• Title/Summary/Keyword: LAMP

Search Result 2,698, Processing Time 0.027 seconds

A Thermal Flow Analysis for an Optimal shape of Solar Lamp Bank (최적의 램프뱅크형태를 결정하기 위한 열유동 해석)

  • Baek, Sang-Hwa
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.4
    • /
    • pp.82-89
    • /
    • 2012
  • This study is on the thermal flow analysis to select an optimal shape of solar lamp bank. Solar Lamp bank is designed by the lamp bank design program based on point light source theory. The reliability of the program for lamp bank design is verified through irradiance variation experiments of a kind of lamp according to horizontal distance. Solar lamp bank facilitates heat distribution and satisfies the irradiance in the three wave length which test guidelines require. Among the 4 kinds of lamp bank, since lamp bank type D satisfies uniformity ${\pm}10%$ and also doesn't exceed total irradiance 1,232 $W/m^2$, type D is finally selected.

Comparison of Radiation Characteristics and Radiant Quantities per unit Electrical Power between High Luminance Light Emitting Diode and Fishing Lamp light Source (고휘도 발광다이오우드와 집어등 광원의 방사특성 및 단위 전력당 방사량 비교)

  • Choi, Sok-Jin
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.41 no.6
    • /
    • pp.511-517
    • /
    • 2008
  • The radiation characteristics and economic efficiency of high - luminance light - emitting diodes (LEDs), a metal halide lamp, and a halogen lamp were studied to evaluate their potential as an energy-saving light source for fishing lamps. The wavelengths at which irradiance was maximum were 709, 613, 473, 501, 525, 465, 578, and 973 nm for red, orange, blue, peacock blue, green, and white LEDs, the metal halide lamp, and the halogen lamp, respectively. If the irradiance characteristics at 300-1,100 nm wavelengths are set as 100%, the irradiance rates at 381-780 nm were 99-78%, 82%, and 24% for the LEDs, metal halide lamp, and halogen lamp, respectively. The economic efficiency was superior in the order metal halide lamp, halogen lamp, peacock blue LED, and blue LED at 381-780 nm and metal halide lamp, peacock blue LED, blue LED, and halogen lamp at 480-520 nm. Based on the radiation characteristics and economic efficiency evaluated at 480-520 nm, the blue and peacock blue LED light sources can be used as energy-saving light sources for fishing lamps.

LAMP-3 (Lysosome-Associated Membrane Protein 3) Promotes the Intracellular Proliferation of Salmonella typhimurium

  • Lee, Eun-Ju;Park, Kwan-Sik;Jeon, In-Sook;Cho, Jae-Woon;Lee, Sang-Jeon;Choy, Hyun E.;Song, Ki-Duk;Lee, Hak-Kyo;Choi, Joong-Kook
    • Molecules and Cells
    • /
    • v.39 no.7
    • /
    • pp.566-572
    • /
    • 2016
  • Lysosomes are cellular organelles containing diverse classes of catabolic enzymes that are implicated in diverse cellular processes including phagocytosis, autophagy, lipid transport, and aging. Lysosome-associated membrane proteins (LAMP-1 and LAMP-2) are major glycoproteins important for maintaining lysosomal integrity, pH, and catabolism. LAMP-1 and LAMP-2 are constitutively expressed in Salmonella-infected cells and are recruited to Salmonella-containing vacuoles (SCVs) as well as Salmonella- induced filaments (Sifs) that promote the survival and proliferation of the Salmonella. LAMP-3, also known as DC-LAMP/CD208, is a member of the LAMP family of proteins, but its role during Salmonella infection remains unclear. DNA microarray analysis identified LAMP-3 as one of the genes responding to LPS stimulation in THP-1 macrophage cells. Subsequent analyses reveal that LPS and Salmonella induced the expression of LAMP-3 at both the transcriptional and translational levels. Confocal Super resolution N-SIM imaging revealed that LAMP-3, like LAMP-2, shifts its localization from the cell surface to alongside Salmonella. Knockdown of LAMP-3 by specific siRNAs decreased the number of Salmonella recovered from the infected cells. Therefore, we conclude that LAMP-3 is induced by Salmonella infection and recruited to the Salmonella pathogen for intracellular proliferation.

