• Title/Summary/Keyword: LC material

Search Result 544, Processing Time 0.027 seconds

Anti-inflammatory effects of Lycoris chejuensis callus using biorenovation (Biorenovation 기법 적용 제주상사화 callus의 항염증 활성)

  • Hyehyun Hong;Tae-Jin Park;Yu-Jung Lee;Jung-Hwan Kim;Seung-Young Kim
    • Journal of Applied Biological Chemistry
    • /
    • v.66
    • /
    • pp.197-203
    • /
    • 2023
  • Callus cultivation is a method for producing a large amount of tissue of a plant in the laboratory, regardless of the environment. Lycoris chejuensis, a plant species native to jeju island, is a member of the Lycoris family has been used as a traditional medicine for the treatment of diverse diseases. In this study, we evaluated anti-inflammatory effect of biorenovated Lycoris chejuensis callus (LCB) in lipopolysaccharide (LPS)-induced RAW264.7 cells. As a result, LCB was less toxic to the cells in the concentration range of 25, 50, and 100 ㎍/mL as shown by the improved viability of LCB treated cells than compared to Lycoris chejuensis callus (LC) treatment. In addition, LCB inhibited the generation of NO and prostaglandin E2 through the suppression of inducible nitric oxide synthase and cyclooxygenase-2 protein expression. LCB also attenuated the expression of interleukin-1β, interleukin-6 and tumor necrosis factor-α induced by LPS. The results suggest that LCB has anti-inflammatory activity on the LPS-induced inflammatory response and may be suitable for the development of potent functional cosmetic material.

Establishment of Biotin Analysis by LC-MS/MS Method in Infant Milk Formulas (LC-MS/MS를 이용한 조제유류 중 비오틴 함량 분석법 연구)

  • Shin, Yong Woon;Lee, Hwa Jung;Ham, Hyeon Suk;Shin, Sung Cheol;Kang, Yoon Jung;Hwang, Kyung Mi;Kwon, Yong Kwan;Seo, Il Won;Oh, Jae Myoung;Koo, Yong Eui
    • Journal of Food Hygiene and Safety
    • /
    • v.31 no.5
    • /
    • pp.327-334
    • /
    • 2016
  • This study was conducted to establish the standard method for the contents of biotin in milk formulas. To optimize the method, we compared several conditions for liquid extraction, purification and instrumental measurement using spiked samples and certified reference material (NIST SRM 1849a) as test materials. LC-MS/MS method for biotin was established using $C_{18}$ column and binary gradient 0.1% formic acid/acetonitrile, 0.1% formic acid/water mobile phase is applied for biotin. Product-ion traces at m/z 245.1 ${\rightarrow}$ 227.1, 166.1 are used for quantitative analysis of biotin. The linearity was over $R^2=0.999$ in range of $5{\sim}60{\mu}g/L$. For purification, chloroform was used as a solvent for eliminating lipids in milk formula. The linearity was over 0.999 in range of 5~60 ng/mL. The detection limit and quantification limit were 0.10, 0.31 ng/mL. The accuracy and precision of LC-MS/MS method using CRM were 103%, 2.5% respectively. Optimized methods were applied in sample analysis to verify the reliability. All the tested milk formulas were acceptable contents of biotin compared with component specification and standards for nutrition labeling. The standard operating procedures were prepared for biotin to provide experimental information and to strengthen the management of nutrient in milk formula.

THE EFFECTS OF NANO-SIZED HYDROXYAPATITE ON DEMINERALIZATION RESISTANCE AND BONDING STRENGTH IN LIGHT-CURED GLASS IONOMER DENTAL CEMENT (광중합형 글라스아이오노머 시멘트의 탈회 저항성과 결합 강도에 대한 나노미터 입자의 하이드록시아파타이트의 효과)

