• Title/Summary/Keyword: Korean images

Search Result 18,243, Processing Time 0.048 seconds

f-MRI with Three-Dimensional Visual Stimulation (삼차원 시각 자극을 이용한 f-MRI 연구)

  • Kim C.Y.;Park H.J.;Oh S.J.;Ahn C.B.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.9 no.1
    • /
    • pp.24-29
    • /
    • 2005
  • Purpose : Instead of conventional two-dimensional (2-D) visual stimuli, three-dimensional (3-D) visual stimuli with stereoscopic vision were employed for the study of functional Magnetic Resonance Imaging (f-MRI). In this paper f-MRI with 3-D visual stimuli is investigated in comparison with f-MRI with 2-D visual stimuli. Materials and Methods : The anaglyph which generates stereoscopic vision by viewing color coded images with red-blue glasses is used for 3-D visual stimuli. Two-dimensional visual stimuli are also used for comparison. For healthy volunteers, f-MRI experiments were performed with 2-D and 3-D visual stimuli at 3.0 Tesla MRI system. Results : Occipital lobes were activated by the 3-D visual stimuli similarly as in the f-MRI with the conventional 2-D visual stimuli. The activated regions by the 3-D visual stimuli were, however, larger than those by the 2-D visual stimuli by $18\%$. Conclusion : Stereoscopic vision is the basis of the three-dimensional human perception. In this paper 3-D visual stimuli were applied using the anaglyph. Functional MRI was performed with 2-D and 3-D visual stimuli at 3.0 Tesla whole body MRI system. The occipital lobes activated by the 3-D visual stimuli appeared larger than those by the 2-D visual stimuli by about $18\%$. This is due to the more complex character of the 3-D human vision compared to 2-D vision. The f-MRI with 3-D visual stimuli may be useful in various fields using 3-D human vision such as virtual reality, 3-D display, and 3-D multimedia contents.

  • PDF

Multi-Component Relaxation Study of Human Brain Using Relaxographic Analysis (Relaxographic 분석법을 이용한 뇌의 다중 자기이완특성에 관한 연구)

  • Yongmin Chang;Bong Soo Han;Bong Seok Kang;Kyungnyeo Jeon;Kyungsoo Bae;Yong-Sun Kim;Duk-Sik Kang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.2
    • /
    • pp.120-128
    • /
    • 2002
  • Purpose : To demonstrate that the relaxographic method provides additional information such as the distribution of relaxation times and water content which are poentially applicable to clinical medicine. Materials and Methods : First, the computer simulation was performed with the generated relaxation data to verify the accuracy and reliabilility of the relaxographic method (CONTINI). Secondly, in or der to see how well the CONTIN quantifies and resolves the two different ${T_1}$ environments, we calculated the oil to water peak area ratios and identified peak positions of ${T_1}-distribution$ curve of the phantom solutions, which consist of four centrifugal tubes (10 ml) filled with the compounds of 0, 10, 20, 30% of corn oil and distilled water, using CONTIN. Finally, inversion recovery MR images for a volunteer are acquired for each TI ranged from 40 to 1160 msec with TR/TE=2200/20 msec. From the 3 different ROIs (GM, WM, CSF), CONTIN analysis was performed to obtain the ${T_1}$-distribution curves, which gave peak positions and peak area of each ROI location. Results : The simulation result shows that the errors of peak positions were less in the higher peak (centered ${T_1}=600$ msec) than in the lower peak (centered ${T_1}=150$ msec) for all SNR but the errors of peak areas were larger in the higher peak than in the lower peak. The CONTIN analysis of the measured relaxation data of phantoms revealed two peaks between 20 and 60 msec and between 500 and 700 msec. The analysis gives the peak area ratio as oil 10%: oil 20%: oil 30% = 1:1.3:1.9, which is different from the exact ratio, 1:2:3. For human brain, in ROI 3 (CSF), only one component of -distributions was observed whereas in ROI 1(GM) and in ROI 2 (WM) we observed two components of ${T_1}-distribution$. For the WM and CSF there was great agreement between the observed ${T_1}-relaxation$ times and the reported values. Conclusion : we demonstrated that the relaxographic method provided additional information such as the distribution of relaxation times and water content, which were not available in the routine relaxometry and ${T_1}/{T_2}$ mapping techniques. In addition, these additional information provided by relaxographic analysis may have clinical importance.