Comparative Study of Effects of Illumination with Xenon or Sulfur Lamp on Development of Wheat Plants

  • Chen, Qilin;Yu, Xinjian;Chen, Jinxing;Liu, Yuequn;Weng, Jun;Xu, Chunhe
    • Journal of Photoscience
    • /
    • v.9 no.2
    • /
    • pp.394-396
    • /
    • 2002
  • The emission of microwave sulfur lamp is mainly composed of visible light. This lamp producing little infrared radiation, has high light efficiency, long lifespan and less power consumption. In comparison with xenon lamp, growing under sulfur lamp apparently postponed jointing, increased the number of tillers, accelerated root growth of wheat. Relatively, xenon lamp evidently promoted heading and grain maturation. The development characteristics of wheat plant under sulfur lamp were more similar with that in natural condition.

  • PDF

Magnetic field effect on the positive column of fluorescent lamp (형광등 Positive column에 대한 자장인가 효과)

  • 지철근;김창종
    • 전기의세계
    • /
    • v.31 no.3
    • /
    • pp.197-203
    • /
    • 1982
  • The effects on the characteristics of 20-W fluorescent lamp were studied when applying magnetic field to its positive column. First, when the direction of the magnetic field is axial, i.e., along the lamp, if the magnitude of the field is stronger than the critical field, lamp voltage is increased, lamp current decreased, luminous flux increased, starting voltage decreased, as increasing the applied magnetic field. At the magnetic flux density is 130 gauss, luminous flux is increased to about 6 percents and starting voltage is increased to about 45 percents. Second, when the direction of the magnetic field is transverse to the lamp axis, as increasing the applied magnetic field, lamp voltage is increased, lamp current decreased, luminous flux increased and starting voltage is nearly constant, but the rates of increase or decrease of this case is different from those of the first. At the magnetic flux density is 300 gauss, luminous flux is increased about 45 percents. In both cases, electric power dissipated by lamps is the same as that of the lamp which magnetic field is not applied to.

  • PDF

A Study on LED Fluorescent Lamp applying Circuit Driven Method to Tubular LED Lamp Converter (직관형 LED램프 컨버터에 회로구동방식을 적용한 LED 형광등 연구)

  • Yang, Byongmoon;Cha, Jaesang
    • Journal of Satellite, Information and Communications
    • /
    • v.10 no.1
    • /
    • pp.77-82
    • /
    • 2015
  • In this paper, we perform a study on LED Fluorescent Lamp applying Circuit Driven Method to Tubular LED Lamp Converter. The energy efficiency of LED fluorescent lamp converter requires exceptional protection circuit design, circuit design and structure, because it can not take advantage of Heat-sink structure of the heightened degree Reflector for Fluorescent Lamp. In this paper, we performed a study on LED fluorescent lamp applying circuit driven method to tubular LED lamp converter, Also, we designs LED lamp and converter which can supply DC power common commercial power source.

A Growth Responses of Indoor Ground Cover Plants according to a Light Source of Aritificial Light (인공광의 광원에 따른 실내 지피식물의 생육반응)

  • 방광자;박혜경;최경옥
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.27 no.5
    • /
    • pp.114-119
    • /
    • 2000
  • This study was carried out to obtain fundamental information of growth response of ground cover plants under artificial light quality at indoor. Aglaonema 'Silver Queen', Hedera helix L., Hoya carnosa 'Tricolor' and Saintpaulia ionantha 'Frances' were examined under a 400lux light intensity consisted of Mercury lamp, True-lite lamp, incandescent lamp, dark-room and sunlight indoor condition. A data analysis were performed by GLM, Duncan's multiple range test and mean score with SAS program. Results of experiments are as follows; 1. A plant growth status was better showed under the True-lite lamp than sunlight. 2. A Saintpaulia ionantha flower color was responded in the first place, the deep pinkish red color of Saintpaulia ionantha flower was obtained under Mercury lamp and "True-lite lamp", "sunlight", and incandescent lamp were follow. Flower numbers of Saintpaulia ionantha after 60 days tended to decrease under every artificial light quality. 3. Leaf length and leaf width were increased under True-lite lamp, but most of plants was not significantly affected by artificial light quality. 4. A stem length of Hedera helix was increased the highest rank under sunlight also, one of artificial light, the highest increase rank was showed under incandescent lamp. 5. Chlorophyll content was highly increased under Mercury lamp, but was responded poor under incandescent lamp.

