• Title/Summary/Keyword: L-필터

Search Result 449, Processing Time 0.026 seconds

Analysis of fMRI Signal Using Independent Component Analysis (Independent Component Analysis를 이용한 fMRI신호 분석)

  • 문찬홍;나동규;박현욱;유재욱;이은정;변홍식
    • Investigative Magnetic Resonance Imaging
    • /
    • v.3 no.2
    • /
    • pp.188-195
    • /
    • 1999
  • The fMRI signals are composed of many various signals. It is very difficult to find the accurate parameter for the model of fMRI signal containing only neural activity, though we may estimating the signal patterns by the modeling of several signal components. Besides the nose by the physiologic motion, the motion of object and noise of MR instruments make it more difficult to analyze signals of fMRI. Therefore, it is not easy to select an accurate reference data that can accurately reflect neural activity, and the method of an analysis of various signal patterns containing the information of neural activity is an issue of the post-processing methods for fMRI. In the present study, fMRI data was analyzed with the Independent Component Analysis(ICA) method that doesn't need a priori-knowledge or reference data. ICA can be more effective over the analytic method using cross-correlation analysis and can separate the signal patterns of the signals with delayed response or motion related components. The Principal component Analysis (PCA) threshold, wavelet spatial filtering and analysis of a part of whole images can be used for the reduction of the freedom of data before ICA analysis, and these preceding analyses may be useful for a more effective analysis. As a result, ICA method will be effective for the degree of freedom of the data.

  • PDF

Gaze Tracking System Using Feature Points of Pupil and Glints Center (동공과 글린트의 특징점 관계를 이용한 시선 추적 시스템)

  • Park Jin-Woo;Kwon Yong-Moo;Sohn Kwang-Hoon
    • Journal of Broadcast Engineering
    • /
    • v.11 no.1 s.30
    • /
    • pp.80-90
    • /
    • 2006
  • A simple 2D gaze tracking method using single camera and Purkinje image is proposed. This method employs single camera with infrared filter to capture one eye and two infrared light sources to make reflection points for estimating corresponding gaze point on the screen from user's eyes. Single camera, infrared light sources and user's head can be slightly moved. Thus, it renders simple and flexible system without using any inconvenient fixed equipments or assuming fixed head. The system also includes a simple and accurate personal calibration procedure. Before using the system, each user only has to stare at two target points for a few seconds so that the system can initiate user's individual factors of estimating algorithm. The proposed system has been developed to work in real-time providing over 10 frames per second with XGA $(1024{\times}768)$ resolution. The test results of nine objects of three subjects show that the system is achieving an average estimation error less than I degree.

Ballast water Treatment using a Multistage Filter (다단 디스크 여과장치를 이용한 선박 밸러스트수 처리)

  • Park, Sang-Ho;Lim, Jae-Dong;Kim, In-Soo
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2006.05a
    • /
    • pp.79-83
    • /
    • 2006
  • Displayed result that handle particle contaminant and hydrospace organism included in number of ballast that is happened in ship using automatic bade washing filter. Reason that remove first contaminant that is included in number of ballast is that heighten processing effect of after processing process. of the filter. Another advantage is to drop off the solids with controlling revolution of drum screen in pretreatment filtration process. The fact that it is easy to attach and detach a several type of screen for getting the expected water quality is another advantage. Filter rotation speed at 1.0rpm is filter resistance 3.0bar and 3.0rpm is filter resistance 2.8bar. Filter out impurities from ballast water over 6.0rpm is filter resistance 26bar and 10rpm is filter resistance 2.5bar. Filtration system removal aquatic organism over $80{\mu}m$ in ballast water. This study shows that the filtration treatment system has a potential for the treatment of ballast water.

  • PDF

NO Formation in Partially Premixed Counterflow Flames;Comparison of Computed and PLIF Results (부분예혼합 대향류 화염에서의 NO 생성특징;수치해석 및 PLIF 결과 비교)

  • Lee, Woong-Jae;Lee, Won-Nam;Cha, Min-Suk;Song, Young-Hoon
    • 한국연소학회:학술대회논문집
    • /
    • 2000.05a
    • /
    • pp.57-66
    • /
    • 2000
  • OH radical and NO distributions have been measured in methane/air partially premixed counterflow flames(${\alpha}$=1.0, 0.8, 0.6) using PLIF technique. The results are discussed and compared with the numerical analysis results obtained under the same flame conditions. Measured OH and NO LIF signals agree with the computed concentration distributions. Both numerical and experimental results indicate that the structural change in a flame alters the NO formation characteristics of a partially premixed counterflow flame. The nitrogen dilution also changes flame structure, temperature and OH radical distributions and results in the decreased NO concentrations in a flame. The levels of decrease in NO concentrations, however, depends on the premixedness(${\alpha}$) of a flame. The larger change in the flame structure and NO concentrations have been observed in a premixed flame($\alpha$=1.0), which implies that the premixedness is likely to be a factor in the dilution effect on NO formation of a flame.

