• Title/Summary/Keyword: Korean image

Search Result 29,473, Processing Time 0.056 seconds

Image Quality Evaluation of CsI:Tl and Gd2O2S Detectors in the Indirect-Conversion DR System (간접변환방식 DR장비에서 CsI:Tl과 Gd2O2S의 검출기 화질 평가)

  • Kong, Changgi;Choi, Namgil;Jung, Myoyoung;Song, Jongnam;Kim, Wook;Han, Jaebok
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.27-35
    • /
    • 2017
  • The purpose of this study was to investigate the features of CsI:Tl and $Gd_2O_2S$ detectors with an indirect conversion method using phantom in the DR (digital radiography) system by obtaining images of thick chest phantom, medium thickness thigh phantom, and thin hand phantom and by analyzing the SNR and CNR. As a result of measuring the SNR and CNR according to the thickness change of the subject, the SNR and CNR were higher in CsI:Tl detector than in $Gd_2O_2S$ detector when the medium thickness thigh phantom and thin hand phantom were scanned. However, when the thick chest phantom was used, for the SNR at 80~125 kVp and the CNR at 80~110 kVp in the $Gd_2O_2S$ detector, the values were higher than those of CsI:Tl detector. The SNR and CNR both increased as the tube voltage increased. The SNR and CNR of CsI:Tl detector in the medium thickness thigh phantom increased at 40~50 kVp and decreased as the tube voltage increased. The SNR and CNR of $Gd_2O_2S$ detector increased at 40~60 kVp and decreased as the tube voltage increased. The SNR and CNR of CsI:Tl detctor in the thin hand phantom decreased at the low tube voltage and increased as the tube voltage increased, but they decreased again at 100~110 kVp, while the SNR and CNR of $Gd_2O_2S$ detector were found to decrease as the tube voltage increased. The MTF of CsI:Tl detector was 6.02~90.90% higher than that of $Gd_2O_2S$ detector at 0.5~3 lp/mm. The DQE of CsI:Tl detector was 66.67~233.33% higher than that of $Gd_2O_2S$ detector. In conclusion, although the values of CsI:Tl detector were higher than those of $Gd_2O_2S$ detector in the comparison of MTF and DQE, the cheaper $Gd_2O_2S$ detector had higher SNR and CNR than the expensive CsI:Tl detector at a certain tube voltage range in the thick check phantom. At chest X-ray, if the $Gd_2O_2S$ detector is used rather than the CsI:Tl detector, chest images with excellent quality can be obtained, which will be useful for examination. Moreover, price/performance should be considered when determining the detector type from the viewpoint of the user.

Biodistribution of 3-[$^{131}I$]iodo-O-methyl-L-${\alpha}$-methyltyrosine in Tumor Bearing Rats: A Comparison Study with L-3-[$^{131}I$]iodo-${\alpha}$-methyltyrosine (종양 이식 백서에서 3-[$^{131}I$iodo-O-methyl-L-${\alpha}$-methyltyrosine의 체내 동태 연구: L-3-[$^{131}I$iodo-${\alpha}$-methyltyrosine와 비교)

