• Title/Summary/Keyword: LC3

Search Result 2,250, Processing Time 0.035 seconds

Insecticidal Activity and Effect on Biological Characteristic of 16 Insecticides Against Phthorimaea Operculella (Lepidoptera: Gelechiidae) (감자뿔나방에 대한 16종 살충제의 살충활성과 생물적 특성에 미치는 영향)

  • An, Jeong-Jin;Park, Jun-Won;Kim, Ju-Il;Kim, Hyun Kyung;Koo, Hyun-Na;Kim, Gil-Hah
    • The Korean Journal of Pesticide Science
    • /
    • v.17 no.4
    • /
    • pp.363-370
    • /
    • 2013
  • Susceptibility of each developmental stage of Phthorimaea operculella (Lepidoptera: Gelechiidae) were investigated using 16 insecticides which are available in the market in Korea. For the eggs and pupae, only spinosad showed a 71.1% inhibition rate for egg hatchability and a 66.7% inhibition rate for emergence. For the 3rd instar larvae, the feeding toxicities were over 90% for fenitrothion ($LC_{50}$ 336.6 ppm), esfenvalerate ($LC_{50}$ 8.6 ppm), ethofenprox ($LC_{50}$ 35.7 ppm), and emamectin benzoate ($LC_{50}$ 0.05 ppm). Furthermore, the contact toxicities were over 90% for esfenvalerate ($LC_{50}$ 0.87 ppm), ethofenprox ($LC_{50}$ 16.5 ppm), emamectin benzoate ($LC_{50}$ 0.53 ppm), and spinosad ($LC_{50}$ 2.48 ppm) at the recommended concentrations. Deltamethrin and spinosad yielded 100% mortality for adult P. operculella 48 h after treatment. The adult female fecundity was inhibited by deltamethrin, esfenvalerate, emamectin benzoate, spinosad and dinotefuran, which were significantly different from the control. The adult longevities (7.3-8.3 days) were reduced by approximately 1-2 days compared with the control (9.3 day). The emamectin benzoate maintained 100% insecticidal activity 14 days after treatment and ethofenprox maintained over 90% activity 7 days after treatment.

Determination of Bioconcentration Factor on Phosphamidon and Profenofos by Flow-through Fish Test (Flow-through fish test를 이용한 Phosphamidon과 Profenofos의 생물농축계수의 측정)

  • Min, Kyung-Jin;Cha, Chun-Geun;Seo, Seol
    • Journal of Food Hygiene and Safety
    • /
    • v.15 no.2
    • /
    • pp.137-143
    • /
    • 2000
  • The present study was performed to investigate the bioconcentration of phosphamidon and profenofos. The BCFs(bioconcentration factors), depuration rate constants and LC$_{50}$ for two pesticides in zebrafish(Brachydanio rerio) were measured by the flow-through system(OECD guideline 305). The results obtained are summarized as follows: The 24-hrs LC$_{50}$, 48-hrs LC$_{50}$, 72-hrs LC.n and 96-hrs LC$_{50}$ were more than 100 mg/l for phosphamidon. The concentration of phosphamidon in zebrafish reached an equilibrium in 12 hrs at low and high concentrations(0.2 mg/l and 1 mg/1). The average BCF values of phosphamidon were less than 1 at low(0.96, n=7) and high concentrations (0.89, n=7) after 12~168 hrs. Depuration rate constants of phosphamidon were 0.18 hr-1 and 0.21 hr-1, half-life of phosphamidon were 3.85 and 3.30 at low and high concentrations(0.2 mg/l and 1 mg/l), respectively, The concentrations of phosphamidon in zebrafish at low and high concentrations were rapidly decreased after 8(0.04 $\mu\textrm{g}$/g) and 12 hrs(0.07 $\mu\textrm{g}$/g). The 24-hrs LC$_{50}$, 48-hrs LC$_{50}$, 72-hrs LC$_{50}$ and 96-hrs LC$_{50}$ were 2.9, 2.6, 2.2 and 2.0 mg/1 for profenofos. The concentration of profenofos in zebrafish reached an equilibrium in 12 hrs at five-hundredth and one-hundredth concentration of 96-hrs LC$_{50}$(0.004 mgA and 0.02 mg/1). The average BCF values of profenofos were 141.9(n=7) and 111.3(n=7) at five-hundredth and one-hundredth concentration of 96-hrs LC$_{50}$(0.004 mg/l and 0.02 mg/1) after 12~168 hrs. Depuration rate constants of profenofos were 0.09 hr$^{-1}$ and 0.10 hr$^{-1}$, half-life of profenofos were 7.70 and 6.93 at five-hundredth and one-hundredth concentration of 96-hrs LC50(0.004 mg/l and 0.02 mg/1), respectively. The concentrations of profenofos in zebrafish at five-hundredth and one-hundredth concentration of 96-hrs LC$_{50}$ decreased agter 8(0.18 $\mu\textrm{g}$/g) and 12 hrs (0.19 $\mu\textrm{g}$/g). The LC$_{50}$ value in zebrafish showed that acute toxicity of profenofos was higher than that of phosphamidon. The BCF values of profenofos were 100 times higher than those of phosphamidon, and depuration rate of phosphamidon was two times faster than that of profenofos.

