• Title/Summary/Keyword: Korean Oncology

Search Result 6,345, Processing Time 0.045 seconds

Preliminary Study for Imaging of Therapy Region from Boron Neutron Capture Therapy (붕소 중성자 포획 치료에서 치료 영역 영상화를 위한 예비 연구)

  • Jung, Joo-Young;Yoon, Do-Kun;Han, Seong-Min;Jang, HongSeok;Suh, Tae Suk
    • Progress in Medical Physics
    • /
    • v.25 no.3
    • /
    • pp.151-156
    • /
    • 2014
  • The purpose of this study was to confirm the feasibility of imaging of therapy region from the boron neutron capture therapy (BNCT) using the measurement of the prompt gamma ray depending on the neutron flux. Through the Monte Carlo simulation, we performed the verification of physical phenomena from the BNCT; (1) the effects of neutron according to the existence of boron uptake region (BUR), (2) the internal and external measurement of prompt gamma ray dose, (3) the energy spectrum by the prompt gamma ray. All simulation results were deducted using the Monte Carlo n-particle extended (MCNPX, Ver.2.6.0, Los Alamos National Laboratory, Los Alamos, NM, USA) simulation tool. The virtual water phantom, thermal neutron source, and BURs were simulated using the MCNPX. The energy of the thermal neutron source was defined as below 1 eV with 2,000,000 n/sec flux. The prompt gamma ray was measured with the direction of beam path in the water phantom. The detector material was defined as the lutetium-yttrium oxyorthosilicate (Lu0,6Y1,4Si0,5:Ce; LYSO) scintillator with lead shielding for the collimation. The BUR's height was 5 cm with the 28 frames (bin: 0.18 cm) for the dose calculation. The neutron flux was decreased dramatically at the shallow region of BUR. In addition, the dose of prompt gamma ray was confirmed at the 9 cm depth from water surface, which is the start point of the BUR. In the energy spectrum, the prompt gamma ray peak of the 478 keV was appeared clearly with full width at half maximum (FWHM) of the 41 keV (energy resolution: 8.5%). In conclusion, the therapy region can be monitored by the gamma camera and single photon emission computed tomography (SPECT) using the measurement of the prompt gamma ray during the BNCT.

Dosimetric Comparison of Intensity Modulated Radiation, Proton Beam Therapy and Proton Arc Therapy for Para-aortic Lymph Node Tumor (대동맥림프절 종양에 대한 세기조절방사선치료, 양성자치료, 양성자회전치료의 선량 비교평가)

  • Kim, JungHoon
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.331-339
    • /
    • 2014
  • To test feasibility of proton arc therapy (PAT) in the treatment of para-aortic lymph node tumor and compare its dosimetric properties with advanced radiotherapy techniques such as intensity modulated radiation therapy (IMRT) and conventional 3D conformal proton beam therapy (PBT). The treatment plans for para-aortic lymph node tumor were planned for 9 patients treated at our institution using IMRT, PBT, and PAT. Feasibility test and dosimetric evaluation were based on comparisons of dose volume histograms (DVHs) which reveal mean dose, $D_{30%}$, $D_{60%}$, $D_{90%}$, $V_{30%}$, $V_{60%}$, $V_{90%}$, organ equivalent doses (OEDs), normal tissue complication probability (NTCP), homogeneity index (HI) and conformity index (CI). The average doses delivered by PAT to the liver, kidney, small bowel, duodenum, stomach were 7.6%, 3%, 17.3%, 26.7%, and 14.4%, of the prescription dose (PD), respectively, which is higher than the doses delivered by IMRT (0.4%, 7.2%, 14.2%, 15.9%, and 12.8%, respectively) and PBT (4.9%, 0.5%, 14.12%, 16.1% 9.9%, respectively). The average homogeneity index and conformity index of tumor using PAT were 12.1 and 1.21, respectively which were much better than IMRT (21.5 and 1.47, respectively) and comparable to PBT (13.1 and 1.23, respectively). The result shows that both NTCP and OED of PAT are generally lower than IMRT and PBT. This study demonstrates that PAT is better in target conformity and homogeneity than IMRT and PBT but worse than IMRT and PBT for most of dosimetric factor which indicate that PAT is not recommended for the treatment of para-aortic lymph node tumor.

