• 제목/요약/키워드: L-probe

검색결과 402건 처리시간 0.02초

Effect of Do-In (Prunus persica L. BATSCH) Water Extract (PPE) on Concentration of Extracellular Acetylcholine in the Rat Hippocampus

  • Gong Dae-Jong;Kim Geun-Woo;Koo Byung-Soo
    • 대한한의학회지
    • /
    • 제25권4호
    • /
    • pp.1-7
    • /
    • 2004
  • Objective : This study was designed to examine the effects of orally administered Prunus persica water extract (PPE), which is used as herbal medicine, for treatment of Yu Xue (stasis of blood) and tacrine on the basal concentration of extracellular acetylcholine in the hippocampus of rats. Methods: To investigate the effects of PPE and tacrine on concentration of extracellular acetylcholine in the hippocampus of rats, the microdialysis technique, under the same experimental conditions, was used. And we used male Wistar rats which were 7 weeks of age and 210-290 g. PPE was extracted with boiling water, and the rats were anesthetized with pentobarbital Na. Their skulls were exposed and a hole was drilled for implantation of a microdialysis probe. In order to increase the recovery of acetylcholine, a probe with a long membrane was used. One day after surgery, the microdialysis probe was perfused with Ringer's solution at a flow rate of 1.5 l/min. The acetylcholine concentration in dialysis samples was measured by high-performance liquid chromatography (HPLC) with electrochemical detection. AChE activity was measured using the radiometric method, as described by Sherman. Results : The comparative effects of PPE and tacrine on hippocampal extracellular acetylcholine concentration was that these cholinesterase inhibitors produced dose-dependent increases in the extracellular acetylcholine concentration. And the effect of PPE and tacrine on rat brain AChE activity was that PPE produced maximal inhibition at 1 h after administration, when AChE activity was 44% of the intact level. AChE activity gradually recovered thereafter, and reached 78% of the intact level at 12 h after administration. Conclusion : In this study, PPE has a potent activity and a long-lasting effect on the central cholinergic system, in terms of the basal concentration of extracellular acetylcholine in the hippocampus and the AChE activity in the brain of rats. And oral administration of PPE increased dose-dependently the basal concentration of extracellular acetylcholine in the hippocampus of rats. PPE may be one of the more useful cholinesterase inhibitors for the treatment of Alzheimer's disease.

  • PDF

Endoscopic Transforaminal Suprapedicular Approach in High Grade Inferior Migrated Lumbar Disc Herniation

  • Kim, Hyeun-Sung;Ju, Chang-Il;Kim, Seok-Won;Kim, Jong-Gue
    • Journal of Korean Neurosurgical Society
    • /
    • 제45권2호
    • /
    • pp.67-73
    • /
    • 2009
  • Objective : Although endoscopic procedures for lumbar disc diseases have improved greatly, the postoperative outcomes for high grade inferior migrated discs are not satisfactory. Because of anatomic limitations, a rigid endoscope cannot reach all lesions effectively. The purpose of this study was to determine the feasibility of endoscopic transforaminal suprapedicular approach to high grade inferior-migrated lumbar disc herniations. Methods : Between May 2006 and March 2008, a suprapedicular approach was performed in 53 patients with high grade inferior-migrated lumbar disc herniations using a rigid endoscope and a semi-rigid flexible curved probe. One-to-four hours after surgery, the presence of remnant discs was checked with MRI. The outcomes were evaluated with the visual analogue scale (VAS) score and the Oswestry Disability Index (ODI) one week after surgery. Results : The L2-3 level was involved in 2 patients and the L3-4 level was involved in 14 patients, while the L4-5 level was involved in 39 patients. There were single piece-type in 34 cases and a multiple piece-type in 19 cases. Satisfactory results were obtained in all cases. The mean preoperative VAS for leg pain was $9.32{\pm}0.43$ points (range, 7-10 points), whereas the mean ODI was $79.82{\pm}4.53$ points (range, 68-92 points). At the last follow-up examination, the mean postoperative VAS for leg pain was $1.78{\pm}0.71$ points and the mean postoperative ODI improved to $15.27{\pm}3.82$ points. Conclusion : A high grade inferior migrated lumbar disc is difficult to remove sufficiently by posterolateral endoscopic lumbar dscectomy using a rigid endoscope. However, a satisfactory result can be obtained by applying a transforaminal suprapedicular approach with a flexible semi-rigid curved probe.

