• 제목/요약/키워드: LCO

검색결과 108건 처리시간 0.027초

A 0.55" PDLC-LCoS Micro-display for Mobile Projectors

  • Do, Yun-Seon;Yang, Kee-Jeong;Sung, Shi-Joon;Kim, Jung-Ho;Lee, Gwang-Jun;Lee, Yong-Hwan;Chung, Hoon-Ju;Roh, Chang-Gu;Choi, Byeong-Dae
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.1527-1530
    • /
    • 2009
  • A LCoS micro-display using polymer dispersed liquid crystals (PDLCs) for light switching layer was fabricated. The Si backplane of SVGA ($800{\times}600$) with a pixel size of $14{\times}14mm^2$ was prepared by a $0.35{\mu}m$ 18V CMOS process. PDLCs were filled in the gap between backplane and ITO glass by conventional vacuum filling method. The prepared panels were driven by a field sequential color (FSC) scheme at the frequency of 180Hz and were successful in modulating LED lights to show projection images. The preparation and performance of PDLC-LCoS are presented.

  • PDF

통상성 간질성 폐섬유증의 임상경과 (Clinical Course of Usual Interstitial Pneumonia)

  • 박주헌;;염호기;심태선;임채만;이상도;고윤석;김우성;김원동;김동순
    • Tuberculosis and Respiratory Diseases
    • /
    • 제49권5호
    • /
    • pp.601-613
    • /
    • 2000
  • 연구배경 : 통상성 간질성 폐섬유증(usual interstitial pneumonia : UIP)은 특발성 간질성 폐렴(Idiopathic interstitial pneumonia : I.I.P)의 한 형태로서 생존기간 중앙값이 약 3-5 년 정도로 보고되는 치명적인 질환으로 알려져 있으나, 최근 분류된 BOOP이나 NSIP등을 제외한 순수한 UIP환자들만을 대상으로 임상경과나 예후에 대한 연구는 외국에서도 극소수아고, 국내에서는 보고된 바가 없다. 이에 연구자들은 수술적 폐생검 검사로 확진된 UIP 환자들의 임상경과와 예후의 예측 지표를 찾고자 본 연구를 시행하였다. 방법 : 1989년 3월부터 1999년 8월까지 서울중앙병원에서 개흉 또는 흉강경을 통한 폐생검검사로 UIP로 진단된 72명(연령 $58.2{\pm}11.6$세, 남 : 여=45:27, 관찰기간 중앙값 : 18.1개월 (0.7-103.6개월))을 대상으로 하였다. 진단시의 임상증상과 흉부고해상도단층촬영, 폐기능검사, 동맥혈 가스검사 등을 증상점수(C) (1-20점), 방사선학점수(R)(봉와양 소견 : 0-5점, 젖빛유리야 소견 : 0-5점) 및 생리적검사점수(P) (FVC 1-12점, $FEV_1$ 0-3점, TLC 1-10점, $D_{LCO)$ 0-5점, $AaDO_2$ 0-10점)로 수치화하여 CRP 접수를 계산하였다. 임상경과와 진단시의 CRP점수, 기관지 폐포세척액검사 등을 비교 분석하여 예후의 예측지표를 검색하였다. 결과 : 1) 대상 UIP환자들의 1년 누적생존률은 78.3%, 3년 누적생존률은 58.1% 였고, 생존기간 중앙값은 42.5개월이었다. 2) 단기(1년)예후 : 단기 사망군(14명)은 생존군(46명)에 비하여 전체CRP점수($28.6{\pm}8.3$ vs. $16.6{\pm}9.7$)가 높았으며, 이는 주로 증상점수($8.4{\pm}2.1$ vs. $5.7{\pm}3.9$)와 FVC, $D_{LCO)$, $AaDO_2$를 포함하는 생리적검사점수 $v{\pm}7.5$ vs. $8.1{\pm}7.3$)의 차이에 기인하였다. 또한 호전 혹은 안정군(61.7%)과 악화군 및 사망군(38.3%) 사이에는 연령과 흡연률, 진단당시의 CRP점수(증상점수, FVC, $AaDO_2$, $D_{LCO)$)가 유의한 차이가 있었다. 그러나 방사선학점수, TLC 및 기관지폐포세척액소견 등은 유의한 차이가 없었다. 2) 장기(3년) 예후 : 장기생존군(14명)은 사망군(22명)에 비하여 역시 진단시 총CRP점수($12.2{\pm}6.7$ vs. $28.7{\pm}7.9$)와 증상점수, FVC, $D_{LCO)$, $AaDO_2$)가 차이가 있었다. 3) 생존기간분석에서도 총 CRP 점수와 증상점수, $AaDO_2$ FVC, $D_{LCO)$가생존기간과 유의한 상관관계를 보였다. 4) Cox 회기분석을 이용한 다변수 분석에서는 $D_{LCO)$ (${\geq}$60% : Hazard ratio : 4.56, 95% CI : 2.30-16.04)만이 UIP환자 사망의 독립적인 예측인자로 나타났다. 결론 : 이상의 결과는 UIP 진단시의 $D_{LCO)$는 UIP환자의 예후를 예측할 수 있는 임상적 지표임을 시사하였다.

