Study on Analysis of Characteristics of Illuminance and Luminance Distribution of LED Luminaires (LED 조명기구의 조도.휘도분포 특성 분석에 관한 연구)

  • Lee, Jin-Sook;Kim, Won-Do;Kim, Byoung-Soo;Han, Won-Tak
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.9
    • /
    • pp.1-7
    • /
    • 2008
  • This study is intended to compare physical properties of fluorescent luminaires with ones of LED luminaires so as to analyze fundamental characteristics of LED luminaires. For this, a comparative analysis of uniformity ratio of illuminance and luminance distribution of these two luminaires was made, and materials for applying LED luminaires to interior construction space were prepared. This study was carried out in four stages. First, a theoretical review on LED illumination light source was made compared with the existing luminaires. Second, a mock-up to control experimental variables to meet the objective of this study was manufactured. Third uniformity ratio of illuminance and luminance distribution of each luminaire were measured by using the mock-up. Fourth, a comparative analysis of uniformity ratio of illuminance and characteristics of luminance distribution of the existing fluorescent luminaires and LED ones was made. As a result of the study, the uniformity ratio of illuminance of LED luminaires, 0.559, was higher than one of the existing fluorescent luminaires, 0.522. Namely, it was shown that illuminance distribution of LED luminaires was uniform and global diffuse was good. As a result of measuring luminance distribution, it was found that luminance distribution of LED luminaires was more uniform than one of the existing fluorescent luminaires. The maximum luminance of fluorescent luminaires and LED luminaires over the wall was $180.6[cd/m^2]$ and $155.26[cd/m^2]$ respectively. Namely, the maximum luminance of fluorescent luminaires was higher than one of LED luminaires. The average luminance of fluorescent luminaires and LED luminaires was $44.32[cd/m^2]$ and $58.65[cd/m^2]$. Like this, the average luminance of LED luminaires was higher than one of fluorescent luminaires. Considering these results, it's thought that LED luminaires can give a person in the room a more comfortable working environment than fluorescent luminaires.

Analysis of the Change of Intensity Distribution and Luminous Environment by Reflector Shape in Indirect Reflected LED Luminaires (간접 반사형 LED 조명기구의 반사판 형태에 따른 배광형태 및 조명환경 변화 분석)

  • Kim, Yu-Sin;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.1
    • /
    • pp.9-17
    • /
    • 2011
  • Development of high efficiency and eco-friendly LED source has been progressed continuously. Also, by nation's regulations, public institutions have changed existing luminaires to LED luminaires. However, there are several differences between existing luminaires and the intensity distribution of general planar LED luminaires. In case of changing existing luminaires to LED luminaires, by such differences, there are inefficiencies both quality aspect and energy aspect in luminous environment. Therefore, this study aims to conduct a study on the changes of intensity distribution and luminous environment by reflector shapes in indirect reflected LED luminaires with software for optical design of a luminaire (Photopia 2.0) and lighting design of a space (ReluxPro). This study shows the changes of intensity distribution and luminous environment of indirect reflected LED luminaires and indirect fluorescent lamp luminaires by reflector shapes.

The Operation Characteristics of Hybrid Supercapacitor Module for LED Emergency Luminaires (LED 비상 유도등을 위한 하이브리드 슈퍼커패시터 모듈의 동작 특성)

  • Mang, Ju-Cheul;Yoon, Jung-Rag
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.7
    • /
    • pp.473-479
    • /
    • 2015
  • Hybrid supercapacitors with high power density and long cycle life are widely used for emergency power source of LED emergency luminaires. In this paper, we designed and fabricated a hybrid capacitor cell and a module for the LED emergency luminaires. Using hybrid supercapacitor cells (1,000 F, 2.8 V), we designed a module in a 10-year warranty considering aging and ESR. Considering the ESR and efficiency has been designed to module with 1,000 F 5.6 V design results in 2 series and 2 parallel combination. Module was used to confirm that the operation 77.5 minutes at room temperature, discharge LED emergency luminaires with 2 W. As a LED emergency luminaires of emergency power supply that we can support more than 10 years of life was confirmed the applicability of hybrid supercapacitor.

Application and effect analysis of LED luminaires for naval vessels (LED 조명기구의 함정 적용과 효과분석)

  • Cho, Kyu-Lyong;Kil, Gyung-Suk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.9
    • /
    • pp.812-817
    • /
    • 2016
  • This paper dealt with electrical and optical requirements of naval vessel's LED luminaires. And the products have been tested to determine whether the products meet these requirements or not. This study analyzes the cost-effectiveness of the LED luminaires which have been implemented for the application to naval vessel since 2012. The LED requirements were proposed based on comparison among other standards/specifications such as Korean Industrial Standard(KS), Korean Defense Specification(KDS) and US Navy Military Specification(MIL). Application of the proposed requirements were then be verified by analyzing and testing the electrical and optical characteristics of both fluorescent Luminaires and LED luminaires, and the LED luminaires were installed to A1 naval vessels according to the proposed requirements. As results, approximately 40% of power consumption was saved by using LED luminaires compared to using fluorescent luminaires while luminous flux was increased by 10~15%. Moreover, using LED luminaires of the proposed requirements exhibited the effect of reducing approximately 4,900 fluorescent luminaires in 10 naval vessels in the time period between 2012 to 2015, which is equivalent to cost reduction of \0.56M approximately. Such cost reduction is further expected considering the LED luminaires will continue to be applied to naval vessels in the future.

