• Title/Summary/Keyword: L-형 평판

Search Result 70, Processing Time 0.025 seconds

Combined Convective Heat Transfer from Vertical Parallel Plates (수직 평행평판에서의 혼합대류 열전달)

  • 양성환;권순석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.2
    • /
    • pp.299-306
    • /
    • 1989
  • The combined convective heat transfer from vertical parallel plates with constant temperature has been studied by numerical method. The governing equations for the system are solved by the finite difference method and successive over relaxation scheme for Re$_{L}$ = 50 - 500, Gr = 10$^{4}$, Pr = 0.7. Results for various plate spacings and plate lengths are as follows ; For various plate spacings, the mean Nusselt number increases and then decreases as the dimensionless plate spacing increases. The optimum plate spacing for maximum mean Nusselt number decreases with increasing Reynolds number and can be expressed as a function of Reynolds number. For various plate lengths, the mean plate Nudest number increases as the dimensionless plate length decreases and Reynolds number increases.

hp-Version of the Finite Element Analysis for Reissner-Mindlin Plates (Reissner-Mindlin 평판의 hp-Version 유한요소해석)

  • Woo, Kwang Sung;Lee, Gee Doug;Ko, Man Gi
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.2
    • /
    • pp.151-160
    • /
    • 1993
  • This paper is concerned with formulations of the hierarchical $C^{\circ}$-plate element on the basis of Reissner-Mindlin plate theory. On reason for the development of the aforementioned element based on Integrals of Legendre shape functions is that it is still difficult to construct elements based on h-version concepts which are accurate and stable against the shear locking effects. An adaptive mesh refinement and selective p-distribution of the polynomial degree using hp-version of the finite element method are proposed to verify the superior convergence and algorithmic efficiency with the help of the simply supported L-shaped plate problems.

  • PDF

The Selective p-Distribution for Adaptive Refinement of L-Shaped Plates Subiected to Bending (휨을 받는 L-형 평판의 적응적 세분화를 위한 선택적 p-분배)

  • Woo, Kwang-Sung;Jo, Jun-Hyung;Lee, Seung-Joon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.5
    • /
    • pp.533-541
    • /
    • 2007
  • The Zienkiewicz-Zhu(Z/Z) error estimate is slightly modified for the hierarchical p-refinement, and is then applied to L-shaped plates subjected to bending to demonstrate its effectiveness. An adaptive procedure in finite element analysis is presented by p-refinement of meshes in conjunction with a posteriori error estimator that is based on the superconvergent patch recovery(SPR) technique. The modified Z/Z error estimate p-refinement is different from the conventional approach because the high order shape functions based on integrals of Legendre polynomials are used to interpolate displacements within an element, on the other hand, the same order of basis function based on Pascal's triangle tree is also used to interpolate recovered stresses. The least-square method is used to fit a polynomial to the stresses computed at the sampling points. The strategy of finding a nearly optimal distribution of polynomial degrees on a fixed finite element mesh is discussed such that a particular element has to be refined automatically to obtain an acceptable level of accuracy by increasing p-levels non-uniformly or selectively. It is noted that the error decreases rapidly with an increase in the number of degrees of freedom and the sequences of p-distributions obtained by the proposed error indicator closely follow the optimal trajectory.

Analysis of Impedance matching circuit for Planar-Type Inductively Coupled Plasma Device (평판형 유도 결합 플라즈마 장치에 대한 Alternate type Impedance matching 회로 분석)

  • Lee, Jong-Kyu;Kwon, D.C.;Yu, D.H.;Yoon, N.S.;Kim, J.H.;Shin, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1933-1935
    • /
    • 2004
  • 본 연구에서는 변압기형 플라즈마 전류 모델을 기초로 한 평판형 유도 결합 플라즈마 장치에 대한 회로를 분석하여 임피던스 매칭 특성을 조사하였다. 장치 임피던스는 collisional surface impedance를 기반으로 계산된 플라즈마 임피던스와 안테나 임피던스로 결정된다. 매칭 network에 사용된 회로는 Altcmatc-typc의 회로이고, 매칭 소자인 $C_T$$C_L$은 임피던스 매칭 조건을 이용하여 계산하였다. 완전 매칭의 경우에는 $C_T$$C_L$을 플라즈마 변수들의 함수로 표현하여 의존성을 분석하고, 불완전 매칭의 경우에는 반사파에 대한 반사계수, 반사율을 계산하였다.