  • PDF

Magnetic Resonance Voiding Cystography in the Diagnosis of Vesicoureteral Reflux: Comparative Study with Voiding Cystourethrography (방광요관역류의 진단에 있어서 자기공명 배뇨성 방광조영술의 유용성: 태뇨성 요도방광조영술과의 비교연구)

  • Lee, Sang-Kwon;Chang, Yong-Min;Koo, Ja-Hoon;Ko, Cheol-Woo;Chung, Sung-Kwang;Kim, Tae-Hun;Sohn, Kyung-Sik;Lee, Chang-Hyun;Kim, Young-Hwan
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.2
    • /
    • pp.85-93
    • /
    • 2000
  • Purpose: To evaluate the availability of magnetic resonance (MRI voiding cystography for the diagnosis of vesicoureteral reflux (VUR) and to compare the sensitivity of MR voiding cystography (MRVC) with that of radiographic voiding cystourethrography (VCUG) in the detection of VUR. Material and Methods : MRVC was performed upon 20 children referred for investigation of VUR. Either coronal T1-weighted spin-echo or spoiled gradient-echo images were obtained before and after transurethral administration of a mixture of normal saline and gadopentetate dimeglumine, and immediately after voiding. The findings of MRVC were compared with those of VCUG performed within 6 months of MRVC. Results 1 VUR was detected in 23 ureterorenal units f16 VUR's by both methods, five VUR's by VCUG, and two VUR's by MRVC). The sensitivity of VCUG and MRVC in detecting VUR was 91.3% (21/23) and 78.3% (18/23), respectively. MRVC detected renal scarring in 15 out of 17 kidneys with scintigraphically detected renal scarring. Conclusion : Although MRVC is slightly less sensitive than VCUG in the detection of VUR, it can be used for the diagnosis of VUR and renal scarring simultaneouslyl and thus will reduce the radiation hazard.

  • PDF

Measurement of Regional Cerebral Blood Volume in Normal Rabbits on Perfusion-weighted MR Image (MR 관류강조영상에서 정상 가토의 국소 뇌혈류량 측정)

  • 박병래;예수영;나상옥;김학진;이석홍;전계록
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.2
    • /
    • pp.100-106
    • /
    • 2000
  • Purpose : To evaluate the usefulness of cerebral blood flow measurement applied to perfusion weighted image with short-scan time single shot gradient echo-planar technique in measuring cerebral blood volume(rCBV) of normal rabbits. Materials and methods : With 2.1-3.6 kg weighted rabbits, image is acquired when they are in supine position in children positioner. Perfusion weighted image is acquired to 44 seconds per 1 second successively. After 4 seconds later, Gd-DTPA 2ml are injected into int. jugular vein with 2 ml per second and normal saline is also injected after that. Same technique is applied 2 times per 30 minites in same rabbit. After Image is obtained in two part of cerebral cortex at vertex, convexity, in one of basal ganglia with choosing about $3-5{\textrm{mm}^2}$ areas. Curve of signal intensity changes in time sequence is drawn. After this images are transmitted by PC and software IDL, regional cerebral blood volume is measured with imaging processing program made by us. Results : With 22 of 24 rabbits, satisfactory 1-2 signal intensity versus time curve is made. Cerebral blood capacity and contrast media stay time (ST) is measured in two cerebral cortex and basal ganglia refering in parietal cerebral cortex. Mean focal cerebral blood flow capacity ratio in cortex was $0.97{\pm}0.35$ and in basal ganglia, $0.99{\pm}0.37$, mean contrast media stay time in cortex was $9.83{\pm}1.63$ sec and in basal gaiglia, $9.42{\pm}1.14$ sec, but there was no statistically significant difference between two areas ($\rho$=0.05). Conclusion : In cerebral cortex and basal ganglia, there is no difference in mean focal blood volume and mean contrast stay time. Therefore, PWI is useful in cerebral blood flow and early diagnosis, prognosis of cerebral ischemic disease. Hereafter, it is helpful in analysing cerebral blood flow changes with comparison difference in rCBV between normal tissue and ischemic tissue, and that with DWI finding in infarcted patient.

