• Title/Summary/Keyword: L-필터

Search Result 450, Processing Time 0.026 seconds

Detection of Abnormal Leakage and Its Location by Filtering of Sonic Signals at Petrochemical Plant (비정상 음향신호 필터링을 통한 플랜트 가스누출 위치 탐지기법)

  • Yoon, Young-Sam;Kim, Cheol
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.6
    • /
    • pp.655-662
    • /
    • 2012
  • Gas leakage in an oil refinery causes damage to the environment and unsafe conditions. Therefore, it is necessary to develop a technique that is able to detect the location of the leakage and to filter abnormal gas-leakage signals from normal background noise. In this study, the adaptation filter of the finite impulse response (FIR) least mean squares (LMS) algorithm and a cross-correlation function were used to develop a leakage-predicting program based on LABVIEW. Nitrogen gas at a high pressure of 120 kg/$cm^2$ and the assembled equipment were used to perform experiments in a reverberant chamber. Analysis of the data from the experiments performed with various hole sizes, pressures, distances, and frequencies indicated that the background noise occurred primarily at less than 1 kHz and that the leakage signal appeared in a high-frequency region of around 16 kHz. Measurement of the noise sources in an actual oil refinery revealed that the noise frequencies of pumps and compressors, which are two typical background noise sources in a petrochemical plant, were 2 kHz and 4.5 kHz, respectively. The fact that these two signals were separated clearly made it possible to distinguish leakage signals from background noises and, in addition, to detect the location of the leakage.

Development of Gait Analysis Algorithm for Hemiplegic Patients based on Accelerometry (가속도계를 이용한 편마비 환자의 보행 분석 알고리즘 개발)

  • 이재영;이경중;김영호;이성호;박시운
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.41 no.4
    • /
    • pp.55-62
    • /
    • 2004
  • In this paper, we have developed a portable acceleration measurement system to measure acceleration signals during walking and a gait analysis algorithm which can evaluate gait regularity and symmetry and estimate gait parameters automatically. Portable acceleration measurement system consists of a biaxial accelerometer, amplifiers, lowpass filter with cut-off frequency of 16Hz, one-chip microcontroller, EEPROM and RF(TX/RX) module. The algerian includes FFT analysis, filter processing and detection of main peaks. In order to develop the algorithm, eight hemiplegic patients for training set and the other eight hemiplegic patients for test set are participated in the experiment. Acceleration signals during 10m walking were measured at 60 samples/sec from a biaxial accelerometer mounted between L3 and L4 intervertebral area. The algorithm, detected foot contacts and classified right/left steps, and then calculated gait parameters based on these informations. Compared with video data and analysis by manual, algorithm showed good performance in detection of foot contacts and classification of right/left steps in test set perfectly. In the future, with improving the reliability and ability of the algerian so that calculate more gait Parameters accurately, this system and algerian could be used to evaluate improvement of walking ability in hemiplegic patients in clinical practice.

Complete genome sequence of Comamonas sp. NLF-7-7 isolated from biofilter of wastewater treatment plant (폐수처리장의 바이오 필터로부터 분리된 Comamonas sp. NLF-7-7 균주의 유전체 염기서열 해독)

  • Kim, Dong-Hyun;Han, Kook-Il;Kwon, Hae Jun;Kim, Mi Gyeong;Kim, Young Guk;Choi, Doo Ho;Lee, Keun Chul;Suh, Min Kuk;Kim, Han Sol;Lee, Jung-Sook;Kim, Jong-Guk
    • Korean Journal of Microbiology
    • /
    • v.55 no.3
    • /
    • pp.309-312
    • /
    • 2019
  • Comamonas sp. NLF-7-7 was isolated from biofilter of wastewater treatment plant. The whole-genome sequence of Comamonas sp. NLF-7-7 was analyzed using the PacBio RS II and Illumina HiSeqXten platform. The genome comprises a 3,333,437 bp chromosome with a G + C content of 68.04%, 3,197 total genes, 9 rRNA genes, and 49 tRNA genes. This genome contained pollutants degradation and floc forming genes such as sulfur oxidization pathway (SoxY, SoxZ, SoxA, and SoxB) and floc forming pathway (EpsG, EpsE, EpsF, EpsG, EpsL, and glycosyltransferase), respectively. The Comamonas sp. NLF-7-7 can be used to the purification of wastewater.

