• Title/Summary/Keyword: LAMP

Search Result 2,688, Processing Time 0.028 seconds

A Study on Geosmin Removal of Algae Byproducts by Ozonation and Photocatalysis (오존과 광촉매를 이용한 조류 부산물중 Geosmin 제거에 관한 연구)

  • 김은호;성낙창;최용락
    • Journal of Life Science
    • /
    • v.9 no.5
    • /
    • pp.581-589
    • /
    • 1999
  • This study was carried out to compare ozonation with photocatalysis degradation for removal Geosmin of algae byproduct. The change of pH was decresed from 7.02 to 2.8 after contact time 480 minute for ozonation. In case of UV-germicidal lamp, pH was very quickly increased from 7.02 to 7.5, but Halogen lamp did very slowly change pH. Geosmin degradation ratio was as following, UV-germicidal lamp/TiO2(100mg/L) O3>UV-germicidal lamp/TiO2(50mg/L)>UV-germicidal lamp(10W)>halogen lamp(50W). Instead of TiO2 suspension solution, Geosmin degradation ratio was very low using hollow bead and pellet as coated TiO2. As a result of identifing byproducts, ozonation generated three species of aldehyde such as 3-Heptanone and three species of alcohol such as Heptanal, but photocatalysis formed 1, 14-Tetradecanediol infinitesimally.

  • PDF

Design and Implementation of a 3 DOF Robotic Lamp (3자유도 조명로봇 설계 및 구현)

  • Lee, Yun-Seok;Seo, Jong-Tae;Kim, Whee-Kuk;Yi, Byung-Ju
    • The Journal of Korea Robotics Society
    • /
    • v.5 no.3
    • /
    • pp.216-223
    • /
    • 2010
  • Most lamp units at ceilings, walls, and streets are static and no automatic motion capabilities are available at all to adjust lamp tilting angles and its zooming position. This paper proposes a new robotic lamp that creates three degrees of freedom (DOF) motion by using a spherical-type parallel mechanism with a unique forward kinematic position. In the robotic lamp, three motors are placed at the base frame to control two tilting angles and one zoom in-and-out motion for a localized light. The kinematic model of this device is derived and the proto type has been developed. The performance of this device was verified through experiment.

Time-division Visible Light Communication Using LED Lamp Light

  • Lee, Seong-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.145-150
    • /
    • 2015
  • We introduce a new method of time-division visible light communication (VLC) using LED lamp light for the generation of synchronizing pulses. The LED lamp, driven by an AC 220-V power line, radiates light that has a 120-Hz frequency component. The pulse generator in each VLC system receives the LED lamp light and generates the synchronizing pulses that are required for time-division transmission of multiple VLC channels. The pulse period is subdivided into several time slots for VLC channels. In experiments, 120-Hz synchronizing pulses were generated using LED lamp light, and three VLC channels were transmitted independently without interfering with each other in a condition where the VLC signals overlapped in space. This configuration is useful in constructing multiple wireless sensor networks that are safe and without interference in locations where LED lamps are used for illumination.

A Study of Air Freshing by UV lamp and TiO2 Catalyst (UV lamp와 TiO2 광촉매를 이용한 공기 정화에 관한 연구)

  • Lee, Gun-Duck;Woo, In-Sung;Hwang, Myung-Hwan;Lee, In-Buk;Kim, Kwan-Jung;Park, Hwa-Young
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2011.04a
    • /
    • pp.205-227
    • /
    • 2011
  • On this study, the test for air-purification was executed as using the UV lamp and the UV lamp on which the TiO2 catalyst had been deposited with glass fiber in the reactor chamber. It aimed at the basic data of air-purifier as assessing the features of removing abilities for various contaminants including CH3COOH, NH3, NO, and SO2 as varying the number of TiO2 coating, the wave of UV lamp, and the amount of additive CaO as variables.

  • PDF

Comparative Study of the Preheating Methods to Extend the Life of the Fluorescent Lamp (형광등의 수명 연장을 위한 예열 방식의 비교 연구)

  • Han, Jae-Hyun;Jo, Gye-Huyn;Park, Chong-Yeun
    • Journal of Industrial Technology
    • /
    • v.23 no.A
    • /
    • pp.29-33
    • /
    • 2003
  • This paper proposed methods of filament preheating to extend a fluorescent lamp life. The ballast for the fluorescent lamp can be classified into two main groups magnetics and electronics. The electronic ballast is lighter and smaller than the magnetic ballast and it can dim up and down. There are two ways to start the fluorescent lamp in the electronic ballast: rapid start and instant start. Also there are two methods of the driving inverter self excited oscillation and force excited oscillation. The rapid starting is different from the instant starting in that the rapid start is preheating the filament before the steady state. If there is a preheating process before the lamp ignition, the life of the fluorescent lamp can be increased. This paper presented the preheating methods for self excited oscillating system and force excited oscillating system.

