• Title/Summary/Keyword: LAMBDA method

Search Result 524, Processing Time 0.033 seconds

Flow Characteristics of Developing Laminar Steady Flows in a Straight Duct Connected to a Square Curved Duct (곡관덕트에 연결된 정사각단면 직관덕트에서 증류정상유동의 유동장내 유동특성)

  • Sohn Hyun Chul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.5 s.236
    • /
    • pp.545-553
    • /
    • 2005
  • In the present study, The characteristics of developing steady laminar flows of a straight duct connected to a $180^{\circ}$ curved duct were examined In the entrance region through experimental measurement. Flow characteristics such as shear stress distributions, pressure distributions and friction coefficient experimentally in a square cross-sectional straight duct by using the PIV system. For the PIV measurement by particles produced from mosquito coils particles. The experimental data were obtained at 9 points dividing the test sections by 400mm. Experimental results can be summarized as follows. Critical Reynolds number, $Re_{cr}$ which indicates transition from laminar steady flow to transition steady flow was 2,150. Shear stress per unit length on the wall was stronger than that in the fully developed flow region. This was attributed to the fact that shear stress and pressure loss in the curvature of a duct were increased. Pressure distributions were gradually decreased irrespective of Reynolds number In the whole test section. This trends were in a good agreement with the reference results. Pipe friction coefficient in the steady state flow region was calculate from method of least squares. The co-relationship between fiction coefficient and Reynolds number was established as follow; ${\lambda}=56/Re$.

Dynamic response of layered hyperbolic cooling tower considering the effects of support inclinations

  • Asadzadeh, Esmaeil;Alam, Mehtab;Asadzadeh, Sahebali
    • Structural Engineering and Mechanics
    • /
    • v.50 no.6
    • /
    • pp.797-816
    • /
    • 2014
  • Cooling tower is analyzed as an assembly of layered nonlinear shell elements. Geometric representation of the shell is enabled through layered nonlinear shell elements to define the different layers of reinforcements and concrete by considering the material nonlinearity of each layer for the cooling tower shell. Modal analysis using Ritz vector analysis and nonlinear time history analysis by direct integration method have been carried out to study the effects of the inclination of the supporting columns of the cooling tower shell on its dynamic characteristics. The cooling tower is supported by I-type columns and ${\Lambda}$-type columns supports having the different inclination angles. Relevant comparisons of the dynamic response of the structural system at the base level (at the junction of the column and shell), throat level and at the top of the tower have been made. Dynamic response of the cooling tower is found to be significantly sensitive to the change of the inclination of the supporting columns. It is also found that the stiffness of the structure system increases with increase in inclination angle of the supporting columns, resulting in decrease of the period of the structural system. The participation of the stiffness of the tower in structural response of the cooling tower is fund to be dependent of the change in the inclination angle and even in the types of the supporting columns.

Equivalence Ratio Measurements in Gas Spray Using Laser Raman Scattering (Laser Raman Scattering을 이용한 가스 분무내 당량비 계측에 관한 연구)

  • Jin, S.H.;Park, K.S.;Song, J.I.;Kim, G.S.
    • Journal of ILASS-Korea
    • /
    • v.2 no.4
    • /
    • pp.7-14
    • /
    • 1997
  • Laser Raman scattering method has been applied to measure equivalence ratio of methane/air mixture in injected spray. We used high power KrF excimer laser$(\lambda=248nm)$ and a high gain ICCD camera to capture low intensity signal. Raman shifts and Raman scattering cross -sections of $H_2,\;O_2,\;N_2,\;CO_2,\;CH_4\;and\;C_3H_8$ are measured precisely. Our results show an excellent agreement with those of other groups. Mole fraction measurement of $O_2\;and\;N_2$ from air shows that $O_2:N_2=0.206:0.794$. We used gas injector which was operated at 1 bar. Methane is used as a fuel. Spray region is $10mm\times37mm$ and this region is divided into 80 points. In Raman signals are obtained and ensemble averaged for each point. 3-d and contour plot of distribution of equuivalence ratio is presented. Our measured results show that the equivalence ratio of methane/air mixture in methane-rich region is reasonable. However, more study is necessary for methane-lean region because background noise level is almost same as Raman intensity of methane.