Impact of face masks on spectral and cepstral measures of speech: A case study of two Korean voice actors (한국어 스펙트럼과 캡스트럼 측정시 안면마스크의 영향: 남녀 성우 2인 사례 연구)

  • Wonyoung Yang;Miji Kwon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.4
    • /
    • pp.422-435
    • /
    • 2024
  • This study intended to verify the effects of face masks on the Korean language in terms of acoustic, aerodynamic, and formant parameters. We chose all types of face masks available in Korea based on filter performance and folding type. Two professional voice actors (a male and a female) with more than 20 years of experience who are native Koreans and speak standard Korean participated in this study as speakers of voice data. Face masks attenuated the high-frequency range, resulting in decreased Vowel Space Area (VSA) and Vowel Articulation Index (VAI)scores and an increased Low-to-High spectral ratio (L/H ratio) in all voice samples. This can result in lower speech intelligibility. However, the degree of increment and decrement was based on the voice characteristics. For female speakers, the Speech Level (SL) and Cepstral Peak Prominence (CPP) increased with increasing face mask thickness. In this study, the presence or filter performance of a face mask was found to affect speech acoustic parameters according to the speech characteristics. Face masks provoked vocal effort when the vocal intensity was not sufficiently strong, or the environment had less reverberance. Further research needs to be conducted on the vocal efforts induced by face masks to overcome acoustic modifications when wearing masks.

STUDY OF THE EVOLUTION OF SL-9 IMPACT SITES ON JUPITER WITH THE KYUNGHEE UNIVERSITY 30 INCH TELESCOPE (경희대학교 망원경을 이용한 SL-9의 목성 충돌 후 충돌 흔적 진화 관측 연구)

  • Son, D. H.;Song, Y. M.;Lee, S. G.;Jin, H.;Kim, K.-S.;Kim, S. J.
    • Journal of Astronomy and Space Sciences
    • /
    • v.12 no.2
    • /
    • pp.204-215
    • /
    • 1995
  • We observed SL-9 impact sites on Jupiter with a CCD and a R filter on the KyungHee University 30-inch telescope between July 17 and September 3, 1994. We identified impact sites of A, C, E, G, H, K, L, Q1, W and G-group, We calculated the moving velocity relative to System II and rotation period of the G, L sites to be from -8.0 to 8.8m/s, and $9^h55^m39.4^s\pm34^s$, respectively. The diameters of G and L sites in our first observation were $1.95\times10^4km,\;and\;2.20\times10^4km$, respectively. In particular, we investigated the evolution of the impact sites by calculating the diffusing rates of the impact clouds.

  • PDF

A Comparative Study of Production of [68Ga]PSMA-11 with or without Cassette Type Modules (비 카세트 방식과 카세트 방식을 이용한 [68Ga]PSMA-11의 자동 합성 방법 비교)

  • Hyun-Sik, Park;Byeong-Min, Jo;Hyun-Ho, An;Hong-Jin, Lee;Jin-Hyeong, Lee;Gyeong-Jae, Lee;Byung-Chul, Lee;Won-Woo, Lee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.2
    • /
    • pp.15-19
    • /
    • 2022
  • Purpose [68Ga]PSMA-11 is needed the high reproducibility, excellent radiochemical yield and purity. In term of radiation safety, the radiation exposure of operator for its production also should be considered. In this work, we performed a comparative study for the fully automated synthesis of [68Ga]PSMA-11 between non-cassette type and cassette type. Materials and Methods Two different type of modules (TRACERlab FX N pro for non-cassette type and BIKBox for cassette type) were used for the automated production of [68Ga]PSMA-11. According to the previously identified elution profile, Only 2.5 ml with high radioactivity was used for the reaction. After adjusting the pH of the reaction solution with HEPES buffer solution, the precursor was added and reacted with at 95 ℃ for 15 minutes. The reaction mixture was separated and purified using a C18 light cartridge. The product was eluted with 50% EtOH/saline solution and diluted with saline. It was completed by sterilizing filter. In the non-cassette type, the aforementioned process must be prepared directly. However, in the cassette method, synthesis was possible simply by installing a kit that was already completed. Results Both total [68Ga]PSMA-11 production time were 25±3(non-cassette type) and 23±3 minutes(cassette type). The radiochemical yield of the non-cassette type(65.5±5.7%) was higher than that of the cassette type(61.6±4.8%) after sterilization filter. The non-cassette type took about 120 minutes of preparation time before synthesis due to washing of synthesizer and reagent preparation. However, since the cassette type does not require washing and reagent preparation, it took about 20 minutes to prepare before synthesis. Both type of synthesizer had a radiochemical high purity(>99%). Conclusion The non-cassette type production of [68Ga]PSMA-11 showed higher radiochemical yield and lower cost than the cassette type. However, The cassette type has an advantage in terms of preparation time, convenience, and equipment maintenance.

Auto-compatibility Analysis for Ka-band payload of COMS

  • Park, Jae-Woo;Lee, Seong-Pal;Baek, Myung-Jin
    • Journal of Satellite, Information and Communications
    • /
    • v.2 no.2
    • /
    • pp.41-47
    • /
    • 2007
  • The first geostationary satellite made by Korea, COMS, has the three different payload ; Meteorological sensor, Oceanographic sensor and Ka-band communication payload. There are Meteorological & Ocean Data Communication Subsystem(MODCS) and Telemetry, Command and Ranging Subsystem(TC&R) as other RF radiation sources. MODCS transmits and receives Meteo and Ocean measurement data from/to earth using L-band and TC&R using S-band. The Ka-band communication payload will provide high-speed multimedia services and communication services for natural disaster such as prediction, prevention, and recovery services in the government communications network.Ka-band beacon is for the earth antenna pointing and the experiment of rain fading. This paper gives the analysis results about the mutual radiation effect on Ka-band communication payload, Ka-band beacon, MODCS and TC&R. Up/Down link power and coupling factor including the geometrical position and distance of antenna, filter rejection and degradation factor due to the different polarization are considered. The results show MODCS and TC&R are compatible for Ka-band communication payload and Ka-band beacon does not interfere with MODCS and TC&R normal operation.

