• Title/Summary/Keyword: LENS

Search Result 3,842, Processing Time 0.032 seconds

A study on using practice of contact lens and side effects (연성콘택트렌즈 착용자의 실태와 부작용에 대한 연구)

  • Kang, Hyang Nyeo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.1
    • /
    • pp.69-73
    • /
    • 2002
  • This questionnaire studied the status of wear and care for soft contact lens, of 200students wearing loft contact lens. 50% of man wore soft contact lens, 8 hours and 52% of woman wore soft contact lens 10 hours per a day, 51% of man has worn soft contact lens 3 years 45% of woman has worn soft contact lens 3 year. For the side effects of wearing contact lens 39% of man soft contact lens wearers experienced eye congestion, 72% of woman soft contact lens wearers dryness eyes.

  • PDF

The Study on the Manufacturing and Inspection of Aspheric Lens using Automatic Design Program (자동설계 프로그램을 이용한 비구면 렌즈의 가공 및 검증에 관한 연구)

  • Kim Soo Yong;Han Min Sik;Kim Se Min;Kim Tea Ho;Jeon Eon Chan
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.197-202
    • /
    • 2005
  • An aspheric lens is one of a key point optical element in the optical industry. The feature of an aspheric lens is not to have the spherical aberration. An aspheric lens is also essential element for high-precision and light-weight in the optical machine. Generally it have been used in a tailor progression an aspheric lens modelling much. In this study we applied a lay back-tracer using a index of refraction to draw a creative aspheric lens. Also we developed the automatic design program for aspheric lens. We manufactured the aspheric lens and executed a comparison experiment for refraction situation of shape and straightness experiment to inspect the drawn aspheric lens in this study.

  • PDF

Force Control of Small Lens Molding System (소형렌즈 성형시스템의 힘제어에 관한 연구)

  • Kim, Gab-Soon;Kuk, Gum-Hwan;Shin, Hyi-Jun;Kim, Hyeon-Min;Jung, Dong-Yean
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1091-1096
    • /
    • 2007
  • This paper describes the development of a small lens molding system for manufacturing the small lens like lens of a cellular phone, a small digital camera and so on. In order to manufacture a small lens, firstly, the raw material for lens with spherical shape should be manufactured by processing a glass, secondly, the mold inserted the raw material for lens should be heated till its molding temperature in the electric furnace, finally, the small lens is manufactured by applying the force using pressuring control system. In this paper, the small lens molding system with the function of force control and velocity control was developed. It is composed of a electric furnace and its temperature control system, a pressuring control system, a body, and so on. The temperature characteristic test of the electric furnace, and the force and velocity characteristic test of the pressuring control system were carried out. It was confirmed that the developed system had good functions for manufacturing a small lens.

  • PDF

Development of Molding System for Manufacturing a Small Lens and Its Force Control (소형렌즈 성형시스템 개발 및 힘제어에 관한 연구)

  • Kuk, Gum-Hwan;Jung, Dong-Yean;Kim, Gab-Soon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.2
    • /
    • pp.57-64
    • /
    • 2008
  • This paper describes the development of a small lens molding system for manufacturing the small lens like lens of a cellular phone, a small digital camera and so on. In order to manufacture a small lens, firstly, the raw material for lens with spherical shape should be manufactured by processing a glass material, secondly, the mold inserted the raw material for lens should be heated till its molding temperature in the electric furnace, finally, the small lens is manufactured by applying the force using pressuring control system. In this paper, the small lens molding system with the function of force control and velocity control was developed. It is composed of an electric furnace and its temperature control system, a pressuring control system, a body, and so on. The temperature characteristic test of the electric furnace, the force and velocity characteristic test of the pressuring control system were carried out. It was confirmed that the developed system had good functions for manufacturing a small lens.

The Micro Lens Mold Processing in Mechanical Fabrication Method (기계적인 가공방법에 의한 마이크로 렌즈 금형가공)

  • 정재엽;이동주;제태진;최두선;이응숙;홍성민
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1885-1888
    • /
    • 2003
  • As high technology industries such as IT and display have developed, demand for application parts of micro lens and lens array has been extremely increasing. According to these trends, many researchers are studying on the fabrication technology for parts of the micro lens by a variety of methods such as MEMS, Lithography, LIGA and so on. In this paper, we have performed researches related to ultra precision micro lens, lens array mold and fabrication of Lenticular lens mold for three-dimensional display by using mechanical micro end-milling and fly-cutting fabrication method. Tools used in this research were a diamond tool of R 150$\mu\textrm{m}$. Cutting conditions set up feed rate, spindle revolution. depth of cut and dwell time as variables. And we analyzed surface quality variation of the processed products according to the cutting conditions, and then carried out experiments to search the optimum conditions. Through this research, we have confirmed that we can fabricate the ultra precision micro lens mold with surface roughness Ra=20nm and the holographic lens mold by using micro end-milling and fly-cutting fabrication method. Furthermore, we demonstrated problems happened in the fabrication of the micro lens and established the foundation of experimental study for formulating its improvement plan.

