• Title/Summary/Keyword: KoreanWave

Search Result 15,234, Processing Time 0.051 seconds

Clinical Features of Isolated Noncompaction of the Ventricular Myocardium (심근의 단독 비경화증(Isolated Noncompaction of Ventricular Myocardium)의 임상 양상)

  • Moon, Eun-Kyoung;Lee, Hoon-Young;Chang, Mea-Young;Kil, Hong-Ryang;Chung, Yong-Hun
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.12
    • /
    • pp.1528-1533
    • /
    • 2002
  • Purpose : Isolated noncompaction of the ventricular myocardium(INVM) is one of the unclassified cardiomyopathies that is characterized by numerous, excessively prominent trabeculations, and deep intertrabecular recesses. We performed this study to evaluate the clinical features of INVM in children. Methods : The medical records of 10 patients with INVM were reviewed. We analyzed the clinical manifestations, hemodynamics, pattern of inheritance, and long-term prognosis of INVM in children. Results : Age at diagnosis was $45{\pm}53months$(1 day-14 years) with follow-up lasting as long as 78 months. Most INVM was asymptomatic on diagnosis. Associated cardiac anomalies were noted in six patients(ventricualr or atrial septal defect, patent ductus arteriosus with mitral valve prolapse, or mitral valve cleft). Depressed or flat changes of T wave in lead II, III and aVF were observed on electrocardiography. Various arrhythmia including WPW syndrome with paroxysmal supraventricular tachycardia, third-degree atrioventricular block, and familial sick sinus node dysfuction were observed. The degree of trabeculation in INVM was significantly prominent from level of mitral valve to apex compared to age-matched control. Familial recurrences were noted in two patients. The systolic function of the left ventricle was decreased in 20% of patients during the follow-up period, but systemic embolism or ventricular tachycardia was not observed. Conclusion : INVM is not a rare disorder. The cardiac function may be deteriorated in children as well as adults during long-term follow up. Thus early diagnosis and long-term follow-up must be done. So, the nation-wide multicenter clinical study would be mandatory to evaluate the incidence, long-term prognosis, and establishment of objective diagnostic criteria of INVM.

A Clinical Study of Hypertrophic Pyloric Stenosis (비후성 유문 협착증의 임상적 고찰)

  • Kim, Yoon Hee;Jung, Myung Sup;Byun, Soon Ok
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.11
    • /
    • pp.1389-1396
    • /
    • 2002
  • Purpose : This study was done to analyze the changes in the clinical conditions and the diagnosis of hypertrophic pyloric stenosis. Methods : We report a retrospective clinical analysis of 39 patients with hypertrophic pyloric stenosis from Jan. 1992 to Aug. 2001. The age and sex distribution, family and birth history, clinical symptoms, the ultrasonographic and the operative sizes of pyloric canals were compared. Results : The body weight was below the 3 percentile at admission in eight cases(20.5%). "Olive like mass" in right upper quadrant was palpated during physical examination in 23 cases(59%) and gastric peristaltic wave observed in six cases(15%). The ultrasonographic measurements showed that the pyloric muscle thickness to be $4.95{\pm}0.99mm$($mean{\pm}SD$), pyloric diameter $14.42{\pm}2.64mm$, and pyloric length $20.17{\pm}3.92mm$. Fredet-Ramstedt pyloromyotomy was employed in all cases. The operative measurements of the pyloric muscle thickness was $5.11{\pm}1.01mm$, pyloric diameter $15.01{\pm}2.47mm$, and pyloric length $22.32{\pm}3.43mm$. Conclusion : There was no significant difference between the ultrasonographic and operative measurements. Currently, the hypertrophic pyloric stenosis patients showed lesser clinical hallmarks of the disease. The earlier diagnosis using imaging studies before development of significant metabolic abnormalities is becoming an important factor that change the future outcomes of hypertrophic pyloric stenosis.

