• Title/Summary/Keyword: LED lamp

Search Result 424, Processing Time 0.026 seconds

Thermal Flow Analysis for Development of LED Fog Lamp for Vehicle (차량 LED 안개등 개발을 위한 열유동 해석)

  • Lee, Suk Young
    • Journal of Energy Engineering
    • /
    • v.28 no.4
    • /
    • pp.35-41
    • /
    • 2019
  • In order to overcome these disadvantages, the halogen light source, which was previously used as a vehicle fog light, has increased power consumption and a short lifetime, and thus, an automobile light source is gradually being replaced with an LED. However, when the vehicle LED fog light is turned on, there is a disadvantage in reducing the life of the fog lamp due to the high heat generated from the LED. The heat generated by the LED inside the fog lamp is mainly emitted by the heatsink, but most of the remaining heat is released to the outside through convection. When cooling efficiency decreases due to convection, thermal energy generates heat to lenses, reflectors, and bezels, which are the main parts of lamps, or generates high temperatures in LED, thereby shortening the life of LED fog lights. In this study, we tried to improve the heat dissipation performance by convection in addition to the heat dissipation method by heat sink, and to determine the installation location of vents that can discharge the internal air or intake the external air of LED fog lamp for vehicle. Thermal fluid analysis was performed to ensure that the optimal data were reflected in the design. The average velocity of air increased in the order of Case3 and Case2 compared to Case1, which is the existing prototype, and the increase rate of Case3 was relatively higher than that of other cases. This is because the vents installed above and below the fog lamps induce the convective phenomena generated according to the temperature difference, and the heat is efficiently discharged with the increase of the air speed.

Effect of tunnel lighting replacement on power usage and illumination improvement: replacing low pressure sodium lamp with LED (터널 조명등 교체에 따른 전력사용량 및 조도 개선 효과: 저압나트륨램프 LED로 교체)

  • Lee, Gyu-Phil;Kim, Jeong-Heum
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.22 no.2
    • /
    • pp.185-196
    • /
    • 2020
  • Low-pressure sodium lamps, high-pressure sodium lamps and fluorescent lamps etc are mainly used tunnel lighting in Rep. of Korea. Power rates for tunnel lighting are known to account for the highest percentage in the tunnel maintenance costs. Therefore, tunnel lights are being replaced by LED that have advantages such as low power consumption and longevity. To analysis effect of replacement low pressure sodium lamp with LED, illumination and monthly power usage for a year are investigated for 8 tunnels. Power usage for tunnel lighting is decreased by 26.1% to 59.6%, and illumination is increased by 34.1% to 293% replacing low pressure sodium lamp with LED.

A Design and Implementation Digital Vessel Bio Emotion Recognition LED Control System (디지털 선박 생체 감성 인식 LED 조명 제어 시스템 설계 및 구현)

  • Song, Byoung-Ho;Oh, Il-Whan;Lee, Seong-Ro
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.48 no.2
    • /
    • pp.102-108
    • /
    • 2011
  • The existing vessels lighting control system has several problems, which are complexity of construction and high cost of establishment and maintenance. In this paper, We designed low cost and high performance lighting control system at digital vessel environment. We proposed a system which recognize the user's emotions after obtaining the biological informations about user's bio information(pulse sensor, blood pressure sensor, blood sugar sensor etc) through wireless sensors controls the LED Lights. This system classified emotions using backpropagation algorithm. We chose 3,000 data sets to train the backpropagation algorithm. As a result, obtained about 88.7% accuracy. And the classified emotions find the most appropriate point in the method of controlling the waves or frequencies to the red, green, blue LED Lamp comparing with the 20-color-emotion models in the HP's 'The meaning of color' and control the brightness or contrast of the LED Lamp. In this method, the system saved about 20% of the electricity consumed.

A Comparison Characteristics on the Structures of the LED Traffic Signal Lamp Controller for the Domestic Use (국내 LED 교통 신호등용 안정기 구조별 특성 비교)

  • Park, Chong-Yeun;No, Kyung-Ho
    • Journal of Industrial Technology
    • /
    • v.25 no.B
    • /
    • pp.183-188
    • /
    • 2005
  • Instead of the incandescent lamps the LED lamps have been used on the traffic signal lamp with the advantages of small loss, no lens and long life. In this paper, we have compared three kinds of the LED controller structures and showed the LED array decision methods. We studied the temperature characteristics on LED and the temperature compensation network. The experimental results showed that the electrical characteristics of three kinds of the LED controller structures were different each other. We concluded that the temperature compensation is the important technique, the best compensation network has the ${\pm}10%$ variation for the luminous intensity.