  • PDF

Determination of methamphetamine, 4-hydroxymethamphetamine, amphetamine and 4-hydroxyamphetamine in urine using dilute-and-shoot liquid chromatography-tandem mass spectrometry (시료 희석 주입 LC-MS/MS를 이용한 소변 중 메스암페타민, 4-하이드록시메스암페타민, 암페타민 및 4-하이드록시암페타민 동시 분석)

  • Heo, Bo-Reum;Kwon, NamHee;Kim, Jin Young
    • Analytical Science and Technology
    • /
    • v.31 no.4
    • /
    • pp.161-170
    • /
    • 2018
  • The epidemic of disorders associated with synthetic stimulants, such as methamphetamine (MA) and amphetamine (AP), is a health, social, legal, and financial problem. Owing to the high potential of their abuse and addiction, reliable analytical methods are required to detect and identify MA, AP, and their metabolites in biological samples. Thus, a dilute-and-shoot liquid chromatography-tandem mass spectrophotometry (LC-MS/MS) was developed for simultaneous determination of MA, 4-hydroxymethamphetamine (4HMA), AP, and 4-hydroxyamphetamine (4HA) in urine. Urine sample ($100{\mu}L$) was mixed with $50{\mu}L$ of mobile phase consisting of 0.4 % formic acid and methanol and $50{\mu}L$ of working internal-standard solution. Aliquots of $8{\mu}L$ diluted urine was injected into the LC-MS/MS system. For all analytes, chromatographic separation was performed using a C18 reversed-phase column with gradient elution and a total run time of 5 min. The identification and quantification were performed by multiple reaction monitoring (MRM). Linear least-squares regression was conducted to generate a calibration curve, with $1/x^2$ as the weighting factor. The linear ranges were 2.0-200, 1.0-800, and 10-2500 ng/mL for 4HA and 4HMA, AP, and MA, respectively. The inter- and intraday precisions were within 6.6 %, whereas the inter- and intraday accuracies ranged from -14.9 to 11.3 %. The low limits of quantification were 2.0 ng/mL (4HA and 4HMA), 1.0 ng/mL (AP), and 10 ng/mL (MA). The proposed method exhibited satisfactory selectivity, dilution integrity, matrix effect, and stability, which are required for validation. Moreover, the purification efficiency of high-speed centrifugation was clearly higher than 6-15 % for QC samples (n=5), which was higher than that of the membrane-filtration method. The applicability of the proposed method was tested by forensic analysis of urine samples from drug abusers.

Design and Implementation of a Wearable $SpO_2$ Module based WSN (무선센서네트워크 기반의 손목 착용형 $SpO_2$ 모듈 설계 및 구현)

  • Jung, Sang-Joong;Seo, Yong-Su;Chung, Wan-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.495-498
    • /
    • 2008
  • This paper describes design of a real-time, wearable reflectance pulse oximetry which is based Wireless Sensor Network. For the purpose of continuously monitoring vital signs of a human, wearable reflectance pulse oximetry is built into a wrist type that can be obtained $SpO_2$ value of patient unobtrusively. This designed $SpO_2$ module is based on a low-power 8 bit ATmega128L microcontroller operating in 3V. Low power operating $SpO_2$ module was integrated to wireless sensor node for user's health monitoring. This paper is focused on the successful integration of all these components into wearable reflectance pulse oximetry and evaluates its ability to measure patient' $SpO_2$ value. Information from this sensor was wirelessly transmitted to a base-station for storage and display purposes.

  • PDF

Experimental Study on the Effect of Flame Surface Area Fluctuation on the Heat Release Fluctuation in a Premixed Bunsen Flame (예혼합 분젠 화염에서의 화염 표면적 변동이 열발생 변동에 미치는 영향에 관한 실험적 연구)

  • Park, Jang-Hee;Lee, Dae-Keun;Shin, Hyun-Dong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.2
    • /
    • pp.197-202
    • /
    • 2010
  • A combustion chamber with a branch tube was built to investigate the characteristics of a spontaneous oscillating laminar premixed Bunsen flame. The flame behavior was observed, and the relation between the flame surface area and heat release rate was inspected. The equivalence ratio and mean velocity were fixed at 1.1 and 1.75 m/s, respectively. The amplitude of the pressure fluctuation in the combustion chamber was changed and the flame behavior was affected when the length ratio between the branch tube and combustion chamber (L:R) was varied. The $OH^*$, $CH^*$, and flame chemiluminescence had similar behavior qualitatively. There was linearity between the flame surface area and heat release rate.