A design for the input filter and the output filter of a single-phase UPS system is proposed. And also, this paper describes a reduction of the DC voltage ripple of a single-phase UPS. The input power of proposed UPS fluctuates with twice frequency of the utility source, which causes DC voltage fluctuation. The reduction of the DC voltage fluctuation requires a large DC link capacitor. The proposed method uses a LC series resonant filter paralleled with a conventional smoothing capacitor. The effectiveness of the proposed method was confirmed by simulation results.
The recent flurry of activities and interest in Switched Reluctance Motor(SRM) has focused attention on various issues associated with implementing the SRM in the mass commertial Market. One such issue is the noise generated by radial force. In this paper, we proposed the circuit to reduce the noise of SRM using LC Resonant characteristic. The usefulness of proposed circuit is verified by experimental result.
본 연구는 저전압 교류 전류원으로부터 직류 부하에 에너지를 공급하기 위하여, 새로운 컨버터를 제안한다. 컨버터는 풀브리지 MOSFET 정류기와 플라이백 컨버터의 2단 구조로 구성되어 있으며, LC공진을 이용하여 AC/DC 전력변환을 수행한다. 컨버터 효율 개선을 위하여 컨버터 회로 내의 스위칭 소자는 3상한에서 동작한다. 제안된 컨버터의 동작원리 및 동작모드를 해석하고, 시뮬레이션을 통해 해석결과를 검증하였다.
본 논문에서는 고주파 공진형 인버터 접속의 가열 코일로부터 비접촉 상태로 전자유도 와전류를 구조물에 가하여 발열하는 공진형 인버터를 이용한 유도가열 방식의 최적설계를 제안하였다. 설계한 시스템 인버터는 스위칭주파수 20[kHz] 대역에서 동작하는 하프-브리지 고주파 직렬 부하 공진형이며 LC공진 설계 시 부하 자체를 L로 설정하여 효율을 최대화 하였다. 또한 유도가열용 인버터에 적용 가능한 스너버회로의 특성분석을 통해 본 시스템의 최적화에 관한 연구를 하였다.
Journal of the Institute of Electronics and Information Engineers
/
v.53
no.6
/
pp.155-166
/
2016
It is important to configure capacitance(C) of the capacitor and the induction coefficient(L) of the work coil on the resonant circuit design stage in order to induce heating on the object by a precise and constant frequency components in the electromagnetic induction heating equipment. Work coil conducts a direct induction heating according to heating point and area of the object which has a fixed heat factor so that work coil is designed to has fixed value. On the other hands, Capacitor should be designed to be changed in order to be the higher the utilization of the entire equipment. It is extracted the samples by variation of single electrode capacity from the selection stage of raw materials for capacity to the stage of process design for output of the high frequency LC resonance of 700kHz on 1000 VAC maximum voltage and current to $200I_{MAX}$. It is suggested fundamental experiment results in order to prove relation for the optimal design of HF-LC resonance conduction-cooled capacitor based on the response of frequency characteristics and results of output parameters according to variation of the capacitance size.
The Transactions of the Korean Institute of Power Electronics
/
v.20
no.5
/
pp.479-490
/
2015
The conventional phase-shifted full-bridge (PSFB) converter with an LC filter has been widely used for high-power applications of over 1.0 kW. However, the PSFB converter cannot obtain optimal power conversion efficiency during the battery charging in electric vehicle (EV) on-board battery charger applications because of its unique drawbacks, such as a large circulating current and very high voltage stress in the rectifier diodes. As a result, the converters with a capacitive filter, such as LLC resonant converters, replace the PSFB converter in the EV chargers. This study analyzes the problems of the PSFB converter for EV on-board charger applications in detail. Moreover, the newest converters based on the conventional PSFB converter are reviewed. On the basis of the reviews, new PSFB converter topologies are proposed for EV charger applications. The new topologies are formed by connecting the rectifier stage in the PSFB converter with the output of an LLC resonant converter in series. Many problems of the conventional PSFB converter for EV charger applications can be solved and the performance can be more improved because of this structure; this idea is confirmed by an experiment consisting of prototype battery chargers under the output voltage range of 250-450 Vdc at 3.3 kW.
Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
/
v.17
no.1
/
pp.1-9
/
2003
In this paper, prototype of high-power-factor single-stage electronic ballast for fluorescent lamp is designed and implemented. A new low cost single stage high power factor electronic ballast for fluorescent lamps is based on integration of two-boost converter and LC type high frequency resonant inverter. The proposed ballast is combined by simple construction, because full bridge rectifier diode is eliminated and simple control circuit is applied. Boost converter operate in the voltage of positive and negative half cycle respectively at line frequency (60㎐), operation in discontinuous conduction mode performs high power factor. The experimental results show the good performance as PF 0.99, THD 15.4%, and CF 1.65 at output 63.5〔W〕.
Kim, Ji-Hwan;Hwang, Sun-Hee;Ryu, Dong-Gyun;Jung, Doo-Yong;Jung, Yong-Chae;Won, Chung-Yuen
Proceedings of the KIPE Conference
/
2012.07a
/
pp.29-30
/
2012
In this paper, a performance of bi-directional DC/DC converter using PFM control at whole load range is analyzed. A bi-directional DC/DC converter using PFM control in this paper can be soft switching operation with LC series resonant circuit. It's difficult to expect a high efficiency at whole load range in general resonant converter because of limitation of soft switching area. Therefore converter used in this paper has a variable frequency PFM control to overcome a limitation of soft switching area and it makes a high efficiency at whole load range by implementing a soft switching at light load area of restricted soft switching. The high efficiency at whole load range is verified by simulation and experimental result.
Journal of the Korea Institute of Information and Communication Engineering
/
v.6
no.7
/
pp.1055-1061
/
2002
This paper deals with a design and fabrication of an electronic ballast for 70[W] ceramic discharge metal halide lamps. The proposed ballast is composed of a rectifier, an active power factor correction circuit (PFC), a half-bridge inverter, a LC resonant circuit and a microprocessor. The developed ballast also includes a specially designed time circuit which provides reignition signal of lamps. Running frequency of the ballast is .jet at 40[kHz] to avoid acoustic-resonance and flickering. From the experimental results, input power factor and efficiency of the ballast are estimated 99.8[%] and 93.1[%], respectively.
The Transactions of the Korean Institute of Electrical Engineers P
/
v.65
no.4
/
pp.285-291
/
2016
A light-emitting diode (LED) has been increasingly applied to various industrial fields and general lightings because of its high efficiency, low power consumption, environment-friendly characteristic and long lifetime. To drive the LED lighting, a power converter with the constant output current is needed. Among many power converters, the flyback converter is chosen by many converter designers due to high power density, structural simplicity, and miniaturization. In this converter, an electrolytic capacitor is generally chosen for the stabilization of the DC voltage because of having the large capacitance and the low price. However, the disadvantages are the short expected life time and 120Hz ripple currents on the converter output node. In this paper, a single-stage dimmable PFC DCM flyback converter without the electrolytic capacitor is proposed to prolong the lifetime of the LED driver. For the long lifetime of the converter, the polyester film capacitor with the small capacitance is substituted for the electrolytic capacitor on the output node and an LC resonant filter is added to damp 120Hz ripple current. The proposed converter is verified through the simulation and the experimental works.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.