An Analysis of BMD Changes With Preoperative and Postoperative Premenopausal Breast Cancer Patient (폐경 전 유방암 환자의 치료 전.후 골밀도 변화 분석)

  • Kim, Su-Jin;Son, Soon-Yong;Choi, Kwan-Woo;Lee, Joo-Ah;Min, Jung-Whan;Kim, Hyun-Soo;Ma, Sang-Chull;Lee, Jong-Seok;Yoo, Beong-Gyu
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.279-286
    • /
    • 2014
  • The purpose of this study is to provide basic data of comparing BMD(bone mineral density) value of preoperative breast cancer patient and postoperative breast cancer patient due to bone loss with radiation/chemical therapy. The participants consisted of 254 breast cancer patients with BMD after having surgery and treatment from March 2007 to September 2013. Except for 84 patients with menopause or hysterectomy and we have analysed 171 patients. The BMD value(lumbar spine and femur) of before and after treatment from PACS by dure-energy X-ray absorptiometry was analyzed. First, we found variation of entire BMD and BMD according to treatment type, and analyzed detailed correlation by using marital status, number of children, presence of feeding, age of menarche, breast cancer therapy types as variable. Data was analyzed by using SPSS for Windows Program(version 18.0). BMD was decreased 7.1% in lumbar spine, 3.1% in femur respectively(p<.01). Also there is relatively high decrement($0.067g/cm^2$) in group who had just chemotherapy in femur(p<.05). There is decrement depend on marital status, number of children, presence of feeding, age of menarche, breast cancer therapy types but there was no statistical significance. The results show that BMD was decreased after treatment in premenopausal breast cancer patient, patient who had relatively high decrement need to be included high-risk group. As a result, aggressive prevention policy would be necessary.

Influence of Prognostic Factors on Survival Rate of Medulloblastoma Patient with Chemotherapy (항암치료를 받은 수모세포종환아에서 예후인자들이 생존률에 미치는 영향)

  • Shin, Kyung Mi;Choi, Sung Yeon;Won, Sung Chul;Yang, Chang Hyun;Lyu, Chuhl Joo;Suh, Chang Ok;Choi, Joong Uhn;Kim, Byung Soo
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.2
    • /
    • pp.178-182
    • /
    • 2003
  • Purpose : Brain tumors are the second most common tumor in childhood, and medulloblastomas comprise 15-25% of brain tumors. The well known prognostic factors are age at diagnosis, stage of disease, and extent of surgical excision. In this study, we analysed the prognostic factors in patients who received chemotherapy after excision. Methods : We reviewed the medical records of 61 patients who received chemotherapy among the 94 patients who were diagnosed and treated between Jan 1985 and Sep 2001 in the Department of Pediatrics and Neurosurgery at Severance Hospital. Results : Among the total survival rate of patients who underwent chemotherapy, the 3-yr progression-free survival rate was $66.5{\pm}6.3%$ and the 15-yr progression-free survival rate was $60.3{\pm}6.7%$. The progression-free survival rate for patients with age at diagnosis over 3 yrs old and under 3 yrs old, was $64.5{\pm}7.7%$ and $48.2{\pm}12.9%$ respectively and there was no statistically significant difference. The survival rate of the high vs low risk group by staging was $72.7{\pm}10.5%$ and $54.6{\pm}8.3%$ respectively, and there was no significant difference. The survival rate of patients with total removal vs subtotal removal was $65.8{\pm}11.8%$ and $56.8{\pm}8.2%$ respectively, showing no statistical difference. Conclusion : The reason there is no difference in survival rate according to the traditional prognostic factors is that chemotherapy has improved not only the total survival rate but also the survival rate in patients with poor traditional prognostic factors. So, sufficient removal of tumor followed by proper chemotherapy and radiotherapy is an important factor which influences the survival rate of medulloblastoma patients.

