• Title/Summary/Keyword: LAMP2

Search Result 1,125, Processing Time 0.029 seconds

A Study of High Efficiency Electrodeless lamp Properties (고효율 신광원 시스템의 특성에 관한 연구)

  • Kim, H.S.;Lee, S.H.;Shin, S.W.;Lim, J.M.;Huh, S.K.;Hwang, M.K.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1717-1720
    • /
    • 2002
  • Electrodeless discharge lamps have been objects of interest and research for several decades, mainly because of their potential for extremely long life, high lamp efficacies and smaller than standard fluorescent lamps size. A series of measurements and observations concerning variables has yielded optical and electrical characteristics for electrodeless discharge lamp like incandescent lamp and circular lamp feature. Last experiment were carried out to determine the lamp temperature at several surface points during operation. Light output levels in excess over 60,000 cd/$m^2$ have been measured in electrodeless discharge lamp for a general of conditions. At lamp surface temperatures have been measured over $80^{\circ}C$, and starting current have been measured over ${\sim}A$.

  • PDF

Study on the Performance of Infrared Thermal Imaging Light Source for Detection of Impact Defects in CFRP Composite Sandwich Panels

  • Park, Hee-Sang;Choi, Man-Yong;Kwon, Koo-Ahn;Park, Jeong-Hak;Choi, Won-Jae;Jung, Hyun-Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.37 no.2
    • /
    • pp.91-98
    • /
    • 2017
  • Recently, composite materials have been mainly used in the main wings, ailerons, and fuselages of aircraft and rotor blades of helicopters. Composite materials used in rapid moving structures are subject to impact by hail, lightning, and bird strike. Such an impact can destroy fiber tissues in the composite materials as well as deform the composite materials, resulting in various problems such as weakened rigidity of the composite structure and penetration of water into tiny cracks. In this study, experiments were conducted using a 2 kW halogen lamp which is most frequently used as a light source, a 2 kW near-infrared lamp, which is used for heating to a high temperature, and a 6 kW xenon flash lamp which emits a large amount of energy for a moment. CFRP composite sandwich panels using Nomex honeycomb core were used as the specimens. Experiments were carried out under impact damages of 1, 4 and 8 J. It was found that the detection of defects was fast when the xenon flash lamp was used. The detection of damaged regions was excellent when the halogen lamp was used. Furthermore, the near-infrared lamp is an effective technology for showing the surface of a test object.

An Experimental Study on the a Light Device which Adopt Safety Ultra Constant Dischange Lamp (초정압 방전램프(UCD)를 적용한 안전 조명 장치에 관한 연구)

  • Jeong, Poong-Gi;Kim, Young-Chul
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2010.11a
    • /
    • pp.63-80
    • /
    • 2010
  • This paper describes the development of various lighting equipment adapting Ultra Constant Discharge Lamp that has newly been on commercial supply in the market. Meeting the required conditions of lighting equipment, various types of UCD Lamp equipment with excellent performances could be successfully developed. In order to provide a guideline for the economical lighting product selection, the analyzed data comparison between Hi-pressure Sodium Lamp which has been the most popular lamp for street lighting and UCD Lamp is provided. The conclusions of the study are made as follows; (1) The performance measurement result of UCD Lamp shows excellent Luminous Efficacy as 108Lm/W, daylight-like Color Rendering Index as 90Ra, and the best operating temperature range as $-50^{\circ}C{\sim}+85^{\circ}C$. Comparing to the Hi-pressure Sodium Lamp, UCD could be evaluated as much superior products. (2) In an assembled status with the lighting fixture (Type STB형-60W), UCD Lamp was tested OK for one hour duration at the temperature range form $-50^{\circ}C$ to $+85^{\circ}C$ and the humidity of 98%. The operation at the extremely low temperature can be an excellent feature to enable the export to the cold temperature regions such as Northern Europe and Russia and the specific applications for defense systems and special industry. (3) As UCD Lamp is a genuine Korea made product following Energy-saving and Eco-friendly policy, it should be appreciated as one of the best $CO^2$ reduction Green product.