  • PDF

Effect of sweep angle on bifurcation analysis of a wing containing cubic nonlinearity

  • Irani, Saied;Amoozgar, Mohammadreza;Sarrafzadeh, Hamid
    • Advances in aircraft and spacecraft science
    • /
    • 제3권4호
    • /
    • pp.447-470
    • /
    • 2016
  • Limit cycle oscillations (LCO) as well as nonlinear aeroelastic analysis of a swept aircraft wing with cubic restoring moments in the pitch degree of freedom is investigated. The unsteady aerodynamic loading applied on the wing is modeled by using the strip theory. The harmonic balance method is used to calculate the LCO frequency and amplitude for the swept wing. Finally the super and subcritical Hopf bifurcation diagrams are plotted. It is concluded that the type of bifurcation and turning point location is sensitive to the system parameters such as wing geometry and sweep angle.

Development of Inorganic Alignment Technique with One Drop Filling Processon LCoS Panel

  • Wang, Jiun-Ming;Lo, Yu-Cheng;Liu, Sheng-Fa;Huang, Li-Chen;Chen, Kun-Hong;Liu, Kuang-Hua;Li, Huai-An;Sun, Oliver;Yang, Shih-Tsung
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.1235-1238
    • /
    • 2006
  • One-Drop-Filling (ODF) process is an advanced vacuum filling process in LCoS manufacture line. The merits not only increase the throughput of liquid crystal filling process but also reduce the number of equipments. Studying application of ODF process in LCoS panel manufacturing is the purpose of is this article. The accuracy of liquid crystal drop size, the stability of seal dispensing and the nozzle size etc. In the tiny panel manufacture are more important than those factors in normal panel manufacture.

  • PDF

Growth of the substrate crystals for $La_{2-x}Sr_{x}CuO_{4}$ thick films

  • Watauchi, Satoshi;Tanabe, Hideyoshi;Tanaka, Isao;Kojima, Hironao
    • 한국결정성장학회지
    • /
    • 제9권4호
    • /
    • pp.384-386
    • /
    • 1999
  • The distribution coefficients of Ni and Zn to the Cu site in $La_{2-x}Sr_{x}CuO_{4}$(LCO) were investigated to determine the suitable solvent composition ofr crystal growth of $La_{2}{Cu}_{1-x}{M}_{x}{O}_{4}$(M=NI, Zn)(LCMO), and were found to be 4.2 for NI and 0.66 for Zn, respectively. Single crystals of LCO, and LCMO of high homogeneity were grown by traveling solvent floating zone technique using suitable solvents. NO diamagnetic signals were observed for all substituted crystals. This fact suggests that crystals of LCO partially substituted by Ni or Zn are useful as substrate crystals.

