• Title/Summary/Keyword: Korean inclination

Search Result 1,592, Processing Time 0.021 seconds

Influences of Short-term High-heeled Walking on the Activities of Ankle-stabilizing Muscles in Healthy Young Females (단시간 하이힐 보행이 젊은 여성의 발목 주위근의 근 활성도에 미치는 영향)

  • Kim, Eun-ji;Jeon, Seol-bin;Jeong, Ki-yong
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.21 no.2
    • /
    • pp.39-46
    • /
    • 2015
  • Background: The purpose of this study was to investigate the influence of short-term treadmill walking with high-heeled shoes on electromyography activities of the medial gastrocnemius, lateral gastrocnemius and tibialis anterior in healthy young females. Methods: Fifteen healthy females were recruited for this study. To measure muscle activation, the subjects were asked in random order to walk on a treadmill using either high-heeled shoes or barefoot conditions. The shoe heel height for high-heeled walking was 7 cm. The walking speed on the treadmill was 4 km/h, and the inclination rate of the treadmill was 10%. The subjects performed treadmill walking in the barefoot and high-heeled walking conditions for 5 minutes. Electromyography data were collected from the tibialis anterior, medial gastrocnemius, lateral gastrocnemius, and soleus on both firm and foam surfaces and during eyes-open and-closed conditions while standing. Results: Tibialis anterior activity was significantly different before and after the walking task while standing on a foam surface with eyes closed (p<.05). Conclusion: This finding suggests that the activity of the tibialis anterior may be lowered after high-heeled walking. Therefore, high-heeled shoes contribute to harmful effects at the ankle joints, increasing the risks of falling and musculoskeletal injury.

  • PDF

FINITE ELEMENT ANALYSIS OF STRESS PATTERNS ON PERIODONTIUM OF SPLINTED ABUTMENTSFOR DISTAL EXTENSION REMOVABLE PARTIAL DENTURE (후방연장 국소의치에서 지대치의 splinting에 따른 치주조직의 응력 변화에 관한 유한요소법적 연구)

  • Hwang, Jae-Woong;Chang, Ik-Tae;Kim, Kwang-Nam
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.2
    • /
    • pp.241-268
    • /
    • 1995
  • Splint therapy, the immobilization of teeth, has been done for patient's masticatory comforts and an adjunctive aid in periodontal therapy. Mandibular premolars are frequently splinted in many distal extension removable partial denture cases. But splinting is an extensive restoration that may not be conservative of tooth structure and may prove to be quite costly to the patient. The two dimensional finite element analysis method was used to determine the magnitude and mode of distribution of the stresses of the periodontal ligament and supporting alveolar bone when abutments with different periodontal supports were splinted and distal-extension removable partial denture was subjected to different loading schemes. The results were as follows : 1. When abutments were splinted, stresses moved from apico-distal to apico-mesial of terminal abutment on a vertical force and from disto-alveolar crest to apex on a distally directed force. But stresses were generally diminished on a mesially directed force. 2. As vertical bone loss was proceeding, most of stresses were transmitted to residual ridge and the rest of stresses were concentrated on apex of distal abutment. But these apical stresses were minimized when abutments were splinted. 3. As mesially inclined bone loss was proceeding, it seemed to be dangerous that many stresses were concentrated on the distal alveolar crest, especially in the distally directed load case. Abutments splinting decreased the alveolar crestal stresses but not enough. 4. For all vertical stresses were effectively decreased on splinting, stresses were concentrated as highly on apico-mesial area of distal abutment in distally directed load cases as the distal inclination of bone level was severe. 5. The directions and magnitudes of abutment movements were decreased with teeth splinting.

