• Title/Summary/Keyword: L-DOC

Search Result 165, Processing Time 0.033 seconds

Rejection property of geosmin and 2-Methylisoborneol (MIB) with high concentration level at multi stage nanofiltration (NF) membrane system (다단 나노여과 공정에서 고농도 geosmin 및 2-Methylisoborneol (MIB)의 제거특성)

  • Yu, Young-Beom;Choi, Yang Hun;Kim, Dong Jin;Kwon, Soon-Buhm;Kim, Chung-Hwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.4
    • /
    • pp.397-409
    • /
    • 2014
  • Algal problem in drinking water treatment is being gradually increased by causing deterioration of water supplies therefore, especially taste and odor compounds such as geosmin and 2-MIB occur mainly aesthetic problem by its unpleasant effects resulting in the subsequent onset of complaints from drinking water consumer. Recently, geosmin and 2-MIB are detected frequently at abnormally high concentration level. However, conventional water treatment without advanced water treatment processes such as adsorption and oxidation process, cannot remove these two compounds efficiently. Moreover, it is known that the advanced treatment processes i.e. adsorption and oxidation have also several limits to the removal of geosmin and 2-MIB. Therefore, the purpose of this study was not only to evaluate full scale nanofiltration membrane system with $300m^3/day$ of permeate capacity and 90% of recovery on the removal of geosmin and 2-MIB in spiked natural raw water sources at high feed concentration with a range of approximately 500 to 2,500 ng/L, but also to observe rejection property of the compounds within multi stage NF membrane system. Rejection rate of geosmin and 2-MIB by NF membrane process was 96% that is 4% of passage regardless of the feed water concentration which indicates NF membrane system with an operational values suggested in this research can be employed in drinking water treatment plant to control geosmin and 2-MIB of high concentration. But, according to results of regression analysis in this study it is recommended that feed water concentration of geosmin and 2-MIB would not exceed 220 and 300 ng/L respectively which is not to be perceived in drinking tap water. Also it suggests that the removal rate might be depended on an operating conditions such as feed water characteristics and membrane flux. When each stage of NF membrane system was evaluated relatively higher removal rate was observed at the conditions that is lower flux, higher DOC and TDS, i.e., $2^{nd}$ stage NF membrane systems, possibly due to an interaction mechanisms between compounds and cake layer on the membrane surfaces.

Removal of Color from a Biological Piggery Wastewater Treatment Effluent by Chemical Coagulation (화학적 응집을 이용한 생물학적 돈분폐수 처리수의 색도제거)

  • Park, Noh-Back;Seo, Tae-Kyeong;Choi, Woo-Young;Jun, Hang-Bae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.10
    • /
    • pp.1047-1053
    • /
    • 2008
  • This study was to evaluate the optimum conditions for chemical coagulation to remove color from the effluent of a piggery wastewater treatment process. The DOC concentration in the effluent was about 227.3 mg/L, color was 2,430 CU, turbidity was 22.1 NTU, and UV$_{254}$-absorbance was 3.7 cm$^{-1}$. The fractions of hydrophobic, transphilic, and hydrophilic substance of the effluent was about 55.3%, 17.4%, 27.3% respectively. Also, molecular weight cut-off(MWCO) of below 0.5 K, 0.5 K to 1 K, 1 K to 10 K, 10 K to 30 K, and over 30 K were 74.2%, 7.3%, 5.5%, 7.1%, and 5.9% respectively. SCD(streaming current Detector) was used to find out the optimum pH values and coagulant dosages. The optimum dosages and pH of Al$^{3+}$ were 5.84 mM and 5.3, while those of Fe$^{3+}$ were 9.25 mM and 5.0, respectively. At optimum conditions of coagulation, color removal efficiencies for aluminium sulfate and ferric chloride were as high as 91.9 and 98.7%, respectively. Chemical coagulation showed good performance to remove color from on biologically treated piggery wastewater.

