydrothermal fluid involved in talc-tremolite formation was of igneous origin. Oxygen and hydrogen isotopic exchange between talc ore and the surface water was negligible after talc-tremolite ore formation.

  • PDF

Performance Enhancement of Flue Gas Desulfurization System with Structural Constraints in 500 MW Coal Fired Power Plants (구조적 제약조건을 갖는 500 MW 석탄화력발전소 탈황설비의 성능개선)

  • Kim, Jong-Sung;Yoo, Hoseon
    • Plant Journal
    • /
    • v.15 no.4
    • /
    • pp.30-35
    • /
    • 2019
  • To meet both increasing social demand for reduction of fine dust and the strengthened air pollutant emission standards, this paper indicated performance enhancement of FGD with structural constraints in 500 MW coal fired thermal power plant's. Through modifying internal facilities for flue gases to make swirl in the absorption tower, it made turbulence and increased the efficiency of material transfer, the reaction area and time with the limestone slurry. Therefore, it could reduce dust and enhance the performance of collecting the SO2. As a result, desulfurization efficiency was improved from 91.61% to 98.43% and dust removal efficiency was improved from 77.4% to 87.08%. Emission density is 7.85 ppm of SO2 and 4.67 mg/㎥ of dust. This is a level that satisfies emission limit of 25 ppm of SO2 and 5 mg/㎥ of dust which are the air pollutant emission standards of 2023. The performance enhancement method of this study is expected to be effectively applied to other coal-fired power plants with similar constraints.

Evaluating Effect of Density Flow from Upstream on Vertical Distribution of Water Quality at the Paldang Reservoir (팔당호 수질의 연직분포에 대한 밀도류 영향 평가)

  • Kong, Dongsoo
    • Journal of Korean Society on Water Environment
    • /
    • v.35 no.6
    • /
    • pp.557-566
    • /
    • 2019
  • Paldang is a river reservoir in the Midwest of Korea, which is a drinking water source for the metropolitan area. Since the Paldang Reservoir is shallow, and has a short hydraulic residence time, its water quality is directly impacted by two incoming rivers, the north Han River (NHR) and the south Han River (SHR). The NHR has different seasonal patterns of water temperature from the SHR because the NHR is greatly impacted by the discharge water from upstream dams. The electrical conductivity (EC) and other material concentrations of the SHR are usually higher than those of the NHR because its basin is limestone-based. The difference in water temperature in the two rivers causes density flow, and the distribution of the EC within the reservoir can be an indicator for monitoring density flow. From the vertical gradient of the EC at the dam site, from spring to fall, it was confirmed that the SHR flowed into the upper layer, and the NHR flowed into the lower layer, and vice versa at other times. The relative difference (RD) of the EC between the upper layer and the lower layer at the dam site was used as an indicator for density flow. The RD of the EC showed a very significant correlation with the RD of total organic carbon (r = 0.70, p < 0.001) and the RD of total nitrogen (r = 0.58, p < 0.01). This relationship is based on the assumption that the difference in electrical conductivity and water quality between the SHR and the NHR is constant. However, in many cases this assumption is inconsistent. Thus, further study is needed on more suitable indicators to evaluate the impact of density flow on water quality.

A Study on the Performance of Pipe Scale Cleaner using Natural Organic Acid (천연 유기산을 이용한 배관 스케일 세정제 성능에 관한 연구)

  • Kang, Hyung Seok;Yang, Won Suk;Kim, Young Il;Kim, Sean Hay;Choi, Dong Hee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.10
    • /
    • pp.530-537
    • /
    • 2017
  • Scales generated inside pipes cause negative effects on heat transfer performance, pressure loss and flow rate due to increased thermal resistance and reduced flow cross-sectional area. If these scales are not prevented or eliminated, thermal-fluid performance of the facilities can be deteriorated, or in extreme cases, accidents such as explosion due to overheating can occur. There are two ways to remove the scales, physically and chemically. Removing the scales physically needs specific machines which are expensive, and removing them chemically may provoke corrosion or shorten the age of the facilities. In this study, an eco-friendly pipe scale cleaner using natural organic acid is developed by applying the concept of a limestone cave generation. The manufactured scale cleaner is applied to remove the scales in industrial, water heating and urinal pipes. The results show that this cleaner removes scales more effectively and safely compared to existing scale treatments. Scale removal efficiencies of this work is 1.2~10.7 times for industrial pipes and 1.8~15.5 times for boiler water heating pipes higher than those of conventional cleaners.

Behaviour Characteristics of Tunnel in the Cavity Ground by using Scale Model Tests (축소모형실험을 이용한 공동지반에서의 터널 거동특성)

  • Chung, Jeeseung;Moon, Innki;Yoo, Chanho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.12
    • /
    • pp.61-69
    • /
    • 2013
  • As construction for road and train tunnel is increasing, various geotechnical conditions can be faced during the construction stage. Especially, if the tunnel is located in limestone area, the cavity is mostly to locate in tunnel planning location. One or some cavities which can be harmful for tunnel safety are predicted. Hence, this study was fulfilled to confirm the influence between tunnel and cavity using laboratory scale down model test and numerical analysis. The scale down model test was carried out to confirm the failure load of the model ground about the interval length of cavity and tunnel and to analyze behaviour characteristics of the model ground on the cavity shape. From the model test result, the failure load decrease in accordance with decreasing of interval length between cavity and tunnel within 0.5D. The numerical analyses were carried out for verification about scale down model test. From the numerical analysis result, tunnel safety decreases in the case of the interval between cavity and tunnel within 0.5D.

