• Title/Summary/Keyword: LIDMOD2

Search Result 7, Processing Time 0.024 seconds

LIDMOD2 Development for Evaluation of LID/BMPs (LID/BMPs 효과분석을 위한 LIDMOD2 개발)

  • Jeon, Ji-Hong;Choi, Donghyuk;Na, Eun Hye;Park, Chan-Gi;Kim, Tae-Dong
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.3
    • /
    • pp.432-438
    • /
    • 2010
  • LIDMOD2 was developed for evaluation of low impact development (LID) and best management practice (BMP) by modification of Site Evaluation Tool (SET). The modification includes employment of SCS-CN method for annual runoff simulation, unit load method for annual pollutant loads simulation, and the method proposed by Korean TMDL for calculating pollutant reduction by BMPs. The CN values were updated with regionalized parameters within Nack-Dong River basin because these are important parameters for simulating hydrology. LIDMOD2 was tested by applying to Andong Bus terminal. As a simulation results, pollutant loads and surface runoff will be significantly increased by post-development without LID compared with those from pre-development. LID technique was simulated to efficiently reduce surface runoff and pollutant load and increase infiltration. LIDMOD2 is screening level tool and easy to use because LIDMOD2 is based on spread sheet and most of parameters are regionalized. LIDMOD2 was illustrate that it could evaluate LID well by summarizing and graphing annual hydrology, annual pollutant loading, and hydrograph for event storm. The calculation methods related with pollutant loads are employed from the guideline of Korean TMDL and it can be useful tool for Korean TMDL to evaluate the effect of LID/BMP on developing area.

LIDMOD Development for Evaluating Low Impact Development and Its Applicability to Total Maximum Daily Loads (지속가능한 도시개발을 위한 LID평가모델(LIDMOD)개발과 수질오염총량제에 대한 적용성 평가)

  • Jeon, Ji-Hong;Choi, Dong Hyuk;Kim, Tae Dong
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.1
    • /
    • pp.58-68
    • /
    • 2009
  • Low impact development (LID) technique is relatively new concept to reduce surface runoff and pollutant loading from land cover by attempting to match predevelopment condition with various integrated management practices (IMPs). In this study, computational model for designing and evaluating LID, named LIDMOD, was developed based on SCS-CN method and applied at Andong bus terminal to evaluate LID applicapability and design retention/detention area for volume or peak flow control. LIDMOD simulated with 21 years simulation period that yearly surface runoff by post-development without LID was significantly higher than that with LID showing about 2.8 times and LID could reduce efficiently yearly surface runoff with 75% reduction of increased runoff by conventional post development. LIDMOD designed detention area for volume/peak flow control with 20.2% of total area by hybrid design. LID can also efficiently reduce pollutant load from land cover. Pollutant loads from post-development without LID was much higher than those from pre-development with showing 37 times for BOD, 2 times for TN, and 9 times for TP. Pollutant loads from post-development with LID represented about 57% of those without LID. Increasing groundwater recharge reducing cooling and heating fee, creating green refuge at building area can be considered as additional benefits of LID. At the point of reducing runoff and pollutant load, LID might be important technique for Korean TMDL and LIDMOD can be useful tool to calculate unit load for the case of LID application.

Design of Structural BMPs for Low Impact Development (LID) Application and Modelling Its Effect on Reduction of Runoff and Nonpoint Source Pollution: Application of LIDMOD2 (저영향개발(LID)적용을 위한 구조적 BMPs의 유출량 및 비점오염저감 효과모의: LIDMOD2 적용)

  • Kim, Jung Jin;Kim, Tae-Dong;Choi, Donghyuk;Jeon, Ji-Hong
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.5
    • /
    • pp.580-586
    • /
    • 2011
  • Low impact development (LID) technique is recently proposed as new concept to reduce surface runoff and pollutant loading with various best management practices (BMPs). In this study, LIDMOD2, which is one of the model to evaluate LID, was applied at Mohyeon developing area to evaluate the redcution of annual runoff and pollution loading, cost-reduction efficient by LID with design of structural BMPs including bioretention, wet pond, and wetland. As a simulation results, the bioretention had the highest reduction efficiency for runoff (41.43%), and 22% for T-N and 22% for BOD. Wet pont had the highest reduction efficiency for T-P as showing 25% of reduction rate. As a results of cost-reduction efficient, wet pont represented the highest cost-effective for T-N and BOD with showing 0.43 T-P kg/million won and 17.37 BOD kg/million won, respectively, and bioretention represented the highest cost-effective for T-P with showing 2.52 T-P kg/million won. LID technology could reduce effectively surface runoff and nonpoint source pollution and construct sustainable development. LIDMOD2 could be suggested as useful tool to evaluate and design LID.