  • Kim, Ji-Hee;Lee, Yong-Keun;Kim, Seong-Oh;Song, Je-Seon;Choi, Byung-Jai;Choi, Hyung-Jun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.1
    • /
    • pp.24-34
    • /
    • 2010
  • The aim of this study was to evaluate the effect of incorporated nano HA on the demineralization resistance and bonding strength of LC GIC in comparison with micro HA. Fuji II LC GIC was used as the control group and a base material for experimental groups. Two experimental groups were prepared. One was prepared by adding 15% micro HA to LC GIC by weight ratio (Exp. 1), and the other was prepared by adding 15% nano HA instead (Exp. 2). According to the results, the following conclusions could be obtained. 1. Observing under the CLSM, the control group showed thicker enamel demineralization layer than in the experimental groups, and the Exp. 2 group showed the thinnest demineralization layer. 2. In SEM analysis, there was greater enamel demineralization in the control group. The Exp. 2 group was more resistant to demineralization compared to the Exp. 1 group. 3. The bonding strength was found to be in the increasing order of control, Exp. 1, and Exp. 2 group (p < 0.05). 4. Observing the fractured surfaces under SEM after the bonding strength test was performed, there were bone-like apatite particles formed in HA-added experimental groups, and a greater number of bone-like apatite particles were formed in the Exp. 2 group compared to the Exp. 1 group.

Comparison of flexural strength according to thickness between CAD/CAM denture base resins and conventional denture base resins (CAD/CAM 의치상 레진과 열중합 의치상 레진의 두께에 따른 굴곡 강도 비교)

  • Lee, Dong-Hyung;Lee, Joon-Seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.3
    • /
    • pp.183-195
    • /
    • 2020
  • Purpose: The purpose of this study is to compare the flexural strength of CAD/CAM denture base resins with conventional denture base resins based on their thicknesses. Materials and Methods: For the conventional denture base resins, Lucitone 199® (C-LC) was used. DIOnavi - Denture (P-DO) and DENTCA Denture Base II (P-DC) were taken for the 3D printing denture base resins. For the prepolymerized PMMA resins, Vipi Block Gum (M-VP) and M-IVoBase® CAD (M-IV) were used. The final dimensions of the specimens were 65.0 mm x 12.7 mm x 1.6 mm / 2.0 mm / 2.5 mm. The 3-point bend test was implemented to measure the flexural strength and flexural modulus. Microscopic evaluation of surface of fractured specimen was conducted by using a scanning electron microscope (SEM). After testing the normality of the data, one-way ANOVA was adopted to evaluate the differences among sample groups with a significance level of P = 0.05. The Tukey HSD test was performed for post hoc analysis. Results: Under the same thicknesses, there are significant differences in flexural strength between CAD/CAM denture base resins and conventional denture base resins except for P-DO and C-LC. M-VP showed higher flexural strength than conventional denture base resins, P-DC and M-IV displayed lower flexural strength than conventional denture base resins. Flexural modulus was highest in M-VP, followed by C-LC, P-DO, P-DC, M-IV, significant differences were found between all materials. In the comparison of flexural strength according to thickness, flexural strength of 2.5 mm was significantly higher than that of 1.6 mm in C-LC. Flexural strength of 2.5 mm and 2.0 mm was significantly higher than that of 1.6 mm in P-DC and M-VP. In M-IV, as the thickness increases, significant increase in flexural strength appeared. SEM analysis illustrates different fracture surfaces of the specimens. Conclusion: The flexural strength of different CAD/CAM denture base resins used in this study varied according to the composition and properties of each material. The flexural strength of CAD/CAM denture base resins was higher than the standard suggested by ISO 20795-1:2013 at a thickness of 1.6 mm or more though the thickness decreased. However, for clinical use of dentures with lower thickness, further researches should be done regarding other properties at lower thickness of denture base resins.

Development of the physical description area on filmstrips and slides in the British and American cataloging rules (영미계 목록규칙의 슬라이드자료에 대한 대조사항 기술형식의 변천)