  • PDF

The Effect of the Plasma Treatment in ITO Film to reduce impurities in LCOS Imager

  • Kim, Joo-Hyung;Kim, Sang-Ha;Cho, Chul-Sik
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2002년도 International Meeting on Information Display
    • /
    • pp.541-544
    • /
    • 2002
  • The reflective liquid crystal(LC) imager in one panel Liquid Crystal on Silicon(LCoS) System must have the properties such as fast response time, high contrast ratio(C/R) and voltage holding ratio(VHR) which are more related to the lifetime of imager than the others. As the high-output light including a short wavelength from UHP lamp is exposed to LCoS imager, the indium metal impurities, which decrease the C/R and VHR, are diffused from ITO thin film on glass. To ensure the high reliable LCoS imager for HD projection TV, we have studied the effects of the plasma treatment on ITO film to reduce impurities in imager.

  • PDF

홀로그램 단말을 위한 LC기반 대면적 SLM 기술

  • 황치선;김용해;김기현;변춘원;오힘찬;피재은;최지훈;김진웅
    • 정보와 통신
    • /
    • 제32권3호
    • /
    • pp.44-51
    • /
    • 2015
  • 디지털 홀로그램 디스플레이는 SLM을 이용하여 홀로그램 영상을 구현하므로, 홀로그램 영상의 품질은 SLM에 의하여 제한되게 된다. 따라서, 대면적 광시야각의 홀로그램 단말을 개발하기 위해서는 대면적 초고해상도의 SLM이 필수적이다. 그런데, 지금까지의 홀로그램은 주로 상용 SLM인 LCoS나 DMD를 기반으로 구현되었다. 이러한 상용 SLM의 경우에는 패널의 크기가 작고 픽셀 피치가 커서, 대면적으로 홀로그램 영상을 구현하는 것과 광시야각을 구현하는 데 있어서는 아직까지 한계를 보이고 있으며, 이에 따라 대면적 초고해상도의 SLM 개발이 요구되고 있다. 본고에서는 지금까지 홀로그램 디스플레이를 구현하는데 이용되어온 주요한 SLM인 LCoS, DMD, LCD등에 대하여 살펴보고, 이러한 SLM이 가진 한계를 극복할수 있는 기술로 대면적 디스플레이 기술을 기반으로 LCoS 기술을 구현하고자하는 SLMoG 기술에 대하여 소개고자 한다.

Semi-interpenetrating Solid Polymer Electrolyte for LiCoO2-based Lithium Polymer Batteries Operated at Room Temperature

  • Nguyen, Tien Manh;Suk, Jungdon;Kang, Yongku
    • Journal of Electrochemical Science and Technology
    • /
    • 제10권2호
    • /
    • pp.250-255
    • /
    • 2019
  • Poly(ethylene oxide) (PEO)-based solid polymer electrolytes (SPEs) show promise for improving the lithium ion battery safety. However, due to oxidation of the PEO group and corrosion of the Al current collector, PEO-based SPEs have not previously been effective for use in $LiCoO_2$ (LCO) cathode materials at room temperature. In this paper, a semi-interpenetrating polymer network (semi-IPN) PEO-based SPE was applied to examine the performance of a LCO/SPE/Li metal cell at different voltage ranges. The results indicate that the SPE can be applied to LCO-based lithium polymer batteries with high electrochemical performance. By using a carbon-coated aluminum current collector, the Al corrosion was mostly suppressed during cycling, resulting in improvement of the cell cycle stability.

