• Title/Summary/Keyword: Korean Teeth

Search Result 6,105, Processing Time 0.029 seconds

APPLICATION OF ACIDIC PRIMER FOR ORTHODONTIC ADHESIVE SYSTEM (Acidic primer를 이용한 교정용 브라켓 접착의 전단결합강도)

  • Kim, Jin-Hee;Jin, Hun-Hee;Oh, Jang-Kyun
    • The korean journal of orthodontics
    • /
    • v.31 no.1 s.84
    • /
    • pp.137-147
    • /
    • 2001
  • Acidic primer is the bonding agent which combines the conditioning and priming agent into the single solution and was originally developed for the dentin bonding system. It is less harmful to the tooth structure and more convenient to manipulate than the traditional etching procedure. The Purpose of this study is to evaluate the shear bond strength of various bonding materials when the enamel is treated with acidic primer for the bracket bonding procedure. Fifty recently extracted human premolars were randomly separated into five groups -Group I using Clearfil Liner Bond 2 adhesive system to the enamel treated with acidic primer, Group II using Transbond XT adhesive system to the enamel treated with acidic primer, Group III using panavia 21 adhesive system to the enamel treated with acidic primer, Group IV using Fuji-Ortho LC adhesive system to the enamel treated with acidic primer, Group V using Transbond XT adhesive system to the enamel treated with 37$\%$ phosphoric acid. The shear bond strength was measured with Instron universal testing machine after storing in $37^{\circ}C$ water bath for 48 hours. After debonding, the teeth and brackets were examined under scanning electron microscope (SEM) and assessed with the adhesive remnant index (ARI). The results were as follows : 1. There were no significant differences in shear bond strength between group III ($8.69{\pm}2.72MPa$), group IV (9.7 ± 3.16 MPa), and group V ($10.48{\pm}2.60MPa$) (p>0.05). 2. The shear bond strength of group III and group IV was significantly higher than that of group I ($1.09{\pm}0.53MPa$), and Group II ($2.70{\pm}1.46MPa$) (p<0.05). 3. The ARI of group IV ($2.1{\pm}1.1$) and group V ($2.9{\pm}0.3$) was significantly higher than that of group I ($0.2{\pm}0.4$), group II ($0.3{\pm}0.9$) and group III ($0.2{\pm}0.4$) (p<0.05). 4. There were no significant difference between the ARI of group IV and group V (p>0.05). This result suggests that the combination of acidic primer and some bonding adhesive can provide sufficient shear bond strength for clinical orthodontics.

  • PDF

THE EFFECTS OF MECHANICAL AND THERMAL FATIGUE ON THE SHEAR BOND STRENGTH OF ORTHODONTIC ADHESIVES (기계적 및 열적 피로가 교정용 접착제의 결합강도에 미치는 영향)

  • Shin, Wan-Cheal;Kim, Jong-sung;Kim, Jong-Ghee
    • The korean journal of orthodontics
    • /
    • v.26 no.2 s.55
    • /
    • pp.175-186
    • /
    • 1996
  • The purpose of this study was to examine the effects of mechanical and thermal fatigue on the shear bond strength(SBS) of stainless steel mesh brackets bonded to human premolar teeth with 3 no-mix adhesives. The stainless steel mesh bracket was Ormesh(Ormco, .022 slot) and three types of no-mix adhesives were Ortho-one(Bisco), $Monolok^2$(RMO), $System\;1^+$(Ormco). The $10^6$ loadcycles of $17.4{\times}10^2sin2{\pi}ftlg{\cdot}cm$ and the 1,000 thermocycles of 15 second dwell time in each bath of $5^{\circ}C\;and\;55^{\circ}C$ were acturated as mechanical and thermal fatigue stress, and SBS were measured after each fatigue test. The fracture sites were analyzed by stereoscope and scanning electron microscope. The results obtained were summarized as follows; 1. Before thermocycles, $Monolok^2$ showed the highest Knoop hardness number(KHN, $64.03kg/mm^2$) and $System\;1^+$ showed the lowest value($31.60kg/mm^2$). After thermocycling, $Monolok^2$ also showed the highest KHN($38.03kg/mm^2$) and $system\;1^+$ showed the minimum($20.87kg/mm^2$). The KHN of Ortho-one, $Monolok^2,\;System\;1^+$ significantly decreased after thermocycling (P<0.01). 2. In static shear bond test, three adhesives had no significant differences in the SBS(P>0.01). 3. After thermocycling test, $Monolok^2$ showed the maximum SBS($19.34{\pm}2.75MPa$) and Ortho-one showed the minimum SBS($13.66{\pm}2.23MPa$). The SBS of Ortho-one(P<0.01) and $System\;1^+$(P<0.05) significantly decreased after $10^3$ thermocycles. 4. The SBS of three adhesives after $10^6$ loadcycles were similar and were not significantly decreased compared with static group(P>0.01). 5. The failure sites were usually bracket/resin interface in all groups irrespective of experimental conditions.