CDMA2000시스템에 있어서 액세스채널 알고리즘 개선 (Improvement of the access channel algorithm in the CDMA2000 system)

  • 이광재;천종훈;박종안
    • 한국통신학회논문지
    • /
    • 제30권3B호
    • /
    • pp.138-143
    • /
    • 2005
  • 본 연구는 CDMA2000 시스템에 있어서의 액세스 프로브 알고리즘을 최적화하고자 한다. 이동국이 액세스 채널을 통하여 송신하고 기지국으로부터 ACK 메시지를 받지 못 할 경우 수신신호가 양호한 지역에서는 PWR_STEP 증분값이 1dEm±0.2 값으로 NUM_STEP만큼 증분하여 액세스 프로브를 하게 된다. 그러나 수신신호가 약한 지역에서는 개방루프 전력제어 알고리즘에 따라 송신부 전력 증폭기가 포화상태에 이르게 되어 PWR_STEP 증분값이 0dBm± 0.2값으로 계속해서 액세스 프로브를 하게 되어 이동국 송신에 따른 간섭현상과 배터리 소비전력이 증가하게 된다. 이와 같은 문제를 해결하기 위하여 우리는 수신신호가 강한 지역에서는 IS-95C규격과 같이 RT 슬롯 값만큼 그리고 수신신호가 미약한 지역에서는 RT+1 슬롯 값만큼 지연하여 액세스 프로브 전력 증분값으로 송신하도록 하여 수신세기에 따라 액세스 프로브 알고리즘을 최적화하였다. 시뮬레이션 결과로부터 제안된 알고리즘이 이동국 송신전력에 따른 간섭현상과 소모 전력을 감소시키고 이로 인해 단말기의 총 통화시간을 향상시킬 수 있음을 확인하였다.

콩의 RAPD 연관지도를 RFLP 연관지도와 합병 (Incorporation of RAPD linkage Map Into RFLP Map in Glycine max (L, ) Merr)

  • Choi, In-Soo;Kim, Yong-Chul
    • 생명과학회지
    • /
    • 제13권3호
    • /
    • pp.280-290
    • /
    • 2003
  • RAPD 연관지도를 RFLP 연관지도와 합병을 하는 것은 각각의 유전 marker들의 단점을 서로 보완하여 세밀화된 유전자 지도작성을 용이하게 할 수 있다. 본 연구는 Essex와 PI 437654의 $F_2$$F_3$ 후대계통들을 재료로 하여 작성된 RAPD 연관지도를 콩의 RFLP 연관지도와 합병을 함에 있어서 나타난 몇가지 특징들을 기술하고자 함을 목적으로 하는 바 그 특징들은 아래와 같이 요약된다. 1. RAPD 연관지도상에서의 RFLP probe들의 위치가 RFLP 연관지도상에서의 위치와 부분적으로 변동된 현상이 나타났다. RAPD 연관그룹 L.G.C-3을 RFLP 연관그룹 a1 및 a2와 합병하는 과정에서 pSAC3와 pA136, 그리고 pA170/EcoRV와 pB170/HindIII이 서로 반대방향으로 위치하였다. pK400은 RFLP 연관지도상에서는 pA96-1과 pB172의 사이에 위치한 반면 RAPD 연관지도상에서는 i locus와 pA85 사이에 위치하였다. 2. RAPD 연관지도상에서의 두 marker들간의 간격이 RFLP 연관지도상에서의 간격보다 멀어진 현상이 두드러지게 나타났다. pA890과 pK493간의 간격은 RAPD 연관그룹 L.G.C-1에서는 48.6 cM이었던 반면 RFLP 연관 그룹상에서는 단지 13.3 cM으로 나타났다. 또한 pB32-2와 pA670, pA670과 pA668사이의 간격은 RAPD 연관그룹 L.G.C-2에서는 50.9 cM과 31.7 cM이었던 반면, RFLP 연관지도상에서의 간격은 각각 35.9 cM과 13.5 cM으로 나타났다. 3. 하나의 RFLP probe로부터 두개 이상의 다형화 현상을 나타낸 marker들이 동일한 연관그룹이나 다른 연관그룹에 위치하는 현상이 나타났다. 제한효소 HindIII로 절단된 probe pK418은 세개의 marker를 나타내었는데, 그 중 하나는 L.G.C-20에 위치하였으며, 다른 두개는 L.G.C-4에 위치하였다. 위에 나타난 특징들은 RAPD 연관지도는 intraspecific cross의 후대계통들을 재료로 하여 작성된 반면 RFLP 연관지도는 interspecific cross의 후대계통들을 재료로 하여 작성된 결과에선 비롯된 차이점 때문인 것으로 추측된다.