  • PDF

The Comparison between Single Shot Turbo Spin Echo and B-FFE (Balanced Turbo Field-echo) in the Differentiation of Focal Liver Lesions (국소 간병변 감별에서 단발고속스핀에코 기법과 균형항정상 태세차를 이용한 고속영역 기법간의 비교)

  • Kim, Young-Chul;Kim, Myeong-Jin;Cha, Seung-Whan;Chung, Yong-Eun;Han, Kwang-Hyup;Choi, Jin-Sub
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.1
    • /
    • pp.39-48
    • /
    • 2007
  • Purpose : To determine the diagnostic accuracy of four different sequences : moderately T2 weighted, two heavily T2-weighted single shot turbo spin-echo sequence and breath-hold axial-2D balanced turbo field-echo sequence(bFFE) for characterization of focal lesions. Materials and Methods : During the 3-month period between June and August 2005, seventy-six patients were proved to have ninety-three focal hepatic lesions on MR imaging. The patients consisted of 49 men and 27 women (age range, 15-75 years; mean age, 56.23 years). All MR images were acquired on a 1.5-T MR using the following sequences: 1. A breath-hold axial T2-weighted single shot turbo spin-echo sequence, 2. a breath-hold axial-2D balanced turbo field-echo sequence. Two radiologists performed quantitative analysis. Another radiologist measured the lesion-to-liver contrast-to-noise ratio at the region-of-interest in the four sequences. Results : There was no significant difference in inter-observer variability between the four sequences. The accuracy for both cyst and malignancy of moderate T2 weighted MRI (echo time: 80 msec) was also highest. There was significant difference for lesion characterization between moderate T2 weighted MRI and balanced steady state procession (p-value: 0.004) in the second reader. For longer echo time, the CNR of cystic lesions were markedly increased in comparison to lesions of other component. Conclusion : The accuracy and inter-observer variability of single shot turbo spin echo T2 weighted sequence was higher than bFFE. Although there was no statically significant difference, moderate T2 weighted MRI (echo time: 80 msec) was more accurate than heavily T2 weighted sequence (echo time: 300 msec). If the results for lesion characterization is equivocal in TE 80, the addition of heavily T2 weighted MRI (echo time: 180 msec) can be helpful.

  • PDF

Mucoid Degeneration of Anterior Cruciate Ligament: Correlation between MR Imaging and Pathologic Findings in Patients with Osteoarthritis of the Knee (앞십자 인대의 점액 변성: 슬관절 퇴행성 관절염 환자에서 MRI 소견과 병리소견의 연관)

  • Ryu, Jeong-Ah;Liew, Hyun-Jeong;Kim, Sung-Moon;Shin, Myung-Jin;Shin, Hee-Jung;Cho, Kyung-Ja;Cho, Woo-Shin;Kang, Chang-Ho;Lee, Min-Hee;Kim, Mi-Sung;Park, Noh-Hyuck;Lee, Sang-Hoon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.1
    • /
    • pp.27-32
    • /
    • 2007
  • Purpose : To evaluate the mucoid degeneration (MD) of the anterior cruciate ligament (ACL) of the knee by correlation of MRI findings with pathology, in the patients with osteoarthritis (OA). Materials and Methods : This study included 17 patients (mean 68.8 years old) who underwent preoperative MRI. In proton density-weighted sagittal and coronal images ACLs were evaluated for the thickness and signal intensity (SI). Total knee replacement arthroplasty was performed and the pathologic findings of ACL were evaluated. MD was classified as 3 grades according to the degenerated amount in microscopy. Thickness and SI was evaluated as normal or increased on MRI. Results : All of the 4 patients who showed thickened ACL showed increased SI on MRI. All of the 8 patients with increased SI of the ACL on MRI had MD in the ACL. However, remained 9 patients also had MD, in spite of their normal thickness and SI on MRI. Calcification was seen in 5 patients. Conclusion : Eight cases who showed ACL thickening or increased SI on MRI were well correlated with MD, however, because the other nine cases who showed normal thickness and normal SI of ACL on MRI also showed MD in pathology, normal MRI finding should not exclude the possibility of MD of ACL.

