• Title/Summary/Keyword: L-필터

Search Result 449, Processing Time 0.026 seconds

Evaluation of the Stability of Oxidation-Reduced Potential (ORP) Using the Filter of the Alkaline Water (알칼리 환원수 필터의 산화환원전위 안정화 평가)

  • Nam, Sangyep;Kwon, Yunjung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.8
    • /
    • pp.129-135
    • /
    • 2016
  • This study is about ionic water generator filter Recently, a lot of people feel deep interest in health and drinking water. Evaluation of the stability of oxidation-reduced potential (ORP) using the filter of the alkaline water. This study utilizes the three filter of activated carbon, UF, carbon block in alkaline reduced water equipment. Passing the water to the filter is evaluated that the OPR values are stability in accordance with the change of the volume in the bucket. Alkaline reduced water equipment is a system that has the function of making the water reduction. This system is the values of the human body beneficial minerals and ORP are made in the functional water has a very low value than general water. Which has passed through the filter the water in the water negative ions and positive ions through the electrolytic. After electrolysis, the cathode side by water, including $Ca^+$, $K^+$, $Mg^+$, $Na^+$ water gets Alkaline Reduced Water containing the minerals beneficial to the human body. A positive electrode side is made of the organic materials that have an anion such as chlorine (Cl), phosphorus (P), sulfur(S). This experiment uses the Alkaline Reduced Water to adjust the magnitude of the voltage of the electrolysis in the Alkaline Reduced Water. That is 1st step(pH8) 2nd step (pH8.5) 3th step (pH9), 4th step (pH9.5) in the Alkaline Reduced Water and -1st step (pH6.0), -2nd step (pH5.0) used as the acidic oxidation water. When the water passes through the three filter in this system was evaluated whether the ORP values are changed and stabilized. When about 100 liters of water passing through the filter was confirmed that the ORP values are stability and evaluation.

Impedance-matching Method Improving the Performance of the SAW Filter (탄성표면파 필터의 성능 개선을 위한 임피던스 정합의 해석적 방법)

  • 이영진;이승희;노용래
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.5
    • /
    • pp.69-75
    • /
    • 2001
  • In this paper, a fast and easy impedance matching method, which could give the impedance matching component for the general 1 or 2-port network was introduced. First, the entire network structure was defined which consists of the network part to be matched and the impedance matching part composed of inductors and capacitors. Next, the transmission matrix and input and output impedances of the entire network from the terminal impedance conditions were calculated, then the exact solutions for the matching components were obtained. To verify the efficiency of this method, this method was applied to the CDMA If band withdrawal weighted SAW transversal filter, and investigated the effects of the impedance matching before and after, through the simulation and experiment. As the result, the performance of a fractional bandwidth of 1.2%, insertion loss of 29 dB, and VSWR of 80 have improved to a factional bandwidth of 1.8%, insertion loss of 9 dB, VSWR of 3 at 85.38 MHz center frequency. The result shows that this impedance matching method could be used in the SAW devices and other types of 1 or 2-port network.

  • PDF

The study of Rolled Steel Process Wastewater by Superconducting High Gradient Magnetic Separation (초전도 마그네트를 이용한 고구배 자기분리 열연강판 폐수처리에 관한 연구)