  • PDF

A Study on the Plant Cultivation by comparing Ultra Constant Discharge (UCD) Lamp lighting and Hi-Pressure Sodium Lamp lighting (초정압방전램프(UCD)와 나트륨램프를 적용한 식물재배에 관한 연구)

  • JEONG, P.G.;KIM, Y.C.;YANG, H.S.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.1
    • /
    • pp.31-40
    • /
    • 2011
  • This study was conducted to research how UCD(Ultra Constant Discharge) lamp lighting affects plant cultivation. To get the results within a short time, lettuce seedling was selected as a plant and nutrient hydroponic beds were used in a dark room for 100% artificial lighting. Two beds were installed for same distance lighting condition with UCD lamp and Hi-pressure Sodium lamp each and another two beds were installed for same light intensity condition with each type of lamp. After 15 days of cultivation, for both conditions, the yields under UCD lamp were weighed more than that under Hi-pressure Sodium lamp. The result can be analyzed that the spectrum of UCD lamp having near sunlight characteristic is much superior to that of Hi-pressure Sodium lamp having a line spectrum characteristic on yellow and red wavelengths for plant cultivation.

Comparative Evaluation of Loop-Mediated Isothermal Amplification (LAMP) and Conventional PCR for Detection of Shiga-Toxin-Producing Escherichia coli (STEC) in Various Food Products

  • Hyejin Jang;Yong Sun Cho
    • Journal of Food Hygiene and Safety
    • /
    • v.38 no.5
    • /
    • pp.347-355
    • /
    • 2023
  • In this study, polymerase chain reaction (PCR) and loop-mediated isothermal amplification (LAMP) were compared in terms of their ability to detect shiga-toxin-producing Escherichia coli (STEC). Various foods were artificially inoculated with STEC to evaluate the limit of detection (LOD), limit of quantification (LOQ), sensitivity, specificity, and efficiency of PCR and LAMP. The LODs were ≤104 and ≤103 CFU/mL for PCR and LAMP, respectively. The LOQs did not differ between PCR and LAMP. However, of the four considered food types, the sensitivities differed by a maximum of 11.1% for seasoned meat and by a minimum of 8.1% for ground beef. LAMP had higher sensitivity than that of PCR and 100% specificity for all four food types. Therefore, LAMP is a reliable molecular method for detecting STEC as comparable to PCR assay, and its specificity and sensitivity are superior to those of PCR, depending on the food type.

Development of a Rapid Detection Method for Pectobacterium carotovorum subsp. carotovorum Using the Loop-Mediated Isothermal Amplification (LAMP) (Loop-Mediated Isothermal Amplification (LAMP)법을 이용한 Pectobacterium carotovorum subsp. carotovorum의 신속 진단법 개발)

  • Kim, Jeong-Gu;No, Ji-Na;Park, Dong-Suk;Yoon, Byoung-Su
    • Korean Journal of Microbiology
    • /
    • v.47 no.2
    • /
    • pp.103-109
    • /
    • 2011
  • Pectobacterium carotovorum subsp. carotovorum is the causative agent of soft rot in crops such as potato and cabbages. Loop-mediated isothermal amplification (LAMP) is a simple DNA amplification method, as well as isothermal PCR technique. In this study, a new method for the rapid detection of Pectobacterium carotovorum subsp. carotovorum was developed using LAMP that named PCC-LAMP. Based on lytic murein transglycolase gene of Pectobacterium carotovorum subsp. carotovorum, a set of four primers for LAMP was designed. The optimal PCC-LAMP reaction temperature was established at $61^{\circ}C$. Under standard conditions, PCC-LAMP amplified $1{\times}10^3$ copies of clone PCC-pBX437 per reaction. Further, this method can also assay directly by SYBR Green I without electrophoresis. Amplification was not detected for five other bacterial species. In conclusion, PCC-LAMP may be a useful method for the detection Pectobacterium carotovorum subsp. carotovorum in the field.