  • Choi, Chang-Woon;Yang, Seung-Dae;Woo, Kwang-Sun;Chung, Wee-Sup;Lim, Soo-Jung;Suh, Yong-Sup;Chun, Kwon-Soo;Ahn, Soon-Hyuk;Lee, Jong-Doo;Hong, Sung-Woon;Lim, Sang-Moo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.3
    • /
    • pp.290-297
    • /
    • 1998
  • Purpose : The aim of this study was to evaluate the feasibility of 3-[$^{131}I$]iodo-O-methyl-L-${\alpha}$-methyltyrosine ([$^{131}I$]OMIMT) as an agent for tumor image. Materials and Methods : After synthesis of 4-O-methyl-L-${\alpha}$-methyltyrosine (OMAMT), OMAMT was labeled with [$^{131}I$] using Iodogen method. In vitro cellular uptake study was performed using 9 L gliosarcoma cells at various time points upto 4 hr. The biodistribution (five rats implanted with the 9 L gliosar-coma cells per group) was evaluated at 30 min, 2 hr, 24 hr after iv injection of 3.7 MBq [$^{131}I$]OMIMT or L-3-[$^{131}I$]iodo-${\alpha}$-methyltyrosine [$^{131}I$]IMT). Gamma camera images were obtained at 30 min, 2 hr and 24 hr. Results: [$^{131}I$]OMIMT uptake was 3.3 times and 2.5 times higher than [$^{131}I$]IMT uptake at 30 min and 60 min, respectively and same after 2 hr in in vitro study using 9L gliosarcoma cells. Maximum accumulation in tumor occurred at 30 min for both [$^{131}I$]OMIMT and [$^{131}I$]IMT in tumor bearing rats. The tumor uptake of [$^{131}I$]OMIMT was significantly higher than that of [$^{131}I$]IMT at early time point studied ($3.74{\pm}0.48$ vs $0.38{\pm}0.17%$ ID/g at 30 min and $2.40{\pm}0.17$ vs $0.24{\pm}0.03%$ ID/g at 2 hr, respectively, p<0.01). However, the tumor uptake of both radiolabels were not significantly different at 24 hr ($0.04{\pm}0.01$ vs $0.05{\pm}0.01%$ ID/g). Tumor was visualized as early as at 30 min in gamma camera images. Conclusion: These data suggested that [$^{131}I$]OMIMT might be a useful tumor imaging agent and has more advantage for the tumor imaging compared to [$^{131}I$]IMT

  • PDF

A Refined Method for Quantification of Myocardial Blood Flow using N-13 Ammonia and Dynamic PET (N-13 암모니아와 양전자방출단층촬영 동적영상을 이용하여 심근혈류량을 정량화하는 새로운 방법 개발에 관한 연구)

  • Kim, Joon-Young;Lee, Kyung-Han;Kim, Sang-Eun;Choe, Yearn-Seong;Ju, Hee-Kyung;Kim, Yong-Jin;Kim, Byung-Tae;Choi, Yong
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.1
    • /
    • pp.73-82
    • /
    • 1997
  • Regional myocardial blood flow (rMBF) can be noninvasively quantified using N-13 ammonia and dynamic positron emission tomography (PET). The quantitative accuracy of the rMBF values, however, is affected by the distortion of myocardial PET images caused by finite PET image resolution and cardiac motion. Although different methods have been developed to correct the distortion typically classified as partial volume effect and spillover, the methods are too complex to employ in a routine clinical environment. We have developed a refined method incorporating a geometric model of the volume representation of a region-of-interest (ROI) into the two-compartment N-13 ammonia model. In the refined model, partial volume effect and spillover are conveniently corrected by an additional parameter in the mathematical model. To examine the accuracy of this approach, studies were performed in 9 coronary artery disease patients. Dynamic transaxial images (16 frames) were acquired with a GE $Advance^{TM}$ PET scanner simultaneous with intravenous injection of 20 mCi N-13 ammonia. rMBF was examined at rest and during pharmacologically (dipyridamole) induced coronary hyperemia. Three sectorial myocardium (septum, anterior wall and lateral wall) and blood pool time-activity curves were generated using dynamic images from manually drawn ROIs. The accuracy of rMBF values estimated by the refined method was examined by comparing to the values estimated using the conventional two-compartment model without partial volume effect correction rMBF values obtained by the refined method linearly correlated with rMBF values obtained by the conventional method (108 myocardial segments, correlation coefficient (r)=0.88). Additionally, underestimated rMBF values by the conventional method due to partial volume effect were corrected by theoretically predicted amount in the refined method (slope(m)=1.57). Spillover fraction estimated by the two methods agreed well (r=1.00, m=0.98). In conclusion, accurate rMBF values can be efficiently quantified by the refined method incorporating myocardium geometric information into the two-compartment model using N-13 ammonia and PET.

  • PDF

The Measurement of Sensitivity and Comparative Analysis of Simplified Quantitation Methods to Measure Dopamine Transporters Using [I-123]IPT Pharmacokinetic Computer Simulations ([I-123]IPT 약역학 컴퓨터시뮬레이션을 이용한 민감도 측정 및 간편화된 운반체 정량분석 방법들의 비교분석 연구)