  • PDF

Shear bond strength of ceramic and resin brackets used with visible light-cured adhesives (도재 및 레진 브라켓에 대한 광중합 접착제의 전단 접착 강도)

  • Hwang, Yu-Sun;Row, Joon;Hwaang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.26 no.2 s.55
    • /
    • pp.233-244
    • /
    • 1996
  • The purpose of this study was to compare the shear bond strength obtained from ceramic and plastic brackets bonded with various light-cured adhesives and to evaluate their debonded failure sites. Plastic brackets, Transcend 6000, Signature and Starflre TMB brackets were bonded with Orthobond, Light Bond and Transbond on one hundred forty extracted human premolar teeth as manufacturer's descriptions. After thermocycling the brackets were debonded with an Instron universal testing machine and the debonded bracket base surfaces were inspected under stereoscope to evaluate the failure sites. Also the shear bond strength and failure patterns with different curing time and with two different source of light were compared. The results were as follows. 1. There were no statistically significant differences among the mean shear bond strength of Orthobond, Light Bond and Transbond in a same bracket group except Plastic bracket group(p<0.05). 2. The mean shear bond strength of each adhesive with different bracket groups showed statistically significant differences. Stafire TMB showed the highest shear bond strenght among the brackets in this study, but there was no statistically singnificant difference with Transcend 6000 while there was statistically significant difference with Signature.(p<0.05) 3. The various bonding failure patterns were occurred among different bracket groups but most of failure sites were bracket base -adhesive interfaces. 4. There were no statistically significant differences in shear bond strength between the groups with curing time of 10 second and 20 second, and between the groups with two different sources of light as long as sufficient light intensity(above $400mWcm^2$) were provided(p<0.05). According to the result, it should be considered in clinical use of ceramic bracket with light-cured adhesives that the shear strengths of ceramic brackets were influenced by the retention from of bracket base as well as the composition of bracket and there was no difference in the shear bond strenght among various light-cured adhesives used in this study.

  • PDF

A study on the limit of orthodontic treatment (교정 치료의 한계에 관한 연구)

  • Kim, Sun-Ju;Park, So-Young;Woo, Hae-Hong;Park, Eun-Jie;Kim, Young-Ho;Lee, Shin-Jae;Moon, Seong-Cheol;Baek, Seung-Hak
    • The korean journal of orthodontics
    • /
    • v.34 no.2 s.103
    • /
    • pp.165-175
    • /
    • 2004
  • Information on the limits of treatment could allow for more rational treatment Planning and better results after treatment. From this point of view, this article has attempted to discuss the limits of orthodontic tooth movement. A relatively wider range of tooth movement is expected after Class III surgical-orthodontics than after conventional orthodontic treatment in general. The purposes of this Paper were: first, to evaluate the reliability of teeth position measuring gauge; and second, to elucidate the limits of orthodontic tooth movement. Dental casts of fifty-fine subjects were analyzed by using Set-up model checker (InVisitec Co., Korea) before and aster the Class III surgical-orthodontic treatment. The changes of maxillary and mandibular dental arch widths were also measured from the canines to the second molars. To test the inter-examiner reliability, randomly selected casts were measured by another examiner. Descriptive statistics and paired t tests were used to explain the tooth movement during treatment. The results showed a relatively good reliability of measuring instruments and a very diverse range of tooth movement. Collective changes by the orthodontic tooth movement evaluated in Class III surgical-orthodontics allowed for a suggestive interpretation of specific treatment patterns. Arch width changes during the inter-arch coordination were mainly the result of tipping in both buccal segments. Based on the results of this study, the possibility of a change in dentition as a result of orthodontic treatment should be understood in order to launch a well-organized plan of treatment.

