• Title/Summary/Keyword: LAT

Search Result 248, Processing Time 0.027 seconds

Structure of the Galactic Foreground

  • Ahn, Hyeseong;Cho, Jungyeon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.2
    • /
    • pp.68.4-68.4
    • /
    • 2019
  • In this poster, we present a relation between the Galactic foregrounds and Galactic latitude to study the structure of the Galactic foregrounds. We propose that the standard deviation of observed values along a line of sight with Galactic latitude b ('σl.o.s') is inversely proportional to ${\sqrt{sin{\mid}b{\mid}}}$. To confirm this, we use synchrotron intensity data from the Planck archive and rotation measure (RM) data from the NVSS. We divided the sphere of the Galactic coordinate into bins with a constant surface area and calculated the average of standard deviation along Galactic latitude ('σlat'). We compared σlat ${\sqrt{sin{\mid}b{\mid}}}$ with σlat along Galactic latitude and found that σlat ${\sqrt{sin{\mid}b{\mid}}}$ is the most constant. These results support that the relation is reasonable.

  • PDF

Evaluation of Combine IGRT using ExacTrac and CBCT In SBRT (정위적체부방사선치료시 ExacTrac과 CBCT를 이용한 Combine IGRT의 유용성 평가)

  • Ahn, Min Woo;Kang, Hyo Seok;Choi, Byoung Joon;Park, Sang Jun;Jung, Da Ee;Lee, Geon Ho;Lee, Doo Sang;Jeon, Myeong Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.201-208
    • /
    • 2018
  • Purpose : The purpose of this study is to compare and analyze the set-up errors using the Combine IGRT with ExacTrac and CBCT phased in the treatment of Stereotatic Body Radiotherapy. Methods and materials : Patient who were treated Stereotatic Body Radiotherapy in the ulsan university hospital from May 2014 to november 2017 were classified as treatment area three brain, nine spine, three pelvis. First using ExacTrac Set-up error calibrated direction of Lateral(Lat), Longitudinal(Lng), Vertical(Vrt), Roll, Pitch, Yaw, after applied ExacTrac moving data in addition to use CBCT and set-up error calibrated direction of Lat, Lng, Vrt, Rotation(Rtn). Results : When using ExacTrac, the error in the brain region is Lat $0.18{\pm}0.25cm$, Lng $0.23{\pm}0.04cm$, Vrt $0.30{\pm}0.36cm$, Roll $0.36{\pm}0.21^{\circ}$, Pitch $1.72{\pm}0.62^{\circ}$, Yaw $1.80{\pm}1.21^{\circ}$, spine Lat $0.21{\pm}0.24cm$, Lng $0.27{\pm}0.36cm$, Vrt $0.26{\pm}0.42cm$, Roll $1.01{\pm}1.17^{\circ}$, Pitch $0.66{\pm}0.45^{\circ}$, Yaw $0.71{\pm}0.58^{\circ}$, pelvis Lat $0.20{\pm}0.16cm$, Lng $0.24{\pm}0.29cm$, Vrt $0.28{\pm}0.29cm$, Roll $0.83{\pm}0.21^{\circ}$, Pitch $0.57{\pm}0.45^{\circ}$, Yaw $0.52{\pm}0.27^{\circ}$ When CBCT is performed after the couch movement, the error in brain region is Lat $0.06{\pm}0.05cm$, Lng $0.07{\pm}0.06cm$, Vrt $0.00{\pm}0.00cm$, Rtn $0.0{\pm}0.0^{\circ}$, spine Lat $0.06{\pm}0.04cm$, Lng $0.16{\pm}0.30cm$, Vrt $0.08{\pm}0.08cm$, Rtn $0.00{\pm}0.00^{\circ}$, pelvis Lat $0.06{\pm}0.07cm$, Lng $0.04{\pm}0.05cm$, Vrt $0.06{\pm}0.04cm$, Rtn $0.0{\pm}0.0^{\circ}$. Conclusion : Combine IGRT with ExacTrac in addition to CBCT during Stereotatic Body Radiotherapy showed that it was possible to reduce the set-up error of patients compared to single ExacTrac. However, the application of Combine IGRT increases patient set-up verification time and absorption dose in the body for image acquisition. Therefore, depending on the patient's situation that using Combine IGRT to reduce the patient's set-up error can increase the radiation treatment effectiveness.