  • Son, Hye-Kyung;Nha, Sang-Kyun;Lee, Hee-Kyung;Kim, Hee-Joung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.1
    • /
    • pp.19-29
    • /
    • 1997
  • Recently, [I-123]IPT SPECT has been used for early diagnosis of Parkinson's patients(PP) by imaging dopamine transporters. The dynamic time activity curves in basal ganglia(BG) and occipital cortex(OCC) without blood samples were obtained for 2 hours. These data were then used to measure dopamine transporters by operationally defined ratio methods of (BG-OCC)/OCC at 2 hrs, binding potential $R_v=k_3/k_4$ using graphic method or $R_A$= (ABBG-ABOCC)/ABOCC for 2 hrs, where ABBG represents accumulated binding activity in basal ganglia(${\int}^{120min}_0$ BG(t)dt) and ABOCC represents accumulated binding activity in occipital cortex(${\int}^{120min}_0$ OCC(t)dt). The purpose of this study was to examine the IPT pharmacokinetics and investigate the usefulness of simplified methods of (BG-OCC)/OCC, $R_A$, and $R_v$ which are often assumed that these values reflect the true values of $k_3/k_4$. The rate constants $K_1,\;k_2\;k_3$ and $k_4$ to be used for simulations were derived using [I-123]IPT SPECT and aterialized blood data with a standard three compartmental model. The sensitivities and time activity curves in BG and OCC were computed by changing $K_l$ and $k_3$(only BG) for every 5min over 2 hours. The values (BG-OCC)/OCC, $R_A$, and $R_v$ were then computed from the time activity curves and the linear regression analysis was used to measure the accuracies of these methods. The late constants $K_l,\;k_2\;k_3\;k_4$ at BG and OCC were $1.26{\pm}5.41%,\;0.044{\pm}19.58%,\;0.031{\pm}24.36%,\;0.008{\pm}22.78%$ and $1.36{\pm}4.76%,\;0.170{\pm}6.89%,\;0.007{\pm}23.89%,\;0.007{\pm}45.09%$, respectively. The Sensitivities for ((${\Delta}S/S$)/(${\Delta}k_3/k_3$)) and ((${\Delta}S/S$)/(${\Delta}K_l/K_l$)) at 30min and 120min were measured as (0.19, 0.50) and (0.61, 0,23), respectively. The correlation coefficients and slopes of ((BG-OCC)/OCC, $R_A$, and $R_v$) with $k_3/k_4$ were (0.98, 1.00, 0.99) and (1.76, 0.47, 1.25), respectively. These simulation results indicate that a late [I-123]IPT SPECT image may represent the distribution of the dopamine transporters. Good correlations were shown between (3G-OCC)/OCC, $R_A$ or $R_v$ and true $k_3/k_4$, although the slopes between them were not unity. Pharmacokinetic computer simulations may be a very useful technique in studying dopamine transporter systems.

  • PDF

Stress/Rest Tc-99m-MIBI SPECT in Comparison with Rest/Stress Rubidium-82 PET (휴식/부하 심근 Rubidium-82 양전자단층촬영과 부하/휴식 심근 Tc-99m-MIBI 단일광자단층촬영의 비교)

  • Lee, D.S.;Kang, K.W.;Lee, K.H.;Jeong, J.M.;Kwark, C.;Chung, J.K.;Lee, M.C.;Seo, J.D.;Koh, C.S.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.31-40
    • /
    • 1995
  • We compared stress/rest myocardial Tc-99m-MIBl tomographic image findings with rest/stress rubidium-82 tomographic images. In 23 patients with coronary artery disease (12 of them received bypass grafts before) and 6 normal subjects, rest rubidium PET study was performed : rubidium-82 and Tc-99m-MIBI were injected simultaneously to each patient after dipyridamole stress for rubidium PET and MIBI SPECT; and rest MIBI SPECT was performed 4 hours thereafter. We scored segmental decrease of rubidium or MIBI uptakes into 5 grades for 29 segments from 3 short-axis, vertical and horizontal slices. Scores were summed for each major arterial territory. When more score than two grade-2's or one grade-3 was considered as the cue for significant stenosis for major arterial territories, 67% of 46 stenosed arteries were found with MIBI studies and 78% of them by rubidium studies. Fourteen among 28 grafted arterial territories of 12 post-CABG patients were found normal with both rubidium and MIBI. Segmental scores were concordant between rubidium and MIBI in 72% of 709 stress segments and in 80% of 825 rest segments. Stress rubidium segmental scores were less than stress MIBI scores in 9%, so were rest rubidium scores. Stress rubidium scores were more than stress MIBI scores in 20% of segments, and rest rubidium segmental scores were more than rest MIBl scores in 11%. Rank correlations (Spearman's rho's more than 0.7(stress) and 0.5(rest), slopes (MIBI/rubidium) around 0.7(stress) and 0.9 (rest)) suggested deeper and wider defects in stress with rubidium. Slope over 1 (MIBI/rubidium) with LAD segemental scores at rest and 7 territories which had much larger score with MIBI revealed exaggeration of rest defects with rest MIBI in same-day stress/rest study. Difference scores (stress-rest for each territory) suggesting Ischemia were larger with rubidium (slope of MIBI/rubidium around 0.45). As has been implied by animal or separate-day-human studies, these segmental analyses with simultaneous examination in patients told that rubidium PET flow studies disclose ischemia more often than MIBI studies and that rest MIBI studies in same-day stress/rest-sequence gave a little larger rest defect than they would have shown.

