• Title/Summary/Keyword: Korean environmental standard method

Search Result 1,298, Processing Time 0.036 seconds

Comparison of Phytoplankton Chlorophyll-$\alpha$ Extracted with Different Solvents

  • Lee, Yun-Kyoung;Shin, Myoung-Sun;Jung, Yu-Kyong;Jang, Chang-Won;Kim, Bom-Chul
    • Korean Journal of Ecology and Environment
    • /
    • v.41 no.4
    • /
    • pp.485-489
    • /
    • 2008
  • Algal chlorophyll-$\alpha$ is commonly determined by spectro-photometric method using 90% acetone as solvents. However, acetone has low extraction efficiency without grinding filters, and DMF (dimethyl formamide) was tested for the compatibility with acetone. Chlorophyll-$\alpha$ concentration was determined for samples from 5 reservoirs of different trophic states and phytoplankton composition, using acetone extraction with grinding and DMF without grinding. Chlorophyll-$\alpha$ measured by DMF and Acetone did not show a significant difference when using trichromatic method of UNESCO and Lorenzen, and therefore, DMF can substitute acetone. But when acidification method was applied, they showed significant difference of 8%. It can be concluded that DMF can extract chlorophylls more effectively without grinding and it can be a better alternative for the standard extraction solvent.

Formaldehyde and TVOC Emission of Bio-Composites with Attached Fancy Veneer

  • Lee, Byoung-Ho;Kim, Hee-Soo;Kim, Ki-Wook;Lee, Se-Na;Kim, Hyun-Joong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.2
    • /
    • pp.46-55
    • /
    • 2008
  • This study assesses the formaldehyde and TVOC emissions from bio-composites with attached fancy veneer manufactured using wood flour and polypropylene (PP) measured using the Field and Laboratory Emission Cell (FLEC) method and 20 L small chamber method. To determine and compare the effects of the adhesive, samples were prepared with different manufacturing methods. In the FLEC result, the formaldehyde emission level of the bio-composites with attached veneer by hot-press was the lowest than pure bio-composite and bio-composite attached veneer using adhesive. The TVOC emission levels are similar to the formaldehyde emission. The TVOC emission level is very low in all of the samples except fancy veneer that is attached with bio-composites using adhesive. The TVOC emission varies depending on how attaching fancy veneer. The results of the 20 L small chamber method were very similar to those obtained with the FLEC, but the correlation was not perfect. However, the FLEC method requires a shorter time than the 20 L small chamber method to measure the formaldehyde and TVOC emissions. The internal bonding strength exceeded the minimum value of $0.4N/mm^2$ specified by the KS standard. All of the bio-composites with attached veneer satisfied the KS standard.

The controversial points for the assessment of soil contamination related to the change of pH of extraction solution in using partial extraction in standard method in Korea (국내 토양오염 공정시험방법의 용출법 사용시 용출액의 pH의 변화가 토양 오염 평가에 미치는 문제점)

  • 오창환;유연희;이평구;이영엽
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.11a
    • /
    • pp.294-297
    • /
    • 2000
  • Heavy metals are extracted from Chonju stream sediment, roadside soils and sediments along Honam expressway, soils and tailings from mining area using partial ectraction in Standard Method, partial ectraction method with maintaining 0.1N of extraction solution and acid digestion. In samples having buffer capacity against acid, 0.1N of extraction solution can not be maintained and pH of extraction solution increases up to 8.0 when partial extraction in Standard Method is used. The averages and ranges of (heavy metals extracted using partial extraction in standard method, HPE)/(heavy metals extracted using partial extraction method with maintaining 0.1N of extraction solution, HPEM) values are 0.506 and 0.145~1.126 in Cd, 0.534~ and 0.078~0.928 in Zn, 0.461 and 0.041~1.715 in Mn, 0.359 and 0.011~0.874 in Cu, 0.195 and 0.018~1.785 in Cr, 0.710 and 0.003~3.075 in Pb, and 0.088 and 1.73$\times$10$^{-5}$ ~0.303 in Fe. These data indicate that the difference between HPE and HPEM is big in the order of Fe, Cr, Cu, Mn, Cd, Zn and Pb. It is quite possible that the partial extraction method in Standard Method of soil in Korea is not adequate for an assessment of contamination in area where buffer capacity of soil will be decreased or lost after a long term exposure of soils to environmental damage.