미소전극 센서를 이용한 탈질 생물막내의 이온 농도측정 (Measurement of Ion Concentrations in Denitrifying Biofilm by Microelectro-sensor)

  • 장암;이쌍구;김성민;김인수
    • 대한환경공학회지
    • /
    • 제22권10호
    • /
    • pp.1833-1841
    • /
    • 2000
  • 생물학적 수처리공정의 생물막 (호기성 혹은 혐기성) 내의 생물막 두께 및 이온들의 농도구배등에 대한 모델링을 위하여 종래에 이론적으로만 접근하던 방법 대신, 실제로 생물막을 이동하며 측정하여 분석하는 첨단 연구 방법인 미소전극탐침을 제작하여 적용하였다. 미소전극 센서장치에서 가장 중요한 요소 중에 하나인 working 미소전극탐침은 생물막내의 전위차 (EMF, electromotive force)를 측정할 때 오염과 파손 등에 의해서 수명이 짧아지기 쉽기 때문에, 각각의 working 미소전극탐침의 제작방법에 대하여 논의하였으며, 제작된 pH와 $NO_3{^-}$ 미소전극탐침으로 탈질 미생물막 이온들의 농도를 막 깊이별로 측정하였다. 미소전극 센서장치에 의한 측정결과, 탈질 미생물막 내부에서의(생물막 표면에서 약 $350{\mu}m$) pH는 8.3 정도로 벌크용액상(bulk solution)의 pH 8보다 약간 상승하였으며, $NO_3{^-}$의 농도는 벌크용액상의 30 mg N/L농도에서 최종 4 mg N/L 청도로 나타났다.

  • PDF

The 16S rDNA Gene Sequencing and Specific Probes Designing for the Identification of Edwardsiella tarda

  • Lee Ju Suk;Choi Jae Young;Sim Doo Saing;Kim Hyeung Rak;Jung Tae Sung;Kim Jae Ho;Oh Myung Joo
    • Fisheries and Aquatic Sciences
    • /
    • 제3권1호
    • /
    • pp.64-70
    • /
    • 2000
  • DNA probes for the l6S rRNA have been designed for the detection of Edwardsiella tarda. In order to accomplish this purpose, the l6S rRNA gene from E. tarda has been cloned and sequenced. Two highly feasible oligonucleotide probe sites have been determined by the database analysis programs presented by PCGENE and BLAST. These two probes have been evaluated by slot blot hybridization analysis. Hetero- and homo-trimeric templates have been synthesized using these two probe sites. The templates have been further multimerized by PCR to generate between 150 and 300 bp long DIG-11-dUTP labeled probes. Unlike 3' end labeled oligonucleotide probes or templates, multimerized probes showed no cross­hybridization in the given experimental condition. Furthermore, a significant increase in sensitivity has been observed with these probes. This method, we presented here, may be useful for the designing of probes for the detection of other fish pathogenic microorganisms also.