An Application of $^{13}C$ Tracer for the Determination of Primary Productivity and Fatty Acid Production Rate in Shingu Reservoir (신구저수지의 1차 생산 및 지방산 생성속도 결정을 위한 $^{13}C$ 추적자 활용 연구)

  • Lee, Yeon-Jung;Kim, Min-Seob;Shin, Kyung-Hoon;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.41 no.spc
    • /
    • pp.21-26
    • /
    • 2008
  • The in situ incubation experiment was carried out using $^{13}C$ tracer to determine primary productivity and fatty acid production rate in the shallow, eutrophic Shingu reservoir on 4th July. Particulate organic matter (POM) accounted for 76% in suspended particulate matter (SPM), and average concentration of chlorophyll-${\alpha}$ was $89{\mu}g\;L^{-1}$ in the euphotic layer. Total amount of chlorophyll-${\alpha}$ (Chl-${alpha}$), primary productivity and Chl-${alpha}$ specific productivity in euphotic layer were 112 mg Chl-${alpha}m^{-2}$, 3.53 g C $m^{-2}\;d^{-1}$, 32mg C mg Chl-${\alpha}^{-1}\;d^{-1}$, respectively. The fatty acid composition in newly produced organic matter and suspended organic matter didn't show any significant difference, demonstrating that autochthonous organic matter should be a major source of POM pool. In addition, the fatty acids of bacterial origin were increased through extracellular release of newly photosynthesized DOC, and closely coupled with bacterial assimilation. This result suggests that organic carbon should be actively cycled through the microbial loop in Shingu reservoir in summer.

Development of Sensor Network Simulator for Estimating Power Consumption and Execution Time (전력소모량 및 실행시간 추정이 가능한 센서 네트워크 시뮬레이터의 개발)

  • Kim, Bang-Hyun;Kim, Tae-Kyu;Jung, Yong-Doc;Kim, Jong-Hyun
    • Journal of the Korea Society for Simulation
    • /
    • v.15 no.1
    • /
    • pp.35-42
    • /
    • 2006
  • Sensor network, that is an infrastructure of ubiquitous computing, consists of a number of sensor nodes of which hardware is very small. The network topology and routing scheme of the network should be determined according to its purpose, and its hardware and software may have to be changed as needed from time to time. Thus, the sensor network simulator being capable of verifying its behavior and estimating performance is required for better design. Sensor network simulators currently existing have been developed for specific hardwares or operating systems, so that they can only be used for such systems and do not provide any means to estimate the amount of power consumption and program execution time which are major issues for system design. In this study, we develop the sensor network simulator that can be used to design and verify various sensor networks without regarding to types of applications or operating systems, and also has the capability of predicting the amount of power consumption and program execution time. For this purpose, the simulator is developed by using machine instruction-level discrete-event simulation scheme. As a result, the simulator can be used to analyze program execution timings and related system behaviors in the actual sensor nodes in detail. Instruction traces used as workload for simulations are executable images produced by the cross-compiler for ATmega128L microcontroller.

  • PDF

Development of Steam Cleaning Technique to Improve Removal Efficiency of Membrane Fouling Matter in Water Treatment Process Using Ceramic Membrane (정수처리용 세라믹 분리막의 막오염 물질의 제거 효율 향상을 위한 스팀세정 기법 개발)

  • Kang, Joon-Seok;Park, Seo Gyeong;Lee, Jeong Eun;Kang, So Yeon;Lee, Jeong Jun;Quyen, Vo Thi Kim;Kim, Han-Seung
    • Journal of Korean Society of Water Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.99-107
    • /
    • 2018
  • This research has developed a high temperature steam cleaning technology using a ceramic membrane with durability against temperature and pressure conditions. In steam cleaning, steam of $120^{\circ}C$ is injected into the ceramic membrane to induce pyrolysis by the endothermic reaction to remove fouling from the membrane. The water quality of raw water was adjusted to turbidity 10, 25 NTU and DOC 2.5 mg/L, and the membrane was uniformly fouled by constant pressure operation at 100, 200, and 300 kPa. Physical backwashing was performed with water and air at a pressure of 500 kPa and steam at $120^{\circ}C$ was injected for 0 to 5 minutes. As the turbidity concentration and the operating pressure increased, the flux decreased by 0.7 to 14.4%. It is confirmed that 10.7 to 53.8% recovery is possible than physical cleaning at the injection of steam for 3 minutes, so it is considered that the steam cleaning of the ceramic membrane is effective. Compared with CEB after NaOCl (300 mg/L) filtration at 25 NTU and 300 kPa of turbidity, the steam cleaning result for 3 minutes was similar to 46.7% of CEB for 3 hours. It has been confirmed that steam cleaning is suitable for a ceramic membrane having excellent heat resistance against high temperature. It was considered to have better cleaning efficiency as compared with general physical backwashing.