The Effects of Infiltration Rate of Foundation Ground Under the Bioretention on the Runoff Reduction Efficiency (식생체류지의 원지반 침투율이 유출량 저감효과에 미치는 영향모의)

  • Jeon, Ji-Hong;Jung, Kwang-Wook
    • Journal of Korean Society on Water Environment
    • /
    • v.35 no.1
    • /
    • pp.72-77
    • /
    • 2019
  • Soil type in LID infiltration practices plays a major role in runoff reduction efficacy. In this study, the effects of infiltration rate of foundation ground under bioretention on annual runoff reduction rate was evaluated using LIDMOD3 which is a simple excel based model for evaluating LID practices. A bioretention area of about 3.2 % was required to capture surface runoff from an impervious area for a 25.4 mm rainfall event. The relative error of runoff from bioretention using LIDMOD3 is 10 % less than that of SWMM5.1 for a total rainfall event of 257.1 mm during the period of Aug. 1 ~ 18, 2017, hence, the applicability of LIDMOD3 was confirmed. Annual runoff reduction rates for the period 2008 ~ 2017 were evaluated for various infiltration rates of foundation ground under the bioretention which ranged from 0.001 to 0.600 m/day and were converted to annual runoff reduction for hydrologic soil group. The runoff reduction rates within hydrologic soil group C and D were steeply increased through increased infiltration rate but not steep within hydrologic A and B with reduction rates ranging from 53 ~ 68 %. The estimated time required to completely empty a bioretention which has a storage depth of 0.632 m is 3.5 ~ 6.9 days and we could assume that the annual average of antecedent rainfall is longer than 3.5 ~ 6.9 days. Therefore, we recommended B type as the minimum hydrologic soil group installed LID infiltration practices for high runoff reduction rate.

The development of land use planning technique applying low impact development and verifying the effects of non-point pollution reduction : a case study of Sejong city 6 district (저영향개발(LID)을 적용한 토지이용계획 기법 개발 및 적용효과 분석 : 세종시 6생활권을 대상으로)

  • Kang, Ki-Hoon;Lee, Kyung-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.7
    • /
    • pp.548-553
    • /
    • 2017
  • The aim of this study was to develop a low impact development design technique that can be applied in the land use planning stage and verify quantitatively the effects of non-point pollution reduction. For this purpose, the low impact development design elements that can be applied in the land use planning stage were derived and applied to an actual site, and the non-point pollution reduction effect was analyzed using the LIDMOD2 program. The analysis showed that the permeability rate of the land use plan using low impact development decreased by 19.8% compared to the existing land use plan. In addition, annual surface runoff decreased by 19.0% and annual infiltration increased by 164.1%. In the case of non-point pollution, the annual loading, T-N, T-P, and BOD decreased by 18.7 ~ 22.8%. Therefore, compared to the existing land use plan, the land use plan using low impact development has a considerably large effect of reducing the non-point pollution without changing the floor area according to each application. Therefore, to maximize the reduction effect of non-point pollution, it will be necessary to establish a related plan by applying the low impact development technique from the land use planning stage to the existing LID facility-oriented plan.

The Planning Process and Simulation for Low Impact Development(LID) in Waterfront Area (수변지역에서의 저영향개발기법(LID) 적용을 위한 계획과정 도출 및 모의효과)

  • Kim, Dong Hyun;Choi, Hee-Sun
    • Journal of Environmental Policy
    • /
    • v.12 no.1
    • /
    • pp.37-58
    • /
    • 2013
  • In recently, the low impact development(LID) is discussed at various fields being related to urban stormwater, non-point source pollution, and quality of life. It is understood as an integrated development tool to induce sustainable development with various value-social, economic, and aesthetic. As concerning the development of waterfront area, the low impact development is interested in environmental planning. But the planning process and factors are not considered in precedent research. This study has two purposes. The one is to understand the planning process and factors of low impact development from literature review. The other is to apply the planning factors using case study and to know the effect of low impact development as the simulation plan. The simulation plan is based on some landuse planning. It is divided into the setting the region for environmental protection and the function of public facilities, spatial planning for enlarging permeable area, and spatial planning for circulation of water. The simulation model uses the LIDMOD2. The 14 planning factors of low impact development is applied to case region. And the effect is about 7~10 percent in reduction of nonpoint source pollution and surface runoff.

  • PDF