• 제목/요약/키워드: LASER

검색결과 14,326건 처리시간 0.034초

초점 모니터 방법을 이용한 레이져 Lithography 장치의 제작과 응용 (Construction of Laser Lithography System using Method of Monitoring the Focal Point)

  • 이도형
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 1990년도 제5회 파동 및 레이저 학술발표회 5th Conference on Waves and lasers 논문집 - 한국광학회
    • /
    • pp.222-226
    • /
    • 1990
  • This paper represents the construction of laser beam writing system, laser lithography, using new method that guarantees convenience and accuracy in laser focusing. The X, Y translation stage using DC motors was controlled by the computer. Minimum line width of 1.6${\mu}{\textrm}{m}$ was obtained by the laser lithography system.

  • PDF

Modulating Laser를 이용한 ESPI System algorithm 개발에 관한 연구 (Research about ESPI System Algorithm Development that Use Modulating Laser)

  • 김성종;강영준;박낙규;이동환
    • 한국정밀공학회지
    • /
    • 제26권7호
    • /
    • pp.65-72
    • /
    • 2009
  • Laser interferometry is widely used as a measuring system in many fields because of its high resolution and its ability to measure a broad area in real-time all at once. In conventional laser interferometry, for example out-of-plane ESPI (Electronic Speckle Pattern Interferometry), in plane ESPI, shearography and holography, it uses PZT or other components as a phase shift instrumentation to extract 3-D deformation data, vibration mode and others. However, in most cases PZT has some disadvantages, which include nonlinear errors and limited time of use. In the present study, a new type of laser interferometry using a laser diode is proposed. Using Laser Diode Sinusoidal Phase Modulating (LD-SPM) interferometry, the phase modulation can be directly modulated by controlling the laser diode injection current thereby eliminating the need for PZT and its components. This makes the interferometry more compact. This paper reports on a new approach to the LD (Laser Diode) Modulating interferometry that involves four-frame phase shift method. This study proposes a four-frame phase mapping algorithm, which was developed to have a guaranteed application, to stabilize the system in the field and to be a user-friendly GUI. In this paper, the theory for LD wavelength modulation and sinusoidal phase modulation of LD modulating interferometry is shown. Using modulating laser and research of measurement algorithm does comparison with existent ESPI measurement algorithm. Algorithm measures using GPIB communication through most LabVIEW 8.2. GPIB communication does alteration through PC. Transformation of measurement object measures through modulating laser algorithm that develops. Comparison of algorithm of modulating laser developed newly with existent PZT algorithm compares transformation price through 3-D. Comparison of 4-frame phase mapping, unwrapping, 3-D is then introduced.

화염증 CO2 Laser를 이용한 입자의 크기 및 형상 제어 (Control of Size and Morphology of Particles Using CO2 Laser in a Flame)

  • 이동근;이선재;최만수
    • 대한기계학회논문집B
    • /
    • 제23권11호
    • /
    • pp.1379-1389
    • /
    • 1999
  • A new technique for control of size and shape of flame-made particles is Introduced. The characteristic sintering time can be controlled Independently of collision time by heating the particles with irradiation of laser because the sintering time strongly depends on temperature. A coflow oxy-hydrogen diffusion flame burner was used for $SiCl_4$ conversion to silica particle. Nanometer sized aggregates irradiated by a high power CW $CO_2$ laser beam were rapidly heated up to high temperatures and then were sintered to approach volume-equivalent spheres. The sphere collides much slower than the aggregate, which results in reduction of sizes of particles maintaining spherical shape. Light scattering of Ar ion laser and TEM observation using a local sampling device were used to confirm the above effects. When the $CO_2$ laser was irradiated at low position from the burner surface, particle generation due to gas absorption of laser beam occurred and thus scattering intensity increased with $CO_2$ laser power. At high irradiation position, scattering intensity decreased with $CO_2$ laser power and TEM image showed a clear mark of evaporation and recondensation of particles for high $CO_2$ laser power. When the laser was irradiated between the above two positions where small aggregates exist, average size of spherical particles obviously decreased to 58% of those without $CO_2$ laser irradiation with the spherical shape. Even for increased carrier gas flow rate by a factor of three, TEM photograph also revealed considerable reduction of particle size.