  • PDF

Design and Trial Fabrication of Plate-Type Linear Ultrasonic Motor Using L1-B4 Vibration Mode (L1-B4 진동모드를 이용한 평판형 선형 초음파 모터의 설계 및 시제작)

  • 이종섭;정수현;임기조;임태빈;강성택;채홍인
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.10
    • /
    • pp.861-865
    • /
    • 1998
  • A plate-type linear ultrasonic motor using logitudinal and bending multi-vibration mode was designed and fabricated for the application to card-forwarding device. The stator consisted of PZ-PT-PMS piezoelectric ceramic plate and stainless steel. The performances of the motor were measured. As the experimental results, no-load speed of the motor was 0.6m/s when applied voltage was $80\textrm{V}_{rms}$ in resonance frequency. Starting torque was 1.4 mNm and maximum efficiency was 1.2%.

  • PDF

Comparison of Dosimetry Protocols in High Energy Electron Beams (고에너지 전자선에 대한 표준측정법간의 비교)

  • 박성용;서태석;김회남;신동오;지영훈;군수일;이길동;추성실;최보영
    • Progress in Medical Physics
    • /
    • v.9 no.4
    • /
    • pp.267-276
    • /
    • 1998
  • Any detector inserted into a phantom should have such a geometry that it caused as small as possible perturbation of the electron fluence. Plane parallel chambers meet this requirement better than other chambers of configurations. IAEA protocol recommends the use of plane parallel chambers for this reason. However, the cylindrical chambers are widely used for convenient. The purpose of this study is to evaluate the absorbed dose due to the differences of four different dosimetry protocols such as IAEA protocol using cylindrical chamber, TG 21 protocol using cylindrical chamber, Markus protocol using plane parallel chamber, and TG 39 report for the calibration of plane parallel chamber in electron beams. Depth-ionization measurements for the electron beams of nominal energy 6, 9, 12, 15, and 18 MeV from Siemens accelerator with a 10$\times$10 cm$^2$ field size were made using a radiation field analyser with 0.125 cc ion chamber. Dosimetric measurements by IAEA and TG 21 protocol were made with a farmer type ionization chamber in solid water for each electron energy, respectively. Dosimetric measurements by Markus protocol were made with a plane parallel ionization chamber in solid water for each electron energy, respectively. The cavity-gas calibration factor for the plane parallel chamber was obtained with the use of 18 MeV electron beam as guided by TG 39 report. Dosimetric measurements by TG 39 were performed with a plane parallel ionization chamber in solid water for each electron energy, respectively. For all the energies and protocols, measurements were made along the central axis of the distance of 100 cm (SSD = 100 cm) with 10$\times$10 cm$^2$ field size at the depth of d$_{max}$ for each electron beam, respectively. In the case of 18 MeV, the discrepancy of 0.9 % between IAEA and TG 21 was found and the two protocols were agreed within 0.7 % for other energies. In the case of 18 MeV and 6 MeV, the discrepancies of $\pm$ 0.8 % between Markus and TG 39 was found, respectively and the two protocols were agreed within 0.5 % for other energies. Since the discrepancy of 1.6 % between cylindrical and plane parallel chamber was found for 18 MeV, it is suggested to get the calibration factor using other method as guided. by TG 39.9.