  • PDF

Changes in Subjective Discomfort, Blinking Rate, Lens Centration and the Light Transmittance of Lens Induced by Exceeding Use of Daily Disposable Circle Contact Lenses in Dry Eyes (일회용 써클소프트렌즈의 일일 초과착용 시 유발되는 건성안의 자각적 불편감, 순목횟수, 중심안정 및 렌즈 광투과율의 변화)

  • Park, Mijung;Kang, Shin Young;Chang, Jung Iee;Han, Arum;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.153-162
    • /
    • 2014
  • Purpose: This study was assessed to investigate the change of subjective and/or objective symptoms and the light transmittance of lens caused by the use longer than recommended wearing time of daily disposable circle contact lenses (circle lens) in dry eyes. Methods: Three daily disposable circle lenses made of etafilcon A, hilafilcon B, and nelfilcon A were applied on 30 dry eyes with smaller tear volume than normal eyes in their twenties free from any eye diseases by when subjects complained any kind of discomfort. On the first and the last days of lens wearing, subjective discomfort, blinking rate, lens centration on corneal surface and visible light transmittance of lens were recorded at every case and compared. Results: The circle lens wearers complained subjective discomfort and quit the lens wearing when they wore the circle lens longer than 10 hours even though there were some difference according to the lens materials of daily disposable circle lens. However, around 20% of dry eyes could wear the circle lens made of non-ionic materials longer than 40 hours. Dry eyes showed most sensitive feeling of subjective discomfort against the circle lens made of etafilcon A among three different lens materials. On the last day of lens wearing, the representative subjective discomforts were irritation, stiffness, dryness and tiredness. When the subjects wore circle lens more than the recommended time, blinking rate was significantly increased about 20~30% regardless of lens materials when it compared with the values right after lens wearing. On the last day of lens wearing, the vertical direction of lens centration was shifted to pupil center however, its distribution in horizontal direction was wide compared with the distribution right after lens wearing. Especially, the centration of etafilcon A lens was unstable. Furthermore, the visible light transmittance of 3 different circle lenses in dry eyes has significantly been reduced around 15% averaged. Conclusions: From these results, it was known that the increase of dryness and stiffness caused by overusage of daily disposable circle lens induced excess irritation and decreased visible light transmittance and caused significant more blinking, which provoked lens decentration. It was also revealed that dry eyes showed sensitive reaction subjectively and objectively against the overusage of circle lens made of high water content/ionic lens material even there were some difference of the degree depending on the individual and the lens material. Thus, this research can be suggested as the basic reference for the education about some unexpected problems and the side effect caused by the wearing of circle lens in dry eyes.

The Performance Analysis and Design of Selling Spectacle Lenses in Domestic Market (국내 시판 안경렌즈의 성능 분석 및 설계)

  • Kim, Se-Jin;Lim, Hyeon-Seon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.4
    • /
    • pp.355-360
    • /
    • 2010
  • Purpose: Analysis performance for spectacle lens which sales in domestic market and optimization design a spectacle lens which is corrected aberration. Methods: Measured center thickness, radius and aspherical surface coefficient for spherical and aspherical lenses which were ${\pm}$5.00D. Refractive index for every lens was 1.6 and they came from 4 different companies. I used 3 types of equipment to measure lenses. ID-F150 (Mitutoyo) : Center Thickness, FOCOVISION (SR-2, Automation Robotics) : Radius, PGI 1240S (Taylor Hobson) : Aspherical surface coefficient. Designed a lens which had 27 mm of distance from lens rear surface to center of eye, 4 mm of pupil diameter and small aberration on center vision $30^{\circ}C$. To shorten axial distance compared with the measured lens rise merits for cosmetic. Lens Design tool was CODE V (Optical Research Associates). Results: -5.00D aspherical lens had somewhat high astigmatism and distortion compared with the spherical lens. But it had a merit for cosmetic because of short axial height and decrease edge thickness. Improved a performance of distortion and ascertain merits for cosmetic due to short axial height and decrease edge thickness same as (-) lens in case of +5.00 aspherical lens. Though an optimization process front surface aspherical lens had a good performance for astigmatism and distortion and the merit for beauty compared with measured spherical lens. Conclusions: Design trend for domestic aspherical lens is decrease axial height and thickness to increase a merit for cosmetic not but increase performance of aberration. From design theory for optimization design front surface aspherical spectacle lens which has improved performance of aberration and merit for cosmetic at the same time compared with the measured lens. Expect an improved performance from design back aspherical lens compared with front aspherical lens.