  • Kim, Tea-Hyung;Ha, Dong-Woo;Oh, Sang-Soo;Kim, Ho-Sup;Ko, Rock-Kil;Kwon, Jun-Mo;Lee, Nam-Jin;Kim, Young-Hun;Kang, Chae-Hun;Ha, Tae-Wook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.11-11
    • /
    • 2009
  • 종래의 산업폐수 처리기술로는 중금속 함유 폐수에 수용성의 금속염을 첨가하여 가성소다 혹은 소석회를 이용하여 pH를 조정하고 고분자 응집제를 첨가하여 금속의 수산화물을 생성시켜 이를 부상 혹은 침전시켜 Sludge화하여 제거하는 방법이 주로 사용되고 있다. 그 외 질소, 인, 유기물이 함유된 폐수의 경우에는 Biological Oxidation Techniques, 활성탄 흡착방식이 주로 채택되고 있다.[1-3] 이러한 폐수처리기술은 화학약품 사용량이 과다하고 이는 Sludge 생성량을 증대하고 2차 폐수처리가 필요로 하는 경우가 많고, 처리장이 면적이 넓어야 하고 대용량의 Sludge 제거창치가 필요하여 고비용의 처리공정으로 문제점을 가지고 있다.[2-3] 이에 본 연구에서는 이러한 기존 기술의 문제점을 보완할 수 있고 기존 기술로는 완벽하게 처리하기 곤란한 악성 폐수들에 대한 새로운 고도처리기술로 초전도 마그네트를 이용한 고구배 자기분리기술에 대한 기초연구를 하였다. 본 연구에서 사용한 고구배 자기분리 시스템은 무헬륨 전도냉각방식으로 자기분리를 위해 사용한 필터는 SUS 430 재질의 메쉬 형태로 제작하여 실험하였다. 또한, 자기분리 처리를 위한 전처리 공정으로는 응집제를 첨가하여 자기분리 효율을 높이고자 하였다. 자기분리 처리대상수로는 포항제철에 압연 강판에 사용되는 냉각수를 대상으로 자기분리 처리에 대한 효과를 실험하였다. 또한, 자기분리에 대한 특성을 평가하기 위해 강자성의 $Fe_3O_4$ 미세자성분말을 첨가하여 처리수내의 들어있는 유기물질에 대해 자기분리 자장 및 유속에 대한 처리효율을 미치는 영향을 조사하였다. 자기분리 처리는 1~6 Tesla에서 자기필터는 디스크 형태로 다층으로 연속적으로 적층하였으며, 처리유속은 1~4 l/min으로 하였다. 고농도인 처리폐수를 자가분리 인가 자장에 따라 처리하여 고농도에서는 70%, 저농도에서는 98 %까지 처리되었다. 또한, 자기분리용 필터는 SUS 430 재질의 mesh 망을 사용하였으며 인가자장 및 유속변화에 대한 실험 결과 탁도 및 농도는 필터 크기의 영향은 거의 차이가 없었으며 단지 인가자장 및 유속에 따라서 지수적으로 감소하였다. 자기분리된 용액 내 $Fe_3O_4$ 입도 분석 결과 자기분리 이전에 분포하던 $10\sim20\;{\mu}m$의 입자는 거의 제거되었으며 2 ${\mu}m$ 이하의 입자들은 실험 횟수에 따라 점점 직경이 작은 쪽으로 분포가 좁아졌으며, 마그네타이트의 자화율을 분석한 결과 약 0.8 Tesla에서 포화 되었으며 처리수의 탁도 및 농도가 자장에 따라 감소하는 것으 알 수 있었다.

  • PDF

A Study on the Variation of Transmission Factors, Output Factors and Percent Depth Doses by Wedge Filters for 4~10 MV X-Ray Beams (4~10 MV X-선의 쐐기 (wedge) 필터의 투과율과 출력계수, 선축상 선량분포의 변화에 관한 연구)

  • 강위생
    • Progress in Medical Physics
    • /
    • v.8 no.2
    • /
    • pp.3-17
    • /
    • 1997
  • Because a wedged beam consists of attenuated primary photons and scattered radiations from wedge, the spectrum of the wedged beam does not coincide with that of an open beam with same geometry. The aims of current report are to get exact information about whether effects of 15-60$^{\circ}$ wedge for 4 -10 MV photon beams should be considered for dose calculation or not, and to suggest a reference condition for measurement of wedge transmission factor. Percent depth dose of both open and wedged fields with angles of 15, 30, 45, 60$^{\circ}$ for beams of 4 MV(Clinac 4/100, Varian), two 6 MV(Clinac 6/100 and Clinac 2100C, Varian), 10 MV(Clinac 2100C, Varian) X-rays were measured to 30cm deep in water using ionization chambers. Hardening factors of photon beams were calculated with measured PDDs. Both field size factors and transmission factors of wedge filters were measured at d$_{max}$ in water. Beam hardening factors of wedged fields of 4 and 6 MV X-ray were larger than 1 for all wedge angles, field sizes and depths deeper than d$_{max}$ Beam hardening factors for wedge angles 15, 30, 45, 60$^{\circ}$ for 10$\times$10cm were respectively 1.010, 1.014, 1.023 and 1.034 for 4MV X-ray, 1.005, 1.008, 1.019, and 1.024 for 6MV X-ray of Clinac 6/100, 1.011, 1.021, 1.032, 1.036 for 6MV X-ray of Clinac 2100C, and 1.008, 1.012, 1.012 and 1.012 for 10MV X-ray. Beam hardening factors of 10MV X-ray were 1 within 1.2% difference for all wedge angles, depths and field sizes. It was made clear that for 6MV X-rays, the beam hardening factor depends on treatment machine. The relationship of the factor and depth was linear. Field size factor at d$_{max}$ was independent of wedge angle except for the field of 15$\times$15cm. and maximum difference of the field size factors for the field size was 1.4% for 4MV X-ray. When the wedge factor is determined, dependence of the factor on field size is negligible at d$_{max}$ but should be considered at deeper depth. Calculating dose distribution or MU, the beam hardening factor should be applied for 4~6MV X-ray beams, but might not be considered for 10MV beam. When wedge transmission factor was determined at d$_{max}$ or in air, field size factors for open field are also applicable to wedged fields, but otherwise, field size factor for each wedge or wedge factor depending on field size should be applied.