Effects of Dissolved Compounds in Groundwater on TCE Degradations Reaction by Nanoscale Zero-Valent Iron (나노영가철의 TCE 분해반응 시 지하수 용존물질의 영향)

  • Kim, Tae-Ho;Kim, Hong-Seok;Lee, Jin-Yong;Cheon, Jeong-Yong;Lee, Kang-Kun;Hwang, In-Seong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.6
    • /
    • pp.413-419
    • /
    • 2011
  • Nanoscale zero-valent iron (NZVI) particles were tested as remediation media for groundwater contaminated by organic pollutants (e.g., TCE, trichloroethylene). The contaminated groundwater contained anions ($NO_3^-$, $Cl^-$, $SO_4^{2-}$, and $HCO_3^-$) and natural organic matter (NOM). Treatability of commercial NZVI particles (NANOFER 25, Nanoiron, Czech) was tested by using a synthetic groundwater and the field groundwater samples. More than 95% of 1.8 mM TCE was removed within 20 hours with a NZVI dosage of 25 g/L ($k=0.15hr^{-1}$). Repetitive degradation experiments revealed that the removal capacity of NANOFER 25 was 0.19 mmole TCE/g NZVI. TCE degradation reactions were not substantially affected by the presence of each anion with concentrations as high as 100 times the average field concentrations. However, when the four anions ($NO_3^-$, $Cl^-$, $SO_4^{2-}$, $HCO_3^-$) were present simultaneously. the degradation reactivity and removal capacity were decreased by 60% ($k=0.069hr^{-1}$) and 10%, respectively. The k value of TCE degradation in the presence of NZVI (25 g/L) with dissovled organic carbon of 2.5 mg/L was also decreased by 84% ($k=0.025hr^{-1}$). In the experiments with the field groundwater, more than 90% of $1.8{\mu}M$ TCE, which is the concentration of TCE at the source zone, was removed within 10 hours with a NANOFER 25 dosage of 25 g/L. The results imply that the contaminated groundwater can effectively be treated by NANOFER 25 with more information on the hydrogeology of the site.

Characteristics of Natural Arsenic Contamination in Groundwater and Its Occurrences (자연적 지하수 비소오염의 국내외 산출특성)

  • Ahn Joo Sung;Ko Kyung-Seok;Lee Jin-Soo;Kim Ju-Yong
    • Economic and Environmental Geology
    • /
    • v.38 no.5 s.174
    • /
    • pp.547-561
    • /
    • 2005
  • General characteristics of groundwater contamination by As were reviewed with several recent researches, and its occurrence in groundwater of Korea was investigated based on a ffw previous studies and a groundwater quality survey in Nonsan and Geumsan areas. In Bangladesh, which has been known as the most serious arsenic calamity country, about $28\%$ of the shallow groundwaters exceeded the Bangladesh drinking water standard, $50{\mu}g/L$, and it was estimated that about 28 million people were exposed to concentrations greater than the standard. Groundwater was characterized by circum-neutral pH with a moderate to strong reducing conditions. Low concentrations of $SO_4^{2-}$ and $NO_3^-$, and high contents of dissolved organic carbon (DOC) and $NH_4^+$ were typical chemical characteristics. Total As concentrations were enriched in the Holocene alluvial aquifers with a dominance of As(III) species. It was generally agreed that reductive dissolution of Fe oxyhydroxides was the main mechanism for the release of As into groundwater coupling with the presence of organic matters and microbial activities as principal factors. A new model has also been suggested to explain how arsenic can naturally contaminate groundwaters far from the ultimate source with transport of As by active tectonic uplift and glaciatiion during Pleistocene, chemical weathering and deposition, and microbial reaction processes. In Korea, it has not been reported to be so serious As contamination, and from the national groundwater quality monitoring survey, only about $1\%$ of grounwaters have concentrations higher than $10{\mu}g/:L.$ However, it was revealed that $19.3\%$ of mineral waters, and $7\%$ of tube-well waters from Nonsan and Geumsan areas contained As concentrations above $10{\mu}g/:L.$. Also, percentages exceeding this value during detailed groundwater quality surveys were $36\%\;and\;22\%$ from Jeonnam and Ulsan areas, respectively, indicating As enrichment possibly by geological factors and local mineralization. Further systematic researches need to proceed in areas potential to As contamination such as mineralized, metasedimentary rock-based, alluvial, and acid sulfate soil areas. Prior to that, it is required to understand various geochemical and microbial processes, and groundwater flow characteristics affecting the behavior of As.