  • PDF

The effects of traditional acupuncture techniques and green laser acupuncture on the blood pressure in hypertensive rat induced by two kidney one clip (신문(神門), 태백혈(太白穴)에 시행된 직자법(直刺法), 수기사법(手技瀉法) 및 침습형 레이저 시술이 고혈압 백서에 미치는 영향)

  • Na, Chang-Su;Youn, Dae-Hwan;Choi, Chan-Hun;Lee, Suk-Hee;Oh, Kwang-Hwan;Jeong, Sung-Ho
    • Korean Journal of Acupuncture
    • /
    • v.25 no.2
    • /
    • pp.199-210
    • /
    • 2008
  • Objectives : This study was performed to investigate the effect of invasive laser acupuncture therapy with green light (LAT-G) at HT7(Sinmun), SP3(Taebaek) on the blood pressure in hypertensive rat induced by two kidney one clip. Methods : The experiments were performed on Sprague Dawley rats. 2K1C hypertension model was prepared by constricting the left renal artery with a sliver clip. Animals were divided into four groups, which were simple acupuncture treatment group with straight needle insertion on the square(AT-SS), acupuncture treatment group with reducing manipulation in the opposite channel direction(AT-RD), laser acupuncture treatment group with green light 532 nm, 10mW power in the opposite channel direction(LAT-G10) and laser acupuncture treatment group with green light 532 nm, 20mW power in the opposite channel direction(LAT-G20). The treatments were performed once per two days for 10 days. Results : Body weight was increased significantly in LAT-G20 group compared with AT-RD group. The blood pressure was significantly decreased in LAT-G20 and LAT-G10 groups compared with AT-SS group. Conclusions : These results suggest that green laser acupuncture therapy at SP3 ${\cdot}$ HT7 is more effective than straight needle insertion on the square for controlling hypertension. It is possible that invasive green laser acupuncture therapy (532 nm) can be used as a reducing method of the traditional acupuncture techniques.

  • PDF

Comparison of alkaline phosphatase activity of MC3T3-E1 cells cultured on different Ti surfaces: modified sandblasted with large grit and acid-etched (MSLA), laser-treated, and laser and acid-treated Ti surfaces

  • Li, Lin-Jie;Kim, So-Nam;Cho, Sung-Am
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.3
    • /
    • pp.235-240
    • /
    • 2016
  • PURPOSE. In this study, the aim of this study was to evaluate the effect of implant surface treatment on cell differentiation of osteoblast cells. For this purpose, three surfaces were compared: (1) a modified SLA (MSLA: sand-blasted with large grit, acid-etched, and immersed in 0.9% NaCl), (2) a laser treatment (LT: laser treatment) titanium surface and (3) a laser and acid-treated (LAT: laser treatment, acid-etched) titanium surface. MATERIALS AND METHODS. The MSLA surfaces were considered as the control group, and LT and LAT surfaces as test groups. Alkaline phosphatase expression (ALP) was used to quantify osteoblastic differentiation of MC3T3-E1 cell. Surface roughness was evaluated by a contact profilometer (URFPAK-SV; Mitutoyo, Kawasaki, Japan) and characterized by two parameters: mean roughness (Ra) and maximum peak-to-valley height (Rt). RESULTS. Scanning electron microscope revealed that MSLA (control group) surface was not as rough as LT, LAT surface (test groups). Alkaline phosphatase expression, the measure of osteoblastic differentiation, and total ALP expression by surface-adherent cells were found to be highest at 21 days for all three surfaces tested (P<.05). Furthermore, ALP expression levels of MSLA and LAT surfaces were significantly higher than expression levels of LT surface-adherent cells at 7, 14, and 21 days, respectively (P<.05). However, ALP expression levels between MSLA and LAT surface were equal at 7, 14, and 21 days (P>.05). CONCLUSION. This study suggested that MSLA and LAT surfaces exhibited more favorable environment for osteoblast differentiation when compared with LT surface, the results that are important for implant surface modification studies.

Evaluation of the Patient Dose in Case of Standard Radiographic Examinations Using CR and DR (표준영상의학검사를 대상으로 한 CR과 DR에서의 환자선량평가)

  • Kim, Sang-Tae;Han, Beom-Hui
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.173-178
    • /
    • 2010
  • In projection radiography, two types of digital imaging systems are currently available, computed radiography (CR) and digital radiography (DR): a difference between them can be stated in terms of dose and image quality. In the Department of Radiology our hospital, a flat-panel DR equipment (Digital diagnost, Philips) and two CR systems (ADC Compact plus digitizer, AGFA) are employed. Eight standard radiographic examinations (Skull AP, Skull LAT, Chest PA, Chest LAT, Abdomen AP, L-spine AP, L-spine LAT, Pelvis AP) were considered: doses delivered to patients in terms of both entrance skin dose (ESD) were calculated and compared in order to study the dosimetric discrepancies between CR and DR. Assessment of image quality is undertaken by Consultant Radiologists to ensure that the quality criteria for diagnostic radiographic images of the European guidelines were met. Results showed that both ESD in DR are lower than that in CR; all images met the criteria in the European Guidelines for both modalities and were used for reporting by the radiologists. Since the operators are the same and the image quality is comparable in both modalities, this study shows that in the considered examinations, DR can perform better than CR from a dosimetric point of view.

