• Title/Summary/Keyword: LC 필터

Search Result 183, Processing Time 0.029 seconds

Surge Protective Device Combined with Varistor and LC Filter on AC Power Circuits (바리스터와 LC필터를 조합한 교류 전원용 서지보호장치)

  • 이복희;이경옥;안창환;이승칠;박정웅
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.4
    • /
    • pp.109-116
    • /
    • 1997
  • This paper describes the surge protective device combined with varistor and LC low pass filter on AC power circuits. Up to now varistors alone have been used as a surge protective device on AC power circuits, but it gives negative effects on the equipments to be protected due to the steep rise and high remnant voltage. Therefore in this work, for the purpose of improving the cutoff performance of surge protective device on AC power circuits, the hybrid-type surge protective device with varistor and LC filter was designed and prepared. And the experiments for operational characteristics and clamping performance of the surge protective device were carried out with an 1.2/50[$\mu$s] impulse generator. As a result, the proposed surge protective device with the combination of varistors and LC filter can limit the surge voltage to lower value and reduce the value of dV /dt to very small values. Also the attenuation of high-frequency voltages across the output port is effectively provided by LC filter. Therefore this result may be all the more helpful avoiding both damage and upset of electronic systems.

  • PDF

The Current and Power Waveform Improvement of an AC Motor with Low Pass LC Filter Driven by a Digital Bridge Inverter(I) (디지탈 브리지형 인버터로 구동되는 저역통과 LC 필터를 가진 교류전동기의 전류 및 전력의 파형 개선 (I))

  • 정주윤;박진길
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.19 no.3
    • /
    • pp.107-118
    • /
    • 1995
  • The characteristics of the current waveforms and 3$\Phi$ power waveforms of the variable speed 3$\Phi$ AC motor system driven by the single-pulse PWM investigated in this paper. The system is composed of a digital bridge inverter and low pass LC filter. It is confirmed that current waveforms and 3$\Phi$ power waveforms can be improved by utilizing the high order low pass LC filter than that of lower order through computer simulation. Also, we propose the low pass LC filter revised from the conventional LC filter.

  • PDF

A Study on Filter Efficiency Analysis and Harmonic Reduction of Single Phase NPC Multi-Level Inverter with LC-Trap Filter (LC트랩필터를 갖는 단상 NPC 멀티레벨 인버터의 출력 고조파 저감 및 필터 효율 분석에 관한 연구)

  • Kim Soo-Hong;Seo Kang-Moon;Kim Yoon-Ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.8
    • /
    • pp.430-435
    • /
    • 2006
  • This paper presents a method about the efficiency analysis and the harmonic reduction of single phase NPC multi-level inverter with LC-trap filter and LCR output filter. The proposed LC-trap filter is comprised of a conventional LC output filter, by using LC-trap filter the need for high damping resistor and low LC cut-off frequency is eliminated. Also, low damping resistor is increased the efficiency of the output filter. Experimental verification of the proposed circuit is provided with single phase NPC multilevel inverter system and DSP controller.

A Study on the Speed Control System of a 3 phase Induction Motor driven by the Full Bridge Inverter with a Low Pass LC Filter (저역통과 LC필터를 가진 전브리지형 인버터로 구동되는 3상유동전동기의 속도제어 시스템에 관한 연구)

  • 박진길
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.4
    • /
    • pp.538-550
    • /
    • 1998
  • The variable frequency and variable voltage AC source made by a conventional inverter which is composed of power semi-conductors includes much noises in sine wave due to high frequency switching of DC source. In this paper the 3rd low pass LC filter for a variable speed 3 phase induction motor driven by a full bridge inverter is introduced to solve the EMI problem by serious noise current. The utility of a modified 3rd order Butterworth LC filter is confirmed through FFT analysis of sine waves and noiseless ACsource can be obtained by the proposed LC filter. The speed of a 3 phase induction motor driven by a full bridge inverter with a LC filter is satisfactorily controlled by a digital PID controller under the condition of stepwise load and setpoint changes.

  • PDF

High Power Factor 3-Phase AC-DC Converter without LC Filter (LC필터가 없는 고역율 3상 AC-DC 컨버터)

  • Nam, Jing-Rak
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.10
    • /
    • pp.1894-1898
    • /
    • 2007
  • Conventional 3-phase AC-DC converter is frequently in the industrial world. In this paper, the high power factor 3-phase AC-DC converter which can reduce its weight and volume is proposed. The high power factor 3-phase AC-DC converter without LC filter can realize light weight and low-cost. In spite of elimination of LC filter, the performance of the high power 3-phase AC-DC converter is almost the same as conventional 3-phase AC-DC converter. Finally, this result can be expected to be applied to aviation and the space industry with high power density and high power factor.