Development of Sensor Network Simulator using Machine Instruction-level Discrete-Event Simulation (기계명령어-레벨의 이산-사건 시뮬레이션을 이용한 센서 네트워크 시뮬레이터 개발)

  • Jung Yong-Doc;Kim Bang-Hyun;Kim Tae-Kyu;Kim Jong-Hyun
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2005.11a
    • /
    • pp.769-771
    • /
    • 2005
  • 유비쿼터스 컴퓨팅의 기반 설비인 센서 네트워크는 많은 수의 센서 노드들로 구성되며, 각 센서 노드의 하드웨어는 매우 작은 규모이다. 또한 최소한의 전력 소모를 위하여 센서 노드들은 동적으로 재구성되며, 노드들 간의 통신은 무선 네트워크를 통하여 이루어진다. 센서 네트워크는 구축 목적에 따라 네트워크 토폴로지 및 라우팅 방식이 결정되어야 하고, 이와 더불어 센서 노드의 하드웨어와 소프트웨어도 필요에 따라 다양하게 변경되어야 한다. 따라서 센서 네트워즈가 구현되기 전에 시스템 동작과 성능을 예측할 수 있고 소프트웨어 개발 환경도 제공해주는 시뮬레이터가 사용 가능하다면, 시스템 개발 기간을 크게 단축시킬 수 있을 것이다. 기존의 센서 네트워크 시뮬레이터들은 특별한 응용을 위한 특정 기반의 하드웨어와 운영체제에 국한되어 개발되었기 때문에 다양한 센서 네트워크 환경을 지원하기에는 한계가 있으며, 센서 네트워크 설계상의 주요 요소인 전력 소모량 분석이 포함되지 않았다. 따라서 본 연구에서는 특정한 응용이나 운영체제에 제한을 받지 않으면서 다양하게 센서 네트워크 환경을 설계 및 검증할 수 있고 전력 소모량 추정도 가능한 시뮬레이터를 개발하는 것을 목표로 하였다. 본 연구에서 개발한 시뮬레이터는 기계명령어-레일(machine instruction-level)의 이산-사건 시뮬레이션(discrete-event simulation) 기법을 이용함으로써 실제 센서 노드의 프로그램 실행 및 관련 동작들을 세부적으로 예측하는 데 사용될 수 있도록 하였다. 시뮬레이션의 작업부하(Workload)인 명령어 트레이스(instruction trace)로는 ATmega128L 마이크로컨트롤러용으로 크로스 컴파일된 인텔 헥스-레코드 형식(.hex) 또는 S-레코드 형식(.srec)의 파일을 사용한다.들을 해결하고자 프라이버시보호에 새로운 키 생성 방법을 통한 강력한 프로토콜을 제안 한다.하였으나 사료효율은 증진시켰으며, 후자(사양, 사료)와의 상호작용은 나타나지 않았다. 이상의 결과는 거세비육돈에서 1) androgen과 estrogen은 공히 자발적인 사료섭취와 등지방 침적을 억제하고 IGF-I 분비를 증가시키며, 2) 성선스테로이드호르몬의 이 같은 성장에 미치는 효과의 일부는 IGF-I을 통해 매개될 수도 있을을 시사한다. 약 $70 {\~} 90\%$의 phenoxyethanol이 유상에 존재하였다. 또한, 미생물에 대한 항균력도 phenoxyethanol이 수상에 많이 존재할수록 증가하는 경향을 나타내었다. 따라서, 제형 내 oil tomposition을 변화시킴으로써 phenoxyethanol의 사용량을 줄일 수 있을 뿐만 아니라, 피부 투과를 감소시켜 보다 피부 자극이 적은 저자극 방부시스템 개발이 가능하리라 보여 진다. 첨가하여 제조한 curd yoghurt는 저장성과 관능적인 면에서 우수한 상품적 가치가 인정되는 새로운 기능성 신제품의 개발에 기여할 수 있을 것으로 사료되었다. 여자의 경우 0.8이상이 되어서 심혈관계 질환의 위험 범위에 속하는 수준이었다. 삼두근의 두겹 두께는 남녀 각각 $20.2\pm8.58cm,\;22.2\pm4.40mm$으로 남녀간에 유의한 차이는 없었다. 조사대상자의 식습관 상태는 전체 대상자의 $84.4\%$가 대부분이 하루 세끼 식사를 규칙적으로 하고 있었으며 식사속도는 허겁지겁 빨리 섭취하는 경우가 남자는 $31.0\%$, 여자는 $21.4\%$로 나타났고 이들을 제외한 나머지 사람들은 보통 속도 혹은 충분한 시간을 가지고 식사를 하였

