• Title/Summary/Keyword: LC 필터

Search Result 183, Processing Time 0.024 seconds

Analysis of Output Characteristics and Design of LC Filter for Line-Interactive 3-Phase APF (3상 라인인터액티브형 능동전력필터 시스템을 위한 LC필터 출력특성 해석 및 설계)

  • 김응진
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.127-132
    • /
    • 2000
  • This paper describes a 3-phase Line-Interactive APF system and analyzes its operating characteristics considering LC Filter output characteristics. Topology of APF is similar to that of Off-Line UPS in the point of parallelly operating inverter system. So it is possible to be multi-functioned active compensating system according to power condition. Likewise this actively operating system from APF to UPS and vice versa is often to be called Line-Interactive system. And more than that Line-Interactive system needs precise design of LC filter on converter output side to make this system fully operate in both APF and UPS modes. The problem in this point is how to design LC Filter to be contented with two different system characteristics so this paper analyzes this problem and proposes its design procedures. Then suggested filter design is verified to be contented by the simulations and experimental results

  • PDF

Control of two-stage low-frequency square-wave electronic ballast with resonant ignition using a ZVS (ZVS를 이용한 공진 점등 저주파수 구형파 전자식 안정기 제어방법)

  • Kim, Hyung-Bae;Yoo, Chang-Gyu;Lee, Woo-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2009.11a
    • /
    • pp.182-184
    • /
    • 2009
  • 본 논문은 램프 점등을 위한 공진회로와 정상상태에서의 저주파수 구형파(low frequency square-wave) 인버터 전류 제어를 실현하는 HID 전자식 안정기에 풀브리지 인버터(FB)와 LC 필터를 제안한다. 점등은 LC필터의 공진주파수에서 풀브리지 인버터 제어에 의한 공진에 의해서 이루어지고, 점등 후에 회로는 풀브리지 제어에 의해 벅컨버터 저주파수 구형파 인버터로 동작한다. 점등이 일어나는 동안의 LC필터의 공진주파수는 ($f_o$=120kHz)이고, 고조파를 감소시키고 음향공명현상을 피하기 위한 벅컨버터스위칭 주파수($f_{sw}$=50kHz)를 선택하였다.

  • PDF

Characteristics of AC Filters on Residential ESS-PCS using Utility Transformer (상용변압기를 사용한 가정용 ESS-PCS의 출력필터 특성)

  • Jung, Haemin;Lee, Jinsung;Kim, Hyosung
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.289-290
    • /
    • 2014
  • 3kWh 급 가정용 Energy Storage System (ESS)는 배터리 팩의 수명 관리상 배터리팩의 전압을 48V의 공칭전압으로 설계하는 것이 일반적이다. 상용 변압기를 사용하여 48V의 낮은 직류 링크 전압을 갖는 ESS를 220V 교류 계통과 연계하기 위하여는 30V 정도의 낮은 인버터 출력단 교류전압을 220V로 승압하여야 한다. 이 경우 ESS의 교류 측 전압 및 전류 파형을 정형적으로 만들어주기 위한 LC 필터 요소로서 저전압/대전류 용 필터 인덕터를 제작하는 것이 쉽지 않다. 다시 말해, 성능이 보장된다면 교류 측 LC 필터를 상용 변압기의 고전압 측에 설치하는 것이 바람직하다. 본 논문에서는 상용 변압기를 사용하는 가정용 ESS의 교류 측 필터의 설치 위치에 따른 설계 및 제작 시 고려 사항과 특성에 대하여 연구하였다.

  • PDF

The Output Characteristics Analysis by Cut-off Frequency Set-up of the LCR Filter on NPC Multi-Level Inverter with Trap-Filter (트랩필터를 갖는 NPC멀티레벨 인버터의 LCR필터 차단주파수 설정에 따른 출력특성 분석)

  • Kim, Soo-Hong;Kim, Yoon-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.5
    • /
    • pp.892-897
    • /
    • 2007
  • This paper presents the output filter design and the output characteristic analysis by cut-off frequency set up of the LCR filter on NPC multi-level inverter with trap-filter. The single-phase NPC three-level inverter operates at low switching frequency. The proposed LC trap filter is comprised of a conventional LCR output filter, by using LC trap filter the need for high damping resistor and low LC cut-off frequency is eliminated. Also. low damping resistor is increased the output filter system. The multilevel inverter system used NPC type inverter in proper system for high power application and controller is used DSP(TMS320C31). The effectiveness of proposed system confirmed the validity through SPICE simulation and experimental results.

A Study on the Output Noise Reduction of 3-Phase 3-Level Inverter (3상 NPC 3레벨 인버터 출력노이즈 저감에 관한 연구)

  • Kim, Soo-Hong;Jin, Kang-Hwan;Kim, Yoon-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.1
    • /
    • pp.9-14
    • /
    • 2008
  • Since they use the low switching frequency in multilevel inverter systems, they generate the high low frequency harmonic components. Generally, LC filter is used at the output terminal of inverter systems to solve this problem. But it causes a voltage drop at the output terminal by use of damping resistors, and causes the problem in which system efficiency decreases due to power loss of the damping resistor. In this paper, we proposed an output filter design method for NPC three-level inverter systems with low switching frequency. And we analyzed the efficiency of the proposed filter system, and the effectiveness of the proposed system is verified by simulation and experimental results.