Design of Wideband Facility Power-line EMI filter (광대역 설비용 전원선 EMI 필터의 설계)

  • Chung, Se-Kyo;Lim, Jeong-Gyu;Kim, Mu-Hyun;Kang, Byoung-Kuk
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.440-448
    • /
    • 2009
  • Facility power-line electromagnetic interference (EMI) filters are used to provide radio frequency(RF) isolation between dedicated power distribution services and noise sensitive local power distribution systems. This type of EMI filters generally needs a high current capacity and, in some special applications, a high insertion loss of a minimum 100dB from 14kHz through 10GHz per MIL-STD 220 is required. This paper deals with an analysis and design of a wideband facility power-line EMI filter with the above requirements. The characteristics of the inductor and capacitor at high frequencies are investigated. The characteristics and design method of the facility EMI filter with a high order LC network are also presented. The prototype filter is finally implemented and its performance is verified from the experimental results.

Nonlinear Control of Output Voltages of PWM Inverters for Stand-Alone Wind Power Generation (독립형 풍력발전용 PWM 인버터의 출력전압의 비선형 제어)

  • Jang, Jeong-Ik;Koo, Seoung-Young;Lee, Dong-Choon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.2
    • /
    • pp.131-138
    • /
    • 2007
  • In this paper, a novel nonlinear control method of the CVCF(constant voltage and constant frequency) output voltage for the three-phase PWM inverter with LC output filters is proposed. A nonlinear modeling including the output LC filters is linearized by feedback linearization theory, the controllers of which can be designed based on a linear control theory. It is applied to the DC/AC power conversion of the PWM inverter for stand-alone wind power generation system. It has been verified by the experimental results that the proposed control scheme gives high dynamic responses at load variation as well as a zero steady-state error.

The Current and Power Waveform Improvement of an AC Motor with Low Pass LC Filter Driven by a Digital Bridge Inverter(II) (디지탈 브리지형 인버터로 구동되는 저역통과 LC 필터를 가진 교류전동기의 전류 및 전력의 파형 개선 (II))

  • 정주윤;박진길
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.19 no.4
    • /
    • pp.79-91
    • /
    • 1995
  • Recently, the AC motor which has a simple structure and needs less maintenance has become to be used frequently as a servomotor for position control in the automatic control field. This paper concerns with a method to improve the current and power waveforms of an AC motor, and the current waveforms and 3$\phi$ power waveforms are analyzed by FFT under verious running conditions. The system is composed of a digital bridge inverter, low pass LC filter, and 3$\phi$ AC motor. Through the computer simulations and experiments, it is confirmed that current waveforms and $\phi$ power waveforms con by improved by utilizing the high order low pass LC filter than that of lower order.

  • PDF

Desing of LCL filter for Grid connected 3-Level inverter (계통 연계형 3-Level inverter의 LCL filter 설계)

  • Lim, Sangmin;Kim, Jaeseob;Choi, Jaeho;Son, Kyungmin
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.489-490
    • /
    • 2013
  • 계통 연계형 발전시스템은 스위칭 주파수를 기본으로 하는 배수 고조파들이 발생한다. 이 때 인버터의 출력 전류 고조파는 계통의 전력품질에 영향을 주므로 저역통과 필터를 이용하여 제거해 주어야 한다. 일반적으로 사용하는 L, LC필터는 구성이 간단하고 제어가 용이한 장점이 있지만 동적특성이 좋지 않고 필터의 성능향상을 위해서는 인덕턴스를 증가시켜야 하기 때문에 필터의 부피가 커지는 단점을 가지고 있다. 이에 반해 LCL필터는 LC필터에 비해 더 낮은 용량으로 높은 고조파 감쇄 효과를 구현 할 수 있다는 장점이 있다. 그리고 2레벨 인버터에 비해 3레벨 인버터는 높은 효율과 낮은 THD발생으로 계통 연계 시스템에 많이 적용되고 있다. 본 눈문에서는 계통연계형 3레벨 인버터의 LCL필터 설계를 하여 이를 컴퓨터 시뮬레이션과 실험을 통하여 타당성을 검증한다.

  • PDF