  • PDF

The Evaluation of SUV Variations According to the Errors of Entering Parameters in the PET-CT Examinations (PET/CT 검사에서 매개변수 입력오류에 따른 표준섭취계수 평가)

  • Kim, Jia;Hong, Gun Chul;Lee, Hyeok;Choi, Seong Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.43-48
    • /
    • 2014
  • Purpose: In the PET/CT images, The SUV (standardized uptake value) enables the quantitative assessment according to the biological changes of organs as the index of distinction whether lesion is malignant or not. Therefore, It is too important to enter parameters correctly that affect to the SUV. The purpose of this study is to evaluate an allowable error range of SUV as measuring the difference of results according to input errors of Activity, Weight, uptake Time among the parameters. Materials and Methods: Three inserts, Hot, Teflon and Air, were situated in the 1994 NEMA Phantom. Phantom was filled with 27.3 MBq/mL of 18F-FDG. The ratio of hotspot area activity to background area activity was regulated as 4:1. After scanning, Image was re-reconstructed after incurring input errors in Activity, Weight, uptake Time parameters as ${\pm}5%$, 10%, 15%, 30%, 50% from original data. ROIs (region of interests) were set one in the each insert areas and four in the background areas. $SUV_{mean}$ and percentage differences were calculated and compared in each areas. Results: $SUV_{mean}$ of Hot. Teflon, Air and BKG (Background) areas of original images were 4.5, 0.02. 0.1 and 1.0. The min and max value of $SUV_{mean}$ according to change of Activity error were 3.0 and 9.0 in Hot, 0.01 and 0.04 in Teflon, 0.1 and 0.3 in Air, 0.6 and 2.0 in BKG areas. And percentage differences were equally from -33% to 100%. In case of Weight error showed $SUV_{mean}$ as 2.2 and 6.7 in Hot, 0.01 and 0.03 in Tefron, 0.09 and 0.28 in Air, 0.5 and 1.5 in BKG areas. And percentage differences were equally from -50% to 50% except Teflon area's percentage deference that was from -50% to 52%. In case of uptake Time error showed $SUV_{mean}$ as 3.8 and 5.3 in Hot, 0.01 and 0.02 in Teflon, 0.1 and 0.2 in Air, 0.8 and 1.2 in BKG areas. And percentage differences were equally from 17% to -14% in Hot and BKG areas. Teflon area's percentage difference was from -50% to 52% and Air area's one was from -12% to 20%. Conclusion: As shown in the results, It was applied within ${\pm}5%$ of Activity and Weight errors if the allowable error range was configured within 5%. So, The calibration of dose calibrator and weighing machine has to conduct within ${\pm}5%$ error range because they can affect to Activity and Weight rates. In case of Time error, it showed separate error ranges according to the type of inserts. It showed within 5% error when Hot and BKG areas error were within ${\pm}15%$. So we have to consider each time errors if we use more than two clocks included scanner's one during the examinations.