Estimation of Groundwater Table using Ground Penetration Radar (GPR) in a Sand Tank Model and at an Alluvial Field Site (실내 모형과 현장 충적층에서 지하투과레이더를 이용한 지하수면 추정)

  • Kim, Byung-Woo;Kim, Hyoung-Soo;Choi, Doo-Houng;Koh, Yong-Kwon
    • The Journal of Engineering Geology
    • /
    • v.23 no.3
    • /
    • pp.201-216
    • /
    • 2013
  • Ground penetrating radar (GPR) surveys were conducted in a sand tank model in a laboratory and at an alluvial field site to detect the groundwater table and to investigate the influence of saturation on GPR response in the unsaturated zone. In the sand tank model, the groundwater table and saturation in the sand layer were altered by injecting water, which was then drained by a valve inserted into the bottom of the tank. GPR vertical reflection profile (VRP) data were obtained in the sand tank model for rising and lowering of the groundwater table to estimate the groundwater table and saturation. Results of the lab-scale model provide information on the sensitivity of GPR signals to changes in the water content and in the groundwater table. GPR wave velocities in the vadose zone are controlled mainly by variations in water content (increased travel time is interpreted as an increase in saturation). At the field site, VRP data were collected to a depth of 220 m to estimate the groundwater table at an alluvial site near the Nakdong river at Iryong-ri, Haman-gun, South Korea. Results of the field survey indicate that under saturated conditions, the first reflector of the GPR is indicative of the capillary fringe and not the actual groundwater table. To measure the groundwater table more accurately, we performed a GPR survey using the common mid-point (CMP) method in the vicinity of well-3, and sunk a well to check the groundwater table. The resultant CMP data revealed reflective events from the capillary fringe and groundwater table showing hyperbolic patterns. The normal moveout correction was applied to evaluate the velocity of the GPR, which improved the accuracy of saturation and groundwater table information at depth. The GPR results show that the saturation information, including the groundwater table, is useful in assessing the hydrogeologic properties of the vadose zone in the field.

Availability of Cardiac Troponin T as a Marker for Detecting Perioperative Myocardial Damage in Patients with Open Heart Surgery (개심술후 발생한 심근손상에서 진단 표지자로서의 Troponin T의 임상적 유용성)

  • 김태이;정태은;이동협;이정철;한승세
    • Journal of Chest Surgery
    • /
    • v.31 no.1
    • /
    • pp.20-27
    • /
    • 1998
  • It is well known that troponin T(below TnT) is present in the myocardial cells and released during myocardial damage, so it`s very specific enzyme to myocardium. Availability of cardiac specific TnT in assessing perioperatively myocardial damage was evaluated from 34 open heart surgery patients. They consisted of 11 ischemic heart, 13 acquired valvular heart and 10 congenital heart cases. Patients were divided into two groups, group A(patients with myocardial damage) and group B(patients without myocardial damage), according to the symptom of chest pain suspecting angina and the ECG findings of ST segment and T wave changes which show myocardial ischemia and injury. Serum TnT levels were measured by enzyme immunoassay method preoperatively, immediately postoperatively, postoperative day 1, day 2, day 3, and day 7. We observed and analyzed the changes of serum TnT levels in two groups and compared the serum TnT levels with CK-MB levels measured at the same time. In group A, serum TnT levels showed 1.37$\pm$0.26$\mu$g/L, 3.16$\pm$0.66$\mu$g/L, 2.39$\pm$0.74$\mu$g/L, 2.49$\pm$0.76$\mu$g/L, and 1.23$\pm$0.60$\mu$g/L, immediate postoperatively, postoperatively day1, day2, day3, and day7, respectively. It was observed there were significant differences compared with those of group B(0.38$\pm$0.04$\mu$g/L, 0.34$\pm$0.05$\mu$g/L, 0.25$\pm$0.03$\mu$g/L, 0.24$\pm$0.04$\mu$g/L, and 0.11$\pm$0.03$\mu$g/L) during identical periods(P<0.01). Serum CK-MB level in group A significantly elevated to 145.04$\pm$35.08 IU/L on the postoperative day 1 compared to group B(31.28$\pm$5.87 IU/L, P<0.05), However, it stiffly decreased from day 2 and returned to preoperative level at day 3. When serum TnT level more than 1.0$\mu$g/L is thought to reflect myocardial damage, serum TnT had 100% of sensitivity and 87% of specificity in diagnosing the postoperative myocardial damage(p<0.01). I conclusion, serum TnT levels increased significantly at very early stage of myocardial damage and persisted much longer period than CK-MB. This suggests that serum TnT has more advantage and availability in assessing the perioperatively myocardial damage than any other tests.