기류제한 환자의 일산화탄소확산능 해석에서 폐용적 보정의 의의 (Importance of Carbon Monoxide Transfer Coefficient (KCO) Interpretation in Patients with Airflow Limitation)

  • 서용우;최원일;이정은;박훈표;고성민;원경숙;금동윤;이미영;전영준
    • Tuberculosis and Respiratory Diseases
    • /
    • 제59권4호
    • /
    • pp.374-379
    • /
    • 2005
  • 배 경 : 폐확산능 ($D_LCO$)과 폐용적을 보정한 확산계수($D_LCO/VA$; KCO)는 폐포용적이 비 정상적인 경우 차이가 생긴다. 그러나, 기류제한으로 비 정상적인 폐포용적을 가지는 환자에서 이러한 차이의 의미는 연구되지 않았다. 본 연구는 기류제한이 있는 환자에서 기류제한의 호전에 따른 폐확산능과 확산계수의 변화를 연구하고자 한다. 방 법 : 기류제한이 있는 환자에서 기저 폐기능과 더불어 폐확산능을 측정하고, 일회호흡 $CH_4$ 희석법으로 폐포용적을 측정하였다. 기저치에 따라서 환자는 다음의 두 군으로 나누었다. 확산계수(예측치에 대한 백분율)와 확산능(예측치에 대한 백분율)의 비가 115%를 넘는 경우를 고차이군으로 하였고, 115% 미만인 경우를 저차이군으로 하였다. 기류제한을 치료 한 후 폐기능검사와 폐확산능을 반복해서 측정하였다. 결 과 : 고차이군과 저차이군의 기저 폐기능은 유의한 차이가 관찰되지 않았다. 두 군 모두 확산계수의 예측치에 대한 백분율은 평균 113%와 100%로 정상범위였다. 치료 후 추적 폐기능에서 $FEV_1$과 FVC는 저차이군에 비해 고차이군에서 증가하였다. 고차이군에서 치료 후 측정한 폐기능은 기저치에 비해 폐확산능과 폐포용적은 증가하였으나 저차이군에서는 유의한 차이는 관찰되지 않았다. 전폐용적과 잔기량은 치료 전후에 양군 모두에서 유의한 차이가 관찰되지 않았다. 결 론 : 기류제한이 있는 환자에서 확산계수는 정상 범위에 있지만 확산능이 감소한 경우 확산능이 감소하지 않은 환자에 비해 가역적인 기류폐색이 클 것으로 예측할 수 있다.

슬러리상 수첨분해 반응에서 아로마틱 유분 첨가에 따른 코크 저감 및 아스팔텐 전환 특성 (Effect of Aromatic Additives on the Coke Reduction and the Asphaltene Conversion in a Slurry-phase Hydrocracking)

  • 임석현;고강석;노남선;이재구
    • Korean Chemical Engineering Research
    • /
    • 제57권2호
    • /
    • pp.244-252
    • /
    • 2019
  • 본 연구에서는 감압잔사유를 원료로 몰리브덴 계열 분산촉매와 수소를 첨가한 슬러리상 수첨분해 반응(반응온도 $425^{\circ}C$, 초기 $80^{\circ}C$ 수소압력 80 bar, 반응시간 4시간, 촉매농도 500 ppm)에 아로마틱 성분을 포함하며 각기 다른 쌍극자 모멘트를 가지는 Toluene, FCC Light Cycle Oil (LCO), Resin을 반응 초기 및 중간에 첨가하여 이때의 코크 저감효과와 아스팔텐 반응특성 변화를 살펴보았다. 실험 결과 아로마틱 유분을 첨가한 경우 코크 저감효과는 모두 유사했던 반면, 상대적으로 쌍극자 모멘트가 큰 LCO와 Resin을 첨가한 경우 아스팔텐이 가스와 말텐 성분으로 더 전환되었음을 확인하였다. 또한 반응 중간에 아로마틱 유분을 첨가한 결과 코크 저감능력에서 차이를 보이지 않았으나, LCO를 반응 2시간 지점에 첨가한 경우 오히려 코크 수율이 증가하였고 오일상 내 아스팔텐의 aromaticity 가 증가하여 상대적으로 분산되기 어려운 구조로 존재함을 알 수 있었다.