• Title/Summary/Keyword: L-C filter

Search Result 278, Processing Time 0.022 seconds

A study on the Design of a High pass filter using single FTFN (한 개의 FTFN을 이용한 고역통과 필터의 설계)

  • 이영훈
    • Journal of the Korea Society of Computer and Information
    • /
    • v.7 no.3
    • /
    • pp.56-59
    • /
    • 2002
  • In this study, new serial and parallel resistor and capacitor-frequency-dependent negative resistance configurations are implemented that use one plus type four-terminal floating nullor(FTFN) and three passive components. The values of simulated elements can be orthogonally adjusted without any matching condition. High pass filter designed with this FTFN and AD844. Computer simulation was performed using the AD844 macro model by HSPICE. Simulated results agree well with theoretical values.

  • PDF

The Filter Membrane Culture Procedure with Feeder Cells in Rice Protoplast Culture (Filter membrane과 feeder세포를 이용한 벼의 원형질체 배양)

  • LEE, Sung-Ho;SHON, Young Geol;Lee, Soo In;DAVEY Micheal R.;COCKING Edward C.;CHO, Moo Je
    • Korean Journal of Plant Tissue Culture
    • /
    • v.24 no.5
    • /
    • pp.295-303
    • /
    • 1997
  • To investigate the response on feeder cell cultures, protoplasts isolated from cell suspensions initiated from mature seed scutellum-derived callus of the Japonica rice variety Taipei 309, were cultured on filter membranes under various conditions. The effects of various factors, such as gelling agents, feeder cell and protoplast densities, species of feeder cells and heat shock treatment, have been investigated to improve protoplast plating efficiencies on filter membranes. Maximum protoplast plating efficiencies were obtained when protoplasts were cultured on KPR medium semi-solidified with Sea Plaque agarose at a density of $5\;\times\;10^{5}\;ml^{-1}$ protoplasts in the presence of Lolium multiflorum as feeder cells (0.5 ml pcv per 10 ml of protoplast culture medium). Pre-culture heat shock treatments for 1 min. and 5 min. to the protoplasts did not give any appreciable increase on the plating efficiency of protoplasts in the presence of feeder cells. Maltose-supplemented medium was superior for plant regeneration from protoplast-derived colonies compared with medium containing only sucrose. The plants were transferred to the glasshouse, flowered and were fertile.

  • PDF

Adoptive IIR Fillers for Active Noise Control (능동소음제어를 위한 적용 IIR 필터)

  • 남현도
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.5
    • /
    • pp.112-118
    • /
    • 2002
  • The adaptive m filters is more effective than m filters when acoustic feedback exists, in which cause an order of a FIR filter must be very large if some of poles of the ideal control filter are near the unit circle. But the IIR filters may have stability problems especially when the adaptive algorithm is not converged. In this paper, a stabilizing procedure for adaptive IIR filters is proposed. In the beginning of the ANC system, it improve a stability by pulling the poles of the IIR filter to the center of the unit circle, and it returns the poles to their original positions after the filter converge. Computer simulations and experiments are performed to show the effectiveness of proposed schemes.

Stacked LTCC Band-Pass Filter for IEEE 802.11a (IEEE 802.11a용 적층형 LTCC 대역통과 여파기)

  • Lee Yun-Bok;Kim Ho-Yong;Lee Hong-Min
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.2 s.93
    • /
    • pp.154-160
    • /
    • 2005
  • Microwave Otters are essential device in modem wireless systems. A compact dimension BPF(Band-pass Filter) for IEEE 802.11a WLAN service is realized using LTCC multi-layer process. To extrude 2-stage band-pass equivalent circuit, band-pass and J-inverter transform applied to Chebyshev low-pass prototype filter. Because parallel L-C resonator is complicate and hard to control the inductor characteristics in high frequency, the shorted $\lambda/4$ stripline is selected for the resonator structure. The passive element is located in the different layers connected by conventional via structure and isolated by inner GND. The dimension of fabricated stacked band-pass filter which is composed of six layers, is $2.51\times2.27\times1.02\;mm^3$. The measured filter characteristics show the insertion loss of -2.25 dB, half-power bandwidth of 220 MHz, attenuation at 5.7 GHz of -32.25 dB and group delay of 0.9 ns at 5.25 GHz.