  • PDF

Research on The Utility of Acquisition of Oblique Views of Bilateral Orbit During the Dacryoscintigraphy (눈물길 조영검사 시 양측 안 와 사위 상 획득의 유용성에 대한 연구)

  • Park, Jwa-Woo;Lee, Bum-Hee;Park, Seung-Hwan;Park, Su-Young;Jung, Chan-Wook;Ryu, Hyung-Gi;Kim, Ho-Shin
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.76-81
    • /
    • 2014
  • Purpose: Diversity and the lachrymal duct deformities and the passage inside the nasal cavity except for anterior image such as epiphora happens during the test were able to express more precisely during the dacryoscintigraphy. Also, we thought about the necessity of a method to classify the passage into the naso-lachrymal duct from epiphora. Therefore, we are to find the validity of the method to obtain both oblique views except for anterior views. Materials and Methods: The targets of this research are 78 patients with epiphora due to the blockage at the lachrymal duct from January 2013 to August 2013. Average age was $56.96{\pm}13.36$. By using a micropipette, we dropped 1-2 drops of $^{99m}TcO4^-$ of 3.7 MBq (0.1 mCi) with $10{\mu}L$ of each drop into the inferior conjunctival fold, then we performed dynamic check for 20 minutes with 20 frames of each minute. In case of we checked the passage from both eyes to nasal cavity immediately after the dynamic check, we obtained oblique view immediately. If we didn't see the passage in either side of the orbit, we obtained oblique views of the orbit after checking the frontal film in 40 minutes. The instrument we used was Pin-hole Collimator with Gamma Camera(Siemens Orbiter, Hoffman Estates, IL, USA). Results: Among the 78 patients with dacryoscintigraphy, 35 patients were confirmed with passage into the nasal cavity from the anterior view. Among those 35 patients, 15 patients were confirmed with passage into the nasal cavity on both eyes, and it was able to observe better passage patterns through oblique view with a result of 8 on both eyes, 2 on left eye, and 1 on right eye. 20 patients had passage in left eye or right eye, among those patients 10 patients showed clear passage compared to the anterior view. 13 patients had possible passage, and 30 patients had no proof of motion of the tracer. To sum up, 21 patients (60%) among 35 patients showed clear pattern of passage with additional oblique views compared to anterior view. People responded obtaining oblique views though 5 points scale about the utility of passage identification helps make diagnoses the passage, passage delayed, and blockage of naso-lachrymal duct by showing the well-seen portions from anterior view. Also, when classifying passage to naso-lachrymal duct and flow to the skin, oblique views has higher chance of classification in case of epiphora (anterior:$4.14{\pm}0.3$, oblique:$4.55{\pm}0.4$). Conclusion: It is considered that if you obtain oblique views of the bilateral orbits in addition to anterior view during the dacryoscintigraphy, the ability of diagnose for reading will become higher because you will be able to see the areas that you could not observe from the anterior view so that you can see if it emitted after the naso-lachrymal duct and the flow of epiphora on the skin.

  • PDF

The Correction Factor of Sensitivity in Gamma Camera - Based on Whole Body Bone Scan Image - (감마카메라의 Sensitivity 보정 Factor에 관한 연구 - 전신 뼈 영상을 중심으로 -)

  • Jung, Eun-Mi;Jung, Woo-Young;Ryu, Jae-Kwang;Kim, Dong-Seok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.208-213
    • /
    • 2008
  • Purpose: Generally a whole body bone scan has been known as one of the most frequently executed exams in the nuclear medicine fields. Asan medical center, usually use various gamma camera systems - manufactured by PHILIPS (PRECEDENCE, BRIGHTVIEW), SIEMENS (ECAM, ECAM signature, ECAM plus, SYMBIA T2), GE (INFINIA) - to execute whole body scan. But, as we know, each camera's sensitivity is not same so it is hard to consistent diagnosis of patients. So our purpose is when we execute whole body bone scans, we exclude uncontrollable factors and try to correct controllable factors such as inherent sensitivity of gamma camera. In this study, we're going to measure each gamma camera's sensitivity and study about reasonable correction factors of whole body bone scan to follow up patient's condition using different gamma cameras. Materials and Methods: We used the $^{99m}Tc$ flood phantom, it recommend by IAEA recommendation based on general counts rate of a whole body scan and measured counts rates by the use of various gamma cameras - PRECEDENCE, BRIGHTVIEW, ECAM, ECAM signature, ECAM plus, IFINIA - in Asan medical center nuclear medicine department. For measuring sensitivity, all gamma camera equipped LEHR collimator (Low Energy High Resolution multi parallel Collimator) and the $^{99m}Tc$ gamma spectrum was adjusted around 15% window level, the photo peak was set to 140-kev and acquirded for 60 sec and 120 sec in all gamma cameras. In order to verify whether can apply calculated correction factors to whole body bone scan or not, we actually conducted the whole body bone scan to 27 patients and we compared it analyzed that results. Results: After experimenting using $^{99m}Tc$ flood phantom, sensitivity of ECAM plus was highest and other sensitivity order of all gamma camera is ECAM signature, SYMBIA T2, ECAM, BRIGHTVIEW, IFINIA, PRECEDENCE. And yield sensitivity correction factor show each gamma camera's relative sensitivity ratio by yielded based on ECAM's sensitivity. (ECAM plus 1.07, ECAM signature 1.05, SYMBIA T2 1.03, ECAM 1.00, BRIGHTVIEW 0.90, INFINIA 0.83, PRECEDENCE 0.72) When analyzing the correction factor yielded by $^{99m}Tc$ experiment and another correction factor yielded by whole body bone scan, it shows statistically insignificant value (p<0.05) in whole body bone scan diagnosis. Conclusion: In diagnosing the bone metastasis of patients undergoing cancer, whole body bone scan has been conducted as follow up tests due to its good points (high sensitivity, non invasive, easily conducted). But as a follow up study, it's hard to perform whole body bone scan continuously using same gamma camera. If we use same gamma camera to patients, we have to consider effectiveness of equipment's change by time elapsed. So we expect that applying sensitivity correction factor to patients who tested whole body bone scan regularly will add consistence in diagnosis of patients.