  • PDF

Comparison of Cardinal Temperatures of Lettuce Using Bilinear, Parabolic, and Beta Distribution Functions (선형, 쌍곡선과 Beta 함수를 이용한 상추의 주요 온도 비교)

  • Cha, Mi-Kyung;Kim, Chun-Sik;Austin, Jirapa;Cho, Young-Yeol
    • Journal of Bio-Environment Control
    • /
    • v.23 no.1
    • /
    • pp.39-42
    • /
    • 2014
  • The objective of this study was to estimate cardinal temperatures for germination of lettuce (Lactuca sativar L.) using bilinear, parabolic, and beta distribution functions. Seeds of lettuce were germinated in a growth chamber at 7 constant temperatures: 10, 14, 16, 20, 24, 28, and $32^{\circ}C$. Four replicates of 100 seeds were placed on two layers of filter paper in a 9 cm petri-dish. Radicle emergence of 1 mm was scored as germination. The time course of germination was modeled using a logistic function. These minimum, optimum, and maximum temperatures were estimated by regression of the inverse of time to 50% germination rate against the temperature gradient. In bilinear function, minimum, optimum, and maximum temperatures were $7.9^{\circ}C$, $23.3^{\circ}C$, and $28.0^{\circ}C$, respectively. In parabolic function, minimum, optimum, and maximum temperatures were $9.7^{\circ}C$, $19.5^{\circ}C$, and $29.4^{\circ}C$, respectively. In beta distribution function, minimum, optimum, and maximum temperatures were $3.7^{\circ}C$, $20.7^{\circ}C$ and $32.0^{\circ}C$, respectively. Minimum, optimum, and maximum ranges of temperatures were $3.7{\sim}9.7^{\circ}C$, $19.5{\sim}23.3^{\circ}C$, and $28.0{\sim}32.0^{\circ}C$, respectively.

DETERMINATIONS OF ITS ABSOLUTE DIMENSIONS AND DISTANCE BY THE ANALYSES OF LIGHT AND RADIAL-VELOCITY CURVES OF THE CONTACT BINARY - I. V417 Aquilae (접촉쌍성의 광도와 시선속도곡선의 분석에 의한 절대 물리량과 거리의 결정 -1. V417 Aquilae)

  • 이재우;김천휘;이충욱;오규동
    • Journal of Astronomy and Space Sciences
    • /
    • v.21 no.2
    • /
    • pp.73-82
    • /
    • 2004
  • New photometric and spectroscopic solutions of W-type overcontact binary V 417 Aql were obtained by solving the UBV light curves of Samec et al. (1997) and radial-velocity ones of Lu & Rucinski (1999) with the 2003 version of the Wilson-Devinney binary code. In the light curve synthesis the light of a third-body, which Qian (2003) proposed, was considered and obtained about 2.7%, 2.2%, and 0.4% for U, B, and V bandpasses, respectively. The model with third-light is better fitted to eclipse parts than that with no third-light. Absolute dimensions of V417 Aql are determined from our solution as $M_1$= 0.53 $M_{*}$, $M_2$= 1.45 $M_{*}$, $R_1$= 0.84 $R_{*}$, and $R_2$= 1.31 $M_{*}$, and the distance to it is deduced as about 216pc. Our distance is well consistent with that (204pc) derived from Rucinski & Duerbeck's (1997) relation, $M_{v}$ = $M_{v}$(log P, B-V), but is more distant than that (131$\pm$40pc) determined by the Hipparcos trigonometric parallax. The difference may result from the relatively large error of Hipparcos parallax for V 417 Aql.l.

ROCHE MODEL AND ABSOLUTE DIMENSIONS OF THE ECLIPSING BINARY Y CAM WITH A PULSATING COMPONENT (맥동 식쌍성 Y Cam의 ROCHE 모형과 절대 물리량)

  • Lee, J.W.;Kim, C.H.;Kim, S.L.;Youn, J.H.;Kwon, S.G.
    • Journal of Astronomy and Space Sciences
    • /
    • v.19 no.3
    • /
    • pp.187-196
    • /
    • 2002
  • We performed CCD photometric observations of the eclipsing binary Y Cam with a pulsating component, for 16 nights from November 2000 to May 2001 using a V filter attached to the 61-cm reflector at Sobaeksan Optical Astronomy Observatory. Our V light curve and Broglia & Marin's (1974) BV ones were analyzed with Mode 2 for a detached Roche model as well as Model 5 for a semi-detached one in the Wilson-Devinney code. From the analysis, we found the following results: 1) It is hardly discernible from only light curve synthesis which model between the detached and semi-detached ones is a real Roche model of Y Cam. 2) There exist the third light of about 2% and 3% in B and V light curves of Y Cam, respectively. 3) The light curve solution is immune from the light variation due to the pulsation of the primary component of Y cam. However, the detached model rather than the semi-detached one has slightly better fitted to the observations which were get rid of the pulsation effect. 4) The absolute dimensions of Y Cam were calculated for two Roche models.