  • PDF

Predicting of Ignition Time and Critical Distance for Ignition of Douglas fir by Radiant Heat of Incandescent Lamp (백열전구 복사열에 의한 미송판의 발화 임계거리 및 발화시간 예측)

  • Lee, Heung-Su;Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.2
    • /
    • pp.18-25
    • /
    • 2016
  • The incandescent lamp is an electric light fixture with a tungsten filament heated to a high temperature, by passing an electric current through it, until it glows with visible light. The hot filament is protected from oxidation with a glass bulb that is filled with inert gas. The incandescent lamp has fire risk when combustible materials are close to its glass bulb. Because its lamp has the property which converts 90~95 percents of the electric power to heat energy. 2015 national fire statistics show that fires caused by lighting fixtures were 652 cases, and incandescent lamps(44 cases) and halogen lamps(53 cases) accounted for 15 percents in those of high heating light fixtures. Since incandescent lamp fires account for about 45 percents in the high heating light fixture, we could not overlook the fire risks by the incandescent lamp. Although many studies related with those have been conducted, incandescent lamp fires are continuously occurred. This study was carried out to study the fire risk of ignition of wood due to radiant heat of incandescent lamp. Radiant heat flux of the incandescent lamp was predicted by applying point source model, and critical distance for ignition of wood was calculated by applying integral model. The results from this study could applied to fire prevention activities related to light bulb, and it could be used in fire cause investigations related to radiant heat of incandescent lamp.

Manufacturing and Characteristics of the Electrodeless UV Lamp for Disinfection of the Sewage Effluent (하수 방류수 살균소독을 위한 무전극 UV 램프의 제조 및 특성)

  • Shin, Dong Ho;Lee, Yong Taek
    • Applied Chemistry for Engineering
    • /
    • v.16 no.4
    • /
    • pp.570-575
    • /
    • 2005
  • In this study, we have manufactured electrodeless ultraviolet lamp which has a long life and a high degree of efficiency than the existing electrode UV lamp used in sewage effluent sterilization disinfection. First, we investigated change of UV intensity and temperature of lamp by activation materials. The best results for the dose response experiments were 250 minutes stabilizing to UV intensity of $300{\mu}W/cm^2$ and surface temperature $200{\sim}250^{\circ}C$ in Hg/Ind's weight ratio 95/5. When electrodeless UV lamp emits light for prolonged hours, surface temperature of lamp increases. therefore, temperature change is studied using a duplex lamp for cooling in actual sewerage process. Also, manufactured electrodeless UV lamp showed sterilization efficiency of more than 99.9% as result that experiment manufactured electrodeless UV lamp by E-coli. for sterilization disinfection of sewage effluent.

An Experimental Study on the a Light Device which Adopt Safety Ultra Constant Dischange Lamp (초정압 방전램프(UCD)를 적용한 안전조명 장치에 관한 연구)

  • Jeong, Poong-Gi;Kim, Young-Chul
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.4
    • /
    • pp.41-51
    • /
    • 2010
  • This paper describes the development of various lighting equipment adapting Ultra Constant Discharge Lamp that has newly been on commercial supply in the market. Meeting the required conditions of lighting equipment, various types of UCD Lamp equipment with excellent performances could be successfully developed. In order to provide a guideline for the economical lighting product selection, the analyzed data comparison between Hi-pressure Sodium Lamp which has been the most popular lamp for street lighting and UCD Lamp is provided. The conclusions of the study are made as follows; (1) The performance measurement result of UCD Lamp shows excellent Luminous Efficacy as 108Lm/W, daylight-like Color Rendering Index as 90Ra, and the best operating temperature range as $-50^{\circ}C{\sim}+85^{\circ}C$. Comparing to the Hi-pressure Sodium Lamp, UCD could be evaluated as much superior products. (2) In an assembled status with the lighting fixture (Type STB형-60W), UCD Lamp was tested OK for one hour duration at the temperature range form $-50^{\circ}C$ to $+85^{\circ}C$ and the humidity of 98%. The operation at the extremely low temperature can be an excellent feature to enable the export to the cold temperature regions such as Northern Europe and Russia and the specific applications for defense systems and special industry. (3) As UCD Lamp is a genuine Korea made product following Energy-saving and Eco-friendly policy, it should be appreciated as one of the best $CO^2$ reduction Green product.