  • PDF

초음파 영상에서 동적영역과 주파수 방식의 설정에 따른 효과 (Effects of Settings in Dynamic Ranges and Frequency Modes on Ultrasonic Images)

  • 양정화;강관석;이경성;팽동국;최민주
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제32권3호
    • /
    • pp.277-283
    • /
    • 2009
  • 임상에서 정확한 진단을 위해 양질의 초음파 영상을 얻는 것은 중요하다. 본 연구에서는 초음파 진단기의 주파수와 동적 영역(dynamic range, DR) 설정 및 프로브 유형에 따른 초음파 영상의 변화를 관찰하였다. 실험에서 고형 및 낭성 종괴 병변과 유사한 초음파 평가 팬텀(539,551, ATS, USA)의 6가지 LCS(low contrast sensitivity) 표적(-15, -6, -3, +3, +6, +15 dB)에 대한 영상을 대상으로 평가하였다. 초음파 영상은 볼록형(convex, C3-7IM) 및 선형(linear probe, L5-12IM) 두 가지 탐촉자(Probe)에 대해 SA-9900(Medison Ltd, Korea)을 이용하여 얻었다. 주파수는 4가지 방식(gen, pen, res, harmonic), 동적영역은 $40{\sim}100\;dB$ 범위에서 설정을 변화하면서 영상을 취득하였다. 취득한 영상의 질은 표적의 명목상 LCS 값과 영상에서 측정된 LCS을 비교하여 평가 하였다. 실험 결과 볼록형 탐촉자의 경우, 각 LCS 표적에 대해 주파수 방식 별로 동적영역 값을 40, 60, 80, 100 dB로 변화할 때, 초음파 영상의 질은 유의한 변화가 없었다. 그러나 낭종성 병변에 가까운 LCS 표적 -15 dB에서는 동적영역 60 dB과 하모닉 주파수 방식에서 LCS 값이 높게 나타났다. 선형 프로브에서는 -15 dB LCS 표적에서 동적영역 40 dB, 하모닉 방식에서 명목상 값에 근접하였다. LCS관점에서 정량화된 영상의 평가의 한계와 주관적인 평가 즉 심리적인 관점에서의 ROC(Receiver Operating Characteristic) 평가의 필요성에 대해 토의하였다.

  • PDF

GISH와 FISH를 이용한 양파와 파간 종간교잡계통의 염색체 분석 (Chromosome Analysis Using GISH and FISH of Interspecific Hybrids between Allium cepa L. and A. fistulosum L.)

  • 김철우;이을태;김화영;최인후;방진기;구달회;방재욱
    • 한국육종학회지
    • /
    • 제41권4호
    • /
    • pp.468-473
    • /
    • 2009
  • 본 연구에서는 양파와 파간 종간교잡 F1의 불임성의 한 요인으로 여겨지는 염색체 이상과 교잡식물체의 염색체의 조성을 밝혀 향후 종간교잡을 이용한 양파의 형질개량과정에 종간교잡 육종의 효율성을 높이고자 하였다. 종간교잡식물체의 감수분열 염색체를 관찰한 결과 중기에 7쌍의 2가염색체와 2개의 1가염색체가 관찰되었다. 체세포 염색체수는 16개로 양파, 파의 염색체 수와 같았으며 GISH한 결과 파와 양파의 염색체가 각각 8개씩 확인되었다. 5S, 45S, TSD DNA를 probe로 하여 양파, 파, 종간잡종의 염색체의 signal을 관찰한 결과 5S와 45S rDNA는 는 3종 모두에서 1쌍의 염색체에서 나타났는데 5S의 경우 염색체의 subcentromeric 에서 45S는 부수체 염색체에서 관찰되었다. TSD DNA는 염색체의 telomeric 부위에서 관찰되었으나 양파의 경우 2쌍은 염색체의 말단부와 중심체 부분에서 signal이 관찰되었고 종간교잡 세포에서도 2쌍이 관찰되어 양파에서 유래된 염색체임이 확인되었다.