  • PDF

Interspecies Comparison of the Oral Absorption of Itraconazole in Laboratory Animals

  • Yoo, Sun-Dong;Kang, Eun-Hee;Shin, Beom-Soo;Lee, Hun-Jun;Lee, Sang-Heon;Lee, Kang-Choon;Lee, Kyu-Hyun
    • Archives of Pharmacal Research
    • /
    • v.25 no.3
    • /
    • pp.387-391
    • /
    • 2002
  • The oral absorption and disposition of itraconazole were studied in rats, rabbits and dogs. Serum levels of itraconazole and its active metabolite, hydroxyitraconazole, were determined by a validated HPLC method. The absorption of itraconazole was relatively rapid in rats and dogs but was slower in rabbits. The terminal elimination half-life ($T_{1/2,{\lambda}z}$), time to the peak concentration ($T_{max}$), dose and weight normalized area under the curve (AUC) and the peak concentration ($C_{max}$) of itraconazole found in the dog were comparable to those reported in humans. As in humans, the metabolite to parent drug AUC ratios in rats and dogs were greater than unity but was less in rabbits. The dog appears to be an appropriate animal model while the rat, not the rabbit, may be used as an alternative animal model in predicting the oral absorption of itraconazole in humans.

Determination of $Cu^{2+}$ by Lophine Chemiluminescence

  • Kim Young-Sun;Karim Mohammad Mainul;Lee Sang-Hak;Choi Kyoung-Hye;Choi Jong-Ha;Lee Sung-Ho
    • Journal of Photoscience
    • /
    • v.12 no.3
    • /
    • pp.137-141
    • /
    • 2005
  • The chemiluminescence reaction of lophine with $H_2O_2$ in alkaline solution has been investigated for use in determination of $Cu^{2+}$ ions. The observed chemiluminescence intensity is found to be a function of the concentration of $Cu^{2+}$. Under the optimum reagent concentrations such as $4{\times}10^{-4}M$ lophine, 0.8 M KOH, 0.2M $H_2O_2,{\lambda}_{em}$, 533nm, the linear range and the detection limit were found to be 0.048ug/ml-48.32ug/ml (R=0.99897) and 0.005ulg/ml respectively. Relative standard deviation for five determinations of 24.16ug/ml $Cu^{2+}$ is 2.35%. The interference from other species was investigated. The proposed method was applied to the determination of $Cu^{2+}$ in different water samples.

  • PDF

Design and Application of Microstrip Line Photonic Bandgap Structure with a Quarter-Wavelength Transformer for The Modified Characteristics of Stopband (변형된 저지특성을 갖도록 ${\lambda}g$/4 변환기를 정합 시킨 마이크로스트립 라인 포토닉 밴드갭 구조의 설계 및 응용)

  • Kim, Tae-Il;Jang, Mi-Yeong;Park, Ik-Mo;Im, Han-Jo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.37 no.9
    • /
    • pp.38-48
    • /
    • 2000
  • This paper presents the photonic bandgap structure that has a defect mode within a broad stopband. In order to create a broad stopband, we eliminated one of periodic stopbands of PBG structure by using a quarter-wavelength transformer and cascaded another PBG structure having a center frequency corresponding to the eliminated stopband. We have demonstrated that it is a simple and effective method that can solve an overlapping problem of periodic stopband in two cascaded PBG structures.

  • PDF

A Study on Convergence Property of Iterative Learning Control (반복 학습 제어의 수렴 특성에 관한 연구)

  • Park, Kwang-Hyun;Bien, Z. Zenn
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.38 no.4
    • /
    • pp.11-19
    • /
    • 2001
  • In this paper, we study the convergence property of iterative learning control (ILC). First, we present a new method to prove the convergence of ILC using sup-norm. Then, we propose a new type of ILC algorithm adopting intervalized learning scheme and show that the monotone convergence of the output error can be obtained for a given time interval when the proposed ILC algorithm is applied to a class of linear dynamic systems. We also show that the divided time interval is affected from the learning gain and that convergence speed of the proposed learning scheme can be increased by choosing the appropriate learning gain. To show the effectiveness of the proposed algorithm, two numerical examples are given.