  • PDF

Characteristics of Regulated Heavy Metals Content in Wastes Emitted from Industrial Processes (산업공정폐기물 중 규제대상 중금속류의 함량 특성)

  • Jeon, Tae-Wan;Lee, Dong-Jin;Yoon, Jung-In;Oh, Gil-Jong;Hwang, Dong-Gun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.6
    • /
    • pp.449-453
    • /
    • 2009
  • This study focused on the content characteristics of regulated hazardous substances in specific wastes. Regulated heavy metal such as Cu, Pb, Cd analyzed the 108 waste samples that it choice from the representative facilities. Analytical method used content test method, suggested on the basis of analytical method of developing country, and the results as compared with limited standard in Austria Petroleum, primary metalworking and electronic industry had high content of Cu more than 100 mg/kg of Austria limited standard. Pb detected high level concentration the sample that dust producted at Primary metalworking industry. In case of total Cr was show that high content at KSIC 18, 19, 23 etc but result analyzed Cr(VI), it was shown that high level at dust producted from sewing clothes and fur industry.

Developing Korean Standard for Nanomaterial Exposure Assessment

  • Lee, Ji-Hyun;Lee, Jun-Yeob;Yu, Il-Je
    • Toxicological Research
    • /
    • v.27 no.2
    • /
    • pp.53-60
    • /
    • 2011
  • Nanotechnology is now applied to many industries, resulting in wide range of nanomaterial-containing products, such as electronic components, cosmetic, medicines, vehicles, and home appliances. Nanoparticles can be released throughout the life cycle of nanoproducts, including the manufacture, consumer use, and disposal, thereby involving workers, consumers, and the environment in potential exposure. However, there is no current consensus on the best sampling method for characterizing manufactured-nanoparticle exposure. Therefore, this report aims to provide a standard method for assessing nanoparticle exposure, including the identification of nanoparticle emission, the assessment of worker exposure, and the evaluation of exposure mitigation actions in nanomaterial-handling workplaces or research institutes.

The Determination of Dissolved Total Fe by Flow Injection Analysis in Environmental Samples

  • Kim, Do Hoon;Takeda, Kazuhiko;Sakugawa, Hiroshi;Lee, Jin Sik
    • Analytical Science and Technology
    • /
    • v.14 no.6
    • /
    • pp.510-515
    • /
    • 2001
  • There has been an increasing need for analytical methods of dissolved total iron (tFe) that are highly sensitive, rapid, inexpensive and simple for environmental samples. A sensitive flow injection analysis (FIA) method for determining the concentration of tFe in environmental samples was developed. The proposed method required 10 minutes and only $500{\mu}L$ of sample for and analysis. The standard deviation was 5.0% at $0.5{\mu}gL^{-1}$ (n=6), and the detection limit was $0.075{\mu}gL^{-1}$. The developed method was applied to environmental samples such as tap water, mineral water, rain, snow and cloud water. Since this FIA system was free form interferences of coexisting ions commonly found in samples, sub-${\mu}gL^{-1}$ level of tFe could be easily determined without further preconcentration and separation.

  • PDF

Development of the Approximate Cost Estimating Model Using Statistical Inference for PSC Box Girder Bridge Constructed by the Incremental Launching Method (통계적 기법을 활용한 ILM압출공법 교량 상부공사 개략공사비 산정모델 개발 연구)

  • Kim, Sang-Bum;Cho, Ji-Hoon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.2
    • /
    • pp.781-790
    • /
    • 2013
  • This research focuses on development of the conceptual cost estimation models for I.L.M box girder bridge. The current conceptual cost estimation for public construction projects is dependent on governmental average unit price references which has been regarded as inaccurate and unreliable by many experts. Therefore, there have been strong demands for developing a better way of conceptual cost estimating methods. This research has proposed three different conceptual cost estimating method for a P.S.C. girder bridge built with the I.L.M method. Model (I) attempts to seek the proper breakdown of standard works that are accountable for more than 95 percentage in total cost and calculates the amount of standard work's materials from the standard section and volume of I.L.M box girder bridge. Model (II) utilizes a correlation analysis (coefficient over 0.6 or more) between breakdown of standard works and input data that would be considered available information in preliminary design phase. Model(III) obtains conceptual estimating through multiple-regression analysis between the breakdown of standard works and all of input data related to them. In order to validate the clustering of coverage in the preliminary design phase, the variation of I.L.M cost coverage from multiple-regression analysis[model(III)] has been investigated which result in between -3.76% and 11.79%, comparing with AACE(Association for the Advancement of Cost Engineering) which informs its variation between -5% and +15% in the design phase. The model proposed from this research are envisioned to be improved to a great distinct if reliable cost date for P.S.C. girder bridges can be continually collected with reasonable accuracies.

