• 제목/요약/키워드: Korean Industrial Standards (KS)

Search Result 135, Processing Time 0.027 seconds

A Study on the Quality Control Plan for Waterproof Construction in Apartment Houses (공동주택 방수공사 품질관리 방안 마련에 관한 연구)

  • Kim, Kwang-Ki;Kim, Byoungil
    • Journal of the Korea Institute of Building Construction
    • /
    • v.24 no.1
    • /
    • pp.109-120
    • /
    • 2024
  • For successful waterproofing construction, it is very important to secure construction quality as well as material performance of waterproofing materials used in construction. Due to the long-term cost reduction policy following the economic downturn in the construction market, most construction companies are using general low-priced waterproof materials rather than high-quality waterproof materials without clear quality control standards. Without clear education on construction, construction is being carried out with meaning only on construction activities. In addition, the waterproofing method applied in combination is a situation where water leakage occurs due to waterproofing failure due to insufficient construction quality because the construction method is complicated. Therefore, it is necessary to review the quality control measures(design, materials, construction) for successful waterproofing work and improve problems that are derived so that stable waterproofing work can be done. In order to expect the leakage prevention effect of a building, first, it is required to select appropriate materials for each part of the building and environment in the design stage, and the selected materials must satisfy all items of the Korean Industrial Standard(KS). Second, to secure the quality of waterproofing construction, sincere construction by workers is required. In this paper, we tried to describe "review of waterproof design", "constructor education", "site inspection", and "criticism(correction/supplementation)" as quality control measures after material selection.

Critical Review on Carcinogenicity of Metalworking Fluids (절삭유(Metalworking Fluids)의 발암성에 대한 고찰)

  • 박동욱;윤충식;이송권
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.1
    • /
    • pp.50-62
    • /
    • 2003
  • Exposure to metalworking fluids (MWFs) has significantly been associated with cancer developed in multi-organs, respiratory diseases and skin diseases. Several carcinogens to humans or animals are contained in MWFs. They have been reported to be mineral oils, polynuclear aromatic hydrocarbons (PAHs), formaldehyde and N-nitrosodiethanolamine (NDELA). The great hazards of MWF have forced the advanced country including United States to regulate carcinogens contained in MWF. In 2001, American Conference of Governmental Industrial Hygienists (ACGIHs) regarded MWF mist as suspected carcinogen to human (A2) and added it to “Notice of Intended Change (NIC)” list of 2001. In spite of the fact that much MWF has widely been used in many industries using machines, Korea has no legal actions for management of MWF. What is worse, even toxicity such as Carcinogenicity has not been reported. KS (Korean Standards) lists 7 advices of MWF but it does net state the hazards to health. It is very hard to control or minimize worker's exposure to MWF containing many carcinogens. Prier to the introduction of MWF to workplace, it is the most effective measure to regulate carcinogens below a certain level. Regulation on the content of PAH seems to be necessary because less amount of PAH in mineral oils improves the quality of MWF. Also, addition of nitrosating groups to MWF should be prohibited to minimize worker's exposure to NDELA. Employers and manufacturers should indicate the Carcinogenicity of all carcinogens in MWFs in Material Safety Data Sheets (MSDS) in order fer workers to recognize Carcinogenicity. Legal actions have to be taken to protect workers from health hazards due to exposure to MWF by further investigation on MWF.

A Study on Compressive Strength of Built-up H Shaped Columns Fabricated with HSA800 High Performance Steels (건축구조용 고성능강(HSA800) 용접 H형단면 기둥의 압축강도에 관한 연구)

  • Kim, Tae Soo;Lee, Myung Jae;Oh, Young Suk;Lee, Kang Min;Kim, Do Hwan
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.6
    • /
    • pp.627-636
    • /
    • 2012
  • Recently, high performance(strength) steels have been utilized to structural materials in buildings and bridges with the demand for high-rise and long-span of main structures. This paper is a series of basic study for the design specification of structural members using high performance steel, material properties of high performance rolled steel building structures; material properties of HSA800 steel was compared with the requirements of Korean Standards(KS) for HSA800. Welded H-shape stub columns with variables of width-to-thickness ratios are planned in order to investigate the local buckling behaviors and check the current design limit of width-to-thickness ratio and uniaxial compressive tests are carried out. In addition, the buckling behaviors of stub columns obtained finite element analysis were compared with those of test results.

Comparison of the Lighting Environment in Study Rooms for Juveniles between the City and the Country

  • Kim, Hyun-Ji;Jeon, Gyeong-Seon;An, Ok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.7
    • /
    • pp.1-7
    • /
    • 2009
  • The research aims at providing data needed for planning the lighting of a study room by comparing the lighting environments of study rooms for urban and rural juveniles. The subject of the research was 300 students in middle schools in Daegu and Checngdo-gun, Gyeongsangbuk-do (Daegu 150 houses and Cheongdo 150 houses), and their study rooms were examined. The following is the result of the research. First, rural students stayed more time in their study room than urban students. The task that rural students (studying) and urban students (studying and using computer) all did in their study room was mainly visual work Second, although the sizes of rural study rooms were bigger than those of urban study rooms, urban study rooms had more light sources than rural study rooms. In the rate that of having a task lighting, the city(87.1[%]) was higher than the country (45.7[%]). However, the rate of using a task lighting was lot high in both the city and the country. Third, the result that compared the average values of illuminations on desk planes was that the average value of the city was 3.4 times higher than that of the country. Also, the average value of the country did not meet the standard illumination of Korean industrial standards (KS). In particular, it did not reach the lowest standard. The result is related with that only 52[%] of students who had a task lighting used it. Finally, the satisfaction of lighting environment in the city was generally higher than the country. Especially, although the country had a low illumination, the user showed a high satisfaction. It indicates that people living in the country need to understand about the needs of illumination.