  • 이창수
    • Journal of Korean Library and Information Science Society
    • /
    • v.10
    • /
    • pp.229-265
    • /
    • 1983
  • Many changes have been made on the cataloging rules on filmstrips and slides all the way from the Cox's rules of 1963 to AACR 2 of 1978. The purpose of this study is to analyze eight major British and American cataloging rules on filmstrips and slides, from the results of which to identify what major changes have been made chronologically, and to clarify major differences among them in describing the form ol Physical Description Area. The findings of the study can be summarized as follows: 1. In order to make a clear distinction from one element to the other in Physical Description Area, the use of punctuation has been made more concrete. In AACR 2, various punctuations in accordance with the each element's character are used. 2. The rules on the describing the number of physical units of filmstrips have got more and more specified. 3. The descriptive form of specific material designation is closely related to the existence or nonexistence of rules on the general material designation in the body of entry. Therefore, the rules of AECT and CLA having rules on the general material designation do not use the specific material designation in Physical Description Area. On the other hand, ISBD(NBM), LA rules and AACR 2 which makes it optional to use the general material designation prescribe to use the specific material designation. 4. As for the descriptions of the physical status other than the unit and size of the filmstrips and slides, the first LC card and Cox's rules, had the color designation, and the CLA rules had sound designation. In the LA rules, AACR1(Chapter 12 Revised) and AACR 2, the detailed description of the physical status including the indication of color, sound, kind of frame, time etc. has become more and more important for Physical Description Area. 5. All the rules adopt millimetre as the measuring unit of the size of filmstrips. For the slides, most rules employ inch instead. But LA rules and ISBD(NBM) use centimeters, and AACR 2 takes either inch or centimeters. 6. Most rules, including Cox's rules, give the information on the accompanying materials. The information has been added as the last element of the Physical Description Area in the AACR 2, and recognized very important.

  • PDF

Comparison of Microleakage and Compressive Strength of Different Base Materials (여러 치과 와동 기저재용 재료들의 미세누출 및 압축강도 비교)

  • Jang, Eunyeong;Lee, Jaesik;Nam, Soonhyeun;Kwon, Taeyub;Kim, Hyunjung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.2
    • /
    • pp.168-175
    • /
    • 2021
  • This study compared the microleakages and compressive strengths of various base materials. To evaluate microleakages, 50 extracted permanent premolars were prepared. The teeth divided into 5 groups of 10 each according to the base materials. Cavities with a 5.0 mm width, 3.0 mm length, and 3.0 mm depth were formed on the buccal surfaces of the teeth. After filling the cavities with different base materials, a composite resin was used for final restoration. Each specimen was immersed in 2% methylene blue solution and then observed under a stereoscopic microscope (× 30). To evaluate the compressive strength, 5 cylindrical specimens were prepared for each base material. A universal testing machine was used to measure the compressive strength. The microleakage was highest in the Riva light cureTM group and lowest in the BiodentineTM and Well-RootTM PT groups. For the compressive strengths, in all groups, acceptable strength values for base materials were found. The highest compressive strength was observed in the Fuji II LCTM group and the lowest strength in the Well-RootTM PT group.

Color Change in Tooth Induced by Various Calcium Silicate-Based Pulp-Capping Materials (수 종의 칼슘-실리케이트 치수복조제의 치관 색조 변화)

  • Jeon, Jiyoon;Choi, Namki;Kim, Seonmi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.3
    • /
    • pp.280-290
    • /
    • 2021
  • Color stability of pulp-capping material is considered vital to the final aesthetic result since the material is placed in the coronal area. The purpose of this study was to compare the color stability of various pulp-capping materials by analyzing color change of tooth over time. A cavity was formed in the crown of the extracted premolar, and 4 types of pulp-capping materials were filled. Color assessment was performed with a spectrophotometer at different intervals: before placement; immediately after material placement; 1 day, 1 week, 2 weeks, 4 weeks, 8 weeks, 12 weeks, and 16 weeks after placement. Proroot white MTA® and TheraCal LC® showed a significant decrease in the L* value and an increase in the ∆E* value over time. In contrast, Biodentine® and Well-RootTM PT showed no significant change in the L* value and maintained a steady ∆E* value. The application of pulp-capping materials containing bismuth oxide as a radiopacifier may result in a color change of teeth. Long-term color stability of pulp-capping materials should be considered when treating teeth with thin enamel thickness or in aesthetically important area.

Research on the Possibility of Using Wrinkle-improving Functional Materials from Corn By-products (옥수수 부산물을 이용한 주름 개선 기능성 소재 활용 가능성 연구)

