• Title/Summary/Keyword: LCD modules

Search Result 53, Processing Time 0.025 seconds

Design and Implementation of Hand-Held Inspection Device for High Performance Mobile TFT LCD/OLED Module (고성능 모바일 TFT LCD/OLED 모듈을 위한 헨드헬드 검사장비 설계 및 구현)

  • Moon, Seung-Jin;Kim, Hong-Kyu
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.6B
    • /
    • pp.630-640
    • /
    • 2009
  • The thesis suggests hand-held equipment to overhaul for mobile TFT LCD/OLED module of high-performance. The established module equipment to overhaul could distinguish outputting video data to module for distinguishing flicker, but it is impossible with low system. In this thesis, supporting system could check the various supplement functions from bringing equipment to overhaul without changing design of FPGA or H/W the module various size for equipment to overhaul for module of high-performance coincidently. The system includes hand-held equipment to overhaul, test software embedded and software a base personal computer and have designed to output, save, and certify all contents of module test of hand-held equipment to overhaul to interface universal serial bus. Setting up 9 items that represent for efficient verification of the proposed system have been possible confirmation with TFT LCD/OLED module of high-performance, establishment scan time, creation gamma, changing register, supporting interface, and multi inch modules.

Improved characterization method for mobile phone camera and LCD display (모바일 폰 카메라와 LCD의 향상된 특성화 방법)

  • Jang, In-Su;Son, Chang-Hwan;Lee, Cheol-Hee;Song, Kun-Woen;Ha, Yeong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.45 no.2
    • /
    • pp.65-73
    • /
    • 2008
  • The characterization process for the accurate color reproduction in mobile phone with camera and LCD is popular. The camera and LCD characterization, gamut mapping process is necessary to map the camera's input color stimulus, CIEXYZ value, into the LCD's output color stimulus. Each characterization is the process estimating the relation between input and output signals. In case of LCD, because of output device, the output color stimulus for the arbitrary input signal can be measured by spectro-radiometer However, in the camera, as the input device, the characterization is an inaccurate and needs the manual works in the process obtaining the output signal because the input signal can not be generated. Moreover, after gamut mapping process, the noise is increased because the optimized gamma tone curve of camera for the noise is distorted by the characterization. Thus, this paper proposed the system of obtaining the output signal of camera and the method of gamma correction for the noise. The camera's output signal is obtained by RGB values of patches from captured the color chart image. However, besides the illumination, the error for the location of the chart in the viewfinder is generated when many camera modules are captured the chart. The method of correcting the position to correct the error from manual works. The position of camera is estimated by captured image. This process and moving of camera is accomplished repeatedly, and the optimized position can be obtained. Moreover, the lightness curve of camera output is corrected partly to reduce the noise from the characterization process.

New dual cascade loop controller with color LCD bar graphs, equipped with a memory card

  • Kanda, Masae;Uyeno, Mitsugu;Matsuo, Akira;Souda, Yasushi;Terauchi, Yukio
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10b
    • /
    • pp.1327-1331
    • /
    • 1990
  • A new dual loop controller using color LCD bar graphs with LED back lights has been developed. An optional memory card is used to load or save the controller configuration, which may be a preprogrammed standard package or a user-programmed configuration, in addition to the built-in functions ready for user selection. The bar-graph display is selectable for single-loop or dual-loop use. A high grade of self-tuning functions using a modeling technique is built-in as standard. The controller can accommodate optional plug-in modules for thermocouples, communication, etc. All the options are fully field upgradable.

  • PDF

Field Enhanced Rapid Thermal Process for Low Temperature Poly-Si TFTs Fabrications

  • Kim, Hyoung-June;Shin, Dong-Hoon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.665-667
    • /
    • 2005
  • VIATRON TECHNOLOGIES has developed FE-RTP system that enables LTPS LCD and AMOLED manufacturers to produce poly-Si films at low cost, high throughput, and high yield. The system employs sequential heat treatment methods using temperature control and rapid thermal processor modules. The temperature control modules provide exceptionally uniform heating and cooling of the glass substrates to within ${\pm}2^a\;C$. The rapid thermal process that combines heating with field induction accelerates the treatment rates. The new FE-RTP system can process $730{\times}920mm$ glass substrates as thin as 0.4 mm. The uniform nature of poly-Si films produced by FE-RTP resulted in AMOLED panels with no laser-Muras. Furthermore, FE-RTP system also showed superior performances in other heat treatment processes involved in poly-Si TFT fabrications, such as dopant activation, gate oxide densification, hydrogenation, and pre-compaction.

  • PDF

Development of a Patient Monitoring System Overall Architecture and Specifications (환자모니터링시스템의 개발 : 전체구조 및 기본사양)

  • 우응제;박승훈
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.1
    • /
    • pp.17-24
    • /
    • 1997
  • We have developed a patient monitoring system including module-based bedside monitors, interbed network, central stations, clinical workstations, and DB servers. A bedside monitor with a color LCD can accommodate up to 3 module cases and 21 different modules. Six different physiological parameters of ECG, respiration, invasive blood pressure, noninvasive blood pressure, body temperature, and arterial pulse oximetry with plethysmoyaph are provided as parameter modules. In a single bedside monitor, modules and a module controller communicate with IMbps data rate through an intrabed network based on RS-485 and HDU protocol. At the same time, it communicates with other bedside monitors and central stations through interbed network based on 1 OMbps Ethernet and TCP/IP protocol. Central stations using 20" color CRT monitors can be connected with many bedside monitors and they display 18 channels of waveforms simultaneously. Clinical workstations are used mainly for the review of patient datE In order to accommodate more advanced data management capabilities such as 24-hour full disclosure, we have developed a relational database server dedicated to the patient monitoring system. Software for bedside monitor, central station, and clinical workstation fully utilizes graphical user interface techniques and all functions are controlled by a rotate/push button on the bedside monitor arid a mouse on the central station and clinical workstation. The entire system satisfies the requirements of AAMI and ANSI standards in terms of electrical safety and performances.nces.