Analysis of Volatile Fatty Acids in Air by Dynamic SPME (Dynamic SPME를 이용한 공기 중 지방산 분석)

  • Yu, Mee-Seon;Yang, Sung-Bong;Ha, Nam-Ki
    • Journal of Environmental Science International
    • /
    • v.19 no.12
    • /
    • pp.1447-1454
    • /
    • 2010
  • In this study, the detection limits of lower fatty acids in air were investigated by using Dynamic SPME(Solid Phase Micro-Extraction), i.e. improved Head Space - SPME method(HS-SPME). This Dynamic SPME, called SPDE(Solid Phase Dynamic Extraction), is the analytical method for volatile compounds in air with the extraction by using a stainless steel needle of which inner surface is coated with adsorption material and following the gas chromatographic analysis by inserting the needle into a injection port of GC and subsequently, desorption of the volatile compounds into a gas-chromatographic column. Extraction was carried out by passing the sample air through the needle with a suction pump which has been used for a detection tube. The result of measurement for the 6 lower fatty acids showed that the detection limits ranged from 0.10 ppm to 0.44 ppm and the linear correlation coefficients were over 0.99. Relative standard deviations obtained from 5 analytical repetition of a ca. 1.6 ppm standard mixture were in the range of 1.87%~2.47%. This method has been shown to be a adequate for the measuring C2~C5 fatty acids in air in the concentrations of over several hundreds ppb.

TCE Exposure Assessment of Cleaning Workers (세척공정의 트리클로로에틸렌 TWA 및 STEL 평가 사례)

  • Hyun Soo Kim
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.1
    • /
    • pp.3-5
    • /
    • 2023
  • Objective: This study introduces exposure concentrations of time-weighted average standard (TWA) evaluation and short-time exposure standard (STEL) evaluation for trichloroethylene in the cleaning process. Methods: Trichloroethylene measurement was conducted according to the KOSHA Guide (A-24-2019) method. It was carried out twice. Results: As a result of the first measurement, TWA concentration exceeded 4 times the exposure standard and STEL concentration exceeded 16 times, but the inaccuracy and breakthrough of the collection time could not be considered, so the second measurement was conducted. The second measurement result was lower than the first measurement result, but exceeded the exposure standards (TWA, STEL). Conclusions: We were able to confirm that the exposure level of workers in the cleaning process using trichloroethylene exceeded the exposure standard. And it is also considered necessary to grasp the approximate concentration using a detector tube in the preliminary survey.

Influence of Digestion Temperature on the Extraction of Soil Heavy Metal by Korean Ministry of Environment Standard Method (토양오염공정시험기준에 따른 토양 중금속 추출 시 분해 온도가 미치는 영향)

  • Shin, Gunhwan;Park, Hyunjung;Oh, Kiseok;Jung, Gain;Shin, Dongjun;Lee, Goontaek;Joo, Changkyu;Lee, Sangmo;Kim, Taeseung
    • Journal of Soil and Groundwater Environment
    • /
    • v.27 no.3
    • /
    • pp.11-21
    • /
    • 2022
  • The purpose of this study was to evaluate the influences of digestion temperature on the extraction of heavy metals from soil using the standard method established by Korean Ministry of Environment (KMES). A total of 7 heavy metals (As, Cd, Cr, Cu, Ni, Pb and Zn) in soil samples were extracted at varying digestion temperatures [(66 ± 2.0)℃, (73 ± 1.9)℃, (80 ± 1.3)℃, (85 ± 1.7)℃, (92 ± 2.0)℃, (98 ± 1.7)℃]. As, Cd, Cu, Pb and Zn concentrations remained relatively constant over the temperature range, but Ni and Cr concentrations greatly varied with the digestion temperature. The extent of variation in extraction efficiencies as compared to the concentration obtained at 66℃ was in following order; Ni (7.09% ~ 35.42%) > Cr (4.79% ~ 25.40%) > Zn (3.99% ~ 17.52%) > Cu (2.22% ~ 19.34%) > As (3.54% ~ 8.26%) > Cd (-5.08% ~ 1.08%) > Pb (-4.71% ~ -1.70%). The accuracy for certified reference materials at the digestion temperature of 80 and 85℃ was 98.7% ~ 105.8%. Therefore, digestion temperature of 80℃ ~ 85℃ is suggested to obtain reliable and reproducible data when the standard method by Korean Ministry of Environment is employed to analyze multiple heavy metal components in soil samples.