Preconcentration and Determination of Trace Copper(II) and Lead(II) in Aqueous Solutions by Adsorption on Ca-Alginate Bead (알긴산칼슘 비드 상 흡착에 의한 흔적량 구리(II)와 납(II)의 동시 농축 및 정량)

  • Choi, Jong-Moon;Choi, Sun-Do
    • Journal of the Korean Chemical Society
    • /
    • v.48 no.6
    • /
    • pp.590-598
    • /
    • 2004
  • The preconcentration and determination of trace Cu(II) and Pb(II) on calcium alginate beads in aqueous solution were studied. A calcium alginate beads were prepared by adding an alginic acid to sample solution contained Ca(II). Some following conditions were optimized: the pH of sample solution, amount of alginic acid, and stirring time for effective adsorption; the type and concentration of acid, and sonication time in an ultrasonic vibrator for the perfect de-sorption. A sample solution was prepared with Cu(II) and Pb(II) in DI water. And Ca(II) and ethanol was added into the sample solution. The pH of the final sample solution was controlled with buffer solution. The alginic acid were dispersed in the sample solution by a magnetic stirrer. This mixture was stored in room temperature for 30 min to form a calcium alginate. After the beads were filtered and washed on a membrane filter, the analytes were redissolved from the beads by an ultrasonic vibration of 10 minutes in 1.0M $HNO_3$ solution. The effect of diverse ions on the adsorption of analytes were studied. This procedure was applied for the analysis of two real samples. The recoveries in spiked samples were $90.4{\sim}104.3%$ for analytes.

Filtering & Cridding Algorithms for Multibeam Echo Sounder Data based on Bathymetry (수심에 기반한 멀티빔 음향 측심 필터와 격자 대표값 선정 알고리즘)

  • 박요섭;김학일
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 1999.11a
    • /
    • pp.260-265
    • /
    • 1999
  • 멀티빔 음향측심기(Multibeam Echo Sounder)는 기존의 단빔 음향측심기(Singlebeam Echo Sounder)와 달리 탐사선 진행방향의 수직(Crosstrack)으로 해저면을 주사(Swath)하여, 한 번의 송수신(Ping)으로 다중의 빔 자료 - 수심, 후방산란된 음압(Backscattered Amplitude), 사이드 스캔 소나(Side Scan Sonar) 자료 - 를 취득하는 장비이다. 멀티빔 음향 측심기를 이용한 해저면 탐사의 경우, 수심이 변함에 따라 주사폭(Swath width)이 변화하고, 각 빔의 수평 해상도(Footprint)는 수심과 더불어 빔폭(Beam width)에 의하여 동적으로 변화한다. 멀티빔 음향 측심기는 해저면을 전역탐사 할 수 있을 뿐만 아니라, 연속된 음향 탐사를 통하여 이웃한 핑 사이에 발생하는 전방중첩영역(Endlap)과 이웃 측선(Trackline)을 따라 겹쳐지는 측방중첩영역(Sidelap)의 자료들을 이용하여 멀티 뎀 자료들의 전반적인 정확도 및 신뢰도를 평가할 수 있다. 본 논문은 수로 측량(Hydrographic Survey)에서 사용되는 멀티빔 음향 측심기를 운영하여 얻어진 측심 자료를 처리하는 알고리즘 개발에 관한 연구이다. 본 논문에서는 L3사의 Sea Beam 2100 벌티빔 음향 측심기를 대상으로, 멀티빔의 측심 원리와 해저 지형에 대한 일반적 이해를 통하여 획득된 측심 자료의 통계적 특성을 파악하고, 오측심된 수심 자료를 제거하는 방법을 제안하며, 측심 구간의 대표격자 크기를 결정하는 기준을 제시한다. 또한, 항공원격탐사에서 고도 추정시 사용되고 있는, 평균보간법, 가중평균 보간법과, 본 논문에서 제안하는 격자 대표값 선정 알고리즘(Gridding Algorithms)의 결과를 비교하고, 최종적으로 얻어지는 해저 수치지형모델(DEM, Digital Elevation Model)과 후방산란 영상을 제시한다. 빠른 한지형잔디들이 지표면을 피복하도록 하고 여름의 고온기와 장마시기에는 뿌리전단력이 우수한 이러한 초종들로 지표면이 피복되도록 하는 것이 이상적이라 생각된다. 4. 혼파처리간의 토사유출량을 비교한 결과 토사 유출 억제효과는 한지형과 나지형잔디들의 혼합형(MixtureIII)과 자생처리구(MixtureV), Italian ryegrass와 자생식물의 혼합형(MixtureIV)등에서 비교적 낮은 수치를 토사유출량을 기록하였다. 이러한 결과는 자생식물들이 비록 초기생육속도는 외래도입초종에 떨어지지만 토사유출의 억제효과면에서는 이들 외래초종에 필적할 수 있음을 나타낸다고 할 수 있겠다.중량이 약 115kg/$m^2$정도로 나타났다.소 들(환경의 의미, 사람의 목적과 지식)보다 미학적 경험에 주는 영향이 큰 것으로 나타났으며, 모든 사람들에게 비슷한 미학적 경험을 발생시키는 것 이 밝혀졌다. 다시 말하면 모든 사람들은 그들의 문화적인 국적과 사회적 인 직업의 차이, 목적의 차이, 또한 환경의 의미의 차이에 상관없이 아름다 운 경관(High-beauty landscape)을 주거지나 나들이 장소로서 선호했으며, 아름답다고 평가했다. 반면에, 사람들이 갖고 있는 문화의 차이, 직업의 차 이, 목적의 차이, 그리고 환경의 의미의 차이에 따라 경관의 미학적 평가가 달라진 것으로 나타났다.corner$적 의도에 의한 경관구성의 일면을 확인할수 있지만 엄밀히 생각하여 보면 이러한 예의 경우도 최락의 총체적인 외형은 마찬가지로 $\ulcorner$순응$\lrcorner$의 범위를 벗어나지 않는다. 그렇기 때문에도 $\ulcorner$순응$\lrcorner$$\ulcorner$표현$\lrcorner$의 성격과 형태를 외형상으로 더욱이 공간상에서는 뚜렷하게 경계