  • PDF

Mineralogical Studies of the Tourmaline for Medicinal Applications by Production Localities (본초 광물로서의 활용을 위한 산지별 전기석의 광물학적 연구)

  • Jie, Yan;Kim, Seon-ok;Park, Hee Yul;Park, Maeng-Eon
    • Economic and Environmental Geology
    • /
    • v.51 no.4
    • /
    • pp.345-358
    • /
    • 2018
  • In this study, we have performed electron probe micro analyzer (EPMA), X-ray differaction (XRD), inductively coupled plasma spectroscopy (ICP), Fourier transform Raman spectroscopy (FT-Raman), far-infrared (FIR), nuclear magnetic resonance (NMR), and pH-DO Analyses for characterizing medicinal mineralogy aspect of the black tourmaline (Shantung, china), black and pink tourmaline (Minas Geraris, Brazil), black touemaline (Daeyu mine, Korea). In addition, heating effects of the tourmaline sauna as well as the effects of tourmaline powder-added soap on skin troubles have been investigated. It has been revealed that chemical composition of the tourmaline is either high in Fe-, Al-, B-rich types. Ratio of the K-Ca, Na-K, and Fe-B reflects the component change property of solid solution. $CaO/CaO+Na_2O$ and MgO/FeO+MgO ratio show high positive correlation. When tourmaline reacts with distilled water, extended reaction time DO values approximately decrease and it stabilizes at DO = 10. Otherwise, pH values increase until 6 hours and it stabilizes at pH = 8 after 24 hours. Distilled water changes to alkaline when it reacts with tourmaline powder and particles. Tourmaline showed lower absorption spectrum strength and transmittance at short wave, where absorption spectrum wavelength and strength were determined by the content of the composition elements and characteristics of crystallography. Increase of the Fe content has been confirmed to be the cause for the reduction of irradiation. For the chemical composition and spectral property of the tourmaline particle samples, it has been found that Si and Fe contents show positive correlation with Far-Infrared irradiation, while Al and Mg contents show negative correlation. For tourmaline powder, it has been confirmed that $^{17}O-NMR$ FWHM (full width at half maximum) decreases when reacts with distilled water. Tourmaline sauna (approximately $100^{\circ}C$) was found to increase $0.5-1.5^{\circ}C$ of body temperature, average of 12 heartbeat, and 10mg Hg of blood pressure. Tourmaline soap had very good aesthetic effect to skin and was confirmed to have above the average improvements to skin troubles (e.g., allergy or atopy).

Study on Reduction of Microbial Contamination on Daruma by Combination Treatment of Strong Acidic Hypochlorous Water and Ultrasonic Waves (강산성차아염소산수와 초음파를 병용처리한 조미오징어 반가공품의 미생물 오염도 저감화에 관한 연구)

  • Chung, Won-Hee;Ko, Jun-Soo;Shin, Il-Shik
    • Journal of Food Hygiene and Safety
    • /
    • v.30 no.2
    • /
    • pp.166-172
    • /
    • 2015
  • This study was performed to develop treatment method for reducing microbial contamination on Daruma (a semi-processed product of seasoned and dried squid) by combination of strong acidic hypochlorous water (SAHW) and ultrasonic waves (UW). The available chlorine concentration, oxidation reduction potential (ORP) and pH of SAHW were $69.67{\pm}0.58ppm$, $1071.33{\pm}4.16mV$ and 2.79, respectively. The 1.49 log CFU/g of viable cell count and 1.32 log CFU/g of Staphylococcus aureus was reduced, and Escherichia coli was reduced below detection limit when the Daruma was treated with 20 times (w/v) of sodium hypochlorite solution (SHS) for 120 min. The 3.62 log CFU/g of viable cell count and 3.22 log CFU/g of Staphylococcus aureus was reduced, and Escherichia coli was reduced below detection limit when the Daruma was treated with 20 times (w/v) of SAHW for 120 min. The antibacterial effects of SAHW were stronger than those of SHS at same available chroline concentration. SAHW treatment after washing strongly alkalic electrolyzed water (SAEW) showed better bactericidal effects than SAHW treatment only. The 4.0 log CFU/g of viable cell count was reduced, S. aureus was reduced below regulation limit (Log 2.0 CFU/g), and E. coli was reduced below detection limit when the Daruma was treated with 20 times (w/v) of SAHW for 90 min after washing with 20 times (w/v) of SAEW for 60 min. The viable cell number was reduced below detection limit and S. aureus was reduced below regulation limit when the Daruma was treated with 20 times (w/v) of SAHW for 60 min in ultrasonic washer. E. coli was reduced below detection limit when the Daruma was treated with 20 times (w/v) of SAHW for 10 min in ultrasonic washer. These results suggest that combination of SAHW and UW may be a good technique to reduce the microbial contamination in daruma.