  • PDF

A Study on the Lamp Type Ozonizer (Lamp 형 오존발생기에 관한 연구)

  • 강천수;송현직;김상구;박원주;이광식;이동인
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1995.10a
    • /
    • pp.25-28
    • /
    • 1995
  • This paper describes ozone concenteration(O3con) and ozone generation(O3g) of lamp type ozo-nizer(O-Lamp)which be performed a role of lighting source and ozonizer. O=Lamp is consist of two low pressure mercury lamps. The important conclus-ions obtained from this paper are as follows, The more quality of supplied gas(Q) decrease, the higher O3con rise, The more quality of supplied gas(Q) increase, the higher O3g some rise. The Escherichia coli is reacted on ozone can be sterilized above 99[%]. Also, O-Lamp can confirmed possibility of appli-cation as lighting-source.

  • PDF

Discharge Characteristics of flat fluorescent lamp with printable MgO layer (프린팅 법으로 MgO레이어를 적용한 평면 형광 램프의 방전특성)

  • Kim, Seon-Ho;Ahn, Sung-Il;Lee, S.E.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.443-443
    • /
    • 2008
  • 차세대 LCD back light 시스템으로 Xe plasma plat lamp를 주목하고 있으나 자외선 여기 효율이 떨어져 램프의 휘도 및 광 효율이 낮은 단점을 가지고 있어 이에 따른 개선이 요구되고 있다. MgO는 AC-PDP에서 방전전압의 저하, 방전의 안정성, 동작마진과 같은 특성에 영향을 미치고 있기에 이번 연구 에서는 졸겔법으로 제작한 MgO를 프린팅 방법으로 flat fluorescent lamp에 적용하였다. 실험시 사용한 flat fluorescent lamp의 경우 ITO 전극과 MgO layer 그리고 형광체층을 가진 두 장의 유리판 사이에 Ne-Xe기체를 채운 단순한 구조로 제작하였다. 실험은 압력과 방전거리에 따른 특성을 살펴보았으며, 그 결과 MgO layer 채용한 경우 방전 전압의 감소 및 static margin의 증가를 알 수 있었다.

  • PDF

The verification of Luminous flux of Reference illuminant for New light source by the calculated correction factor (보정계수 산출에 의한 신광원용 표준램프 광속의 검증)

  • Hwang, Myung-Keun;Shin, Sang-Wuk;Yi, Chin-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.2
    • /
    • pp.369-372
    • /
    • 2009
  • When measuring the luminous flux of a light source at the integrating sphere photometer, it can know the luminous flux to compare the standard lamp with the specimen lamp at the same location. But in case of PLS(plasma lighting system, microwave discharged lamp), that two lamps are cannot be the same location. If the reference illuminant and specimen lamp are cannot measure identical location, we should measure the variation of the luminous flux. For the outcome we can turn out a correction factor to revise and reflect it. But the better way is calibrate the specimen lamp locate the identical location of reference illuminant measured. In this thesis, we've test to find the correction factor for consider that change the measuring location. And it turns out the correction factor. From this, it presents the result to make a select for the reference illuminant which is against the illuminant type for newly produce.

Electronic Ballast for HPS Lamps with Intrinsic Power Regulation over Lamp Life

  • Dehghani, Majid;Saghaiannejad, Seid Mortaza;Karshenas, Hamid Reza
    • Journal of Power Electronics
    • /
    • v.9 no.4
    • /
    • pp.526-534
    • /
    • 2009
  • This paper introduces the electronic ballast for high pressure sodium (HPS) lamps which provides power regulation during the whole lamp life without using a closed-loop power control system, in spite of large variations of lamp characteristics resulting from lamp aging. The structure of the electronic ballast and the parameters of HPS lamps are described. A mathematical model for the ballast is developed and used for the design and analysis of the ballast. A design procedure is presented to design the ballast which provides intrinsic power regulation over the whole lamp life. To improve the technical specifications of the ballast, the practical and standard constraints are considered in the design. According to the design procedure, an electronic ballast for 250-W HPS lamps is designed. All theoretical analyses are verified with the help of a semi-industrial experimental setup. The results validate that the designed ballast provides power regulation during the whole lamp life.

Igniter design methods of the ballasts for Ceramic Metal Halide lamp (세라믹 메탈할라이드 램프용 안정기의 점화기 설계 방법)

  • Park, Chong-Yeun;Choe, Wang-Seop
    • Journal of Industrial Technology
    • /
    • v.30 no.A
    • /
    • pp.75-81
    • /
    • 2010
  • We described the operating principles of two different type of igniters for lightning of Ceramic Metal Halide Lamp(CMHL) and also provide some useful comparisons. One is for magnetic ballast, the other one is for electronic ballast which operates lamp by low-frequency square-waveform. Ignition voltage of lamp depends on the structure of igniter, such as the length and electrical characteristics of cable, which make troubles for ignition in real sites. Therefore, we measured and analyzed ignition voltages from igniters which are used in magnetic and electronic ballast in cables at a distance of 5 meters between a lamp and a igniter to suggests an applicable solution in real sites.

  • PDF