  • PDF

A Vibration-based Fault Diagnostics Technique for the Planetary Gearbox of Wind Turbines Considering Characteristics of Vibration Modulation (풍력발전기 유성기어박스의 진동 변조 특성을 고려한 진동기반 고장 진단 기법 고찰)

  • Ha, Jong M.;Park, Jungho;Oh, Hyunsoek;Youn, Byeng D.
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.7
    • /
    • pp.665-671
    • /
    • 2015
  • The performance of fault diagnostics for a planetary gearbox depends on vibration modulation characteristics, which can vary with manufacturing & assembly tolerance, and load condition. In this paper, a fault diagnostics technique that considers vibration modulation characteristics is proposed for the effective fault detection of planetary gearboxes in wind turbines. For identifying the vibration modulation characteristics in practice, re-sampled vibration signals are processed with narrow band-pass filters. Thereafter, the optimal position of the vibration extraction window is identified for effective detection of faulty signals under the varying vibration modulation characteristics. The proposed diagnostics technique makes it possible to perform robust diagnostics of the planetary gearbox with regard to the changeable vibration modulation effect. For demonstrating the proposed fault diagnostics technique, a 2-kW WT testbed is designed with two DC motors and gearboxes. A faulty gear with partial tooth breakage is machined and assembled into the gearbox.

A Study of High Temperature Filtration Performance Test on Low Density Cylindrical Ceramic Filters (저밀도 원통형 세라믹 필터의 고온 여과 성능시험 연구)

  • 이동섭;홍민선;최종인
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.2
    • /
    • pp.213-222
    • /
    • 2001
  • Cylindrical type ceramic filers, that is 60 O.D$\times$10t$\times$600L and 60 O.D$\times$10t$\times$1,000L were manufactured by vacuum forming processes using ceramic ray materials. For cylindrical type ceramic filters, porosity and bulk density were measured for, 80 to 90% and 0.3 to 0.4 g/㎤, respectively at uniform pore size of 41 to 45${\mu}{\textrm}{m}$. Bench scale candle filters (60$\psi$ $\times$10t$\times$600L) were tested using different dusts collected from many industries including chemical processing, glass processing and metal manufacturing pants. Collection efficiencies found out to range from 99.87% to 99.90%, while resistance coefficients from 1.1$\times$10(sup)11/$m^2$ to 1.7$\times$10(sup)11/$m^2$ . Full scale low density ceramic filters (60$\psi$ $\times$10t$\times$1,000L) were also tested at 1 atm, $600^{\circ}C$ to reveal the filtration efficiency, conditioning, and resistance coefficients using two different types of dust as chemical processing and metal refined processing. Darcys law resistance coefficients were measured to range 1.44$\times$10(sup)11/$m^2$ to 2.74$\times$10(sup)11/$m^2$, and collection efficiencies on the range 99.84 to 99.96%, Finally, results of long term performance test showed that filters were conditioned after 170hrs. Experimental conditions for effective filtration were examined under the condition 10 cm/sec face velocity, 3kg/$\textrm{cm}^2$ pulsing pressure, 5 min filtration cycle, and 300msec pulse opening time.

  • PDF

An Enhanced Affine Projection Sign Algorithm in Impulsive Noise Environment (충격성 잡음 환경에서 개선된 인접 투사 부호 알고리즘)

  • Lee, Eun Jong;Chung, Ik Joo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.33 no.6
    • /
    • pp.420-426
    • /
    • 2014
  • In this paper, we propose a new affine projection sign algorithm (APSA) to improve the convergence speed of the conventional APSA which has been proposed to enable the affine projection algorithm (APA) to operate robustly in impulsive noise environment. The conventional APSA has two advantages; it operates robustly against impulsive noise and does not need calculation for the inverse matrix. The proposed algorithm also has the conventional algorithm's advantages and furthermore, better convergence speed than the conventional algorithm. In the conventional algorithm, each input signal is normalized by $l_2$-norm of all input signals, but the proposed algorithm uses input signals normalized by their corresponding $l_2$-norm. We carried out a performance comparison of the proposed algorithm with the conventional algorithm using a system identification model. It is shown that the proposed algorithm has the faster convergence speed than the conventional algorithm.