  • PDF

Optimum Design of Reputation Slab Induction Heating System using Resonant Inverter (공진형 인버터를 이용한 평판유도가열 시스템의 최적설계)

  • Park, Sang-hoon;Shin, Dae-chul
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.138-139
    • /
    • 2012
  • 본 논문에서는 고주파 공진형 인버터 접속의 가열 코일로부터 비접촉 상태로 전자유도 와전류를 구조물에 가하여 발열하는 공진형 인버터를 이용한 유도가열 방식의 최적설계를 제안하였다. 설계한 시스템 인버터는 스위칭주파수 20[kHz] 대역에서 동작하는 하프-브리지 고주파 직렬 부하 공진형이며 LC공진 설계 시 부하 자체를 L로 설정하여 효율을 최대화 하였다. 또한 유도가열용 인버터에 적용 가능한 스너버회로의 특성분석을 통해 본 시스템의 최적화에 관한 연구를 하였다.

  • PDF

Analysis on the Thermal Performance of Flat-plate Solar Collector for Greenhouse Heating(I) (온실 난방을 위한 평판형 태양집열기의 열적성능 분석)

  • Suh, Won-Myung;Yoon, Yong-Cheol;Lee, Seung-Hwan;Lee, Suk-Gun
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.40 no.6
    • /
    • pp.46-56
    • /
    • 1998
  • This study was performed to investigate thermal performances of two different types of flat-plate solar collector systems; natural circulation system and forced circulation system. Conclusions obtained from this study are summarized as follows; 1) In the natural circulation system, the total heat amounts retrieved by starting recovery soon after sunrise were ranged from 10.28 to 17.20MJ/m$^2$, while the total heat amounts retrieved by starting recovery after sunset were ranged from 5.31 to 10.77MJ/m$^2$. 2) The collector efficiency in natural circulation system were ranged from 51.1% to 54.1% when the collected heat was retrieved after sunrise and were 65.8~78.0% when the collected heat was retrieved soon after sunset. 3) According to the regression analysis between fluid flow rates and fluid temperature difference at inlet and outlet of collector pipe, there was high regressive corelations with regression coefficient, r, of 0.982. 4) The collector efficiencies estimated for forced circulation system were 73.1~88.6%, and 78.4~94.8%, and 64.2%~74.5%, respectively when fluid circulation rates were 4.2 l/min, and 7.0 l/min, respectively.

  • PDF

High Throughput Screening and Directed Evolution of Tyrosine Phenol-Lyase (Tyrosine Phenol-Lyase의 고속탐색기술 개발 및 방향성 분자진화)

  • Choi Su-Lim;Rha Eu-Gene;Kim Do-Young;Song Jae-Jun;Hong Seung-Pyo;Sung Moon-Hee;Lee Seung-Goo
    • Microbiology and Biotechnology Letters
    • /
    • v.34 no.1
    • /
    • pp.58-62
    • /
    • 2006
  • Rapid assay of enzyme is a primary requirement for successful application of directed evolution technology. Halo generation on a turbid plate would be a method of choice for high throughput screening of enzymes in this context. Here we report a new approach to prepare turbid plates, by controlling the crystallization of tyrosine to form needle-like particles. In the presence of tyrosine phenol-lyase (TPL), the needle-like tyrosine crystals were converted to soluble phenol rapidly than the usual rectangular tyrosine crystals. When an error-prone PCR library of Citrobacter freundii TPL was spread on the turbid plate, approximately 10% of the colonies displayed recognizable halos after 24 hours of incubation at $37^{\circ}C$. Representative positives from the turbid plates were transferred to LB-medium in 96-wellplates, cultivated overnight, and assayed for the enzyme activity with L-tyrosine as the substrate. The assay results were approximated to be proportional to the halo size on turbid plates, suggesting the screening system is directly applicable to the directed evolution of TPL. Actually, two best mutants on the turbid plates were identified to be $2{\sim}2.5$ and 1.5-fold improved in the activity.