Biofilm Processes for Volume Decrease in Recirculating Water Treatment Systems for Aquaculture

  • Kim Jeong-Sook;Yoon Gil-Ha;Ghim See-Jun;Kang Lim-Seok;Lee Byung-Hun
    • Fisheries and Aquatic Sciences
    • /
    • v.1 no.2
    • /
    • pp.242-249
    • /
    • 1998
  • The engineering aspect of water treatment processes in the recirculating aquaculture system was studied. To recycle the water in the aquaculture system, a wastewater treatment process was required to maintain high water quality for the growth and health of the cultured fish. In this study, three different biofilm processes were used to reduce the concentration of organic matters and ammonia from the recirculating water - two phase fluidized bed, three phase fluidized bed, and trickling filter. The objectives of this research were to evaluate the optimum treatment conditions of the biofilm processes for the recirculating aquaculture system, and thereby reduce the volume of biofilm processes, which are commonly used for the recycle water treatment processes for aquaculture. The result of this study showed that the removal efficiency of organic matters by trickling filter was found to be lower than that of the fluidized bed. In the trickling filter system, anthracite showed better organic removal efficiency than crushed stone as a media. In the two phase fluidized bed, the maximum removal efficiency of either organics or ammonia was obtained when both the packing rate of media was maintained to $40\%$ of total reactor depth excepting sediment zone and the bed expansion rate was maintained to $100\%$. When 100 tilapia (Oreochromis niloticus) of each average 200g was reared, the pollutant production rate was 0.07g $NH_4\;^+-N/kg$ fish/day and 0.06g P04-3-P/kg fish/day, and sludge production rate was 0.39 g SS/kg fish/day. In the two phase and three phase fluidized bed, the volume of water treatment tank could be calculated from an empirical equation by using the relationship between the influent COD to $NH_4\;^+-N$ ratio (C/N, -), media concentration (Cm, g/L), influent ammonia nitrogen concentration (Ni, mg/L), effluent ammonia nitrogen concentration (Ne, mg/L), bed expansion rate $(E,\;\%)$, and influent flowrate $(Q,\;m^3/hr)$. The empirical equation from this study is $$V_2\;=\;10^{3.1279}\;C/N^{3.5461}\;C_m\;^{-3.7473}\;N_i\;^{4.6477}\;E^{0.0326}\;N_e\;^{-0..8849}\;Q\;(Two\;Phase\;FB) V_3\;=\;10^{11.7507}\;C/N^{-1.2330}\;C_m\;^{-6.5715}\;N_i\;^{1.5091}\;N_e\;^{-1.8489}\;Q (Three\;Phase\;FB)$$

  • PDF

A Study on the Estimation Technique of Frequency in the Power System using FIR Filter (FIR 필터를 이용한 전력계통 주파수 추정기법에 관한 연구)

  • Nam, S.B.;Lee, H.G.;Park, C.W.;Shin, M.C.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07e
    • /
    • pp.80-85
    • /
    • 2001
  • Frequency is an important operating parameter of a power system. Frequency of a power system remains constant if sum of all the loads plus losses equals total generation in the system. However, the frequency starts to decrease if total generation is less than the sum of loads and tosses. On the other hand, the system frequency increases if total generation exceeds the sum of loads and losses. Electric power systems sustain transient frequency swings whenever the balance between generation and load does not no longer hold. To cope with this Constraints, it requires an accurate and high speedy frequency deviation estimation technique and suitable adjustment to obtain the power system energy balance. The fundamental frequency component of 3-phase signal is first extracted by using an algorithm based on FIR(finite duration impulse response) filter, a phase angle of a voltage. The rate change of the phase angle is used for estimation and speed in its process. Also, to confirm the validity of the proposed algorithm, the simulation results obtained by using EMTP(electro magnetic transients program) are shown.

  • PDF

Synthesis, Molecular and Microstructural Study of Poly-N-Vinylpyrrolidone Oximo-L-Valyl-Siliconate with IR, 1H-NMR and SEM

  • Singh, Man;Padmaja, G. Vani
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.7
    • /
    • pp.1869-1874
    • /
    • 2010
  • By reducing PVP with $H_2NOH$.HCl and NaOH 2:2:1 mass ratios in aqueous ethanol, poly-N-vinyl pyrrolidone oxime [PVPO] was prepared with 92% yield. Applying the sol-gel concept, orthosilicic acid [OSA] was made by hydrolyzing TEOS with ethanol in 1:0.5 molar ratios using 1 N KOH aqueous solution as a catalyst. The OSA + PVPO + $_L$-Valine ($\alpha$-amino acid) were mixed with pure ethanolic medium in 1:2:2 mass ratios and refluxed at $78^{\circ}C$ and 6 pH for 6.5 h. A white residue of poly-N-vinyl pyrrolidone oximo-L-valyl-siliconate [POVS] appeared after 5 h. The heating of reaction mixture was stopped and the contents were brought to NTP. The residue formation of POVS was intensified with lowering a temperature and completely solidified within 5 h, was filtered using a vacuum pump with Whatmann filter paper no. 42. The residue of POVS was washed several times with 20% aqueous cold ethanolic solution and dried in vacuum chamber at $25^{\circ}C$ for 24 h. The MP was noted above $350^{\circ}C$. Structural and internal morphology were analyzed with IR and $^1H$-NMR, and SEM respectively. A drug loading and transporting ability of the POVS in water and at pH = 5 and 8 was determined chromatographically.