  • PDF

A COMPARATIVE ANALYSIS OF THE ACCURACY OF IMPLANT IMPRESSION TECHNIQUES BY USING STRAIN GAUGE (Strain gauge를 사용한 임플랜트 인상법의 정확도 비교)

  • Han, Eu-Taek;Kim, Yung-Soo;Kim, Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.3
    • /
    • pp.539-549
    • /
    • 1995
  • The purpose of this study was to determine the accuracy of 3 implant impression methods by using strain gauge. The models used for this study were partially edentulous mandibular acrylic resin casts Model A, with two abutment analogs in #46,47 extraction site, represented two implant parallel to to the adjacent natural tooth. Model B represent an anterior implant parallel to the adjacene natural tooth and a posterior implant exhibiting a 15-degree lingual inclination. Master framework were fabricated on the master model, and 3 strain gauges were attached to a master framwork to determine the passivity of fit of the framework to sample casts made by the three impression techniques. The master framework was attached to each sample cast with gold screws, which were tightened with the torque driver to ensure a consistent toque application of 10 Ncm. Universal Digital Measuring System UCAM-5BT was used for strain measuring. Impression techniques studid were : 1. unsplinted tapered impression coping, polyvinyl siloxane, stock tray 2. unsplinted squared impression coping, polyether, custom tray 3. squared impression coping splinted with Duralay resin, polyether, custom tray Through analysis on data from this study, the following conclusions were obtained. 1. There were no statistically significant differences between the mean strain recorded from the sample casts made with the tree impression. But only strain values of model A(parallel group) Y-axis was signifcantly differed between Technique 1 and 3(P<0.05). 2. There was no statistically significant difference between model A(parallel group) and model B(15-degree divergent group).

  • PDF

A COMPARISON OF LOAD TRANSFER IN SCREW- AND CEMENT-RETAINED IMPLANT FIXED PARTIAL DENTURE DESIGNS (임플랜트 상부 보철물의 고정 방식에 따른 힘의 분포에 관한 연구 : 나사 유지형 대 시멘트 유지형)

  • Lee Joo-Hee;Kim Chang-Whe;Kim Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.2
    • /
    • pp.125-145
    • /
    • 2001
  • To compare the stress distribution patterns between cement-retained and screw-retained implant supported fixed prostheses according to four different abutment types, a three dimensional finite element analysis was performed. The hypothetical three unit fixed partial denture case was modelled on the three implants(10mm length and 3.75 diameter) in mandibular bone. Four angles of implantation(vertical, 10, 15 and 20 degree inclined mesially) were created and three different directions of force (vertical, oblique, horizontal) were applied at the center of the second premolar and distal end of the first molar for each cases. Within the limits of this study, the results were as follows, 1. In vertically installed cases, the more stress was concentrated at upper components, but mesially inclined cases, the more stress was concentrated at cortical bone. 2, The more inclined mesially the more stress was observed, especially at cortical bone. 3. The cement-retained models showed lower principal stress and more even stress distribution than the screw-retained models. 4. The similar stress distribution pattern was showed in model 1 and model 2, model 3 and model 4. 5. The more stress was observed when the loads were applied at the distal end of 1st molar than the center of 2nd premolar. 6 The fixture and the model as a whole, lesser stress values were observed when vertical loads were applied as compared to horizontal and oblique loads.

  • PDF

THREE-DIMENSIONAL STRESS ANALYSIS OF IMPLANT SYSTEMS IN THE MANDIBULAR BONE WITH VARIOUS ABUTMENT TYPES AND LOADING CONDITIONS (임프란트의 상부구조물 형상과 하중조건에 따른 3차원 유한요소해석을 이용한 하악골의 응력분포에 관한 연구)