A Study on Improvement of Wettability and Comfort in Contact lens with Hyaluronic acid (Hyaluronic acid 함유 콘택트렌즈의 습윤성과 착용감 향상 효과 연구)

  • Kim, Hyun Jung;Kim, Soo-Hyun;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.255-264
    • /
    • 2011
  • Purpose: To study the effect of hyaluronic acid(HA), which was widely used in artificial tears, multi-purpose solution(MPS), cosmetics, and drug acting on the musculo-skeletal system, in wettability and comfort of contact lens, we compared HA including lens(+HA) with HA excluding lens(-HA) by clinical evaluation. Methods: During four weeks, the selected 28 university student volunteers who did not have any eye disease wore +HA contact lens on their right eyes, and -HA contact lens on their left eyes, and then compared right eyes to left eyes as control. After prescribing by spherical equivalent calculation, over-refraction by auto-refractometer, and contact lens wearing for two weeks and four weeks, tear evaluation, the anterior of eyes examination, fitting convenience evaluation, surface wetting test, surveys were checked up. Results: Compared with the control group (-HA contact lens), +HA contact lens provided better wetting properties. The amount of released tear in -HA contact lens group became less in four weeks than before, but that in +HA contact lens group showed no significant difference from the initial one. In terms of the redness in eye, there was no significant difference between +HA and -HA contact lens groups. Fitting of +HA contact lens on eye was much easier than the control, -HA contact lens. From the results of survey, comfort, wettability, ease of cleaning, and dryness of eye in +HA contact lens group were generally better than those of -HA group, but redness and contact lens handling showed little difference. Conclusions: The addition of HA in soft contact lens(+HA) may enhance the wettability of lens during lens wearing, resulted in the better comfortable wearing of lens eventually.

Fundamentals of Tight fitted Contact Lens Movement (Tight Fit 콘택트렌즈 운동의 기초)

  • Kim, Dae Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.3
    • /
    • pp.17-27
    • /
    • 2009
  • Purpose: This review article was written to determine the effects of parameters characterizing a hard contact lens (RGP included), such as BCs, diameters, edge angles, on the time interval for tight fitted lens to return to the equilibrium when it was decentered from blinking. Methods: A mathematical formulation was established to relate or calculate the restoring forces and thickness of lacrimal layer beneath the cornea with the various lens parameters when the tight fitted lens was decentered from blinking. Based on this formulation the differential equations and their numerical solution program were set up to describe the time dependence of the lens on the position and to estimate the time for the lens's return to the equilibrium after blink. Results: It is found that the time interval for the tight fitted lens to return to the equilibrium decreases as either the BC decreases or the diameter increases because both the reduction in BC and increase in diameter result in the increase in the lacrimal layer thickness between the lens and cornea increase which yielded the lowering of the viscous friction in the lens motion. As the edge angle of tight fitted lens increases the time for recentering decreases due to the increase in restoring force without change in lacrimal thickness beneath the lens. In the case of flat fitted hard lens (RGP included), the lacrimal layer thickness under the lens increases as either BC or diameter increases which results in reduction in viscous friction so that the time for the lens's return to the equilibrium were to decrease. The edge angle of flat fitted lens does not affect the lens motion. Conclusions: The effect of BCs on the lens motion (time to approach the equilibrium) was concluded to be significant with both tight and flat fitted lens where its results are contrary with each other. The edge angle of lens only affects the motion in tight fitted lenses.

  • PDF

The Contamination Level of Lens Cases by Various Wearing and Storage Periods of Soft Contact Lens and the Actual Condition of Lens Cases Care (소프트 콘택트렌즈 착용 기간과 보관 기간에 따른 보관 용기의 오염도 및 보관 용기 관리 실태)

  • Kim, So Ra;Shin, Sang Mok;Park, Jong Ae;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.135-145
    • /
    • 2011
  • Purpose: This study was conducted to investigate the actual condition of caring soft contact lens cases and the change in contamination level of lens cases by wearing and storage period of soft contact lens. Methods: The actual condition of caring soft lens cases was surveyed with sixty-three of contact lens wearers. Soft contact lenses were worn for 1, 3, 7 and 14 days, and the lenses were separately stored in 12 lens cases for 1, 3 and 7 days. The contamination level of lens cases was determined by counting the numbers of microorganisms, gram negative bacteria and fungi. Results: Only 14% of survey answerers cleaned their lens cases with a brush, rinsed and dried them upside down before next usage of lens case when those lenses were kept for a long time. Furthermore, 54% of total answerers just kept soft contact lens in the case without changing the multipurpose solution. Microorganisms, gram negative bacteria and fungi were detected in lens cases even when soft contact lens were kept for 1 day in the lens case after wearing for 1 day and cleaning it with multipurpose solution. The numbers of microorganisms, gram negative bacteria and fungi in lens cases increased with storage periods of soft contact lens, and also contamination level of lens cases was increased in accordance with wearing period of lens. In the lens cases without changing multipurpose solution, the numbers of microorganisms, gram negative bacteria and fungi increased with storage period of lens with statistical significance. Conclusions: This study showed that lens wearers' concerns on caring contact lens case were not satisfactory. As the result, the contamination of lens cases was related to increase of lens wearing and storage periods suggesting that the proper instruction and education for lens wearers are required.