• Title/Summary/Keyword: L-joint

Search Result 621, Processing Time 0.036 seconds

Origins and Protective Schemes of Leaking Water into the Buddhist Triad Cave in Gunwi (군위 삼존석굴의 누수 원인과 방지대책)

  • Hwang, Sang Koo
    • Journal of Conservation Science
    • /
    • v.11 no.1 s.14
    • /
    • pp.15-27
    • /
    • 2002
  • The Buddhist Triad Cave in Gunwi, which consists of porphyritic biotite granite, has been deteriorated by a few weatherings. Origin of the weatherings is rain that can be leaked into the cave. Therefore the author investigates a few possible joints and bypasses leaking water, and reinforces any protective schemes for the rain influx. The porphyritic granite around the cave regularly develops two NEE and NWW joint sets. The NEE joint set could be divided into 4 joint zones among which $J_m\;and\;J_3$ may directly affect the leaking water into the cave. A extensional joint, in northern wall of the cave, runs through the $J_m$ joint zone. A small rain could rarely gets through the bypass, but a heavy rain has a good circulation through the joints to be leaked into the cave for a long time because of its long way. Many joints and cracks, in the ceiling near the cave entrance, immediately get to the $J_3$ joint zone, and have a good circulation of a small rain 10 mm. It is the desirable protective schemes that forbid rains to influx along the ranges from L -9 m to +10 m in the $J_m$ joint zone and upper half circle with radius 5 m in the $J_3$ joint zone. The joint apertures should be filled with a petro-epoxy and petro-filler to stop the water flow.

  • PDF

Experimental seismic behaviour of L-CFST column to H-beam connections

  • Zhang, Wang;Chen, Zhihua;Xiong, Qingqing;Zhou, Ting;Rong, Xian;Du, Yansheng
    • Steel and Composite Structures
    • /
    • v.26 no.6
    • /
    • pp.793-808
    • /
    • 2018
  • In this study, the seismic performance of the connections between L-shaped columns composed of concrete-filled steel tubes (L-CFST columns) and H-beams used in high-rise steel frame structures was investigated. Seven full-scale specimens were tested under quasi-static cyclic loading. The variables studied in the tests included the joint type, the axial compression ratio, the presence of concrete, the width-to-thickness ratio and the internal extension length of the side plates. The hysteretic response, strength degradation, stiffness degradation, ductility, plastic rotation capacity, energy dissipation capacity and the strain distribution were evaluated at different load cycles. The test results indicated that both the corner and exterior joint specimens failed due to local buckling and crack within the beam flange adjacent to the end of the side plates. However, the failure modes of the interior joint specimens primarily included local buckling and crack at the end plates and curved corners of the beam flange. A design method was proposed for the flexural capacity of the end plate connection in the interior joint. Good agreement was observed between the theoretical and test results of both the yield and ultimate flexural capacity of the end plate connection.

Measurement on comfort range of korean population's joint motions for designing and evaluating workplaces

  • 기도형
    • Journal of the Ergonomics Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.73-82
    • /
    • 1997
  • Daily exposure to constrained body postures and deviations from neutral postures over a long period may result in discomfort as well as pains and aches in the muscles, joints, tendons, and other soft tissues. Furthermore, it was known that poor body postures are a major cause of musculoskeletal disorders in industry. Therefore, in this study, comfort ranges of joint motions were obtained as a criterion for evaluating body postures and designing workplaces ergonomically, which were bases on subjects' perceived discomfort level estimated by magnitude estimation. Nineteen healthy male subjects participated in the laboratory study. They results showed that comfort ranges of joint motions occurred in the wrist, elbow, neck, and ankle were little less than their normal range of joint motions, but those in the back(L5/S1) and hip joint were much less than their normal ones. This fact implies that the back and jip movements are more stressful than the other joints movements. It is expected that comfort ranges of joint motions can be used as a valuable guideline when designing and evaluating workplaces.

  • PDF

A Study on GMA Welding Automation of STS301L Joint using Design of Experiment (실험계획법을 이용한 STS301L 이음재의 GMA 용접 자동화에 관한 연구)

  • Baek, Seung-Yeb;Sohn, Il-Seon
    • Journal of Welding and Joining
    • /
    • v.28 no.4
    • /
    • pp.49-54
    • /
    • 2010
  • Stainless steel sheets are widely used as the structural material for the railroad cars and the commercial vehicles. These kinds structures used stainless steel sheets are commonly fabricated by using the GMAW (gas metal arc welding). For fatigue design of GMA welded joints such as fillet and plug, ring type joint, it is important to obtain optimum design factor information on GMA welded joints. in this paper, analysis approach for fatigue test using design of experiment are evaluated optimum factor in GMA welded joint type and geometrical parameters of materials. Using these results, that factors applied to fundamental information for fatigue design.