Objectively Predicting Ultimate Quality of Post-Rigor Pork Musculature: I. Initial Comparison of Techniques

  • Joo, S.T.;Kauffman, R.G.;Warner, R.D.;Borggaard, C.;Stevenson-Barry, J.M.;Lee, S.;Park, G.B.;Kim, B.C.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제13권1호
    • /
    • pp.68-76
    • /
    • 2000
  • A total of 290 pork loins were selected to include a wide variation of quality to investigate the quality categories into which most pork falls, selection criteria for these categories and methods to objectively assess ultimate pork quality. They were probed at 24 h postmortem (PM) for the following: A) light reflectance by Danish Meat Quality Marbling (MQM), Hennessy Grading Probe (HGP) and Sensoptic Invasive Probe (SIP); B) electrical properties by NWK LT-K21 conductivity (NLT) and Sensoptic Resistance Probe (SRP): and C) pH by NWK pH-K21 (NpH). Also, measurements of % drip loss (PDL) and filter paper wetness (FPW), color brightness (L*), ultimate pH (pHu), lipid content, subjective color (SC), firmness/wetness (SF) and marbling scores (SM) were assessed. Each loin was categorized as either pale, soft and exudative (PSE), reddish-pink, soft and exudative (RSE), reddish-pink, firm and non-exudative (RFN) or dark, firm and dry (DFD). Statistically comparing coefficients of determination (CD), the results indicated that overall, the HGP predicted quality groups slightly better than MQM (CD=71 and 62% respectively), NpH and SRP were less effective (CD= 56 and 44% respectively), and SIP and NLT had the lowest values (CD=36 and 5% respectively). Combining various independent variable did not greatly improve the variation accounted for. When the data was sorted into marbling groups based on lipid content, this was not accurately predicted by any of the probe measurements. The MQM probe remained the best predictor for marbling class and accounted for about 25% of the lipid content variation. This was slightly improved to 33% when pHu was combined with MQM.

비접촉식 진동 변위센서의 특성에 관한 연구 (Study on characteristics of noncontact vibrating displacement sensor)

  • 조철환;조성태;양경현
    • 동력기계공학회지
    • /
    • 제15권2호
    • /
    • pp.13-18
    • /
    • 2011
  • This thesis is about the result of conducting a specific experiment for the development of noncontact vibration displacement sensor for measuring the spindle vibration that is used for conditional monitoring of machinery. One should be careful when using the eddy current type displacement sensor because the sensitivity of it is different according to the quality of the material. While the probe used for nondestructive inspection adopts the effect of transmitting the material by using the high frequency domain, the eddy current type displacement sensor uses the lower frequency of around 1MHz. Also, while the nondestructive probe uses the method of enhancing output by using the resonance zone, the vibration displacement sensor utilizes the stable zone by avoiding the resonance zone. Since the oscillator of the converter uses the "L" element as Probe, its characteristic changes with the variation of a relevant impedance. In other words, if the length of Probe's Cable gets extended (Impedance increase), the sensitivity declines accordingly. The effect of surrounding temperature was small, but the influence of the quality of Sensor Coil used was high. Moreover, following an experimental demonstration of the phenomenon where the sensitivity decreases as the frequency of the tested material increases from a frequency response test, the maximum frequency that could be measured was approximately 1KHz. It was noted that the degree of precision could be maintained by using the gap of the probe in the linear zone at the installation site.