  • PDF

Study on Mercury Contamination in Multimedia Environment in Lake So-Yang (소양호 다중매체 내 수은오염실태 조사)

  • Park, Sang-Young;Yoo, Seong;Shin, Hyung-Cheol;Kim, Seong-Rak;Kim, Pyung-Rae;Ahn, Myung-Chan;Han, Young-Ji
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.3
    • /
    • pp.202-211
    • /
    • 2011
  • In this study the seasonal and spatial pattern of mercury (Hg) concentrations in multimedia environments were investigated in Lake So-Yang. Total mercury (TM) in water column greatly enhanced as turbidity and particulate organic carbon (POC) increased due to the severe runoff, suggesting that most of Hg existed as particulate Hg in Lake Soyang. We also collected 22 species of fish in Lake Soyang and Han River, and the average total mercury in fish was 0.073 ppm, lower than both Korean (0.5 ppm) and EPA criteria (0.3 ppm). However when considering the amount of fish intake for Korean the Hg criterion in fish must be more stringent than current value, and the advisory for fish consumption should be made. Hg in fish considerably varied with sampling sites, having the highest in the upper region (Yang-gu) and the lowest in downstream (Han River). This spatial variation was possibly derived by "bloom dilution" associated with high phosphorus loading or elevated DOC concentrations, or both. Total mercury in sediment varied from 69.9 to $98.3{\mu}g/kg$, which was relatively lower than those measured in Voyageurs National Park in Minnesota in USA ($102{\sim}364{\mu}g/kg$).

Application of coagulation pretreatment for enhancing the performance of ceramic membrane filtration (세라믹 막여과의 성능향상을 위한 응집 전처리의 적용)

  • Kang, Joon-Seok;Song, Jiyoung;Park, Seogyeong;Jeong, Ahyoung;Lee, Jeong-Jun;Seo, Inseok;Chae, Seonha;Kim, Seongsu;Kim, Han-Seung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.6
    • /
    • pp.501-510
    • /
    • 2017
  • In this study, it is estimated that ceramic membrane process which can operate stably in harsh conditions replacing existing organic membrane connected with coagulation, sedimentation etc.. Jar-test was conducted by using artificial raw water containing kaolin and humic acid. It was observed that coagulant (A-PAC, 10.6%) 4mg/l is the optimal dose. As a results of evaluation of membrane single filtration process (A), coagulation-membrane filtration process (B) and coagulation-sedimentation-membrane filtration process (C), TMP variation is stable regardless of in Flux $2m^3/m^2{\cdot}day$. But in Flux $5m^3/m^2{\cdot}day$, it show change of 1-89.3 kpa by process. TMP of process (B) and (C) is increased 11.8, 0.6 kpa each. But, the (A) showed the greatest change of TMP. When evaluate (A) and (C) in Flux $10m^3/m^2{\cdot}day$, TMP of (A) stopped operation being exceeded 120 kpa in 20 minutes. On the other hand, TMP of (C) is increased only 3 kpa in 120 minutes. Through this, membrane filtration process can be operated stably by using the linkage between the pretreatment process and the ceramic membrane filtration process. Turbidity of treated water remained under 0.1 NTU regardless of flux condition and DOC and $UV_{254}$ showed a removal rate of 65-85%, 95% more each at process connected with pretreatment. Physical cleaning was carried out using water and air of 500kpa to show the recovery of pollutants formed on membrane surface by filtration. In (A) process, TMP has increased rapidly and decreased the recovery by physical cleaning as the flux rises. This means that contamination on membrane surface is irreversible fouling difficult to recover by using physical cleaning. Process (B) and (C) are observed high recovery rate of 60% more in high flux and especially recovery rate of process (B) is the highest at 95.8%. This can be judged that the coagulation flocs in the raw water formed cake layer with irreversible fouling and are favorable to physical cleaning. As a result of estimation, observe that ceramic membrane filtration connected with pretreatment improves efficiency of filtration and recovery rate of physical cleaning. And ceramic membrane which is possible to operate in the higher flux than organic membrane can be reduce the area of water purification facilities and secure a stable quantity of water by connecting the ceramic membrane with pretreatment process.