  • PDF

Assessment of Carotid Geometry by Using the Contrast-enhanced MR Angiography (조영증강 MR 혈관 조영술을 이용한 경동맥 기하학의 평가)

  • Lee, Chung-Min;Ryu, Chang-Woo;Kim, Keun-Woo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.14 no.1
    • /
    • pp.47-55
    • /
    • 2010
  • Purpose : To evaluate the geometry of carotid artery by assessing the images of contrast-enhanced MR angiography (CE-MRA) and interrelationships between the geometry of carotid artery and clinical factors. Materials and Methods : 216 consecutive patients who performed supraaortic CE-MRA with fast spoiled gradient-echo imaging were included. Their medical records were reviewed for variable information including risk factors predictive of generalized atherosclerotic disease (age, hypertension (HTN), diabetes mellitus, hyperlipidema, and smoking), sex, body weight, height, and body mass index (BMI). We reviewed the CE-MRA with carotid origin (3 types), carotid artery tortuosity, angle of internal carotid artery bifurcation, the type of aortic arch branching, and the presence of the coiling of carotid artery. Results : Multinomial logistic regression analysis showed that significantly contributed clinical backgrounds for carotid origin were the age and the BMI. With an increase of age at 1, the probability that the type of carotid origin become from type 1 to type 2 was 0.9 times (p=0.004) in right carotid artery (RCA), 0.9 times (p = 0.031) in left carotid artery (LCA), 0.9 times that are likely to be type3 from type 2 (p<0.001) in RCA and 0.9 times in LCA (p=0.009). Increase in BMI at 1 increased odds of becoming type 2 as 1.1 times (p = 0.067) in RCA, 1.1 times (p=0.009) in LCA and increased chance of becoming type 3 as 1.2 times (p = 0.001) in RCA, 1.2 times (p=0.003) in LCA. Mean value of right and left carotid tortuosity were $240.9{\pm}69.0^{\circ}$and $154.4{\pm}55.0^{\circ}$, respectively. Conclusion : The BMI, age, sex and presence of HTN affects the geometry of carotid arteries, the site of origin and tortuosity of carotid artery specifically.

Biceps Femoris Tendon and Lateral Collateral Ligament: Analysis of Insertion Pattern Using MRI (대퇴이두건과 외측 측부인대: 자기공명영상을 이용한 부착형태 유형의 분석)

  • Shin, Yun Kyung;Ryu, Kyung Nam;Park, Ji Seon;Lee, Jung Eun;Jin, Wook;Park, So Young;Yoon, So Hee;Lee, Kyung Ryeol
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.3
    • /
    • pp.225-231
    • /
    • 2014
  • Purpose : The biceps femoris tendon (BFT) and lateral collateral ligament (LCL) in the knee were formerly known to form a conjoined tendon at the fibular attachment site. However, the BFT and LCL are attached into the fibular head in various patterns. We classified insertion patterns of the BFT and LCL using MR imaging, and analyzed whether the LCL attaches to the fibular head or not. Materials and Methods: A total of 494 consecutive knee MRIs of 470 patients taken between July 2012 and December 2012 were retrospectively reviewed. There were 224 males and 246 females, and patient age varied from 10 to 88 (mean, 48.6). The exclusion criteria were previous surgery and poor image quality. Using 3T fat-suppressed proton density-weighted axial images, the fibular insertion patterns of the BFT and LCL were classified into following types: type I (the LCL passes between the anterior arm and direct arm of the BFT's long head), type II (the LCL joins with anterior arm of the long head of the BFT), type III (the BFT and LCL join to form a conjoined tendon), type IV (the LCL passes laterally around the anterior margin of the BFT), and type V (the LCL passes posteriorly to the direct arm of the BFT's long head). Results: Among the 494 cases of the knee MRI, there were 433 (87.65%) type I cases, 21 (4.25%) type II cases, 2 (0.4%) type III cases, 16 (3.23%) type IV cases, and 22 (4.45%) type V cases. There were 26 cases (5.26%) in which the LCL and BFT were not attached into the fibular head. Conclusion: The fibular attachment pattern of the BFT and LCL shows diverse types in MR imaging. The LCL does not adhere to the head in some patients.