Numerical and Experimental Study on the Increase of Removal Efficiency of SO2 in a Laboratory Scale Electrostatic Spray Drying Absorber (실험실 규모 정전기 분무형 반건식 세정기의 SO2 제거효율 향상에 대한 계산 및 실험적 연구)

  • Byun, Young-Cheol;Hwang, Jung-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.8
    • /
    • pp.1111-1120
    • /
    • 1998
  • Spray Drying Absorber(SDA) system, where the combustion product gas is mixed with atomized limestone-slurry droplets and then the chemical reaction of $SO_2$ with alkaline components of the liquid droplets forms sulfates, has been widely used to eliminate $SO_2$ gas from coal fired power plants and waste incinerators. Liquid atomization is necessary because it can maximize the reaction efficiency by increasing the total surface area and dispersion angle of the alkaline components. First, numerical calculations using FLUENT are carried out to investigate $SO_2$ concentration distribution and thus to calculate $SO_2$ removal efficiency. So to attain the optimized spray conditions, then an electrostatic spraying system is set up and spray visualization is performed to show the effect of an electric field on overall droplet size. Next, the effect of an electric field on the concentrations of $SO_2$ is experimentally examined. Field strength is varied from -10 kV to 10 kV and configurations of conduction charging and induction charging are utilized. Consequently, the electrostatic removal efficiency of 501 increases about 30% with the applied voltage of ${\pm}10kV$ but is independent of polarity of the applied voltage. It Is also found that the conduction charging configuration results in higher efficiency of $SO_2$ removal that the induction charging configuration. Finally, the effect of slurry temperature on $SO_2$ removal is studied. The temperature influences on the electrostatic removal efficiency of $SO_2$.

Paleostress of the Joseon and Pyeongan Supergroups in South Korea using the New Calcite Strain Gauge (NCSG)

  • Jang, Bo-An;Ko, Chin-Surk;Kim, Jung-Han;Kim, Cheong-Bin;Kang, Seong-Seung
    • The Journal of Engineering Geology
    • /
    • v.24 no.3
    • /
    • pp.311-322
    • /
    • 2014
  • Limestone bodies under the tectonic environment have experienced various tectonic processes, and also changed the stress state. In this study, calcite twins found in limestones of the Joseon Supergroup and Pyeongan Supergroup in the northeastern part of the Ogcheon Belt, South Korea were measured, then the paleostress (i.e., the maximum shortening axis) was reconstructed using the new calcite strain gauge (NCSG) technique. The average twin thickness and average twin intensity increase as the total twin strain increases. We utilize the appearance of twins, the average twin thickness and average twin intensity, and the total twin strain to estimate that the observed calcite twins were produced at temperatures of < $200^{\circ}C$ in the Joseon Supergroup and $170^{\circ}C$ in the Pyeongan Supergroup. In the Joseon Supergroup, the dominant direction of the maximum shortening axis WNW-ESE to NW-SE; NE-SW shortening is also observed. The maximum shortening axes in the Pyeongan Supergroup are oriented NW-SE and NE-SW. The NE-SW direction of maximum shortening is associated with the occurrence of the Songrim orogeny of the Paleozoic to Early Jurassic, and the NW-SE direction of maximum shortening correlates to the Daebo orogeny of the Early Jurassic to Late Jurassic. It is thus concluded that the paleostress across the study area changed from NE-SW to NW-SE during the Mesozoic.

Calculation of a Diesel Vehicle's Carbon Dioxide Emissions during Haulage Operations in an Underground Mine using GIS (GIS를 이용한 지하광산 디젤 차량의 운반작업 시 탄소배출량 산정)

  • Park, Boyoung;Park, Sebeom;Choi, Yosoon;Park, Han-Su
    • Tunnel and Underground Space
    • /
    • v.25 no.4
    • /
    • pp.373-382
    • /
    • 2015
  • This study presents a method to calculate carbon dioxide emissions of diesel vehicles operated in an underground mine using Geographic Information Systems (GIS). An underground limestone mine in Korea was selected as the study area. A GIS database was constructed to represent the haulage roads as a 3D vector network. The speed of dump trucks at each haulage road was investigated to determine the carbon dioxide emission factor. The amount of carbon dioxide emissions related to the truck's haulage work could be calculated by considering the carbon dioxide emission factor at each haulage road and the haulage distance determined by GIS-based optimal route analysis. Because diesel vehicles are widely utilized in the mining industry, the method proposed in this study can be used and further improved to calculate the amount of carbon dioxide emissions in mining sites.