  • PDF

A study on a precision temperature control unit using thermoelectirc module (열전소자를 이용한 정밀 항온 유지 장치에 관한 실험 및 시뮬레이션 연구)

  • Park, Kyung-Seo;Song, Young-Joog;Im, Hong-Jae;Jang, Si-Yeol;Lee, Kee-Sung;Jeong, Jay;Shin, Dong-Hoon
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.1937-1941
    • /
    • 2007
  • During a process of a nanoimprint for manufacturing LCD, a small temperature variation on the LCD glass can cause thermal stress and generate unexpected displacement. To avoid this trouble, a precision temperature control unit using thermoelectric modules is appropriate for nanoimprint processes. The unit consists of an air control system, a cooling water control system, and a power control system. The air control system includes a thermoelectric module, thermocouples measuring temperatures of air and a duct-stale fin, and two air fans. The heat generated by the thermoelectric module is absorbed by the cooling water control system. The power control system catches the temperature of the thermoelectric module, and a PID controller with SCR controls the input power of the thermoelectric module. Temperature control performance is evaluated by experiment and simulation. The temperature control unit is able to control the exit temperature about ${\pm}2^{\circ}C$ from the incoming fluid temperature, and the error range is ${\pm}0.1^{\circ}C$. However, the control time is approximately 30minute, which needs further study of active control

  • PDF

Design of Interface Module for Driving of Image Processing Using FPGA (FPGA를 이용한 영상처리 구동을 위한 정합모듈 설계)

  • Jung, Sung-Hyuck;Kim, Jung-Tae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.9
    • /
    • pp.2071-2077
    • /
    • 2010
  • Interface modules design between image sensor and external components are designed by FPGA (Field Programmable Gate Array) in this paper. Generally speaking, to satisfy synchronization for the poor quality data in image, SRAM is needed. To receive synchronization signal and image signal data with pixel dimension, the proposed interface logic technique is implemented. From the proposed technique, we can obtain more clear screen by implementing with pixel dimension. Operating frequency of image sensor and that of TFT-LCD are 50MHz and 6.5MHz, respectively. Most of control logic functions are embedded in FPGA. The designed logic gate counter has 33,216 and is designed by Quartus II.

Development of Tele-image Processing Algorithm for Automatic Harvesting of House Melon (하우스멜론 수확자동화를 위한 원격영상 처리알고리즘 개발)

  • Kim, S.C.;Im, D.H.;Chung, S.C.;Hwang, H.
    • Journal of Biosystems Engineering
    • /
    • v.33 no.3
    • /
    • pp.196-203
    • /
    • 2008
  • Hybrid robust image processing algorithm to extract visual features of melon during the cultivation was developed based on a wireless tele-operative interface. Features of a melon such as size and shape including position were crucial to successful task automation and future development of cultivation data base. An algorithm was developed based on the concept of hybrid decision-making which shares a task between the computer and the operator utilizing man-computer interactive interface. A hybrid decision-making system was composed of three modules such as wireless image transmission, task specification and identification, and man-computer interface modules. Computing burden and the instability of the image processing results caused by the variation of illumination and the complexity of the environment caused by the irregular stem and shapes of leaves and shades were overcome using the proposed algorithm. With utilizing operator's teaching via LCD touch screen of the display monitor, the complexity and instability of the melon identification process has been avoided. Hough transform was modified for the image obtained from the locally specified window to extract the geometric shape and position of the melon. It took less than 200 milliseconds processing time.

Development of a Prototype of a Module-Based Patient Monitor (모듈형 환자 모니터 시제품의 개발)

  • Woo, Eung-Je;Park, Seung-Hun;Kim, Kyung-Soo;Choi, Keun-Ho;Kim, Seung-Tae;Moon, Chang-Wook;Jun, Byung-Moon;Lee, Hee-Cheol;Kim, Hyung-Jin;Seo, Jae-Joon;Park, Jong-Chan
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.353-357
    • /
    • 1997
  • We have developed a prototype of a module-based patient monitor. In this paper, we describe the design methodology and specifications of the developed module-based patient monitors. The monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases, each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and $SpO_2$ with plethysmograph.

  • PDF

A Study on Improvement of ERP System According to Account Module Analysis in Small and Middle Enterprise (회계업무 분석에 따른 중소기업 ERP 시스템의 개선 방안 연구 - LCD 산업 ERP 회계 모듈을 중심으로-)

  • Nam, Seung-Don;Yang, Kwang-Mo;La, Seung-Houn;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.4
    • /
    • pp.269-277
    • /
    • 2009
  • we can easily find numerous cases, where the outcomes are not up to their expectations, despite the enormous efforts and investments poured on developing ERP systems. Consequently, we are in need of a new methodology for efficient implementation and Maintenance of an ERP system. Therefore, we have investigated and analyzed various problems that may occur in adopting ERP systems, such as high implementation costs, shortage of professional manpower, and lack of active participation from insiders. In this thesis, we developed a new ERP system, focusing on accounting management modules and benchmarked our proposed model to one of the real companies.