• 제목/요약/키워드: Korean type building

검색결과 2,403건 처리시간 0.031초

Experimental Study on the Thermal Effect of BIPV Modules Depending on the Ventilation Type of PV Module Backside (후면 환기조건에 따른 건물외피용 태양광발전(BIPV) 모듈의 열적 영향에 관한 실험연구)

  • Yoon, Jong-Ho;Kim, Jae-Ung
    • Journal of the Korean Solar Energy Society
    • /
    • 제26권1호
    • /
    • pp.81-89
    • /
    • 2006
  • Building integrated photovoltaic (BIPV) system operates as a multi-functional building construction material. They not only produce electricity, but also are building integral components such as facade, roof, window and shading device. On the other hands lots of architectural considerations should be reflected such as Installation position, shading, temperature effect and so on. As PV modules function like building envelope in BIPV, combined thermal and PV performance should be simultaneously evaluated This study is on the combined thermal and PV performance evaluation of BIPV modules. The purpose of this study is to investigate a temperature effect of PV module depending on the ventilation type of PV module backside. Test cell experiment was performed to identify the thermal and power effect of PV modules. Measurement results on the correlation of temperature and power generation were obtained. Those results can be utilized for the development of optimal BIPV installation details in the very early design stage.

A Study on the Layout Patterns of Public Schools in Manhattan - Focused on Relationship between Manhattan Grid Plan and Open Space - (뉴욕시 공립학교에 나타난 배치 특성에 관한 연구 - 맨하튼 가로체계와 외부공간의 관계를 중심으로 -)

  • Kim, Pil-Soo;Jeon, You-Chang
    • Journal of the Korean Institute of Educational Facilities
    • /
    • 제20권2호
    • /
    • pp.3-14
    • /
    • 2013
  • The purpose of this study is to analyze patterns of public school building layout types, open space and relationship with communities in the Manhattan grid plan. The study illustrates how building layout patterns of school facilities are influenced by societal demands in the urban grid environment. During the nineteenth century, the Island of Manhattan was transformed into a physical representation of the Cartesian coordinate system via the development of the grid street plan. In order to take advantage of streets as urban space, it is quite important to understand characteristics of communities and open space relationships between buildings and streets. Moreover, the strategic planning of schools' outdoor space vitalizes public streets as a critical community anchor. This research reviews 118 Manhattan public schools and categorizes them by (1) building layout type, (2) site type, (3) circulation and public open space, which are the biggest factors that determine the layout patterns of the public schools in Manhattan. As a result of analysis, the layout patterns are classified into seven types : "ㅡ", "L", "ㄷ", "ㅁ", "H", "T" and "other" type. Of these, "ㅡ" type and "L" type occur most frequently, because these configurations most flexibly fit into the limited grid-locked blocks, the various types of site & topography, and adapt most dynamically to the open spaces created by using avenues and streets. The ultimate objective of this study is to provide a case study for future efforts to plan open spaces for campuses that effectively utilize the streets in proximity.

A Study on Standard Hanok Design for Rural (농촌 한옥 표준설계도 연구)

  • Kim, Jae-Ung
    • Journal of the Korean Institute of Rural Architecture
    • /
    • 제18권1호
    • /
    • pp.19-28
    • /
    • 2016
  • This research aimed to suggest a standard design that reflects Hanok design tendency, and present a selective design that can fulfill a building owner's intention beyond the simple function of building permit or report. In addition, this research attempted to become a standard by establishing a criterion in calculating the measurements of section design or primary framework members, in order to be a guideline for designing Hanok in different sizes and forms. The results are as follows. The building area of Hanok standard design was set to be below $85m^2$, with a straight type of $83.16m^2$ and an L-shape of $84.24m^2$. By dividing the plane into a straight type and L-shape, two straight types were suggested: 'general type' and 'large living room type.' The upper floor space, along with the main room and small room, was proposed as an option to be changed into a room where an underfloor heating is installed depending on the building owner's intention. In addition, a criterion for side design and calculation of framework measurements was suggested and applied, while a five-girder design without high pillars was suggested for material-assembling structure. Two types of pillars-circumference and square cylinder-were proposed for the building owner to choose from, and a pointed beam house and ikgong(orthogonally-projected bracket) house were suggested for pojak bracket structure so either of them could be chosen according to the building owner's taste and economic condition. Finally, the sectional size of main materials were divided according to the form of pojak bracket structure to be proposed.