  • PDF

A Clinical Evaluation of Splanchnic Nerve Block (내장신경차단에 관한 임상적 연구)

  • Kim, Soo-Yeoun;Oh, Hung-Kun;Yoon, Duek-Mi;Shin, Yang-Sik;Lee, Youn-Woo;Kim, Jong-Rae
    • The Korean Journal of Pain
    • /
    • v.1 no.1
    • /
    • pp.34-46
    • /
    • 1988
  • Intractable pain from advanced carcinoma of the upper abdomen is difficult to manage. One method used to control pain associated with these malignancies is to block off the splanchnic nerve. In 1919 Kappis described a technique by which the splanchnic nerve of the upper abdomen could be anesthetized, using a percutaneous injection. This method has been used for the relief of upper abdominal pain due to hematoma and cancer of the pancreas, stomach, gall bladder, bile duct, and colon. During the Period from November 1968 to January 1986, this method was used in 208 cases of malignancy at Severance Hospital and clinically evaluated. Patients were retroactively grouped according to the stage of development of technique used. Twelve patients who received the treatment in the period from November 1968 to March 1977 were designate4i as group 1, 26 patients from April 1977 to April 1979 as group 2, and 170 from May 1979 to January 1986 as group 3. The results are as follows: 1) The number of patients receiving splanchnic nerve block has been increasing since 1977. 2) A total of 208 patients, including 133 males and 75 females, ranging in age from 18 to 84 and averaging 51. 3) The causes of pain were stomach cancer 90, pancreatic cancer 69, and miscellaneous cancer 49 cases respectively. 4) There were 57.7% who had surgery. and 3.7% of whom had chemotherapy before the splanchnic nerve block was done. 5) These blocks were carried out with the patient in the prone position as described by Dr. Moore. For group 2 and 3, C-arm image intensifier was used. In group 1, a 22 gauze loom long needle was inserted at the lower border of the 12th rib on each aide about 7\;cm from the midline. The average distance from the midline was $6.60{\pm}0.61\;cm$ on the left side and $6.60{\pm}0.83\;cm$ on the right side in group 2, and $5.46{\pm}0.76\;cm$ on the left side and $5.49{\pm}0.69\;cm$ on the right side in group 3. The average depth to which the needle was inserted was $8.60{\pm}0.52\;cm$ on the left side and $8.74{\pm}0.60\;cm$ on the right side in group 2, and $8.96{\pm}0.63\;cm$ on the left side and $9.18{\pm}0.57\;cm$ on the right side in group 3. 6) The points of the inserted needles were positioned in the upper quarter anteriorly, 51.8% on the left side and 54.4% n the right side of the L1 vertebra by lateral roentgenogram in group 3. The inserted needle points were located in the upper and anterolateral part, of the L1 vertebra 68.5% on the left side and 60.6won the right side, on the anteroposterior rentgenogram in group 3. The needle tip was not advanced beyond the anterior margin of the vertebral body. 7) In some case of group 3, contrast media was injected before the block was done. It shows, the spread upward along the anterior mal gin of the vertebral body. 8) The concentration and the average amount of drug used in each group was as follows: In group 1, $39.17{\pm}6.69\;ml$ of 0.5% -l% lidocaine or 0.25% bupivacaine were injected for the test block and one to three days after the test block $40.00{\pm}4.26\;ml$ of 50% alcohol was injected for the semipermanent block. In group 2, $13.75{\pm}4.88\;ml$ of 1% lidocaine were used as the test block and followed by $46.17{\pm}4.37\;ml$ of 50% alcohol was injected as the semipermanent block. In group 3, $15.63{\pm}1.19\;ml$ of 1% lidocaine for test block followed by $15.62{\pm}1.20\;ml$ of pure alcohol and $16.05{\pm}2.58\;ml$ of 50% alcohol for semipermanent block were injected. 9) The result of the test block was satisfactory in all cases. However the semipermanent block was 83.3 percent of the patients in group 1 who received relief from pain for at least 2 weeks after the block, 73.1% in group 2, and 91.8% in group 3. In these unsuccessful cases, 2 cases in group 1 were controlled by narcotics but 7 cases in group 2 and 14 cases in group 3 received the same splanchnic nerve block 1 or 2 times again within 2 weeks. But, in some cases it was 3 to i months before the 2nd block and in 1 cases even 7 years. 10) The most common complications of splanchnic nerve block were hypotensino(25.5%) occasional flushing of the face, nausea, vomiting, and chest discomfort. 11) For the patients in group 3, the supplemental block most commonly used was a continuous epidural block; it was used as a diagnostic block and to afford relief from pain before the splanchnic nerve block was done. 12) The interval between the receiving of the alcohol block and discharge was from 5 to 8 days in 61 cases(31.1%) and from 1 to 2 days in 48 cases(24.5%). From the above results, it can be concluded that the splanchnic nerve block done in the prone position with pure and 50% alcohol immediately after an effective test block with 1% lidocaine under C-arm fluoroscopic control is satisfactory and reliable. How to minimize the repeat block is still a problem to be solved.