Correlation of the Speed of Enhancement of Hepatic Hemangiomas with Intravoxel Incoherent Motion MR Imaging (간혈관종의 조영증강속도와 복셀내비결집운동 MR영상과의 상관관계)

  • Yang, Dal Mo;Jahng, Geon-Ho;Kim, Hyun Cheol;Kim, Sang Won;Kim, Hyug-Gi
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.3
    • /
    • pp.208-218
    • /
    • 2014
  • Purpose : To evaluate the relationship between the speed of enhancement of hepatic hemangiomas on gadolinium-enhanced MRI and ADC values by using various parameters, including the D, f, $D^*$ and $ADC_{fit}$ on intravoxel incoherent motion (IVIM) MR Imaging. Materials and Methods: The institutional review board approved this retrospective study. A total of 47 hepatic hemangiomas from 39 patients were included (20 men and 19 women). The hemangiomas were classified into three types according to the enhancement speed of the hepatic hemangiomas on gadolinium-enhanced dynamic T1-weighted images: rapid (Type A), intermediate (Type B), and slow (Type C) enhancement. The D, f, $D^*$ and $ADC_{fit}$ values were calculated using IVIM MR imaging. The diffusion/perfusion parameters and ADC values were compared among the three types of hemangiomas. Results: Both the $ADC_{fit}$ and D values of type C were significantly lower than those of type A (P = 0.0022, P = 0.0085). However, for the f and $D^*$, there were no significant differences among the three types. On DWI with all b values (50, 200, 500 and $800sec/mm^2$), the ADC values of type C were significantly lower than those of the type A (P < 0.012). For b values with $800sec/mm^2$, the $ADC_{800}$ values of the type C hemangiomas were significantly lower than those of type B (P = 0.0021). We found a negative correlation between hepatic hemangioma enhancement type and $ADC_{50}$ (${\rho}=-0.357$, P = 0.014), $ADC_{200}$ (${\rho}=-0.537$, P = 0.0001), $ADC_{500}$ (${\rho}=-0.614$, P = 0.0001), and $ADC_{800}$ (${\rho}=-0.607$, P = 0.0001). Therefore, four ADC values of $ADC_{50}$, $ADC_{200}$, $ADC_{500}$, and $ADC_{800}$ were decreased with decreasing enhancement speed. Conclusion: Hepatic hemangiomas had variable ADCs according to the type of enhancement, and the reduced ADCs in slowly enhancing hemangiomas may be related to the reduced pure molecular diffusion (D).

First-pass Stress Perfusion MR Imaging Findings of Apical Hypertrophic Cardiomyopathy: with Relation to LV Wall Thickness and Late Gadolinium-enhancement (심첨형 비후성 심근병증에서의 스트레스 부하 관류 자기공명영상 소견: 좌심실 벽 비후 정도와 지연 조영 증강 간의 관련성)

  • Yoo, Jin Young;Chun, Eun Ju;Kim, Yeo-Koon;Choi, Sang Il;Choi, Dong-Ju
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.1
    • /
    • pp.7-16
    • /
    • 2014
  • Purpose : To evaluate the prevalence and pattern of perfusion defect (PD) on first-pass stress perfusion MR imaging in relation with the degree of left ventricular hypertrophy (LVH) and late gadolinium-enhancement (LGE) in patients with apical hypertrophic cardiomyopathy (APH). Materials and Methods: Cardiac MR imaging with first-pass stress perfusion, cine, and LGE sequence was performed in 26 patients with APH from January 2008 to December 2012. We analyzed a total of 416 segments for LV wall thickness on end-diastolic phase of cine images, and evaluated the number of hypertrophied segment and number of consecutive hypertrophied segment (NCH). We assessed the presence or absence of PD and LGE from all patients. If there was PD, we subdivided the pattern into sporadic (sporadic-PD) or ring (ring-PD). Using univariate logistic method, we obtained the independent predictor for presence of overall PD and ring-PD. Results: PD on stress perfusion MRI was observed in 20 patients (76.9%), 12 of them (60%) showed ring-PD. Maximal LV wall thickness and number of hypertrophied segment were independent predictors for overall PD (all, p < 0.05). NCH with more than 3 segments was an additional independent factor for ring-PD. However, LGE was not statistically related with PD in patients with APH. Conclusion: About three quarters of the patients with APH showed PD, most of them represented as ring-PD. LVH degree or distribution was related with pattern of PD, however, LGE was not related with PD. Therefore, the clinical significance of PD in the patients with APH seems to be different from those with non-APH, and further comparison study between the two groups should be carried out.