A Study on Energy Savings When replacing Performing Halogen Lights with LED Lights in Seoul Community Hall (서울시 구민회관 공연용 할로겐 조명을 LED 조명으로 교체시 에너지 절감에 관한 연구)

  • Lee, Jang-Weon;Kwon, Hyeok-Hwan
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.5
    • /
    • pp.213-217
    • /
    • 2015
  • Seoul has 25 areas of City Hall, the ward office has been operating theater at least 1 in maximum 4-5 locations to various sized places. The purpose of theater has been used for a variety of purposes to typical performances of Drama and Musicals, School play, Lecture. This points to a Variety of ideas for use, when replacing an exsting halogen luminaires, appropriate LED luminaires, Learn more if there is any advantage in terms of the energy saving part. it will be applied to the value for the energy saving to ward office hall of the actual targets. In case replacement in existing halogen luminaires to LED luminaires, to energy savings of about 80% appear around. Get the advantages of the various functional properties a device chip of the LED itself, Forward will be referred to as easy to replace the halogen luminaires and LED luminaires.

Design Guide of Surface and Watertight LED Luminaires for Naval Vessels (함정용 노출.방수형 LED 조명기구의 설계 방안)

  • Kil, Gyung-Suk;Kim, Il-Kwon;Cho, Hyang-Eun;Kwon, Hyuk-Sang;Cho, Heung-Gi
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.5
    • /
    • pp.654-660
    • /
    • 2011
  • This paper dealt with a design guide of LED luminaires to replace the surface and watertight fluorescent lamp (FL) fixtures for naval vessels. Several standards such as Korean Industrial Standard (KS), Korea Defence Standard (KDS) and US Military Standard (MIL) were compared in terms of safety and performance of lighting fixtures. The electrical and optical characteristics like power consumption, total luminous flux, and illumination distribution of the FL fixtures were experimentally analyzed to acquire design rules for LED luminaires. Based on the results, four types of LED luminaires were fabricated, and we proposed a design guide of LED luminaires for naval vessels which save power consumption of 44~51 [%] and increase total luminous flux of 8~13 [%].

Design of the Lens Structure for COB type LED Safety Luminaires (COB형 LED 보안등을 위한 렌즈 구조 설계)

  • Jang, Sung-Whan;Jung, Byoung-Jo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.8
    • /
    • pp.1-8
    • /
    • 2013
  • The study carried out in this dissertation focuses on the lens structure design and the light distribution for LED safety luminaires using COB type LED module. Lens structures for LED lights has been designed 1) to induce light diffusion by dual process of internal reflection and refraction, 2) to minimize the inherent LED lights' glittering, and 3) to have uniform brightness. The lens designed with the proposed structures function as diffusers for the divergence of the LED lights so that they form a wide angle of view and adjust the light distribution. We designed of lens with stable uniformity factor and average roughness using aspheric optics property. Finally we made the analysis data of the simulated data.

Comparative Analysis on Heat Radiation of LED Luminaires (LED 등기구의 발열량 비교분석)

  • Kim, Dong-Geon;Kim, Il-Kwon;Yu, Seon-Young;Kwon, Wook;Kil, Gyung-Suk
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1530-1535
    • /
    • 2011
  • Heat radiation of LED luminaires has risen a problem when applied indoor. LEDs can save energy with higher efficacy than other light sources. However, their heat radiation may increase power consumption for air-conditioning. Therefore, this paper carried out a comparative analysis on the amount of heat radiation for MR16, E26 bulb, and down-light which will be replaced to LED luminaires. Heat amount of LED-MR16 and LED-downlight was 48% and 87.5% lower than that of conventional lamps, halogen MR16 and E26 CFL, respectively. Consequently, the heat amount and indoor temperature were proportional to the power consumption of luminaire. Therefore, the use of LED luminaire can reduce the amount of heat radiation as well as power consumption.

  • PDF

A Study on the Standby Power Characteristics of Sensor Luminaires (광원별 센서등기구의 대기전력 특성에 관한 연구)

  • Park, Chang-Yong;Seo, Jeong-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.10
    • /
    • pp.9-15
    • /
    • 2014
  • Standby power, so called an electric vampire, is a power which is consumed by appliances and office equipments connected to power sources while the devices are not performing. Sensor luminaires consist of PIR(Pyroelectric Infrared Ray) sensor, illuminance sensor(CdS), and light source. The sensor luminaires are one of the devices that consume a huge amount of standby power; it stands by for an average sum of 23 hours a day and performs only when moving subjects are detected under it, which barely takes up an hour per day. The purpose of this study is to provide basic materials to the selection of standby power items and to enable to explore a way to decrease the standby power by measuring and analyzing the power consumption of sensor luminaires. According to the results, the average standby power of LED sensor luminaires is 1.1W which is significantly higher than other products, and decrease in the standby power consumption of SMPS is important through the measurement.

A Study on the Comparison of the Optical Design of LED Prism Luminaires from Lighting Optical Design Softwares (LED 프리즘 조명기구의 광학설계를 위한 조명광학설계 소프트웨어 비교 연구)

  • Kim, Yu-Sin;You, Min-Jeong;Choi, An-Seop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.15-18
    • /
    • 2009
  • Photopia, LightTools, and ASAP are typical software for optical design of a luminaire. Through using various lighting simulation software some different results can be found under the same conditions. Therefore, the purpose of this paper is to compare simulated photometric data and values illuminance of different types of LED prism luminaires under the same conditions. Then, LED prism luminaires were divided into the linear type and the planar type. Also three kinds of prism angles were divided into $30^{\circ}$, $45^{\circ}$, and $60^{\circ}$. In addition, the reasons for such differences were analyzed.

  • PDF