Zigzag gait of a Quadruped Walking robot with waist joint

  • Park, Se Hoon;Lee, Yun Jung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.108.3-108
    • /
    • 2002
  • $\textbullet$ Introduction $\textbullet$ trend of walking robot $\textbullet$ Characteristics of waist-jointed walking robot $\textbullet$ simulation $\textbullet$ conclusion

  • PDF

Analgesic Effects of Triptolide and N-nitro-L-arginine Methyl Ester in Rat's Temporomandibular Joint Pain Model (흰 쥐의 측두하악관절 통증모델에서 Triptolide와 N-nitro-L-arginine Methyl Ester의 통증조절효과)

  • Kim, Yun-Kyung;Lee, Min-Kyung
    • Journal of dental hygiene science
    • /
    • v.15 no.6
    • /
    • pp.800-806
    • /
    • 2015
  • The aim of this study was to investigate whether intracisternal administrations of triptolide and N-nitro-L-arginine Methyl Ester (L-NAME) are involved in the regulation of temporomandibular joint (TMJ) pain. The TMJ pain was induced by the injection of 5% formalin ($30{\mu}l$) into TMJ capsule of rats. The pain behavioral responses was recorded the number of grooming or scratching on the left TMJ area for 9 successive 5 minutes intervals. Triptolide and L-NAME were administrated intracisternally 10 minutes before formalin injection. The intra-articular injection of formalin produced a biphasic pattern of pain response (first phase: 0~10 minutes and second phase: 11~45 minutes). The intracisternal administration of triptolide ($1{\mu}g/10{\mu}l$) and L-NAME ($0.1{\mu}g/10{\mu}l$) suppressed the TMJ pain behavior in each experiment. Co-administration of two drugs was shown the enhanced effect than the analgesic effect by single-administration of triptolide ($1{\mu}g/10{\mu}l$). The triptolide could be a useful analgesic agent for the treatment of TMJ pain, and it is expected to reduce the substantial amount of it via co-administration of synthetic chemical compound and natural products.

Constraint of Semi-elliptical Surface Cracks in T and L-joints (T-형 및 L-형 배관내 반타원 표면균열에서의 구속상태)

  • Lee, Hyeong-Il
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.9
    • /
    • pp.1325-1333
    • /
    • 2001
  • Critical defects in pressure vessels and pipes are generally found in the form of a semi-elliptical surface crack, and the analysis of which is consequently an important problem in engineering fracture mechanics. Furthermore, in addition to the traditional single parameter K or J-integral, the second parameter like T-stress should be measured to quantify the constraint effect. In this work, the validity of the line-spring finite element is investigated by comparing line-spring J-T solutions to the reference 3D finite element J-T solutions. A full 3D-mesh generating program for semi-elliptical surface cracks is employed to provide such reference 3D solutions. Then some structural characteristics of the surface-cracked T and L-joints are studied by mixed mode line-spring finite element. Negative T-stresses observed in T and L-joints indicate the necessity of J-T two parameter approach for analyses of surface-cracked T and L-joints.

Unilateral Biportal Endoscopic Spinal Surgery Using a 30° Arthroscope for L5-S1 Foraminal Decompression

  • Kim, Ju-Eun;Choi, Dae-Jung
    • Clinics in Orthopedic Surgery
    • /
    • v.10 no.4
    • /
    • pp.508-512
    • /
    • 2018
  • Foraminal decompression using a minimally invasive technique to preserve facet joint stability and function without fusion reportedly improves the radicular symptoms in approximately 80% of patients and is considered one of the good surgical treatment choices for lumbar foraminal or extraforaminal stenosis. However, proper decompression was not possible because of the inability to access the foramen at the L5-S1 level due to prominence of the iliac crest. To overcome this challenge, endoscopy-based minimally invasive spine surgery has recently gained attention. Here, we report the technical skills required in unilateral extraforaminal biportal endoscopic spinal surgery using a $30^{\circ}$ arthroscope to enable foraminal decompression at the L5-S1 level. Two 0.8-cm portals were created 2 cm lateral from the lateral border of the pedicles at the L5-S1 level. After sufficient working space was made, half of the superior articular process (SAP) in the hypertrophied facet joint was removed using a high-speed burr and a 5-mm wide osteotome, whereas the remaining inside part of the SAP was removed using a Kerrison punch and pituitary punch. The foraminal ligamentum flavum should be removed to inspect the conditions of the L5 exiting root and disc. Removing of the extruded disc could decompress the L5 root. The extraforaminal approach using a $30^{\circ}$ arthroscope is considered a minimally invasive alternative technique for decompressing foraminal stenosis at the L5-S1 level that preserves facet stability and provides symptomatic relief.

Microstructure of the Brazed Joint for LRE Injector (액체로켓엔진용 인젝터 접합부의 미세조직)

  • 남대근;홍석호;이병호
    • Proceedings of the KWS Conference
    • /
    • 2004.05a
    • /
    • pp.87-89
    • /
    • 2004
  • Brazing is an indispensable manufacturing technology for liquid rocket engine. In this study, for LRE injector, stainless steel 316L was used of base metal and Ni based MBF-20 of insert metal. The brazing and diffusion was carried out under various conditions. There are solid phase and. residual liquid phase in the brazed joint. With increment of holding time, the amount of solid phase increased and the elements of base metal and insert metal compositionally graded. Boron diffused from insert metal came into base metal and made boride with Cr and Mo at the brazed joint of base metal and insert metal.

  • PDF