Anti-apoptotic and Neuroprotective Effects of Acupuncture at $LR_3$ on Focal Brain Ischemic Injury Induced by Intraluminal Filament Insertion in Rats (다종(多種)의 태충(太衝)($LR_3$) 침척요법(鍼刺療法)이 Intraluminal Filament 삽입술로 유발된 백서(白鼠)의 허혈성 국소 뇌손상에 미치는 영향)

  • Yim, Hyun-Jin;Cho, Myung-Rae;Youn, Dae-Hwan;Na, Chang-Su;Ryu, Chung-Ryeol
    • Journal of Acupuncture Research
    • /
    • v.24 no.2
    • /
    • pp.125-140
    • /
    • 2007
  • Objectives: This study was performed to investigate the effects of acupuncture therapy(AT, AT-9), electro-acupuncture therapy(EAT) and low level laser acupuncture therapy(LAT) at LRJ on the focal ischemia-induced by intraluminal filament insertion in rats. Methods : In the present syudy, the focal ischemia was induced by Intraluminal filament insertion into left middle cerebral artery. The subjects were divided into five groups after focal brain ischemia. (n=15, in each group) : Control with no treatment, AT with acupuncture at $LR_3$, AT-9 with acupuncture at $LR_3$ and rotating 9 times in a clockwise direction, EAT with electro-acupuncture at $LR_3$ and LAT with invasive laser acupuncture at $LR_3$. Anti-apoptotic and neuroprotective effects of acupuncture were observed by mGluR5 mRNA, Bax mRNA, Bcl-2 mRNA, Cytochrome C protein, Cresyl violet-stain and Choline acetyltransferase (ChAT)-stain in the hippocampus. Results: 1. In LAT, mGluR5, Cresyl violet-stain and ChAT-stain were increased. 2. In LAT, Cytochrome C protein was decreased. 3. In AT-9, Bax, Cytochrome C protein and the Bax/Bcl-2 ratio were decreased. 4. In AT-9, Bcl-2, Cresyl violet-stain and ChAT-stain were increased. 5. In EAT, Bcl-2 and Cresyl violet-stain were increased. Conclusions: These results suggests that LAT and AT-9 show anti-apoptotic and neuro-protective effects and that LAT and AT-9 may be useful for managing stroke by focal brain ischemia.

  • PDF

Analysis on the estimation errors of the lowest and highest astronomical tides for the southwestern 2.5 GW offshore wind farm, Korea

  • Ko, Dong Hui;Jeong, Shin Taek;Cho, Hong-Yeon;Kang, Keum-Seok
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.10 no.1
    • /
    • pp.85-94
    • /
    • 2018
  • For the design of wind-power facilities, the highest and lowest astronomical tides (HAT and LAT, respectively) are needed for the tidal-water levels regarding international designs; however, the approximate highest high water and approximate lowest low water AHHW and ALLW, respectively, have been used in Korea. The HAT and LAT in the wind-farm test-bed sea should be estimated to satisfy the international standard. In this study, the HAT and LAT are therefore estimated using the hourly tidal-elevation data of the Eocheongdo, Anmado, Younggwang, Gunsan, Janghang, and Seocheon tidal-gauging stations that are located in the adjacent coastal sea. The nodal variation patterns of the major lunar components, such as $M_2$, $O_1$, and $K_1$ are analyzed to check the expected long-term lunar cycle, i.e., 18.61 year's nodal-variation patterns. The temporal amplitude variations of the $M_2$, $O_1$, and $K_1$ clearly show the 18.61-years periodic patterns in the case of the no-nodal correction condition. In addition, the suggested HAT and LAT elevations, estimated as the upper and lower confidence limits of the yearly HAT and LAT elevations, are 50 cm greater than the AHHW and 40 cm lower than the ALLW, respectively.

Comparison of Machine Learning Classification Models for the Development of Simulators for General X-ray Examination Education (일반엑스선검사 교육용 시뮬레이터 개발을 위한 기계학습 분류모델 비교)