An active damping method of a grid connected LCL-filter using a notch filter (노치필터를 이용한 계통연계 LCL필터의 능동 댐핑 방법)

  • Kang, Yikyu
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.155-156
    • /
    • 2014
  • 본 논문은 계통연계 목적으로 사용하는 LCL필터의 공진현상을 억제하기 위한 간단한 능동 댐핑 원리와 방법을 보인다. LCL필터는 기존의 1차 필터인 L필터에 비해 적은 동량으로 효과적인 출력파형의 고조파 저감 효과를 갖지만, LC파트 추가로 인해 허수축에 공진복소극이 존재하여 필연적으로 시스템에 공진이 발생하게 된다. 본 논문에서는 추가적인 센서나 수동소자의 사용 없이 LCL필터의 공진복소극을 상쇄하는 노치필터를 제어기에 적용하여 시스템의 안정성을 확보한다. 시뮬레이션을 수행하여 타당성을 입증한다.

  • PDF

Design and Implementation of Double Down-Converter for Satellite TV (위성 TV용 이중 하향 변환기의 설계 및 제작)

  • Lee, Seung-Dae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.840-845
    • /
    • 2013
  • In this paper, the broadband frequency double down-converter based on LC filter technologies has been designed and implemented, and its performances are introduced. The Designed frequency double down-converter is consisted with a low-noise amplifier, mixer, IF amplifier, LC filter, DC-block capacitor and RF-bypass capacitor. Especially, instead of active devices of a typical converter, the suggested converter designed using passive devices to provide both low-power consumption and low-cost model. As results of the measurement, the implemented frequency double down-converter realizes the broadband performance with the bandwidth of 100MHz (13~113MHz) at the center frequency of 63MHz, and its gain is approximately 40dB.

Design of the LC Filter Considering Total Harmonic Distortion (THD를 고려한 DVR 시스템의 LC필터 설계)

  • Kim, Wang-Rae;Lim, Byung-Kuk;Shon, Jin-Geun;Jeon, Hee-Jong
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.490-493
    • /
    • 2005
  • In order to reduce the harmonics in invertor output of the DVR system, typically LC filter is employed. In designing the LC filter, it is required to consider the gild impedance and the characteristic of the harmonics. In this paper, problems in the conventional way of designing the LC filter is analyzed and new LC fitter design technique is proposed. In the proposed technique, parameters of the LC filter are calculated considering grid impedance, THD, DC link voltage and phase lag. The validity and feasibility of the proposed method is verified through the simulations experiments. The DVR system with the proposed LC filter is being built and tested.

  • PDF

Predictive Control for Parallel Multi-module UPS Inverters with Output LC Filter (병렬 멀티-모듈 UPS 인버터의 출력 LC필터를 이용한 예측제어)

  • Park, Jung-Min;Lee, Kang-Hyun;Jung, Won-Sang;Park, Yun-Ji;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.258-259
    • /
    • 2017
  • 본 논문에서는 병렬 멀티-모듈 UPS 인버터의 출력 LC필터를 이용한 예측제어를 제안한다. 부하의 용량증가에 따라 단상 UPS 모듈을 병렬로 증가시켜 UPS 용량 증설하는 연구가 진행되고 있다. 이러한 UPS 시스템을 제어하기 위해 기존 제안하였던 전류 예측 제어에서는 PI 전압 제어로 인해 UPS 모드 절환 시 제한된 동적 반응(Dynamic response)을 갖는 단점이 있었다. 이러한 문제점을 보완하기 위해, 본 논문에서는 PI 전압제어를 전압 예측 제어로 대체함으로써 보다 빠른 동적 반응을 가질 수 있는 전압 및 전류 예측제어를 제안한다. 제안한 제어기법의 타당성은 수학적 분석 및 시뮬레이션을 통해 검증하였다.

  • PDF

Damping of Output LC filter Resonance Based on Aliasing Phenomenon for Motor Drive Inverter (전동기 구동 인버터에서 Aliasing 현상을 이용한 LC필터 공진 현상 억제)

  • Shin, Dongho;Kim, Jaesuk;Sul, Seung-Ki
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.104-105
    • /
    • 2017
  • 본 논문에서는 전동기를 구동하는 인버터 출력단에 있는 LC필터의 공진현상을 피하기 위한 능동감쇠 방법을 제안하였다. 기존의 방법들은 추가적인 센서 혹은 복잡한 신호처리를 필요로 한다. 이에 비해 제안된 방법은 기존의 방법과 달리 샘플링 주파수를 변경하여 추가적인 제어 없이 공진 문제를 해결한다. 제어 시스템이 특정한 조건을 만족하는 경우, 샘플링 주파수를 공진 주파수와 일치시켜 공진 전류를 Aliasing된 형태의 저주파수 성분으로 계측한 후, 이를 통해 시스템의 안정성을 확보하여 공진현상을 억제한다. 이산 시간(discrete-time)에서의 모델링을 통해 제안된 방법의 안정성 여부를 확인하였고, 최종적으로 실험을 통해 제안된 능동감쇠 방법의 유효성을 검증하였다.

  • PDF