Relationship between the Malocclusion and Caries Prevalence of Adolescents in Iksan (익산시 청소년의 부정교합과 치아우식 유병률 사이의 연관성)

  • Shin, Gayoung;Ra, Jiyoung;An, Soyoun;Song, Jihyun;Lee, Kwanghee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.41 no.3
    • /
    • pp.207-217
    • /
    • 2014
  • The purpose of the present study was to evaluate the relationship between the malocclusion and dental caries in adolescents with permanent dentition. The subjects of the study were 385 adolescents aged 12 to 15 years. Dental Aesthetic Index (DAI) and DMFT index were recorded as clinical indicators of malocclusion and dental caries. The mean Dental Aesthetic Index (DAI) score of the subjects was 12.42 and the mean DMFT index of the subjects was 2.89. Four students (1.04%) were included in the group of orthodontic treatment mandatory, which signifies the handicapping malocclusion. Moreover, the result of gender-specific analysis of the DAI components observed that the prevalence of midline diastema and mandibular overjet were significantly higher among boys (p < 0.05). In 7 components (missing teeth, incisal segment crowding, maxillary anterior irregularity, mandibular anterior irregularity, mandibular overjet, anterior openbite, antero-posterior molar relationship) among the 10 DAI components, abnormal groups showed significantly higher DMFT index than normal groups (p < 0.05). The subjects in the group of definite to handicapping malocclusion (DAI ${\geq}$ 26) showed significantly higher DMFT index than the subjects in the group of minor or no malocclusion (p < 0.01). In addition, the DAI score had significant positive linear correlation with the DMFT index (r = 0.584, p < 0.01). Consequently, the current findings suggested a positive relationship between the malocclusion and caries prevalence. And several specific types of malocclusion were supposed to be significantly correlated with dental caries.

Korean athlete's recognition of sports dentistry and condition of teeth wear (한국 운동선수의 스포츠 치의학에 대한 인지도 및 치아교모상태에 관한 연구)