Effective Dose Evaluation using Clinical PET/CT Acquisition Protocols (전신 PET/CT 영상 획득 프로토콜을 이용한 유효선량 평가)

  • Nam, So-Ra;Son, Hye-Kyung;Lee, Sang-Hoon;Lee, Chang-Lae;Cho, Hyo-Min;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.17 no.3
    • /
    • pp.173-178
    • /
    • 2006
  • The purpose of this study was to evaluate the radiation dose for clinical PET/CT protocols in clinical environments using Alderson phantom and TLDs. Radiation doses were evaluated for both Philips GEMINI 16 slice PET/CT system and GE DSTe 16 slice PET/CT system. Specific organ doses with $^{137}Cs$ transmission scan, high quality CT scan and topogram in philips GEMINI PET/CT system were measured. Specific organ doses with CT scan for attenuation map, CT scan for diagnosis and topogram in GE DSTe PET/CT system were also measured. The organs were selected based on ICRP60 recommendation. The TLDs used for measurements were selected for within an accuracy of ${\pm}5%$ and calibrated in 10 MV X-ray radiation field. The effective doses for $^{137}Cs$ transmission scan, high qualify scan, and topogram in Philips GEMINI PET/CT system were $0.14{\pm}0.950,\;29.49{\pm}1.508\;and\;0.72{\pm}0.032mSv$ respectively. The effective doses for CT scan to make attenuation map, CT scan to diagnose and topogram in GE DSTe PET/CT system were $20.06{\pm}1.003,\;24.83{\pm}0.805\;and\;0.27{\pm}0.008mSv$ respectively. We evaluated the total effective dose by adding effective dose for PET Image. The total PET/CT doses for Philips GEMINI PET/CT (Topogram+$^{137}Cs$ transmission scan+PET, Topogram+high qualify CT+PET) and GE DSTe PET/CT (Topogram +CT for attenuation map+ PET, Topogram+diagnostic CT+ PET) are $7.65{\pm}0.951,\;37.00{\pm}1.508,\;27.12{\pm}1.003\;and\;31.89{\pm}0.805mSv$ respectively. Further study may be needed to be peformed to find optimal PET/CT acquisition protocols for reducing the patient exposure with good image qualify.

  • PDF

Estimated Exposure Dose and Usage of Radiological Examination of the National Health Screening (국가건강검진의 방사선검사 이용량 및 피폭선량 추정)

  • Gil, Jong Won;Park, Jong Hyock;Park, Min Hui;Park, Chan Young;Kim, So Young;Shin, Dong Wook;Kim, Won Dong
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.3
    • /
    • pp.142-149
    • /
    • 2014
  • Korea conducts a national health screening program to improve and check-up on public health and in recent years, the screening usage has been increased. Given the increased screening usage for radiographic exams, this study predicts the frequency of using radiographic exams and the exposure dose. This study estimates the usage of radiographic exams by isolating radiographic exams from the 2011 analysis of the national health insurance corporation, and estimates the public exposure dose by applying each procedure's dose table from UNSCEAR 2008. As a result of the analysis, in the 2011 National Health Screening, the average exposure dose per person is assumed to be 0.57 mSv, and depending on the type of screening program from the radiographic exam, an examinee could be exposed to between 0.2 mSv and 11.081 mSv. The frequency of using radiographic exposure was found to be 16,005,914 and the exposure dose was 6,311.76 person-Sv. The most frequent exam is the Chest X-ray, which was performed 1,070,567 (69.17%), and the UGI has the highest exposure dose at 5,217.94 person-Sv (82.67%). The outcome is categorized based on gender and age, excluding those under 39 years old. In all age groups, the screening usage and exposure dose are higher in females than in males. In particular, females between 50 and 54 years old have the highest screening usage (1,674,787, 10.5%) and exposure dose (701.59 person-Sv, 11.1%). As UGI accounts for 82.76% of procedures, except when done for medical purposes, if the government supports a voluntary UGI exam (which includes the UGI exam in the National Screening Program) or abolishes it completely, as seen overseas, the cost-effectiveness and validity of the UGI exam, as well as the exposure dose from the National Screening Program will all decrease significantly.