  • Shin Ha-Shik;Chun Heoung-Jae;Han Chong-Hyun;Lee Soo-Hong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.5
    • /
    • pp.617-625
    • /
    • 2003
  • Statement of problem : There are many studies focused on the effect of shape of futures on stress distribution in the mandibular bone. However, there are no studies focused on the effect of the abutment types on stress distribution in mandibular bone. Purpose : The purpose of this study is to investigate the effect of three different abutment types on the stress distributions in the mandibular bone due to various loads by performing finite element analysis. Material and method : Three different implant systems produced by Warantec (Seoul, Korea), were modeled to study the effect of abutment types on the stress distribution in the mandibular bone. The three implant systems are classified into oneplant (Oneplant, OP-TH-S11.5). internal implant (Inplant, IO-S11.5) and external implant (Hexplant, EH-S11.5). All abutments were made of titanium grade ELI. and all fixtures were made of titanium grade IV. The mandibular bone used in this study is constituted of compact and spongeous bone assumed to be homogeneous, isotropic and linearly elastic. A comparative study of stress distributions in the mandibular bone with three different types of abutment was conducted. Results : It was found that the types of abutments have significant influence on the stress distribution in the mandibular bone. It was due to difference in the load transfer mechanism and the size of contact area between abutment and fixture. Also the maximum effective stress in the mandibular bone was increased with the increase of inclination angle of load. Conclusion : It was concluded that the maximum effective stress in the bone by the internal implant was the lowest among the maximum effective stresses by other two types.

Evaluation of the Numerical Liquefaction Model Behavior with Drainage Condition (배수조건에 따른 액상화 수치모델의 거동평가)

  • Lee, Jin-Sun;Kim, Seong-Nam;Kim, Dong-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.11
    • /
    • pp.63-74
    • /
    • 2019
  • Numerical liquefaction model and response history analysis procedure are verified based on dynamic centrifuge test results. The test was a part of the Liquefaction Experiments Analysis Project (LEAP). The model ground was formed inside of rigid box by using the submerged Ottawa F65 sand with a relative density of 55% and 5° of surface inclination. A tapered sinusoidal wave with a frequency of 1 Hz was applied to the base of the model box. Numerical analyses were performed by two dimensional finite difference method in prototype scale. The soil is modeled to show hysteretic behavior before shear failure, and Mohr-Coulomb model is applied for shear failure criterion. Byrne's liquefaction model was applied to track the changes in pore pressure due to cyclic loading after static equilibrium. In order to find an appropriate flow condition for the liquefaction analysis, numerical analyses were performed both in drained and undrained condition. The numerical analyses performed under the undrained condition showed good agreement with the centrifuge test results.

Changes of Western Men′s Underclothes - in the First Half of the 20C - (서양 남성 속옷의 변천에 관한 고찰 - 20세기 전기 -)

  • 김주애
    • Journal of the Korean Society of Costume
    • /
    • v.50 no.5
    • /
    • pp.53-64
    • /
    • 2000
  • The purpose of this study was to investigate the historical changes of western men's underclothes in the first half of the 20C and analyze functions and features of men's underclothes. This study was to utilize many literatures in the analysis of historical changes of western men's underclothes. In the 1900's, the attached collar was giving place to the detachable, and the coloured shirt for day wear was becoming accepted. The correct wear fur various occasions was given. Double collar was the favourite for day wear. The dress-shirt protector worn over the dress-shirt front. Men preferred to vest and pants in one as a combined garment. In the 1910's, underclothes were permitting freer movement, but what was still more significant was the glowing inclination to reduce the layers which covered the body. The new conception of decency which was beginning to appear continued to characterize underclothing the symbols of social rank, expect for formal occasion, were declining. For day the white shirt was being displaced by the soft-fronted shirt. In the 1927-1930's, Underclothes were reduced in number, extent and thickness. Underclothing had lost two of its original function : it no longer preserved the warmth of the body, nor did it disguise its essential shape. Both sexes discarded the use of white underwear, In the 1930's, men saw an increasing preference for the coloured shirt. Combinations became increasingly popular and the singlet were displacing the under-vest in the 1930's. All undergarments were very commonly in natural colours. In the 1940's, for evening dress. shirt was plain linen front and square cuffs. Short trunks reached to mid-thigh, had a front waist yoke with three button fastening. Underclothes were pursued ease and activity.