  • Lee, Sung-Bok;Choi, Dae-Gyun;Han, Kwang-Heung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.18 no.4
    • /
    • pp.235-249
    • /
    • 2002
  • This study was accompolished to analyze and compare the number and area of the occlusal contact points in healthy volunteers and athletes with normal occlusion. Before the study, 89 athletes(sports career:8.6 years, average age 20) at Kyung Hee University were selected, and survey was accomplished for athlete's recognition about sports dentistry. For this study, 15 athletes(13 amles and 2 females with average age 20) and 21 healthy volunteers(14 mles and 7 females with average age 20.09) at Kyung Hee University were selected. The visual display acquired by scanning of occlusal record in maximal intercuspation was converted into 16 gray value image. Then, using computer program(J & Lee Occlusal Analyser), the pixel which was in definite range of the gray value was recognized, and the numbers of recognized pixel were calculated to area. The results were as follows : (1) On the survey about sports dentistry, 28% of 89 athletes didn't agree that human occlusion may be important, and 30% didn't have any idea of the influence of human occlusion during their sports activities. (2) The average numbers of total occlusal contact points were 31.05 in control group, and 34.67 in athlete group. The average area of total occlusal contacts was $100.25mm^2$ in control group, and $127.78mm^2$ in athlete group. (3) In control group, the average numbers of occlusal contact points were revealed in order as follows; the first molar(8.48), the second molar(8.24), the second premolar(4.71), the lateral incisor(2.90), the first premor(2.43), the central incisor(2.19), and the canine(2.1). The least average in canine(2.1) was similar to the average(2.19) in central incisor and (2.09) in lateral incisor. In athlete group, the average numbers of occlusal contact points were revealed in order as follows; the first molar(8.87), the second molar(8.47), the second premolar(5.60), the canine(3.80), the lateral incisor(3.33), the first premolar(2.67), and the central incisor(1.93). (4) In control group, the average areas of occlusal contact surface were revealed in order as follows; the first molar($39.47mm^3$), the second molar($37.54mm^3$), the second premolar($9.54mm^3$) the first premolar($6.18mm^3$), canine($3.49mm^3$), the central incisor($2.76mm^3$), and the lateral incisor($1.28mm^3$). In athlete group, the average areas of occlusal contact surface were revealed in order as follows; the first molar($44.11mm^3$), the second molar($40.69mm^3$), the second premolar($16.50mm^3$), the first premolar($9.39mm^3$), the canine($5.08mm^3$), the lateral incisor($3.7mm^3$), and the central incisor($2.25mm^3$). (5). With aging in both control and athlete group, there was a decreasing tendancy in average number of occlusal contact point, and was an increasing tendancy in average area of occlusal contact surface. In comparison at each age, both the numbers and area of occlusal contact were greater in athlete group than in control group. It was not significant in the numbers of occlusal contact points beween athlete and control group(p>0.1), but significant in the area of occlusal contact surface(p<0.05). (6) In comparision as to the kind of sports(Gymnastics:2, Rugby:3, Soccor:5, Ice hocky:5), the numbers of occlusal contact points were the most in ice hocky, and the area of occlusal contact surface was the greatest in gymnastics. With increasing a career in athlete group, there was a decreasing tendancy in average numbers of occlusal contact points, and was an increasing tendancy in average area of occlusal contact surface.

The Effect of Tin Ion-plating on the Bond Strength of Orthodontic Bracket (TiN Ion-Plating이 교정용 브라켓의 접착강도에 미치는 영향)

  • KIM, Seok-Yong;KWON, Oh-Won;KIM, Kyo-Han
    • The korean journal of orthodontics
    • /
    • v.27 no.1
    • /
    • pp.157-171
    • /
    • 1997
  • This study was conducted to see the effect of TiN ion-plating on the bond strength of orthodontic bracket. Three stainless-steel brackets with different base types were chosen; when TiN ion-plated brackets and non iorrplated brackets were bonded to the teeth, initial and long-term bond strength were measured, The observations oi bonding surface and failure sites through the scanning electron microscope were analysed and compared. The summary of this study was as follows; ${\cdot}$ When TiN ion-plating was not applied, the Micro-Loc type was the highest in bond strength atter 24 hours as $5.89{\pm}1.77$ MPa, followed by $4,27{\pm}1.12MPa$ for Foil Mesh type and $2.64{\pm}0.58MPa$ for Undercut type(P<0.05). ${\cdot}$ Under TiN ion-plating, the bond strength after 24 hours showed: Micro-Loc type $-6.26{\pm}1.51MPa$, Foil Mesh type $-7.45{\pm}2.01MPa$, Undercut type $-2.93{\pm}0.84MPa$. Unlike in the case of non ion-plating, Foil Mesh type showed a higher strength than Micro-Loc type, with Undercut type still showing the lowest bond strength(P<0.05). The bond strength, after 24 hours, increased in case of ion-plated in all 3 types, but a significant increase was shown only in Foil Mesh type(P<0.001). ${\cdot}$ Under a long-term immersion, regardless of ion or non ion-plating, bond strength in general increased over the initial bond strength(one day), with more stability. ${\cdot}$ Through scanning electron microscopic observation of bonding surface, it was found that, regardless of the bracket base type or the application of ion-plating, the resin was thoroughly spreaded into bracket base to form a solid bonding surface between the bracket and the tooth. This was also true in case of a long-term immersion. ${\cdot}$ The scanning electron microscopic observation of failure sites revealed diverse failure patterns.