Evaluating the Dosimetric Characteristics of Radiation Therapies according to Head Elevation Angle for Head and Neck Tumors (두 경부 종양 치료 시 거상각도에 따른 치료기법 별 선량특성 평가)

  • Cheon, Geum-Seong;Kang, Seong-Hee;Kim, Dong-Su;Kim, Tae-Ho;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.27 no.1
    • /
    • pp.14-24
    • /
    • 2016
  • Since the head and neck region is densely located with organs at risk (OAR), OAR-sparing is an important issue in the treatment of head and neck cancers. This study-in which different treatment plans were performed varying the head tilt angle on brain tumor patients-investigates the optimal head elevation angle for sparing normal organs (e.g. the hippocampus) and further compares the dosimetric characteristics of different types of radiation equipment. we performed 3D conformal radiation therapy (3D-CRT), intensity-modulated radiation therapy (IMRT), and tomotherapy on 10 patients with brain tumors in the frontal lobe while varying the head tilt angle of patients to analyze the dosimetric characteristics of different therapy methods. In each treatment plan, 95% of the tumor volume was irradiated with a dose of 40 Gy in 10 fractions. The step and shoot technique with nine beams was used for IMRT, and the same prescription dose was delivered to the tumor volume for the 3D-CRT and tomotherapy plans. The homogeneity index, conformity index, and normal tissue complication probability (NTCP) were calculated. At a head elevation angle of $30^{\circ}$, conformity of the isodose curve to the target increased on average by 53%, 8%, and 5.4%. In 3D-CRT, the maximum dose received by the brain stem decreased at $15^{\circ}$, $30^{\circ}$, and $40^{\circ}$, compared to that observed at $0^{\circ}$. The NTCP value of the hippocampus observed in each modality was the highest at a head and neck angle of $0^{\circ}$ and the lowest at $30^{\circ}$. This study demonstrates that the elevation of the patients' head tilt angle in radiation therapy improves the target region's homogeneity of dose distribution by increasing the tumor control rate and conformity of the isodose curve to the target. Moreover, the study shows that the elevation of the head tilt angle lowers the NTCP by separating the tumor volume from the normal tissues, which helps spare OARs and reduce the delivered dose to the hippocampus.

Study on the Small Fields Dosimetry for High Energy Photon-based Radiation Therapy (고에너지 광자선을 이용한 방사선 치료 시 소조사면에서의 흡수선량평가에 관한 연구)

  • Jeong, Hae-Sun;Han, Young-Yih;Kum, O-Yeon;Kim, Chan-Hyeong
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.290-297
    • /
    • 2009
  • In case of radiation treatment using small field high-energy photon beams, an accurate dosimetry is a challenging task because of dosimetrically unfavorable phenomena such as dramatic changes of the dose at the field boundaries, dis-equilibrium of the electrons, and non-uniformity between the detector and the phantom materials. In this study, the absorbed dose in the phantom was measured by using an ion chamber and a diode detector widely used in clinics. $GAFCHROMIC^{(R)}$ EBT films composed of water equivalent materials was also evaluated as a small field detector and compared with ionchamber and diode detectors. The output factors at 10 cm depth of a solid phantom located 100 cm from the 6 MV linear accelerator (Varian, 6 EX) source were measured for 6 field sizes ($5{\times}5\;cm^2$, $2{\times}2\;cm^2$, $1.5{\times}1.5\;cm^2$, $1{\times}1\;cm^2$, $0.7{\times}0.7\;cm^2$ and $0.5{\times}0.5\;cm^2$). As a result, from $5{\times}5\;cm^2$ to $1.5{\times}1.5\;cm^2$ field sizes, absorbed doses from three detectors were accurately identified within 1%. Wheres, the ion chamber underestimated dose compared to other detectors in the field sizes less than $1{\times}1\;cm^2$. In order to correct the observed underestimation, a convolution method was employed to eliminate the volume averaging effect of an ion chamber. Finally, in $1{\times}1\;cm^2$ field the absorbed dose with a diode detector was about 3% higher than that with the EBT film while the dose with the ion chamber after volume correction was 1% lower. For $0.5{\times}0.5\;cm^2$ field, the dose with the diode detector was 1% larger than that with the EBT film while dose with volume corrected ionization chamber was 7% lower. In conclusion, the possibility of $GAFCHROMIC^{(R)}$ EBT film as an small field dosimeter was tested and further investigation will be proceed using Monte Calro simulation.

