• Title/Summary/Keyword: LIM Pump

Search Result 271, Processing Time 0.028 seconds

The Performance Analysis of Sea Water Heat Pump applied Low GWP Refrigerants (Low GWP 냉매를 적용한 해수열 히트펌프의 성능해석)

  • Lim, Seung-Taek;Kim, Hyeon-Ju;Lee, Ho-Saeng
    • Journal of Power System Engineering
    • /
    • v.20 no.5
    • /
    • pp.92-97
    • /
    • 2016
  • In this study, the seawater Heat Pump System using seawater with temperature of annual domestic conditions ($0^{\circ}C$ to $25^{\circ}C$) is designed in order to compare its performance against the Heat Pump using unused heat of seawater. As a potential replacement for current refrigerants that exacerbate global warming and ozone delpetion, a Low GWP refrigerant's performance is analyzed. The basic water to water Heat Pump system is chosen and three commercial refrigerants - R134a, R410a, R32 - are used to compare against new Low GWP refrigerant R1234ze. When seawater with temperature of $25^{\circ}C$ is used, the performance change showed maximal increase in COP, 38.3%. low GWP refrigerant R1234ze, showed great performance characteristics reach to 5.242 and Existing commercial refrigerant, R134a showed only less than 0.03 performance difference against R1234ze. The study confirms notable performance of R1234ze refrigerant through simulation as environmentally friendly refrigerant for domestic seawater Heat Pump.

A Study on the Internal Flow Analysis in Swash Plate Piston Pump for Marine Hydraulic Power Supply (선박 유압공급 장치용 사판식 유압 피스톤 펌프 내부 유동해석에 관한 연구)

  • Yi, Chung-Seob;Lee, Jeong-Sil;Lim, Jong-hak;Gwak, Beom-Seop;Lee, Ho Seong;Song, Chul Ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.1
    • /
    • pp.34-40
    • /
    • 2022
  • In this paper, a flow analysis of a swash-plate type hydraulic piston pump installed on a hydraulic flow supply system for marine vessels is presented. A model and governing equations for computational fluid dynamics (CFD) analyses of swash-plate type hydraulic piston pumps were built, and simulation results regarding the internal flow field of the pump were obtained. By analyzing the internal flow of the swash-plate type hydraulic piston pump, we can confirm the time-dependent stroke of each piston as the pump rotates. We also verified that by analyzing the pulsating flow against the slope of the swash plate, the simulation results match well with the experimental results. The natural frequency of the system was computed to be approximately 380 Hz by applying and analyzing the fast Fourier transform (FFT) of each swash plate slope evaluated.

Experimental Verification of Spur Gear Pump based on FEM Analysis (FEM해석 기반 스퍼기어 펌프의 실험적 검증에 대한 연구)

  • Lee, Chan-Woo;Kim, Sang-Yu;Lee, Seo-Han;Kim, Jae-Yeol;Lim, Jin-Hyuk
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.6
    • /
    • pp.1-7
    • /
    • 2022
  • This work investigated the performance improvement of a medium-pressure fixed-displacement-type SPUR gear pump, which is mainly used in the machine tool industry. The 3D CFX analysis and IS technique were applied using ANSYS (commercial FEM code) and compared with experimental results to ensure the reliability of the analysis. In addition, the performance improvement of the pump was obtained using the theoretical volumetric displacement equation, and the gear tooth width was changed. The pressure flow performance curves were compared, and the results were analyzed according to the width of the gear teeth. This is a factor that can cause irregular flow, vibration, and noise inside the gear pump owing to friction between the housing and gear pump.

Chemiluminescence System with Air Pump as a Sensor for Determination of Metal Levels in Rain

  • Hong, Hyuck-Gi;Lim, H.B.
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.12
    • /
    • pp.1937-1940
    • /
    • 2005
  • A lab-made chemiluminescence system with air pump was developed for monitoring of some metal levels in rain. The air pump enabled injection of 17.7 $\mu$g samples into a glass cell filled with luminol-$H_2O_2$ reagent of typically 300 $\mu$L for chemiluminescence measurement. The monitored trend of total metal ions in the rain collected in our campus was compared with analytical results of each metal ion from GFAAS. The system was also demonstrated to determine $Cr^{6+}$ by reduction to $Cr^{3+}$ using $SnCl_2$. The limit of detection for $Cr^{6+}$ obtained by 4 measurements was 85.0 pg $mL^{-1}$ with a relative standard deviation of 3.4%. Although this system doesn’t have selectivity due to the characteristics of chemiluminescence, application of it to environmental monitoring as a sensor for some transition metal ions was demonstrated.