  • PDF

A Radiologic Study of the Relationship of the Maxillary Sinus Floor and Apex of the Maxillary Molar (상악동 아래벽과 상악 대구치 치근사이 위치관계에 관한 방사선학적 연구)

  • Yoon Hae-Rym;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.1
    • /
    • pp.111-126
    • /
    • 1998
  • In this study, radiographic evaluation was made using panoramic radiography and cross-sectional tomography of SCANORA/sup (R)/ in male and female adults in their 20's on the relationship between the maxillary sinus floor and the apex of the maxillary molar, to test the accuracy and effectiveness of the cross-sectional tomography, and to use this information in the assessment of preop. and postop. root canal treatment, apical surgery, extraction and implantology. Forty-one adults with an average age of 24.4 years were studied using panoramic radiography and cross-sectional tomography. In panoramic view and cross-sectional view, the position of the apices of maxillary molars were classified as separated, contacted, or protruded type; the general shape of the maxillary sinus floor was evaluated horizontally and vertically from cross-sectional tomography. The accuracy of each radiography was tested using maxilla from 5 fresh cadavers from the Anatomy Lab at Yonsei University Dental College, and panoramic view and cross-sectional tomography were taken in the same condition as with the patients. The results were as follows: 1. Panoramic view and cross-sectional view were taken in the maxilla specimen, and the actual distance between the maxillary sinus floor and the tooth apices were measured in the specimen; the median values of the distance from the tooth apices to the maxillary sinus floor in the panoramic view, cross-sectional view and in the actual maxilla specimen were 2.83 mm, 4.51mm, and 4.l5mm, respectively. In the cross-sectional view, the measured distance was close to the actual distance but in the panoramic view, the measured distance was far from the actual distance. 2. When the results of the panoramic view and cross-sectional view were compared, 40.5% of the results agreed with each other in the two radiographic methods and buccal roots of the 2nd molar were the closest to the maxillary sinus floor in the cross-sectional tomography. 3. In cross-sectional view, when the vertical relationship of the maxillary sinus floor and maxillary roots was assessed, in 1st molars, type II (the sinus floor that extends down to the buccolingual furcation area) was predominant, while in 2nd molars, type I (the sinus floor located above the level connecting the buccal and lingual apices) was predominant. In the horizontal relationship, in 1st molars, type II (the lowest floor of the maxillary sinus located in between the buccal and lingual roots) was predominant; in 2nd molars, type I (the lowest floor of the maxillary sinus located on the buccal side of the buccal roots) and type II appeared in similar frequency. In conclusion, the SCANORA/sup (R)/ cross-sectional tomography was more effective than the frequently used panoramic view, in that the relationship of the maxillary molars and maxillary sinus floor can be evaluated more accurately and the buccolingual cross-sectional view can also be observed. And maxillary sinus floor that was close to maxillary 2nd molar had tendency to be located on buccal side than that close to 1st molar. Therefore, cross-sectional tomography is an effective and accurate method to evaluate the position of the teeth in relation to the sinus floor preoperative and can be easily used to diagnose localized periapical lesions. Also, the image quality obtained was quite satisfactory.

  • PDF

Classification of the Family Congridae(Anguilliformes) from Korea (한국산(韓國産) 붕장어과(科)(뱀장어목(目)) 어류(魚類)의 분류(分類))