Continuous Coprecipitantion Preconcentration-Hydride Generation for Arsenic in Inductively Coupled Plasma-Atomic Emission Spectrometry (연속적 공침 선농축-수소화물 발생법을 이용한 ICP-AES에서의 비소의 감도 개선)

  • Kim, Chang-Gyu;Pak, Yong-Nam
    • Journal of the Korean Chemical Society
    • /
    • v.48 no.6
    • /
    • pp.583-589
    • /
    • 2004
  • In a stream of aqueous sample, trace arsenic ions were quantitatively coprecipitated and detected in ICP-AES through hydride generation. In was used as a coprecipitating reagent. The precipitate was collected on a filter and dissolved by HCl. The eluted As was sent into the reaction coil to generate hydrides and analyzed by ICP. With optimal conditions, and with a sample of 0.3 mL, an enrichment of 70 was obtained with the sampling speed of 10/hr. When compared with coprecipitation and hydride generation technique, the sensitivity was increased by 7 and 10 times, respectively. The limit of detection limit$(3{\sigma})$ was 0.020 ${\mu}g\;L^{-1}$ and the precision was 7-10%. Separation of $As^{3+}\;and\;As^{5+}$ were possible using citric acid in hydride generation.

Study on simultaneous determination of aromatic material causing allergic in children's products by GC-MSD (GC-MSD를 이용한 어린이 제품 중 알러지 유발 방향성 물질의 동시분석법 연구)

  • Ko, Kyeong Mok;Rhu, Chan Joo;Ko, Byeong Rae;Lee, Seok Ki
    • Analytical Science and Technology
    • /
    • v.33 no.3
    • /
    • pp.134-142
    • /
    • 2020
  • Twenty-one allergy-induced aromatic material in children's products were analyzed using gas chromatography mass spectrometer(GC-MSD). The analytes were extracted using an automatic Soxhlet extractor, centrifuged for 10 minutes in a fast freezing centrifuge, and the supernatant was filtered with a syringe filter and then transferred into a 2 mL vial and injected in a split mode. In the established condition, the calibration curve showed linearity with a determination coefficient of 0.9981 or more. Sensitivity was 0.3145 ~ 1.6757, which showed a fairly wide range of sensitivity for each substance. The detection limit of the device was 0.0016 ~ 0.0423 ㎍/mL and the maximum detection limit was less than 0.05 ㎍/mL. The method detection limit ranged from 0.0030 ~ 0.0589 ㎍/mL. In addition, the limit of quantification ranged from 0.0096 to 0.1876 ㎍/mL, with precision ranging from 0.41 to 10.49 % and accuracy ranging from 83 to 116 %. The analytical method developed in this study was applied to commercial products.

Determination of bromate in bottled mineral water in Korea (먹는 샘물 중 bromate 분석 및 분포 특성)

  • Ahn, Hye-Sil;Kim, Hyun-Koo;Park, Ju-Hyun;Jung, Dong-Il;Kim, Tae-Seung
    • Analytical Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.155-160
    • /
    • 2010
  • This study was performed to compare international analytical methods of bromate and applied to determine bromate in bottled mineral water in Korea. Bromate in bottled mineral water was eluted by 10~50 mM potassium hydroxide (KOH) and determined by ion chromatograph-suppressed conductivity detector (ICCD). Sample was purified with on guard Ba-, Ag- and H-cartridges and $0.2\;{\mu}m$ membrane filter. The method detection limit (MDL) and the limit of quantitation (LOQ) of bromate were 0.1 and $0.5\;{\mu}g/L$, respectively. The calibration curve showed good lineality above 0.9998 in the ranges of the $0.5\sim40\;{\mu}g/L$. Bromate from 33 samples among total 157 bottled mineral water samples was detected in the concentration range of $0.5\sim6.5\;{\mu}g/L$. The detected concentrations were within bottled mineral water quality criteria ($10\;{\mu}g/L$) in Korea.