  • PDF

Development of 1.2kW LED Light with Water-Air Circulation (수공냉 대류방식을 이용한 1.2kW급 LED 조명등 개발)

  • Yoon, Byung-Woo;Song, Jong-Kwan;Park, Jang-Sik;Kwon, Hong-Bae
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.5
    • /
    • pp.615-622
    • /
    • 2015
  • As the development of high efficiency and high flux density LEDs, the trend of illumination lamp industry transfers from conventional-lamps to the LED-lamps. For energy efficiencies, LED lamps are superior to the conventional lamps, but they have heat problems. Especially, the heat problems are severe for the high luminance lamps. They degrade the soldering point of the metal PCB, and shorten the life cycle of LEDs. So, the solution of the heat sinking is very important to develop high luminance LED lamps. This study suggested a new method to solve the heat problems for high luminance LED lamps, and developed a LED lamp which has 1200W power. In this study, a water jacket is installed to the LED lamp, and the cooing water is circulated by a water pump.

Analysis on IEC 62471 for The Introduction of Photobiological Safety of LED Lamp (LED조명의 광생물학적안전성 도입을 위한 IEC 62471 규격 분석)

  • Ko, Jae-Kyu;Cho, Mee-Ryoung;Lee, Min-Jin;Kim, Ju-Hyun
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2012.11a
    • /
    • pp.435-443
    • /
    • 2012
  • First introduced in 1962, LED(light-emitting diodes) emitted low-intensity red light, but modern versions are now available across the ultraviolet, visible, and infrared spectrum, many with very high luminance or brightness. As a result, growing importance of potential safety harzards for human. Now when certificated of CE provide that testing through IEC/EN 62471 for any lamp. Korea standard adopted as it IEC 62471:2006, Photobiological safety of lamps and lamp systems without change, but effectiveness is incomplete. In this paper, we introduce analysis and direction that urgently come into effectiveness of KS C IEC 62471 as a national standard specifications.

  • PDF

Optical Design of Multimedia-Embedded LED Dental Astral Lighting using the Reverse Dual Reflector Method

  • Kwon, Young Hoon;Hwang, Hyo Chang;Jun, Hwa Joon;Kwon, Jin Hyuk
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.4
    • /
    • pp.409-414
    • /
    • 2015
  • Light-emitting diodes (LED) have many advantages for dental astral lighting because of their high color rendering index (CRI), low power consumption, light weight and longer life. A dental astral lamp is specially designed and simulated for securing the extra space for installing a multimedia display that will be helpful for treating young patients. The optical system using the reverse dual reflection method consisted of four illumination modules disposed at the four corners of the dental astral lamp, and each module comprises a high power LED, an elliptical mirror, and a multifacet reflector assembly using eight cylindrical mirrors. It is shown that the required illuminance, illumination pattern, and the illumination uniformity are well satisfied.

The Study based on Accelerated Life Testing of 4W LED Lamp using internal converter (4W 컨버터 내장형 Lamp의 가속시험평가)

  • Park, Chang-Kyu;Cho, Sang-Muk;Kim, Jin-Sheon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.77-79
    • /
    • 2009
  • The paper is to evaluate for reliability of 4W LED Lamp using internal converter by ALTs(Accelerated Life Tests). The recently, some of KS were established by law of LED Modules for Lighting(KS C 7651, 7652, 7653, 7655, 7656, 7657, 7658 and 7659), but reliability assessment methods of LED Lamps had not been established. Therefore, the paper aided companies to perform accelerated life testing(temperature 60 $^{\circ}C$, humidity 90 %) for themselves.

  • PDF

High Flux LED Garden Lamp Using PV Generation System (태양광 발전을 이용한 하이 플럭스 LED 정원등)

  • Choi, Guang-Soo;Jung, Doo-Yong;Kim, Jea-Hyung;Won, Chung-Yuen;Kim, Young-Real
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.445-448
    • /
    • 2008
  • There are increased interests in using new regeneration energy due to the effect of the latest rising oil price. On this account, various practical applications using small stand-alone PV generation system are being made. In this paper, with intent to change mercury lamp using for existing garden lamp with high flux LED, we have considered load characteristic using high flux LED modules applied to PV system. It is simulated with PSIM and made experiment set with a 75[W] solar cell module, DC-DC converter, controller and battery.

  • PDF

Rear Combination LED Lamp operation is applied to control Study on Improvement (Rear Combination LED Lamp 동작에 적용되는 제어특성 개선에 관한 연구)

  • Hwang, Seong-Sik;Song, Gwang-Chul;Song, Gwang-Suk;Park, Sung-Jun
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.35-36
    • /
    • 2014
  • 본 논문은 Rear Combination LED Lamp 동작 시 전류와 광출력의 변동폭를 최소화하는 LED 조명광원의 특성을 고려하여 정전류 회로의 구현이 유리한 DC/DC 컨버터의 EMC 고효율 필터를 제안하여 외부의 전자계로부터 장애를 유발하지 않고, 일정 수준의 전자파 환경에서도 오동작 없이 원할하게 작동될 수 있도록 관련 기기 상호간의 전파 환경을 개선하는 고효율 Filter를 제안 하고자 한다. 본 논문에서 제안한 Filter는 EMI 측정을 통해 타당성과 우수성을 검증하였다.

  • PDF