저출력 레이저가 마우스 모발성장에 미치는 영향 (The Effect of Low-power Laser on the Murine Hair Growth)

  • 정필상;김진왕;이정옥;이정구;오충훈;김유찬;정상운
    • Archives of Plastic Surgery
    • /
    • 제32권2호
    • /
    • pp.149-154
    • /
    • 2005
  • Low-power laser(LPL) delivers a small amount of energy without elevation of tissue temperature. LPL has been reported to have biostimulation effects including anti-inflammatory, analgesic, regenerative, immunocorrective, and vasodilative effects. However, the effect of LPL on hair growth has rarely been studied. We investigated the effect of LPL on hair growth in the mouse. After depilation of back skin of mice, we classified the mice into 4 groups: control, laser irradiated group, $MoandMore^{(R)}$ applied group, and Spella $707^{(R)}$ applied group. Laser irradiation or application of these drugs were performed on the back skin of the mice for 30 days. The results are summarized as follows. Hair growth of control was first observed at 13 days after depilation, and complete hair regrowth was observed at 25 days. Hair growth of both laser irradiation group and $MoandMore^{(R)}$ applied group was first observed at 9 days after depilation, and complete hair regrowth was observed at 20 days. Hair growth of Spella $707^{(R)}$ applied group was firstly observed at the 9 days after depilation, and complete hair regrowth was observed at the 15 days. Hair growth started at the irradiation site in the laser irradiation group, but it started at the random sites in other groups. In conclusion LPL irradiation have a stimulating effect on the hair growth in the mouse.

Effect of Laser Acupuncture on Arterial Pulse

  • Cho, Jaekyong;Kang, Dong Hwan
    • 대한의용생체공학회:의공학회지
    • /
    • 제36권5호
    • /
    • pp.191-197
    • /
    • 2015
  • Laser acupuncture is defined as the stimulation of traditional acupuncture points with low-intensity, nonthermal laser irradiation. Possible advantages in using laser acupuncture are the noninvasive, painless and low risks of infection treatment. The purpose of this study is to assess the effect of laser acupuncture on the quality and waveform of arterial pulses. Ten acupuncture points were stimulated repeatedly three times in 30 individuals by laser with emission in the near infrared spectral region (808 nm) using an out power and power density of 45 mW and $143W/cm^2$. The analysis of pulse quality and waveform was performed based on the measurement of arterial pressure of the left and right wrist, using a 3-dimensional blood pressure pulse analyzer. Excess-like pulse quality of subjects before laser acupuncture changed significantly to balanced pulse quality after 10, 20, and 30 minutes of laser acupuncture; coefficient of deficient or excess, $C_{DE}$, decreased significantly from 0.68 before acupuncture to 0.61, 0.55, and 0.55 after 10, 20, 30 minutes of laser acupuncture ($$p{\leq_-}0.006$$), respectively. Other pulse qualities, floating or sinking, slow or rapid, choppy or slippery did not change significantly by laser acupuncture (p > 0.05). Pulse waveform analysis showed that amplitude of main peak (systolic function or aortic compliance, $h_1$) of left and right artery pulse waves decreased significantly after 10, 20, and 30 minutes of laser acupuncture (p < 0.05). Other parameters, duration of one cardiac cycle (T), duration of rapid systolic ejection ($T_1$), duration of the systolic phase ($T_4$), and duration of the diastolic phase ($T_5$) of left and right artery pulses did not change significantly after laser acupuncture (p > 0.05).

레이져를 이용한 도핑 특성과 선택적 도핑 에미터 실리콘 태양전지의 제작 (Effects of Laser Doping on Selective Emitter Si Solar Cells)

  • 박성은;박효민;남정규;양정엽;이동호;민병권;김경남;박세진;이해석;김동환;강윤묵;김동섭
    • Current Photovoltaic Research
    • /
    • 제4권2호
    • /
    • pp.54-58
    • /
    • 2016
  • Laser-doped selective emitter process requires dopant source deposition, spin-on-glass, and is able to form selective emitter through SiNx layer by laser irradiation on desired locations. However, after laser doping process, the remaining dopant layer needs to be washed out. Laser-induced melting of pre-deposited impurity doping is a precise selective doping method minimizing addition of process steps. In this study, we introduce a novel scheme for fabricating highly efficient selective emitter solar cell by laser doping. During this process, laser induced damage induces front contact destabilization due to the hindrance of silver nucleation even though laser doping has a potential of commercialization with simple process concept. When the laser induced damage is effectively removed using solution etch back process, the disadvantage of laser doping was effectively removed. The devices fabricated using laser doping scheme power conversion efficiency was significantly improved about 1% abs. after removal the laser damages.

고출력 Nd:YAG UV레이저를 이용한 polyimide층과 Cu-metal층의 가공상태에 대한 실험적 고찰 (Experimental Investigation for Ablation Characteristics of Polyimide Layer and Cu-metal Layer using High Power Nd:YAG UV Laser)