보일러 급수 펌프의 과도진동 연구 사례 - 실험 및 신호처리를 중심으로 -

  • Kim, Jeung T.;Lim, Byung-Duk;Lee, Hyun
    • Journal of KSNVE
    • /
    • v.1 no.2
    • /
    • pp.129-140
    • /
    • 1991
  • The boiler feed pump located at a power plant has been experienced a severe vibration since the plant began to service in early 1980. The research is focused on the field measurement and implementation of simple signal processing techniques in order to provide realistic and effective solution which could be implemented into the plant. Based on the root cause analysis for the trouble-making pump system, the driving part gear in the fluid coupling system is identified as a potential source. The followed verification test confirms the analytical result. The test result shows that vibration reduction obtained after the gear replacement reaches up 15.8 dB, which is 1/6 times of the vibration level compared to that of the troble-making pump. The measured vibration level of the pump satisfies the manufacture criteria and guarantees the smoothed operation.

  • PDF

A study for a Performance analysis of Hybrid heat pump Air conditioning system (복합열원형 히트펌프 냉난방 시스템의 성능분석에 관한 연구)

  • Lim, Hyun-Mook;Park, Hee-Moon;Cho, Soo;Sung, Uk-Joo;Park, Jin-Hoon;Park, Tae-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1373-1378
    • /
    • 2009
  • This study is aiming comparison and analization between efficiency of hybride air conditioning system which uses low temperature water under dam and air and EHP(Electric Heat Pump). The experimental was carried out with air cooling tests for EHP system having 80HP and composition heat pump system. P-i diagram of both systems and COP was used to derive schemetic and calcuations. As results of the tests, hybride system has 1.4 time higher efficiency coefficient.

  • PDF

A Study on Identification of Open Area of Pump for Hydraulic Excavator (유압 굴삭기용 펌프의 개구면적 규명에 관한 연구)

  • Lim T.H.;Oh B.S.;Lee H.S.;Yang S.Y.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.101-102
    • /
    • 2006
  • The purpose of this paper is pulsation-analysis of the swash plate type axial piston pump for excavator and the method of side branch hose application, which is used normally in construction equipments. In this paper, draw the mathematical modeling for pressure pulsation mechanism of the swash plate type axial piston pump for excavator, expression the flow pulsation in the pipelines by transfer matrix method, programmed simulation for pulsation by AMEsim software, and the reliability of that was verified by the comparison with the experimental results.

  • PDF

Wrapping of an Ascending Aortic Aneurysm with the Multiple Boot-Straps Technique in a Patient Undergoing Off-Pump Coronary Artery Bypass Grafting

  • Na, Kwon Joong;Kim, Jun Sung;Park, Kay-Hyun;Lim, Cheong
    • Journal of Chest Surgery
    • /
    • v.48 no.3
    • /
    • pp.206-209
    • /
    • 2015
  • Ascending aortic aneurysms are usually treated with graft replacement under cardiopulmonary bypass. However, if a candidate for off-pump coronary artery bypass grafting has an enlarged ascending aorta, surgeons may consider wrapping it without cardiopulmonary bypass. Here, we report a 78-year-old female who underwent successful wrapping of the ascending aorta concomitant with off-pump coronary artery bypass grafting, using a new wrapping technique that involves multiple bootstraps.

Performance Characteristics of Side Channel Type Regenerative Pumps (사이드채널형 재생펌프의 성능 특성에 관한 실험적 연구)

  • Kang Shin-Hyoung;Lim Hyung-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.3 s.234
    • /
    • pp.306-313
    • /
    • 2005
  • The performance of a regenerative pump is affected by many parameters, especially blade shape of impeller, leakage flow in the clearance and head losses at the inlet & outlet. An impeller with J-shape blade was designed and 5 times scale up model was tested at similarity conditions to evaluate the performance. Performance variations with clearance change were executed. The amounts of leakage flow through the clearance were estimated using the one-dimensional leakage flow models and analysis. Main leakage flow is generated through the gap between the impeller and casing. The inlet & outlet head losses were also estimated. Such corrections are very important to evaluate the final performance of the impeller and pump. Cavitation test was also performed at 1,200 rpm. NPSH of the regenerative pump was obtained and growth of cavity within blades was visualized.

Dynamic Response of the System for Vacuum Pump Performance Evaluation (진공 펌프 성능 평가 계통의 동적 응답)

  • Sim, Woo-Gun;Lim, Jong-Yeon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.11
    • /
    • pp.1359-1367
    • /
    • 2004
  • The demand of vacuum pump has been increased in the process of semi-conduct manufacturing, as a core component. The response of the system for vacuum pump performance test can be utilized to assess the system and to obtain the reliability of the apparatus for the test. The system consists of gas supply tank, pressure chamber, measurement chamber and transmission line. Transient analysis for compressible fluid has been conducted to evaluate the dynamic characteristic of the volume terminated transmission line. Numerical approach based on the method of characteristics is used for the analysis. The response is evaluated with the important parameters for the system: i.e., length and diameter of the line, volume of the terminal tank. Using the numerical results, pumping speeds are calculated and then compared to the experimental results.