  • Lee, In-Ja;Park, Chae-Yeon;Lee, Jun-Ho
    • Journal of radiological science and technology
    • /
    • v.45 no.2
    • /
    • pp.111-116
    • /
    • 2022
  • In this study, the applicability of machine learning for the development of a simulator for general X-ray examination education is evaluated. To this end, k-nearest neighbor(kNN), support vector machine(SVM) and neural network(NN) classification models are analyzed to present the most suitable model by analyzing the results. Image data was obtained by taking 100 photos each corresponding to Posterior anterior(PA), Posterior anterior oblique(Obl), Lateral(Lat), Fan lateral(Fan lat). 70% of the acquired 400 image data were used as training sets for learning machine learning models and 30% were used as test sets for evaluation. and prediction model was constructed for right-handed PA, Obl, Lat, Fan lat image classification. Based on the data set, after constructing the classification model using the kNN, SVM, and NN models, each model was compared through an error matrix. As a result of the evaluation, the accuracy of kNN was 0.967 area under curve(AUC) was 0.993, and the accuracy of SVM was 0.992 AUC was 1.000. The accuracy of NN was 0.992 and AUC was 0.999, which was slightly lower in kNN, but all three models recorded high accuracy and AUC. In this study, right-handed PA, Obl, Lat, Fan lat images were classified and predicted using the machine learning classification models, kNN, SVM, and NN models. The prediction showed that SVM and NN were the same at 0.992, and AUC was similar at 1.000 and 0.999, indicating that both models showed high predictive power and were applicable to educational simulators.

Diagnosis of Location and Size of Lesions using Chest X-ray Image (X-선 영상을 이용한 암의 위치 및 크기 진단)

  • Jung-Min, Son;Byung-Ju, Ahn
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.167-173
    • /
    • 2023
  • X-ray general radiography is the simplest and most important one to get a lot of information. Nevertheless, current x-ray general radiography does not observation in-depth observation. Information about the anatomy of the human body and changes in disease in x-ray general radiography can be obtained but it is difficult to determine the size and shape of the actual lesion due to the disadvantage of expanding the image. In this study, PA and LAT images were acquired and cancer magnification was calculated in the images by measuring the distance of cancer samples. By adjusting the magnification the actual cancer length and thickness were measured and compared with the CT image and the actual cancer sample size. After the PA and LAT images of the inserted 6.0 mm cancer sample were obtained and the magnification was corrected, the length was 5.9 mm and the thickness was 6.1 mm. This value was measured similarly to the actual. The problem of obtaining the magnification that needs to know the actual length from the detector to the cancer sample was secured by obtaining the magnification through PA and LAT images and it is possible to accurately measure the cancer sample size. X-ray general radiography may provide useful information in situations where CT imaging is difficult.

Evaluation of Usability Both Oblique Verification for Inserted Fiducial Marker of Prostate Cancer Patients (Fiducial Marker가 삽입된 전립선암 환자를 대상으로 한 양사방향 촬영의 유용성 평가)

  • Kim, Koon Joo;Lee, Jung Jin;Kim, Sung Gi;Lim, Hyun Sil;Kim, Wan Sun;Kang, Su Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.123-129
    • /
    • 2013
  • Purpose: The way check the movement of the fiducial marker insertion in the treatment of patients with prostate cancer. However the existing methods of fiducial marker verification process difficult to identify the specific location of the marker behind the femur and pelvic bone. So to study the evaluation of maker match with using kilo voltage (KV) X-ray by On-board imager to both oblique verification method. Materials and Methods: Five patients were selected for rectal ballooning and inserted fiducial marker. Compare the position of the fiducial marker of reference plan 2D/2D Anterior/Posterior verification method and 2D/2D both oblique verification method. So to measurement the shift score of X, Y, Z (axis) and measure exposure dose given to patients and compare matching time. Results: 2 dimensional OBI KV X-ray imaging using two-dimensional matching image are orthogonal, so locating fiducial marker matching clear and useful DRR (digital reconstruction radiography) OBI souce angle ($45^{\circ}/315^{\circ}$) matching most useful. 2D/2D both oblique verification method was able to see clearly marker behind the pelvic bone. Also matching time can be reduced accordingly. According to the method of each matching results for each patient in each treatment fraction, X, Y, and Z axis the Mean $value{\pm}SD$ (standard deviation) is X axis (AP/LAT: $0.4{\pm}1.67$, OBLIQUE: $0.4{\pm}1.82$) mm, Y axis (AP/LAT: $0.7{\pm}1.73$, OBLIQUE: $0.2{\pm}1.77$) mm, Z axis (AP/LAT: $0.8{\pm}1.94$, OBLIQUE:$1.5{\pm}2.8$) mm. In addition, the KV X-ray source dose radiation exposure given to the patient taking average when AP/LAT matching is (0.1/2.1) cGY, when $315^{\circ}/45^{\circ}$ matching is (0.27/0.26) cGY. Conclusion: In conclusion for inserted fiducial marker of prostate cancer patients 2D/2D both oblique matching method is more accurate verification than 2D/2D AP/LAT matching method. Also the matching time less than the 2D/2D AP/LAT matching method. Taken as the amount of radiation exposure to patients less than was possible. Suggest would improve the treatment quality of care patients more useful to establish a protocol such as case.

  • PDF