• 제목/요약/키워드: Korean squid

검색결과 892건 처리시간 0.042초

한국 동해의 살오징어(Todarodes pacificus) 어장변화 및 풍도와 동물플랑크톤 분포와의 관계 (Change in the Fishing Grounds and the Relationship between the Abundance of the Common Squid Todarodes pacificus and the Distribution of Zooplankton in the East Sea)

  • 황강석;강수경;오택윤;최광호;이동우
    • 한국수산과학회지
    • /
    • 제45권2호
    • /
    • pp.173-179
    • /
    • 2012
  • The common squid $Todarodes$ $pacificus$ is a dominant species in Korean waters, where it is captured preponderantly by the angling fishery. The spawning and nursery grounds of $T.$ $pacificus$ extend from the southern East Sea to the northern East China Sea. Consequently, the environmental conditions in this area during the spawning and nursery seasons might affect the abundance of $T.$ $pacificus$. This study, analyzed the relationship between the distribution of zooplankton and the abundance of $T.$ $pacificus$ and variation in the squid angling fishing grounds in Korean waters. There was a positive relationship between the fluctuations in zooplankton and the catch per unit effort (CPUE; $kg{\cdot}day^{-1}{\cdot}person^{-1}$) of the angling fishery in the East Sea of Korea. The main fishing season is from July to December and the CPUE was closely related to the zooplankton biomass in April in the East Sea. Recently, the center of the squid jigging ground has moved drastically from the area around Ulleung Island to the northern East Sea. We postulate that the fishing grounds of the squid angling fishery will move farther north with climate change.

Plerocercoids of Nybelinia surmenicola (Cestoda: Tentacularidae) in Squids, Todarodes pacificus, from East Sea, the Republic of Korea

  • Lee, Joon Yup;Kim, Ji Woon;Park, Gab Man
    • Parasites, Hosts and Diseases
    • /
    • 제54권2호
    • /
    • pp.221-224
    • /
    • 2016
  • A visceral helminth of the squid, Todarodes pacificus, is reported from the East Sea, the Republic of Korea. Total 39 squid samples were purchased from a fish market in Jumunjin-eup, Gangneung-si (City) from August 2014 to July 2015 and were examined for helminth parasites with naked eyes and under a stereomicroscope after opening the abdominal cavity with a pair of scissors. Whitish larval worms were mainly found in the stomach and abdominal cavity of the squid. They were detected in 25 (64.1%) out of 39 squids examined, and the infection density was 7 larvae per infected squid. Spatula-shaped larvae were $8.2{\times}2.0mm$ in average size, round to slightly flattened anteriorly, with round hatching posteriorly, and had characteristic 4 tentacles with numerous hooklets in the scolex. The larvae were identified as the plerocercoid stage of Nybelinia surmenicola by their morphological features. This finding represents a new host record and the first report of N. surmenicola infection in T. pacificus squids from the east coast of Korea.

진공조에 위치한 1차 SQUID 미분계를 이용한 헬멧형 뇌자도 장치의 제작 (A Helmet-type MEG System with $1^{st}$ order SQUID Gradiometer Located in Vacuum)

  • 유권규;김기웅;이용호
    • Progress in Superconductivity
    • /
    • 제11권1호
    • /
    • pp.78-82
    • /
    • 2009
  • We have fabricated a helmet type magnetoencephalogrphy(MEG) with a $1^{st}$ order gradiometer in vacuum to improve the signal-to-noise ratio(SNR) and the boil-off rate of liquid helium(LHe). The axial type first-order gradiometer was fabricated with a double relaxation oscillation SQUID(DROS) sensor which was directly connected with a pickup coil. The neck space of LHe dewar was made to be smaller than that of a conventional dewar, but the LHe boil-off ratio appeared to increase. To reduce the temperature of low Tc SQUID sensor and pickup coil to 9 K, a metal shield made of, such as copper, brass or aluminum, have been usually used for thermal transmission. But the metal shield exhibited high thermal noise and eddy current fluctuation. We quantified the thermal noise and the eddy current fluctuation of metal. In this experiment, we used the bobbin which was made of an alumina to wind Nb superconductive wire for pickup coil and the average noise of coil-in-vacuum type MEG system was $3.5fT/Hz^{1/2}$. Finally, we measured the auditory evoked signal to prove the reliability of coil-in-vacuum type MEG system.

  • PDF

Nb SQUID가 탑재된 초고감도 캔티레버 제작 (Fabrication of Nb SQUID on an Ultra-sensitive Cantilever)

  • 김윤원;이순걸;최재혁
    • Progress in Superconductivity
    • /
    • 제11권1호
    • /
    • pp.36-41
    • /
    • 2009
  • Superconducting quantum phenomena are getting attention from the field of metrology area. Following its first successful application of Josephson effect to voltage standard, piconewton force standard was suggested as a candidate for the next application of superconducting quantum effects in metrology. It is predicted that a micron-sized superconducting Nb ring in a strong magnetic field gradient generates a quantized force of the order of sub-piconewtons. In this work, we studied the design and fabrication of Nb superconducting quantum interference device (SQUID) on an ultra-thin silicon cantilever. The Nb SQUID and electrodes were structured on a silicon-on-insulator (SOI) wafer by dc magnetron sputtering and lift-off lithography. Using the resulting SOI wafer, we fabricated V-shaped and parallel-beam cantilevers, each with a $30-{\mu}m$-wide paddle; the length, width, and thickness of each cantilever arm were typically $440{\mu}m,\;4.5{\mu}m$, and $0.34{\mu}m$, respectively. However, the cantilevers underwent bending, a technical difficulty commonly encountered during the fabrication of electrical circuits on ultra-soft mechanical substrates. In order to circumvent this difficulty, we controlled the Ar pressure during Nb sputtering to minimize the intrinsic stress in the Nb film and studied the effect of residual stress on the resultant device.