Development of a Rapid Detection Method for Pectobacterium carotovorum subsp. carotovorum Using the Loop-Mediated Isothermal Amplification (LAMP) (Loop-Mediated Isothermal Amplification (LAMP)법을 이용한 Pectobacterium carotovorum subsp. carotovorum의 신속 진단법 개발)

  • Kim, Jeong-Gu;No, Ji-Na;Park, Dong-Suk;Yoon, Byoung-Su
    • Korean Journal of Microbiology
    • /
    • v.47 no.2
    • /
    • pp.103-109
    • /
    • 2011
  • Pectobacterium carotovorum subsp. carotovorum is the causative agent of soft rot in crops such as potato and cabbages. Loop-mediated isothermal amplification (LAMP) is a simple DNA amplification method, as well as isothermal PCR technique. In this study, a new method for the rapid detection of Pectobacterium carotovorum subsp. carotovorum was developed using LAMP that named PCC-LAMP. Based on lytic murein transglycolase gene of Pectobacterium carotovorum subsp. carotovorum, a set of four primers for LAMP was designed. The optimal PCC-LAMP reaction temperature was established at $61^{\circ}C$. Under standard conditions, PCC-LAMP amplified $1{\times}10^3$ copies of clone PCC-pBX437 per reaction. Further, this method can also assay directly by SYBR Green I without electrophoresis. Amplification was not detected for five other bacterial species. In conclusion, PCC-LAMP may be a useful method for the detection Pectobacterium carotovorum subsp. carotovorum in the field.

Development of Multi LED type Door Status Indication Lamp for rolling stock (Multi LED를 이용한 철도차량용 Door Status Indication Lamp)

  • Seo, Bum-Won;Choi, Jae-Sung;Kim, Dong-Il
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1668-1674
    • /
    • 2011
  • Door Inside Lamp of railway rolling stock is installed on interior of the side doors and illuminated at door opening and closing, isolation and fault. So drivers or passengers can notice the door status visually. In the past, a single color or Bi-color LED Lamps have been using and one ~ multiple lamp was used to implement the feature according to client's requirements. (Example: Total of between 2 and 4 lamps are required for the Warning / Emergency operation / Isolation / Fault.) However these design is not easy to apply if there is the mounting space restrictions and the problems such as rising costs can be caused. In addition, it has vulnerability from point of view aesthetic aspects. Therefore the lamp type has been required that has small size and number of colors in order to resolve these problems. Recently multi LED type door status indication lamp have been developed that can meet the requirements and this lamp has been applied in many railway projects. In this study, I'll introduce the general characteristics and mechanical & electrical characteristics of multi LED type door status indication lamp to help development of this kinds of lamp.

  • PDF

Development of Multi LED type Door Status Indication Lamp for rolling stock (Multi LED를 이용한 철도차량용 Door Status Indication Lamp)

  • Seo, Bum-Won;Choi, Jae-Sung;Kim, Dong-Il
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1466-1472
    • /
    • 2011
  • Door Inside Lamp of railway rolling stock is installed on interior of the side doors and illuminated at door opening and closing, isolation and fault. So drivers or passengers can notice the door status visually. In the past, a single color or Bi-color LED Lamps have been using and one ~ multiple lamp was used to implement the feature according to client's requirements. (Example: Total of between 2 and 4 lamps are required for the Warning / Emergency operation / Isolation / Fault.) However these design is not easy to apply if there is the mounting space restrictions and the problems such as rising costs can be caused. In addition, it has vulnerability from point of view aesthetic aspects. Therefore the lamp type has been required that has small size and number of colors in order to resolve these problems. Recently multi LED type door status indication lamp have been developed that can meet the requirements and this lamp has been applied in many railway projects. In this study, I'll introduce the general characteristics and mechanical & electrical characteristics of multi LED type door status indication lamp to help development of this kinds of lamp.

  • PDF

Interior Light Environment and Building Energy Performance Analysis of LED Lamp Installed in Office Building (LED램프를 적용한 사무소 건물의 실내조명환경 및 에너지 성능분석)

  • Kim, Byoung-Soo;Hong, Won-Pyo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.5
    • /
    • pp.77-85
    • /
    • 2010
  • In this paper, A new integrated energy simulation results of LED lamp are presented to use it effectively in the office buildings. Generally LED lamp has many advantages in comparison with a general lamp such as long life and no pollution problem like the mercury. It also is excellent in color rendering and small consumption electric power. However LED lamp has some disadvantages to compare to general fluorescent lamp. It is small light flux about 50[%] and narrow light distribution than fluorescent lamp. Therefore, to apply LED lamp in an office building, the illuminance distribution with an environment analysis and cooling, heating and light energy has to be analyzed. The purpose of this study is to analyze light environment, light, cooling and heating energy simulation in office building.