  • PDF

A Qualitative Study of Physicians' Perspectives on Non-Cancer Hospice-Palliative Care in Korea: Focus on AIDS, COPD and Liver Cirrhosis (국내의 비암성 질환의 호스피스 완화의료 적용에 대한 전문가의 인식에 관한 질적 연구: 후천성 면역결핍 증후군, 만성 폐쇄성 폐질환, 간경화를 중심으로)

  • Shin, Jinyoung;Yoon, Seok-Joon;Kim, Sun-Hyun;Lee, Eon Sook;Koh, Su-Jin;Park, Jeanno
    • Journal of Hospice and Palliative Care
    • /
    • v.20 no.3
    • /
    • pp.177-187
    • /
    • 2017
  • Purpose: From August 2017, hospice-palliative care (HPC) will be provided to patients with acquired immunodeficiency syndrome (AIDS), chronic obstructive pulmonary disease (COPD), and liver cirrhosis in Korea. To contribute to building a non-cancer (NC) hospice-palliative care model, NC specialists were interviewed regarding the goals, details, and provision methods of the model. Methods: Four physicians specializing in HPC of cancer patients formulated a semi-structured interview with questions extracted from literature review of 85 articles on NC HPC. Eleven NC disease specialists were interviewed, and their answers were analyzed according to the qualitative content analysis process. Results: The interviewees said as follows: It is difficult to define end-stage NC patients. HPC for cancer patients and that for NC patients share similar goals and content. However, emphasis should be placed on alleviating other physical symptoms and emotional care rather than pain control. Timing of the care provision should be when patients are diagnosed as "end stage". Special issues should be considered for each NC disease (e.g., use of anti-retroviral drugs for AIDS patients, oxygen supply for COPD patients suffering from dyspnea, liver transplantation for patients with liver cirrhosis) and education should be provided to healthcare professionals. NC patients tend to negatively perceive HPC, and the government's financial assistance is insufficient. Conclusion: It is necessary to define end-stage NC patients through in-depth discussion to minimize issues that will likely accompany the expansion of care recipients. This requires cooperation between medical staff caring for NC patients and HPC givers for cancer patients.

Bilateral retinoblastoma: Long-term follow-up results from a single institution (단일기관의 장기추적 결과)

  • Choi, Sang Yul;Kim, Dong Hwan;Lee, Kang Min;Lee, Hyun Jae;Kim, Mi-Sook;Lee, Tai-Won;Choi, Sang Wook;Kim, Dong Ho;Park, Kyung Duk;Lee, Jun Ah
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.6
    • /
    • pp.674-679
    • /
    • 2009
  • Purpose : The authors aimed to analyze the long-term effects of treatments, especially external beam radiotherapy (EBRT), in bilateral retinoblastoma patients. Methods : This retrospective study analyzed the medical records of 22 bilateral retinoblastoma patients who were registered between October, 1987 and October, 1998 and followed-up for more than 10 years. They were treated by enucleation, EBRT, and systemic chemotherapy. Age at diagnosis, sex, delay prior to treatment, Reese-Ellsworth (RE) classification, and the local treatment modalities were analyzed in relation to recurrence-free survival (RFS) and complications. Results : Median age at diagnosis was 7.0 months (range 1.7-31.6 months). Leukocoria was the most common presenting feature. Two patients had a familial history. The RE classifications of the 44 eyes were group II in 4, III in 14, IV in 4, and V in 22. At the end of a median follow-up period of 141 months (range 55-218 months), 20 patients were alive. The 10-year ocular survival rate of the 44 eyes was $56.8{\pm}7.5%$. The 10-year RFS and ocular survival rate of the 29 eyes treated by combined EBRT and chemotherapy were 75.9% and 86.2%, respectively. Treatment delay (>3 months) was found to be related to higher risk of recurrence. Complications after EBRT were cataract, retinal detachment, phthisis bulbi, and facial asymmetry. No patient developed a second malignancy during the follow-up period. Conclusion : Early detection and prompt treatment can increase ocular survival rates. In addition, careful attention should be paid to possible long-term sequelae in these patients.