  • PDF

고온초전도 SQUID 신호 검출을 위한 3채널용 FLL 회로 (Integrated 3-Channel Flux-Locked-Loop Electronics for the Readout of High-$T_c$ SQUID)

  • 김진목;김인선;유권규;박용기
    • Progress in Superconductivity
    • /
    • 제5권1호
    • /
    • pp.55-60
    • /
    • 2003
  • We designed and constructed integrated 3-channel flux-locked-loop (FLL) electronic system for the control and readout of high-T$_{c}$ SQUIDs. This system consists of low noise preamplifiers, integrators, interface circuits, and software. FLL operation was carried out with biased signals of 19 KHz modulated current and 150 KHz modulated flux, which are reconstructed as detected signals by preamplifier and demodulator. Computer controlled interface circuits regulate FLL circuit and adjust SQUID parameters to the optimum operating condition. The software regulates interface circuits to make an auto-tuning for the control of SQUIDs, and displays readout data from FLL circuit. 3-channel SQUID electronic system was assembled with 3 FLL-interface circuit boards and a power supply board in the aluminum case of 56 mm ${\times}$ 53 mm${\times}$ 150 mm. Overall noise of the system was around 150 fT/(equation omitted)Hz when measured in the shielded room, 200 fT/(equation omitted)Hz in a weakly shielded room, respectively.y.

  • PDF

비자기 차폐환경에서 미세자기신호 측정을 위한 고온 초전도 SQUID 자력계의 설계 및 제작 (Designs and Fabrications of High-TC SQUID Magnetometer for Measuring a Weak Signal without Magnetic Shielding)

  • 유권규;김인선;박용기
    • 센서학회지
    • /
    • 제13권2호
    • /
    • pp.110-113
    • /
    • 2004
  • We have designed and fabricated the YBCO single layer directly-coupled SQUID magnetometers for the purpose of magnetocardiography in a magnetically disturbed environment. The SQUID magnetometers were designed three different types of pickup coil such as solid type, PL type I and PL type II for further stable fluxed-locked-loop operation without magnetic shielding. Magnetometer was fabricated with a single layer YBCO thin film deposited on STO(100) bicrystal substrate with misorientation angle of $30^{\circ}$. We have achieved a magnetic field noise BN of 30 fT/$Hz^{1/2}$ at 100 Hz, and less than 70 fT/$Hz^{1/2}$ at 1 Hz. The PL type II SQUIDs have exhibited the most stable fluxed-locked-loop operation in a magnetically unshielded environment.

생체자기 응용을 위한 사파이어 기판 위에 제작된 YBCO dc SQUID 의 특성 (Characterization of YBCO do SQUID fabricated on sapphire substrate for biomagnetic applications)

  • 임해용;김인선;김동호;박용기;박종철
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 2000년도 High Temperature Superconductivity Vol.X
    • /
    • pp.155-159
    • /
    • 2000
  • YBCO step-edge dc SQUID magnetometers on sapphire substrates have been fabricated. CeO2 buffer layer and YBCO films were deposited in situ on the low angle (${\sim}$35$^{\circ}$) steps formed on the sapphire substrates. Typical 5-${\mu}$m-wide junction has R$_n$ of 5 ${\omega}$ and I$_c$ of 50 ${\mu}$A with large I$_c$R$_n$ product of 250 ${\mu}$V at 77K. According to applied bias current, depth of voltage modulation was changed and maximum voltage was measured 16 ${\mu}$V. Field noise of do SQUID was measured 100${\sim}$300 fT/${\surd}^{Hz}$ in the 1 $^{kHz}$, and about 1.5 pT/${\surd}^{Hz}$ in the 1/f region. For ac bias reversal method, field noise was decreased in the 1/f region. The QRS peak of magnetocardiogram was measured 50 pT in the magnetically shielded room.

  • PDF

SQUID 2차미분기 성능 평가용 균일자기장 및 2차 미분 자기장 발생원 (Sources of uniform and 2nd-order gradient fields for testing SQUID performance)

  • 이순걸
    • Progress in Superconductivity
    • /
    • 제8권2호
    • /
    • pp.152-157
    • /
    • 2007
  • Uniaxial square Helmholtz coils for testing SQUID sensors were designed and their field distributions were calculated. Optimum parameters for maximizing the uniform region in the Helmholtz mode were obtained for different uniformity tolerances. The coil system consists of 2 pairs of identical square loops, a Helmholtz pair for generating uniform fields and the other for the 2nd-order gradient fields in combination with the Helmholtz pair. Full expressions of the axial component of the field were calculated by using Biot-Savart's law. To understand the behavior of the field near the coil center, analytical expressions were obtained up to the 4th-order in the midplane and along the coil axis. The Helmholtz condition for generating uniform fields was calculated to be $d/{\alpha}=0.544505643$, where 2d is the inter-coil distance and $2{\alpha}$ is the side length of the coil square. Maximized uniform range can be obtained for a given nonuniformity tolerance by choosing $d/{\alpha}$ slightly lower than the Helmholtz condition. The pure second-order gradient field can be generated by subtracting the Helmholtz field from the field of the 2nd pair with equal magnitudes of the center fields of the two pairs. The coil system is useful for testing balance and sensitivity of SQUID gradiometers.

  • PDF