  • Lee, Chung-Lyul;Park, Mi-Hye
    • Korean Journal of Ichthyology
    • /
    • v.6 no.2
    • /
    • pp.132-159
    • /
    • 1994
  • The taxonomic revision of the family Congridae was made based on the specimens collected from the south-western coasts of the Korea from June 1988 to Oct. 1993. The family Congridae was classified into 8 species belonging to 6 genera. based on the external and internal morphological characters : Anago anago, Ariosoma anagodies, Ariosoma shiroanago shiroanago, Conger myriaster, Conger japonicus, Gnathophis nystromi nystromi, Rhechias retrotincta and Uroconger lepturus. Among the species reported as the congrid eels from Korea until now, four species were transferred into different generic or specific name Conger flavirostris into Ariosoma anagoides ; Astroconger myriaster into Conger myriaster ; Congrina retrotincta into Rhechias retrotincta and Rhynchocymba nystromi into Gnathophis nystromi nystromi. A Korean congrid eel, Ariosoma shiroanago shiroanago, was reported for first time in Korea. Intergeneric characters of the family Congridae were the form of the lateralline scales, the state of the tip of tail, the segmented state of the dorsal and anal fin rays, the existance of the supraoccipital bone and of lateral ethmoid process of the skull, the origin of dorsal fin and the forms of upper labial flange. The interspecific classification was made according to the characters such as the numbers of sensory pores of head part and in front of vent, teeth rows and numbers of upper and lower jaw, the numbers of vertebrae, the body color, the shapes of the head part, the color of intestine, the size of eye, the structure of air bladder and the number of branchiostegal rays. A new key on the taxonomical characteristics to the genera and species of the family Congridae has been estabilished and their distribution in Korea is described.

  • PDF

MICROLEAKAGE AND WATER STABILITY OF RESIN CEMENTS

  • Choi Sun-Young;Lee Sun-Hyung;Yang Jae-Ho;Han Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.3
    • /
    • pp.369-378
    • /
    • 2003
  • Statement of Problem: Recently, resin cements have become more widely used and have been accepted as prominent luting cements. Current resin cements exhibit less microleakage than conventional luting cements. However, the constant contact with water and exposure to occlusal forces increase microleakage even in resin cements inevitably. Most bonding resins have been modified to contain a hydrophilic resin such as 2-hydroxyethylmethacrylate (HEMA) to overcome some of the problems associated with the hydrophobic nature of bonding resins. By virtue of these modifications, bonding resins absorb a significant amount of water, and there may also be significant stresses at bonding interfaces, which may adversely affect the longevity of restorations. Therefore the reinforcement of water stability of resin cement is indispensable in future study. Purpose: This study was conducted to examine the influence of water retention on microleakage of two resin cements over the period of 6 months. Materials and Methods: 32 extracted human teeth were used to test the microleakage of a single full veneer crown. Two resin cements with different components and adhesive properties - Panavia F (Kuraray Co., Osaka, Japan) and Super-Bond C&B (Sun Medical Co., Kyoto, Japan)- were investigated. The storage medium was the physiological saline solution changed every week for 1 month, 3 months, and 6 months. One group was tested after storage for 1 day. At the end of the each storage period, all specimens were exposed to thermocycling from $5^{\circ}C$ to $55^{\circ}C$ of 500 cycles and chewing simulation of 50,000 cycles, and then stained with 50% silver nitrate solution. The linear penetration of microleakage was measured using a stereoscopic microscope at ${\times}40$ magnification and a digital traveling micrometer with an accuracy of ${\pm}3{\mu}m$. Values were analyzed using two-way ANOVA test, Duncan's multiple range tests (DMRT). Results : Statistically significant difference of microleakage was shown in the 3-month group compared with the1-day or 1-month group in both systems (p<0.05) and there were statistically significant differences in microleakage between the 3-month group and the 6-month group in both systems (p<0.05). The two systems showed different tendency in the course of increased microleakage during 3 months. In Panavia F, microleakage increased slowly throughout the periods. In Super-Bond C&B, there was no significant increase of microleakage for 1 month, but there was statistically significant increase of microleakage for the next 2 months. For the mean microleakage for each period, in the 3-month group, microleakage of Super-Bond C&B was significantly greater than that of Panavia F. On the other hand, in the 6-month group, microleakage of Panavia F was significantly greater than that of Super-Bond C&B (p<0.05). Conclusion: Within the limitation of this study, water retention of two different bonding systems influence microleakage of resin cements. Further studies with the longer observation periods in viro are required in order to investigate water stability and the bonding durability of the resin cement. CLINICAL IMPLICATIONS Microleakage at the Cement-tooth interfaces did not necessarily result in the failure of the crowns. But it is considered to be a major factor influening the longerity of restorations. Further clinical approaches for decreasing the amount of microleakage are required.