  • PDF

A Plausible Method for the Diagnosis of Genetic Disorders Using Full Length cDNA

  • Hur, Hyang-Suk;Lee, Young-Won;Park, Hyoung-Woo;Kim, Myoung-Hee
    • Biomedical Science Letters
    • /
    • v.7 no.1
    • /
    • pp.1-5
    • /
    • 2001
  • A cDNA of coagulation Factor IX gene has been screened from the $\lambda$gt11 human fetal liver cDNA library, and used to construct a 2.8-kb full length cDNA after recombining with the N-terminal fragment from pTZ-FIX. Human genomic DNA was isolated, digested with the restriction endonucleases, TaqI, EcoRI, and HindIII, and Southern hybridization was performed using the full length factor IX cDNA as a probe. The hybridized bands generated by the restriction endonucleases were the followings: TaqI, 0.3, 1.0, 1.6, 1.8, 2.7, 3.7, and 5.3 kb bands; EcoRI, 1.8, 4.8, 4.9, 5.5, 6.8, and 12.6 kb bands; HindIII, 4.1, 4.4, 5.2, 5.8, 7.6, and 12.5 kb bands. When the Southern bands were physically mapped along the genome, about 50-kb continuous region harboring almost all of the genomic region of Factor Ⅸ gene was covered. These results suggest a possibility of using an exonal cDNA probe to diagnose abnormalities including large deletions, insertions, and rearrangements along the genome, if there is any.

  • PDF

A DNA Microextractor Using Crossed Field Electrophoresis (교차 전기영동법을 이용한 극소형 DNA 추출기)

  • Yi Soyeon;Seo Kyoung-Sun;Cho Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.8 s.227
    • /
    • pp.1135-1139
    • /
    • 2004
  • This paper presents a microextractor for the separation of DNA molecules by their sizes. The DNA microextractor immobilizes the DNA molecules of specific size in the micropillar array by adjusting the period of the crossed electric field, thus providing a starting-point independent target DNA extraction method without separation process monitoring. The DNA microextractor has been fabricated by a three-mask micromachining process. The velocity of three different DNA molecules has been measured at the electric field of E=5V/0.8cm in the fabricated DNA microextractor, resulting in the reorientation times of $4.80{\pm}0.44sec,\;7.12{\pm}0.75sec$, and $9.88{\pm}0.30sec$ for ${\lambda}$ DNA, micrococcus DNA, and T4 DNA, respectively. T4 DNA is trapped in the micropillar array when the crossed electric field of 5V/0.8cm is applied alternately at a 10 second time interval. The present DNA microextractor filters the DNA in a specific size range by adjusting the magnitude and/or the period of the crossed electric field applied in the micropillar array.

CO Selox Reaction Using Y-type Zeolite Catalytic Membranes

  • Bemardo, P.;Algieri, C.;Barbieri, G.;Drioli, E.
    • Korean Membrane Journal
    • /
    • v.8 no.1
    • /
    • pp.13-20
    • /
    • 2006
  • The production of CO-free hydrogen streams for feeding PEM-Fuel Cells using catalytic zeolite membrane reactors was analysed by means of selective oxidation. Tubular FAU (Na-Y) zeolite membranes, prepared by a secondary growth method and Pt-loaded, were used in a flow-through MR configuration. The catalytic tests were carried out at $200^{\circ}C$ and at different pressures with a simulated dry reformate shifted gas mixture ($H_2$ ca. 60%, CO 1 %, plus $O_2,\;N_2,\;CO_2$). The operative $O_2/CO$ stoichiometric equivalent feed ratio was ${\lambda}= 2$. These catalytic tests, reducing the CO concentration down to $10{\sim}50$ ppm, verified the possibility of MR integration after using a low temperature water-gas shift unit of a fuel processor to convert hydrocarbons into hydrogen-rich gas.