A Design Method of Fuel Pump System Using Adaptive control (적응제어를 이용한 연료펌프 시스템의 설계방법)

  • 김원규;박종국
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.22 no.5
    • /
    • pp.75-82
    • /
    • 1985
  • The fuel pump system is developed with the Model Reference Adaptive Control (M.R.A.C.) algorithm based on the Weight Least Square (W.L.S.) algorithm for the parameter Identification and the one step ahead dead-beat control with the reference model. The value of some parameters as the sampling period 7, the weighting coefficient L, and the State Variable Filter (5.V,F.) coefficient f which a(fects the system performance are selected through computer simulation. For the variation of the plante dynamics rspecially due to the change of the fuel viscosity with the ambient temperature condition, the adaptability of the control system is studied in the case of regulation and tracking.

  • PDF

Image and Exposure Dose in Accordance with Radiation Quality on Plain Chest Radiography (흉부촬영(胸部撮影)에서 증감지(增感紙)-필름계의 선질변화(線質變化)에 따른 감도(感度)와 화질에 관(關)한 연구(硏究))

  • Kim, Jung-Min;Kim, Dong-Huan;Hayashi, Taro;Ishida, Yuji;Maeda, Mika;Sakura, Tatsuya
    • Journal of radiological science and technology
    • /
    • v.15 no.1
    • /
    • pp.65-78
    • /
    • 1992
  • Routine chest radiography is generally imaged by high voltage technique but some radiological technologists use low voltage for imaging. High voltage is usually said between $120\;kV{\sim}140\;kV$. Some RTs like using heavy filtration but others seldom like using it. However which is better for use calcium tungustate film screen system or ortho system and high contrast film or wide latitude c-type film for the exculusive use of chest radiography. We could not make a decision which is ideal method for use. In my opinion any method is not always exellent for chest radiography. In my experiments that I had at Kaken hospital in Japan last year I expect to keep the balance between image quality and diagnostic range and to reduce radiation dose for patients. My experiments are as follows. 1. We have looked into system characteristics(speed and contrast) in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems(BX3+CRONEX4, SRO750+MGH, SRO750+MGL). 2. We have looked into skin dose and film dose with same D=1.8 lung field density in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems. 3. We have compared with the evaluation between correlation of physical image quality(MTF) and optical diagnostic capability. Result are follows. 1. Speed of BX3+CRONEX4 became higher in accodance with kVp and thickness of filter but speed of ortho system was not as like regular system. Thicker filter diminished the speed over 100 kV range in SRO750+MGL. In case of SRO750+MGH speed of 1/16VL filter was looked into lower than speed of 1/4VL filter. Sensitivity of ortho system depends on tube voltage and added filter. 2. Skin dose has been detected $225\;{\mu}Gy{\sim}66\;{\mu}Gy$ in BX3+CRONEX4 from 80 kV, no filter to 140 kV, 1/16VL filter. SRO750+MGH could reduce the patient dose $1/2{\sim}1/3$ level in comparison to that of BX3+CRONEX4. 3. The higher kV was the worse MTF became the thicker filter was the worse MTF became too. MTF of BX3+CRONEX4 was detected better than MTF of SRO750+MGH but SRO750+MGH's optical detectability of small lesion in lung field came out better than that of BX3+CRONEX4. Conclusion Recently routine chest radiography is generally imaged by high voltage but it seems to be there are some questions in using of film screen combination. In high voltage chest radiography the subject contrast will come down that means latitude become wider. In this case if we select the low contrast film screen system(C or L type) the film contrast will fall down extremly and detectability of small lesion will be deteriorated. Wide latitude C, L type film has a merit of high detectability on mediastinum. Furthermore high contrast film screen system has the advantage to keep the high contrast in low density region as like mediastinum and heart shadow. Therefore in low subject contrast high voltage chest radiography we would rather choose the high contrast film screen system(H type) I think. From a view point of patient dose detectability of mediastinum and lung field. The optimum technical facter was found out 120 kV, 1/16VL filter : BX3+CRONEX4, 140 kV, 1/4VL filter : SRO750+MGH, 100 kV, 1/4VL filter : SRO750+MGL.

  • PDF