An experimental study on performance comparison of waterproof concrete using admixture and penetrability waterproof admixture of concrete (구체방수와 침투성방수의 방수성능 비교에 대한 실험적 연구)

  • Park, Ki-Woo;Oh, Sang-Geun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 한국건축시공학회 2011년도 추계 학술논문 발표대회
    • /
    • pp.229-230
    • /
    • 2011
  • We could see that, the thinner the retaining wall is, the more advantageous Premixed Agent Type Waterproof method is in the aspect of economic efficiency. The reason is because, in the case of Premixed Agent Type Waterproof method, the thicker the retaining wall is, the higher the construction cost increases due to increase in the material quantity required which increases in proportion to the area in the case of Premixed Agent Type Waterproof method. We could see that, the thinner the retaining wall is, the more inferior the economic efficiency of Infiltration Type Waterproof method is to that of Premixed Agent Type Waterproof method, as, in the case of Infiltration Type Waterproof method, the quantity of material required is fixed in proportion to the area. Consequently, we concluded that Premixed Agent Type Waterproof method is economically advantageous up to the wall thickness of 700 mm and Infiltration Type Waterproof from 800 mm.

  • PDF

Cooling Performance of Ground source Heat Pump using Effluent Ground Water (유출지하수 열원 지열히트펌프시스템의 냉방성능)

  • Park, Geun-Woo;Nam, Hyun-Ku;Kang, Byung-Chan
    • New & Renewable Energy
    • /
    • 제3권4호
    • /
    • pp.47-53
    • /
    • 2007
  • Effluent ground water overflow in deep and broad ground space building. Temperature of effluent ground water is in $12{\sim}20^{\circ}C$ annually and the quality of that water is as good as living water. Therefore if the flow rate of effluent ground water is sufficient as source of heat pump, that is good heat source and heat sink of heat pump. Effluent ground water contain the thermal energy of surrounding ground. So this is a new application of ground source heat pump. In this study open type and close type heat pump system using effluent ground water was installed and tested for a church building with large and deep ground space. The effluent flow rate of this building is $800{\sim}1000ton/day$. The heat pump capacity is 5RT each. The heat pump cooling COP is $4.9{\sim}5.2$ for the open type and $4.9{\sim}5.7$ for close type system. The system cooling COP is $3.2{\sim}4.5$ for open type and $3.8{\sim}4.2$ for close type system. This performance is up to that of BHE type ground source heat pump.

  • PDF

Cooling Performance of Ground source Heat Pump using Effluent Ground Water (유출지하수 열원 지열히트펌프시스템의 냉방성능)

  • Park, Geun-Woo;Nam, Hyun-Ku;Kang, Byung-Chan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.471-476
    • /
    • 2007
  • Effluent ground water overflow in deep and broad ground space building. Temperature of effluent ground water is in $12{\sim}20^{\circ}C$ annually and the quality of that water is as good as living water. Therefore if the flow rate of effluent ground water is sufficient as source of heat pump, that is good heat source and heat sink of heat pump. Effuent ground water contain the thermal energy of surrounding ground. So this is a new application of ground source heat pump. In this study open type and c lose type heat pump system using effluent ground water was installed and tested for it church building with large and deep ground space. The effluent flow rate of this building is $800{\sim}1000$ ton/day. The heat pump capacity is 5RT each. The heat pump cooling COP is $4.9{\sim}5.2$ for the open type and $4.9{\sim}5.7$ for close type system. The system cooling COP is $3.2{\sim}4.5$ for open type and $3.8{\sim}4.2$for close type system. This performance is up to that of BHE type ground source heat pump.

  • PDF

Heating Performance of Ground source Heat Pump using Effluent Ground Water (유출지하수 열원 지열히트펌프시스템의 난방성능)

  • Park, Geun-Woo;Lee, Eung-Youl
    • New & Renewable Energy
    • /
    • 제3권2호
    • /
    • pp.40-46
    • /
    • 2007
  • Effluent ground water overflow in deep and broad ground space building. Temperature of effluent ground water is in $12{\sim}20^{\circ}...$ annually and the quality of that water is as good as well water. Therefore if the flow rate of effluent ground water is sufficient as source of heat pump, that is good heat source and heat sink of heat pump. Effuent ground water contain the thermal energy of surrounding ground. So this is a new application of ground source heat pump. In this study open type and close type heat pump system using effluent ground water was installed and tested for a church building with large and deep ground space. The effluent flow rate of this building is $800{\sim}1000\;ton/day$. The heat pump capacity is 5RT. The heat pump heating COP was $3.85{\sim}4.68$ for the open type and $3.82{\sim}4.69$ for the close type system. The system heating COP including pump power is $3.0{\sim}3.32$ for the open type and $3.32{\sim}3.84$ for close type system. This performance is up to that of BHE type ground source heat pump.