  • PDF

A Study on Liquid Crystal Alignment Effect on a Photopolymer Layer Based N-(phenyl)maleim ids Containing Three Kind of the Substituent (3가지 종류의 치환기를 함유한 N-(phenyl)maleimide계 광폴리머 표면을 이용한 액정 배향 효과에 관한 연구)

  • 황정연;이윤건;서대식;김준영;김태호
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.3
    • /
    • pp.264-268
    • /
    • 2002
  • Three types of polymer, a photoalignment material based N- (phenol)maleimide were synthesized and the liquid crystal (LC) aligning capabilities on the photopolymer layer were studied. A good LC alignment with UV exposure on the PMI5CA(N-(phenol)maleimide with 5-carbon chain cinnamoyl group) can be obtained. However, the LC alignment defects were observed on the PM13CA (N-(phenol)maleimide with 3-carbon chain cinnamoyl group) and PMIF (N-(phenyl)maleimide including fluoro cinnamoyl group). Also, the good LC alignment with UV exposure on the PM15CA surface was observed at until $150^{\circ}C$ of annealing temperature. The LC aligning ability on the photopolymer layer based N-(phenol)maleimide depends on the side chain length of photopolymer.

Study on Short-term Toxicological Evaluation of Treated Landfill Leachate Using Early Stage of River Puffer Fish, Takifugu obscurus (황복 Takifugu obscurus 자치어를 이용한 침출수 단기독성 연구)

  • Park, Hoon;Han, Kyung-Nam;Kim, Hyung-Sun
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.4 no.4
    • /
    • pp.298-304
    • /
    • 1999
  • Toxic effect of landfill leachate on the larvae and juvenile stage of the river puffer fish, Takifugu obscurus, were investigated in order to assess severity of environmental impact of leachate effluent on the general population of estuarine fishes. A short-term toxic experiment was designed to test both laboratory hatched larvae and juveniles (5, 10 and 15 mm in length) and in-situ juveniles (30 and 45 mm in length) using the leachate concentrations between 0 and 16%. Lethal concentrations of 50% mortality ($LC_{50}$) were observed using Spearman-karber Method. 24hr-$LC_{50}$ appeared at the leachate concentrations ranging from 3.03 to 8.57%, 48hr-$LC_{50}$ at 2.73 to 6.21 %, 72hr-$LC_{50}$o at 2.45 to 5.53%, and 96hr-$LC_{50}$ at 2.38 to 4.93%, respectively. Leachate concentrations between 0.69 and 1.51% induced 96hr-$LC_1$. Respiratory frequency was significantly affected even at low leachate concentrations between 0.5 and 1.0% (P < 0.05). These results suggest that the leachate effluents may cause a harmful impact on the physiology of river puffer fish, especially for younger cohorts.

  • PDF

Leakage Current Waveforms of Outdoor Polymeric Insulators and Possibility of Application for Diagnostics of Insulator Conditions

  • Suwarno Suwarno
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.1
    • /
    • pp.114-119
    • /
    • 2006
  • This paper reports the investigation results on the leakage currents (LC) on polymeric outdoor insulators. The samples used were EPDM (ethylene prophylene diene monomer) insulators used at 20 kV distribution lines. AC voltage was applied and the LC waveforms were measured under various environmental conditions (humidity and pollution). Digital data of the LC was transferred from a digital storage oscilloscope to a computer for further analysis. The LC waveform parameters such as magnitude and harmonic content (as indicated by the total harmonic distortion (THD)) were analyzed. The experimental results showed that 3rd, 5th and 7th harmonics and higher odd harmonics were observed for symmetrical-distorted LC waveforms while for unsymmetrical-distorted LC waveforms, odd and even harmonics were observed. The LC analysis indicated that there are 5 stages of insulator conditions from normal condition up to flashover correlated with different kind of LC waveforms. The results also showed that in general the magnitude of LC was good enough to show the condition of the insulators. However, under discharge condition (for example as a result of dry band arching) the LC magnitude should be combined by the THD to show a better correlation with the insulator condition. The product between THD and LC magnitude may be used as a diagnostic parameter.