  • PDF

Performance Characteristics of 3D GSO PET/CT Scanner (Philips GEMINI PET/DT) (3차원 GSO PET/CT 스캐너(Philips GEMINI PET/CT의 특성 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Byeong-Il;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.318-324
    • /
    • 2004
  • Purpose: Philips GEMINI is a newly introduced whole-body GSO PET/CT scanner. In this study, performance of the scanner including spatial resolution, sensitivity, scatter fraction, noise equivalent count ratio (NECR) was measured utilizing NEMA NU2-2001 standard protocol and compared with performance of LSO, BGO crystal scanner. Methods: GEMINI is composed of the Philips ALLEGRO PET and MX8000 D multi-slice CT scanners. The PET scanner has 28 detector segments which have an array of 29 by 22 GSO crystals ($4{\times}6{\times}20$ mm), covering axial FOV of 18 cm. PET data to measure spatial resolution, sensitivity, scatter fraction, and NECR were acquired in 3D mode according to the NEMA NU2 protocols (coincidence window: 8 ns, energy window: $409[\sim}664$ keV). For the measurement of spatial resolution, images were reconstructed with FBP using ramp filter and an iterative reconstruction algorithm, 3D RAMLA. Data for sensitivity measurement were acquired using NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves after we confirmed that dead time loss did not exceed 1%. To measure NECR and scatter fraction, 1110 MBq of F-18 solution was injected into a NEMA scatter phantom with a length of 70 cm and dynamic scan with 20-min frame duration was acquired for 7 half-lives. Oblique sinograms were collapsed into transaxial slices using single slice rebinning method, and true to background (scatter+random) ratio for each slice and frame was estimated. Scatter fraction was determined by averaging the true to background ratio of last 3 frames in which the dead time loss was below 1%. Results: Transverse and axial resolutions at 1cm radius were (1) 5.3 and 6.5 mm (FBP), (2) 5.1 and 5.9 mm (3D RAMLA). Transverse radial, transverse tangential, and axial resolution at 10 cm were (1) 5.7, 5.7, and 7.0 mm (FBP), (2) 5.4, 5.4, and 6.4 mm (3D RAMLA). Attenuation free values of sensitivity were 3,620 counts/sec/MBq at the center of transaxial FOV and 4,324 counts/sec/MBq at 10 cm offset from the center. Scatter fraction was 40.6%, and peak true count rate and NECR were 88.9 kcps @ 12.9 kBq/mL and 34.3 kcps @ 8.84 kBq/mL. These characteristics are better than that of ECAT EXACT PET scanner with BGO crystal. Conclusion: The results of this field test demonstrate high resolution, sensitivity and count rate performance of the 3D PET/CT scanner with GSO crystal. The data provided here will be useful for the comparative study with other 3D PET/CT scanners using BGO or LSO crystals.