  • PDF

A Study on the Possibility of Model Development from Traditional Han-ok to Urban Clustering Housing Model in Korean Context (전통한옥의 도시집합주거로 발전 가능성 연구)

  • Shon, Seung-Kwang
    • Journal of the Korean housing association
    • /
    • 제19권3호
    • /
    • pp.71-81
    • /
    • 2008
  • A traditional Korean housing is a typical type which is contained life style, spatial organization and scape element of people who lived in Korea. In the hanok, people want to be live not only in human environment and traditional culture, but also modem urban housing as a high density. This article deals as follows: First, Hanok as urban housing would be composed in a housing lot, linear type layout, devide building, and cluster type. Second, Housing unit and configuration of Multi family housing can be used single story, second story, second story + single story, multi story and Hanok roofing. Thirds, structure of the building are traditional wooden, combined one of steel and wood or concrete and wood, and the building system in exterior and interior can be seperated into another system. Forth, Image of multi story Hanok A last, consistency of Hanok is not a repeat of an origin but application and creative aptitude of the origin, and multi family housing application of Hanok can be a trial creative.

A Study on the Status of Plan Type and Area at Elementary School Facilities - by Analyzing Architectural Plans - (초등학교(初等學校) 교사(校舍) 평면유형(平面類型) 및 면적(面積)의 현황(現況)에 관한 연구(硏究) - 평면도(平面圖)의 분석(分析)을 통해 -)

  • Rieu, Ho-Seoup
    • Journal of the Korean Institute of Educational Facilities
    • /
    • 제8권5호
    • /
    • pp.5-16
    • /
    • 2001
  • This paper presents results from analysis of architectural plan drawings of 355 elementary schools recently designed for 4 years. Theses plans are analyzed by factors such as local distribution, number of classes, type of plan, total construction area, area per a class, area per a student, and area status of each space. The purpose of this study is to provide fundamental resources for architectural designing and planning of elementary schools through finding trend and status of elementary school buildings that have no detailed data of area index. The results of this study are as follows: 1. As a result from analyzing number of classes in the surveyed schools, schools having 36 classes are dominant and schools having 72 classes are also shown. Average number of classes is 34.1. This result reflect s that elementary schools have been planned as large-scale schools. 2. In terms of type of plan, we found out that instead of disappearing traditional single corridor type building, the open school building that have multi-purpose spaces are mainly designed. In addition to that, there are few schools with large class rooms. 3. In the status of area of each school, they have much larger areas than areas provided by building guidelines. Secondly, there are some schools with two times area difference even though they have same class number. Therefore, it needs to adjust the school building guidelines to practical needs in the consideration of elementary school building for compulsory education. Though the plans of recently designed school for 4 year s are more differentiated than past, there are few schools planned by appropriate plan design and area distribution scheme. As a consequence, some improvements like improvement of building guidelines are desperate.

  • PDF

A Study on Public Announcement System for Property Right of Marine Architectural Building (해양건축물의 재산권 공시제도 정비방안 연구)

  • Lee, Han-Seok;Song, Hwa-Cheol;Jung, Dae
    • Journal of Navigation and Port Research
    • /
    • 제32권3호
    • /
    • pp.257-264
    • /
    • 2008
  • This study is intended to know what is the legal problems to settlement and public announcement of property right for construction of marine architectural building in Korea. Firstly, the situation and the prospect around marine architectural building are examined Secondly, the legal concepts of marine architectural building and the application of related laws are analyzed. Thirdly, the problems related to public announcement of property right of marine architectural building are suggested. Fourthly, some improvement schemes to solve the legal problems in relation with property right of buildings on the water at sea and ocean are proposed. As the conclusion, the marine architectural building can be divided into fixed-type and floating-type in order to find the proper way to handle the public announcement of property right for that sort of building. The fixed-typecan be registered as real estate according to the Building Law through the amendment of the existing related laws. But for the registration of floating-type building a new law should be made. In the near future, improvements on the legal system related with the settlement of property right of marine architectural building should be made, so that private sectors can join construction and operation of the building. Especially a new law for the floating-type marine architectural building should be made as soon as possible.