Vertical Alignment of Liquid Crystal on Film of Plant-based Polysaccharide Derivatives

  • Yeonsu Cho;Jihyeon Moon;DaEun Yang;Hyo Kang
    • Elastomers and Composites
    • /
    • v.58 no.1
    • /
    • pp.1-10
    • /
    • 2023
  • In this study, we investigate the liquid crystal (LC) alignment of LC cells created from plant-based polysaccharide derivatives, such as guar gum. Guar gum films exhibit satisfactorily high optical transparency in the visible light region (400-750 nm). For example, the transmittance of polyimide films, which are the most typically used LC alignment layers, is 87%, whereas that of guar gum films deposited onto a glass substrate at a wavelength of 550 nm is approximately 99%. The observed LC alignment depends on the rubbing depth. For example, an LC cell comprising a guar gum film fabricated via rubbing at rubbing depths of 0.1, 0.2, 0.3, and 0.4 mm exhibits a planar LC alignment, whereas it exhibits a vertical LC alignment at a rubbing depth of 0.5 mm. Additionally, the LC alignment is shown to be correlated with the total surface energy of the guar gum films. When the total surface energy of a rubbed guar gum film exceeds 58.10 mJ/m2, an LC cell comprising the guar gum film exhibits a stable and vertical LC alignment. Therefore, guar gum can be used to realize the vertical alignment system of LC via a simple adjustment of the rubbing depth.

The Current and Power Waveform Improvement of an AC Motor with Low Pass LC Filter Driven by a Digital Bridge Inverter(II) (디지탈 브리지형 인버터로 구동되는 저역통과 LC 필터를 가진 교류전동기의 전류 및 전력의 파형 개선 (II))

  • 정주윤;박진길
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.19 no.4
    • /
    • pp.79-91
    • /
    • 1995
  • Recently, the AC motor which has a simple structure and needs less maintenance has become to be used frequently as a servomotor for position control in the automatic control field. This paper concerns with a method to improve the current and power waveforms of an AC motor, and the current waveforms and 3$\phi$ power waveforms are analyzed by FFT under verious running conditions. The system is composed of a digital bridge inverter, low pass LC filter, and 3$\phi$ AC motor. Through the computer simulations and experiments, it is confirmed that current waveforms and $\phi$ power waveforms con by improved by utilizing the high order low pass LC filter than that of lower order.

  • PDF

Dynamic Stability Depending on the Dielectric Anisotropy of the LC in the Fringe-Field Switching (FFS) mode (Fringe-Field Switching (FFS) 모드에서 액정의 유전율 이방성에 따른 동력학 안정성에 관한 연구)

  • 김미숙;김향율;이승희
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.3
    • /
    • pp.224-230
    • /
    • 2003
  • The voltage-dependent transmittance curve of a homogeneously aligned liquid crystal (LC) cell driven by fringe-electric field(named FFS mode) was studied, while changing dielectric anisotropy of a LC. The results show that for a LC with positive dielectric anisotropy while positioning at initial position. Therefore, we conclude that the dynamic stability is strongly dependent on the types of the LCs and voltage-dependent dynamics of the LC with negative dielectric anisotropy is staler than that of the LC with positive dielectric anisotropy in the FFS mode.

Wide Tuning Range Varactor Diodeless LC-tank VCO (Miller 커패시터를 이용한 넓은 가변 범위의 LC-tank 전압 제어 발진기)

  • Ryu, J.Y.;Ryu, S.T.;Jung, S.H.;Cho, G.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2579-2581
    • /
    • 2001
  • 넓은 가변 범위를 가지는 LC 탱크 전압 제어 발진기에 관해 본 논문에서 소개하고자 한다. LC 탱크 전압 제어 발진기의 발진을 소멸시키는 밀러 증폭기의 ESR을 제거함으로써 넓은 가변 범위를 얻을 수 있다. LC 탱크 전압 제어 발진기는 발진기 코어와 버퍼, 밴드갭(bandgap) 기준 전압 발생기 그리고 드라이브 증폭기로 구성되어 있다. 발진기 코어는 1.3mA의 전류를 소모하고 약 1GHz의 가변 범위를 가진다. 출력주파수의 가변 범위내에 발진기의 출력 전력은 3dBm 이내로 변한다. 이러한 LC 탱크 전압 제어 발진기는 BiCMOS 공정을 이용하여 제작되었고 2.7V 단일 전원에서 31.5mW의 전력을 소모한다.

  • PDF

A new metric for LCD temporal response;Dynamic gamma

  • Pan, Hao;Feng, Xiaofan;Daly, Scott
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.419-422
    • /
    • 2004
  • In this paper, we propose a new metric called "dynamic gamma" to quantitatively evaluate the dynamic temporal response of an LC display device. The widely-used response time and corresponding 3-D bar graphs cannot fully describe the dynamic characteristics of an LC panel [1], and using response time to compare different LC panels and assessing the dynamic features of LC panels is difficult. On the other hand, the new metric MPRT mixes an LC panel's slow temporal response with its hold-type display effect. The proposed new metric, dynamic gamma, and corresponding 2-D plots, are arguably more suitable for quantitatively characterizing the dynamic characteristics of an LC panel, so comparing two LC panels becomes easy. Furthermore, dynamic gamma has the unique property that it can be used to quantify the limitations/capabilities and to assess the effectiveness of an overdrive mechanism for a particular LCD. In the paper, two LC panels using different technology are analyzed and compared using this new metric.

  • PDF