  • 최경진;이용현
    • 반도체디스플레이기술학회지
    • /
    • 제8권4호
    • /
    • pp.31-36
    • /
    • 2009
  • In this paper, the laser cutting characteristics of the flexible PCB using high power Nd:YAG UV laser were investigated. A specific FPCB model was selected for the experiment. Test sheets were made, which had equal materials and layer structure to those of the outline (OL) region and the contact pad (CP) region in the FPCB. The experiment is made up of two stages. In the first stage of the experiment, the laser cutting fluence was found, which is the threshold fluence to cut the test sheets completely. The laser cutting fluence of the OL sheet is $1781.26{\sim}1970.16\;J/cm^2$ and that of the CP sheet is $2109.34{\sim}2134.34\;J/cm^2$. In the second stage, cutting performance and its qualities were analyzed by the experiment. The laser cutting performance remained almost unchanged for all laser and process parameter sets. The average cutting width (top side/bottom side) of the OL sheet was $40.45\;{\mu}m/11.52\;{\mu}m$ and that of the CP sheet was $22.14\;{\mu}m/10.93\;{\mu}m$. However, the laser cutting qualities were different according to the parameters. The adjacent region of the cutting line on the OL sheet was carbonized as the beam speed was low and the overlap coefficient was high. The surface quality around the cutting line of the CP sheet was about the same. Carbonization and debris occurred on the surface of the cutting line. As a result of the experiment, the cutting qualities were better as the overlap coefficient was made low and beam speed high. Therefore, the overlap coefficient 2 or 3 is proper for the FPCB laser cutting.

  • PDF

CO2 Laser와 Scalpel을 이용한 절개 시 돼지 방광에서의 창상치유 평가 (Comparative study of wound healing in porcine urinary bladder with CO2 laser and scalpel incisions)

  • 이재연;정성목;조성환;박창식;김명철
    • 대한수의학회지
    • /
    • 제50권3호
    • /
    • pp.247-251
    • /
    • 2010
  • This study compared the instrument performance and tissue healing of a steel scalpel with a $CO_2$ laser in an animal urinary bladder surgery model. Landrace and Yorkshire mixed breed pigs were used. Two symmetrical incisions were made in urinary bladder of each pig. One incision was made on the left side of ventral aspect on urinary bladder using a steel scalpel, while the other incision was performed on the right side using a $CO_2$ laser with an 8W output power. Each instrument was evaluated clinically for speed, ease of incision, and extent of bleeding. At 7 and 21 days after initial wounding, each wound was taken for histological observations. The scalpel was an easier instrument to use in the confines of the urinary bladder tissue, compared with the laser. However, there was no significant difference between the two groups. The amount of bleeding was less in the laser group but the time of the incisions was shorter with the scalpel. Scalpel incisions showed complete restoration of the epithelium and muscularis. On the other hand, the laser incisions showed incomplete restoration of the epithelium and muscularis. However, most of wound healing in the laser incisions was accomplished according to the time lapse. Although the scalpel produced less damage to the urinary bladder tissue and was easier to handle than the $CO_2$ laser, it did not provide hemostasis that was helpful for use on highly vascular tissue. The $CO_2$ laser provided good hemostasis, but delayed wound healing. In conclusion, the $CO_2$ laser provided better hemostasis and better surgical field than the scalpel. The $CO_2$ laser was used effectively in urinary bladder incision.

다발성 관절염 실험동물 모델에서 저출력 GaAlAs 레이저 자극의 진통효능 및 통증관련 척수내 신경세포의 활성변화에 관한 연구 (The effect of low power GaAlAs laser stimulation on anti-nociception and spinal neuronal activity related to pain sensation in the polyarthritis of rats)

  • 장문경;최영덕;박봉순
    • 대한물리치료과학회지
    • /
    • 제10권1호
    • /
    • pp.180-189
    • /
    • 2003
  • The experiments were designated to evaluate the anti-nociceptive effect of low power laser stimulation on acupoint or non-acupoint using arthrogenic solution induced poly arthritis animal model. Evaluation of potential antinociceptive effect of low power laser on arthritis has employed measurements of the foot bending test, the development of either thermal or mechanical hyperalgesia following the arthritis induction. The analysis of thermal hyperalgesia includes Hargreaves's method. Randall-Sellitto test was utilized for evaluating mechanical hyperalgesia. In addition, the antinociceptive effect of low power laser stimulation on arthritis induced spinal Fos expression was analyzed using a computerized image analysis system. The results were summerized as follows: 1. In laser stimulation on acupoint treated animal, laser stimulation dramatically inhibited the development of pain in foot bending test as compared to those of non acupoint treated animal group and non treated animal group. 2. The threshold of thermal stimulation was significantly increased by low power laser stimulation on acupoint as compared to that of non treated control group. 3. Laser stimulation on acupoint dramatically attenuated the development of mechanical hyperalgesia as compared to that of non treated group. 4. Low power laser stimulation on acupoint significantly suppressed arthritis induced Fos expression in the lumbar spinal cord at 3 week post arthritis induction. In conclusion, the results of the present study demonstrated that low power laser stimulation on acupoint has potent anti-nociceptive effect on arthritis. Additional supporting data for an antinociceptive effect of laser stimulation was obtained using Fos immunohistochemical analysis on spinal cord section. Those data indicated that laser stimulation induced antinociception was mediated by suppression of spinal neuron activity in pain sensation.

  • PDF