Biological Hazard Analysis of Paprikas, Strawberries and Tomatoes in the Markets (유통중인 파프리카, 딸기 및 토마토의 생물학적 위해요소 분포 조사)

  • Yu, Yong-Man;Youn, Young-Nam;Hua, Quan Juan;Cha, Guang-Ho;Lee, Young-Ha
    • Journal of Food Hygiene and Safety
    • /
    • v.24 no.2
    • /
    • pp.174-181
    • /
    • 2009
  • The consumption of "ready-to-eat" agricultural products is recently increasing and the safety of these agricultural products is forefront of public concerns. The 120 samples of paprikas, strawberries and tomatoes, which are the representative exported agricultural products, were purchased at the department stores and discount stores in Daejeon. And we determined the microbiological and parasitological contamination level of these agricultural products using culture media, multiplex PCR, commercial bacterial detection kit and microscopy, and also evaluated the decontamination method. Mean counts of total aerobic bacteria from these agricultural products ranged from $1.3{\times}10^4$ CFU/g to $1.8{\times}10^5$ CFU/g, and mean counts of coliforms ranged from $1.4{\times}10^3$ CFU/g to $9.6{\times}10^3$ CFU/g. There was no significant difference in the level of bacterial contamination between the agricultural products from department stores and the ones from discount stores. Strawberry showed the highest contamination level for the bacteria and we also found the unidentified parasite eggs. Enterobacter cloacae was the most frequently isolated bacteria strain, but no food poisoning pathogenic bacteria except Staphylococcus aureus was isolated from the products by multiplex PCR. Compared to unwashed products, tab water-washed ones showed 80% decrease of the counts of total aerobic bacteria on the agricultural products, and the rates decreased more by incorporating detergent or ultrasonic wave treatment. We concluded that the biological contamination levels among paprikas, strawberries and tomatoes were the highest in strawberries, but there were not significant difference according to distribution systems.

EFFECT OF SMEAR LAYER ON THE APICAL LEAKAGE OF WARM VERTICAL CANAL FILLING (도말층이 가온 수직가업 근관 충전후 치근단 누출에 미치는 영향)

  • Kwon, Tae-Kyung;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.2
    • /
    • pp.561-574
    • /
    • 1998
  • The purposes of this study were to observe the difference in the root canal wall after hand instrumentation or engine-driven Ni-Ti instrumentation under the scanning electron microscope, and to evaluate the apical leakage provided by continuous wave of canal filling technique with or without root canal sealer and smear layer. Twenty recently extracted human maxillary anterior teeth were instrumented with K-type files or engine-driven Ni-Ti files, Quantec series 2000$^{TM}$ and irrigated with 5.25% NaOCl alone or 15% EDT A and final flush of 5.25% NaOCl. After the instrumentation and flushing, teeth were split in half with a knife and a mallet. They were then examined with a scanning electron microscope Forty-four recently extracted human maxillary anterior teeth were divided into four groups with and without smear layer and then warm vertical canal filling using System-B with or without sealer. The extent of leakage was scored after immersion in India ink for 1 week. The results were as follows: 1. No significant difference of smear layer was observed between K-type file-instrumented group and engine-driven Ni-Ti file-instrumented group. 2. A group without smear layer showed significantly less apical leakage than a group with smear layer when sealer was used for the canal filling (p<0.01). 3. There was no significant difference between a group without sealer and smear layer and a group without sealer and with smear layer (p<0.01). 4. In groups without smear layer, a group with sealer showed significantly less apical leakage than a group without sealer (p<0.01). 5. When root canals were irrigated with NaOCl alone, a group with sealer showed significantly less apical leakage than a group without sealer (p<0.01).