  • PDF

A Comparative Survey on Misconception and Desire for Physique of College Women in Taegu and Fukuoka (한.일 여대생의 자기 체형 인식 및 체형 불안도에 관한 비교 연구)

  • Hong, Jin-Pyo;Choi, Bong-Soon
    • Journal of the Korean Society of Food Culture
    • /
    • v.15 no.5
    • /
    • pp.435-442
    • /
    • 2000
  • This study was carried out to investigate misconception for physique and desire for physique of college women in Taegu(412 subjects) and Fukuoka(423 subjects). The data was collected by questionnaire interview and anthropometric measurement. The results were as follows : The mean age, height, weight, and BMI of Taegu subjects were $19.9{\pm}1.2$ years old, $159.6{\pm}4.9cm,\;51.2{\pm}6.0kg\;and\;20.1{\pm}2.2$, respectively. The mean age, height , weight, and BMI of Fukuoka subjects were $18.3{\pm}0.6$ year old, $157.5{\pm}5.0cm,\;53.3{\pm}6.9kg\;and\;21.5{\pm}2.5$, respectively. The average ideal height desired by subjects in Taegu was higher than their real mean height by 5.1cm ; while the average ideal weight desired by subjects was lower than real mean weight by 2.6kg. The average ideal height desired by subjects in Fukuoka was higher than their real mean height by 3.2cm ; while the average ideal weight desired by subjects was lower than real mean weight by 5.4kg. The percentage of Taegu subjects who desired to be slender, be fatty and maintain weight were 70.1%, 7.3%, and 22.6% respectively. The percentage of Fukuoka subjects who desired to be slender, be fatty and maintain weight were 85.3%,2.6% and 12.1% respectively. The rate of misconception for the actual physique was 56.5% in Taegu subjects, and 57.2% In fukuoka subjects. The over estimation rate was higher in subjects desired for slenderness than in others. The adolescent females having a fatty body image in self-consciousness indicated that they felt high social physique anxiousness. Finally, the rate of misconception and the degree of social physique anxiousness were higher in those who had a desire for slenderness.

  • PDF