  • PDF

A Study of the Young Aged Women′s Bust (청년기 여성의 상반신 체형 연구)

  • 엄정옥;문명옥
    • Journal of the Korean Society of Costume
    • /
    • v.50 no.5
    • /
    • pp.117-130
    • /
    • 2000
  • The purpose of this thesis is to offer basic data for clothing design which is intended to apply appropriate shape and capacity to clothes. The following are the analyzed results of an investigation which was conducted to characterize the upper half of the female body of 193 women whose ages are 18 to 25, taking part in this investigation. According to the results of analyzing young women's bust, I came to find a large individual difference of the wide varying factor numbers at the items of the side feature, the body stance, and the dart quantity. For the analysis of the female's upper body, 11 factors are used. The are as follows: Factor 1. width of the bust Factor 2. height of the bust and length of the arm Factor 3. side thickness of the bust and the upside type Factor 4. length of the bust on the front Factor 5. length of the bust on the back Factor 6. salient ratio of the breast Factor 7. width of the neck. the armhole, and measurement of the droop Factor 8. length of the shoulder Factor 9. flat ratio of the bust Factor 10. inclination of the shoulder factor 11. form of the back The shape of young women's upper bodies can be divided into four groups. The character ization of each group are as follows : Group 1 . 28.5% of the women who take part in this investigation belong to Group 1 These women have the shortest body, with a longer length of the front than the back and more thickness on the front than the back. Group 2. 21.1% of the women who take part in this investigation belong to this group. They show a longer length of the back and more thickness of the back than the front. In addition, this group is bent forward. Group 3. This group is the mast common type, showing the shortest and thickest character. 37.8% of the women who take part in this investigation have this bust character Group 4. 12.4% of the women belong to Group 4. They possess the highest and fattest character, skewing smaller necks, armholes, and waists than the other groups. This group also shows the drooping shoulders.

  • PDF

A Comparative Study of Safe Factor of Slope according to Analysis Methods (해석 방법에 따른 비탈면 최소안전율 비교 연구)

  • Ryu, Hang Taek;Jang, Jeong Wook;Chung, Youn In
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.30 no.5
    • /
    • pp.207-216
    • /
    • 2018
  • This research compared and analyzed safety ratio of slope with Talren97 and SoilWorks based on limit equilibrium analysis and Midas GTS based on finite element analysis. For the analysis variables, there are slope height, berm condition, soil parameter, groundwater level, slope inclination. All of slope stability analysis were performed by dividing into dry season and rainy season. As the result of the analysis of Talren97 and SoilWorks based on same theory, safety ratio of slope shows same value, so there was no difference between the programs. In comparison with limit equilibrium analysis, the result of finite element analysis showed somewhat high ratio of safety and it was higher by about 2.4% averagely. The difference between the result of limit equilibrium analysis and that of finite element analysis is in the range which can ignored in practical work.

Habitat Quality Valuation Using InVEST Model in Jeju Island (InVEST 모델을 이용한 서식처 가치 평가 - 제주도를 중심으로 -)

  • Kim, Teayeon;Song, Cholho;Lee, Woo-Kyun;Kim, Moonil;Lim, Chul-Hee;Jeon, Seong Woo;Kim, Joonsoon
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.18 no.5
    • /
    • pp.1-11
    • /
    • 2015
  • Jeju Island is managed intensively in terms of environmental and ecological aspect because of its extraordinary ecosystem types comprising numerous rare, protected flora and fauna. To depict rapid change of habitat status in Jeju Island, the InVEST Habitat Quality model has been operated and compared analytically with the Eco-Natural map. The Habitat Quality map of Jeju Island is turned out to have similar inclination with Eco-Natural map. We compared the average habitat quality value in each Eco-natural map class in Jeju Island and the habitat quality value of first second third grade and non-included area decreased as 0.95 0.76, 0.53 and 0.37 in eco natural map respectively. Compared to biodiversity map based on biological investigation, the result of the InVEST habitat quality model can be simply obtained by land cover map with threat and sensitivity data. Further studies are needed to make explicit coefficients for Jeju Island and Korean peninsula, then the Habitat Quality model could be applied to past and future scenarios to analyze extent of habitat degradation in time series to help decision makers.