  • PDF

Survey of Heavy Metal Contents and Intake Rates After Decoction in Herbal Medicines Classified by Parts (한약재의 약용부위별 중금속 함량 및 탕 액에서의 이행률 조사)

  • Jung, Sam-Ju;Kang, Sung-Tae;Han, Chang-Ho;Kim, Su-Jin;Ko, Suk-Kyung;Kim, Yun-Hee;Kim, Yoo-Kyung;Kim, Bog-Soon;Choi, Byung-Hyun
    • Journal of Food Hygiene and Safety
    • /
    • v.25 no.4
    • /
    • pp.402-409
    • /
    • 2010
  • The study was conducted to estimate the contents of heavy metal in commercial herbal medicines (1047 samples of 132 species) which were collected from markets in Seoul and to analyze the contents of heavy metals of herbal medicines by classifying them by parts. The samples were digested using microwave method. The contents of heavy metal (Pb, Cd, and As) and Hg were determined using Inductively coupled plasma-Mass spectrometer (ICP/MS). And the contents of Hg were obtained by Mercury analyzer. The average values of heavy metal in herbal medicines were as follows [mean (minimum-maximum), mg/kg]; Pb 0.870 (ND-69.200), As 0.148 (ND-2.965), Cd 0.092 (ND-2.010), and Hg 0.007 (ND-0.B7). And the average values of heavy metal by parts in herbal medicines were as follows [mean (minimum-maximum), mg/kg]; Ramulus 2.046 (0.065-4.474), Herba 1.886 (0.048-10.404), Flos 1.874 (0.052-5.393), Cortex 1.377 (0.011-4.837), Radix 1.165 (0.012-70.111), Rhizoma 1.116 (0.016-5.490, Fructus 0.838 (0.017-4.527), Perithecium 0.729 (0.013-4.953), Semen 0.646 (0.006-4.416). The average values of heavy metal of imported herbal medicines except Radix were higher than domestic ones. By decoction of herbal medicines exceeding the tolerances, average intake rates of Pb, As, Cd and Hg were obtained as 6.1%, 40.3%, 4.7%, and 2.2%, respectively.

Computer Aided Diagnosis System for Evaluation of Mechanical Artificial Valve (기계식 인공판막 상태 평가를 위한 컴퓨터 보조진단 시스템)

  • 이혁수
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.421-430
    • /
    • 2004
  • Clinically, it is almost impossible for a physician to distinguish subtle changes of frequency spectrum by using a stethoscope alone especially in the early stage of thrombus formation. Considering that reliability of mechanical valve is paramount because the failure might end up with patient death, early detection of valve thrombus using noninvasive technique is important. Thus the study was designed to provide a tool for early noninvasive detection of valve thrombus by observing shift of frequency spectrum of acoustic signals with computer aid diagnosis system. A thrombus model was constructed on commercialized mechanical valves using polyurethane or silicon. Polyurethane coating was made on the valve surface, and silicon coating on the sewing ring of the valve. To simulate pannus formation, which is fibrous tissue overgrowth obstructing the valve orifice, the degree of silicone coating on the sewing ring varied from 20%, 40%, 60% of orifice obstruction. In experiment system, acoustic signals from the valve were measured using microphone and amplifier. The microphone was attached to a coupler to remove environmental noise. Acoustic signals were sampled by an AID converter, frequency spectrum was obtained by the algorithm of spectral analysis. To quantitatively distinguish the frequency peak of the normal valve from that of the thrombosed valves, analysis using a neural network was employed. A return map was applied to evaluate continuous monitoring of valve motion cycle. The in-vivo data also obtained from animals with mechanical valves in circulatory devices as well as patients with mechanical valve replacement for 1 year or longer before. Each spectrum wave showed a primary and secondary peak. The secondary peak showed changes according to the thrombus model. In the mock as well as the animal study, both spectral analysis and 3-layer neural network could differentiate the normal valves from thrombosed valves. In the human study, one of 10 patients showed shift of frequency spectrum, however the presence of valve thrombus was yet to be determined. Conclusively, acoustic signal measurement can be of suggestive as a noninvasive diagnostic tool in early detection of mechanical valve thrombosis.