  • Hye Jin Kim;Woo Seok Choi;June Seob Lee;Ja Young Kim;Moo-Han Kim;Chang Hyeon Lee
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.49 no.2
    • /
    • pp.107-116
    • /
    • 2023
  • In this study, to explore the possibility of using discarded by-products of corn as a wrinkle-improving functional material, the active ingredient contained in each part including kernel, cob, husk, and silk of 10 varieties of chodang and waxy corn was identified and the content was analyzed to suggest the possibility of corn by-products as upcycling materials. As a result of evaluating the collagen synthesis efficacy of extracts by part, the cob in chodang and waxy corns showed significant activity at 100 ㎍/mL concentration of 176.5 and 140.0%, respectively. The LC-MS/MS qualitative analysis resulted in the identification of 18 components in the cob, of which N, N'-diferuloylputrescine (DFP) was selected as an active ingredient, and the quantitative analysis was conducted by variety and part. As a result, DFP was confirmed only in the cob and kernel, and it was most frequently detected in the cob of the Goldsugar of chodang corn (39.6 ㎍/g) and Daehakchal of waxy corn (38.4 ㎍/g). The cob is a by-product left over from grain removal, and is expected to create new added value as a material that promotes collagen synthesis. Through this study, we propose the possibility of using discarded cob as a wrinkle-improving functional material.

A COMPARATIVE STUDY ON RADIOPACITY OF CANAL FILLING AND RETROGRADE ROOT-END FILLING MATERIALS (근관 충전재 및 치근단 역충전재의 방사선 불투과성에 관한 비교 연구)

  • Kim, Yong-Sang;Kim, Seo-Kyong;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.2
    • /
    • pp.107-114
    • /
    • 2008
  • This study was performed to assess the radiopacity of a variety of canal filling and retrograde root-end filling materials according to the specification concerning root canal obturation materials. Ten materials including Gutta-percha pellets, amalgam, Fuji II LC, $Dyract^{(R)}$ AP, Super $EBA^{(R)}$, $IRM^{(R)}$, AH $26^{(R)}$, $Sealapex^{TM}$, Tubli-$Seal^{TM}$, and dentin were evaluated in this study. In the first part, densitometric reading of an each step of aluminum step wedge on occlusal film were performed at 60 kVp (0.2, 0.3, 0.4 s), 70 kVp (0.2, 0.3, 0.33 s) to decide appropriate voltage and exposure time. In the second part, ten specimens which are 5 mm in diameter and 0.5, 1.0, 1.5, 2.0, 2.5, 3.0 mm in thickness, were fabricated from each material studied. The specimens were radiographed simultaneously with an aluminum step wedge under decided condition (60 kVp, 0.2 s). The mean radiographic density values of the materials were transformed into radiopacity expressed equivalent thickness of aluminum (mm Al). The following results were obtained. 1. Among the various conditions including 0.2 s, 0.3 s, 0.4 s at 60 kVp and 0.2 s, 0.3 s, 0.33 s at 70 kVp, the appropriate voltage and exposure time that meet the requirement of density from 0.5 to 2.0 was 0.2 s at 60 kVp. 2. All of the materials in this study had greater radiopacity than the minimun level recommended by ISO No. 4049 standards. 3. Most of the materials had greater radiopacity than 3 mm Al requirement of ANSI/ADA specification No. 57 (2000) and ISO No. 6876 (2001) standards except for Fuji II LC and Dyract. It suggests that all experimental canal filling and retrograde root-end filling materials have a sufficient radiopacity that meet the requirement concerning root canal obturation materials except for Fuji II LC and Dyract.

A Study on the Development Type of Component Joint Design for Environment Friendly Multi Housing Remodeling (공동주택의 친환경 리모델링을 위한 부품접합부 개선방안의 유형화에 관한 연구 II;욕실 및 주방을 중심으로)

  • Lim, Seok-Ho;Kim, Soo-Am;Hwang, Eun-Kyoung;Yun, Mae-Han
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.370-373
    • /
    • 2006
  • Lastly, the problem of filling occurs in the process of concealed joint of adjacent components and was seen in joints between the structure and an electrical or mechanical device. Therefore, the dry processing which replaces wet joint was seen in joints between the structure and a door, ones between the structure and a finishing materials, ones between a gypsum board and electrical device, and ones between a water pipe and a tile finishing. And a process of separating the area of jointed parts in order to eliminate the problem of overlap was seen in joints between a door and a finishing material and ones between a gypsum board on the ceiling and a light. Lastly, an analysis of a process of exposing concealed parts indicated that the problem of filling could be applied to joints between the structure and an electrical or mechanical device and ones between a finishing material and a mechanical device. This study sought out methods to apply Environment Friendly Multi Housing Remodeling that allow easy remodeling as part of environment- preserving policies. It also contains basic data useful to implement long-life houses in the future by presenting a comprehensive design standard for them

  • PDF