A Study on the Sanitary Condition of Kitchens in Food Court/Cafeterias - An Observation on Seasonal Variations (휴게음식점 주방의 환경위생상태에 관한 조사연구 - 계절별 변화를 중심으로 -)

  • Kim, Jong-Gyu;Park, Jeong-Yeong;Kim, Joong-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.2
    • /
    • pp.118-127
    • /
    • 2012
  • Objectives: This study was undertaken to assess the sanitary conditions in the kitchens of food court/cafeterias and determine seasonal variations. Methods: We measured environmental factors (air temperature, relative humidity, illumination intensity, noise level), and dropping airborne microbes (bacteria and fungi) in the kitchens of eight food court/cafeterias in four seasons (January, April, July, and October). Air temperature and relative humidity were measured with in/out thermo-hygrometers at 1.2-1.5 m above floor level. Illuminance measurement was performed through the multiple point method of Korean Standards (KS). Noise level was measured by the standard methods for the examination of environmental pollution (noise and vibration) of Korea. The estimation of dropping airborne bacteria and fungi was performed through use of Koch's method. Results: The highest kitchen air temperature was in July, and the lowest in January. The average temperature surpassed $21^{\circ}C$ throughout the seasons, suggesting a higher temperature than required for the safe handling of food. Humidity in all the kitchens was measured in the range of 50-60%. Half of the kitchens showed illumination intensities below 300 Lux in April. It was found that the sound pressure level of noise in almost all of the kitchens was higher than 85 dB (A). The highest levels of dropping airborne bacteria and fungi were noted in July. The numbers of airborne bacteria were higher than those of fungi. The levels of dropping airborne bacteria and fungi were affected by air temperature, relative humidity, season, and place. Conclusions: This study indicates that the kitchen environments were unqualified to supply safe food. The hygiene level of the kitchens should be improved.

Study on Simulation Design of Light Emitting Diode Luminaires for 100 W Safety Street Lighting

  • Shin, Ik-Tae;Lee, Se-Il;Yang, Jong-Kyoung;Park, Dae-Hee;Lee, Dong-Jin
    • Transactions on Electrical and Electronic Materials
    • /
    • v.11 no.3
    • /
    • pp.138-144
    • /
    • 2010
  • Optical analysis is necessary to optimize light emitting diode (LED) safety street lighting. In this study, optical analysis was conducted for 100 W LED safety street lighting. Experimental research on such a single LED was the first undertaken. Simulation modeling based on the optical properties of the single LED has compared between average road illuminances and has them analyzed with Korean Industrial Standards for LED safety street lighting (KS C7658:2009). The simulation results demonstrated that the illumination performance (average road illuminance) was 75.3 lx at a height of 4 m and an area of $32\;m^2$, 45.25 lx at a height of 5 m and an area of $72\;m^2$, and 30.05 lx at a height of 6 m and an area of $128\;m^2$. 100 W safety street lighting (model CE180-ST-OS) designed by simulation was also compared between product and 100 W simulation modeling, and error rates averaged 5.6%. The 100 W LED safety street lighting base designed in simulation modeling was proven by comparison experiments. Through the simulations and the corresponding analysis, it was found that the tested 100 W LED safety street lamp had reasonable performance. The design method for LED safety street lamps has been summarized based on the optical analysis.

Fundamental Properties of Asphalt Concrete Mixture as Using TDF Fly Ash as Mineral Filler (아스팔트 콘크리트 채움재로 TDF Fly Ash 적용에 따른 아스팔트 혼합물 기초 물성 평가)

  • Choi, Min-Ju;Kim, Hyeokjung;Kim, Yongjoo;Lee, Jaejun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.2
    • /
    • pp.497-505
    • /
    • 2017
  • TDF (Tire derived fuel) Fly ash is an industrial by-product when scraped tire was used a fuel source at the power plant. TDF Fly ash has been classified as domestic waste at the workplace so far and has not been appropriately utilized. We conducted a fundamental physical property test of asphalt mixture to investigate the possibility of using TDF Fly ash as a mineral filler of asphalt mixture for exploring new usage strategies. TDF Fly ash meets KS F 3501 asphalt mixture mineral filler criteria. And the optimal asphalt binder amount was determined to be 4.5% by Marshall design. Mineral filler content was determined at 3% and analyzed by comparing using mineral filler as stone powder. The basic physical property test of the asphalt mixture was evaluated to the provision indicated in "Production and Construction Guidelines for Asphalt Mixture" published by the Ministry of Land, Infrastructure and Transport. In the test, Marshall stability test, dynamic immersion test, tensile strength ratio test, wheel tracking test were carried out. As a result of the experiment, Marshall stability and dynamic stability satisfied the standards, and confirmed the stability and Dynamic immersion and tensile strength ratio test that TDF Fly ash is more effective for scaling and moisture resistance than stone dust. Therefore, in this research, it is expected that multilateral utilization of TDF Fly ash, and a positive effect can be also expected.

The Quality of Crushed Sand by Dry Production Process and Its Influence on Properties of Concrete (건식공정으로 생산한 부순 모래의 품질 및 콘크리트 특성에 미치는 영향)

  • Park, Cho-Bum;Baek, Chul-Woo;Kim, Ho-Su;Ryu, Deuk-Hyun
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.3 s.93
    • /
    • pp.415-423
    • /
    • 2006
  • As the shortage of natural & good quality aggregate for concrete, it is needed development of alternative aggregate. At the present time, the crushed sand is widely used among the alternation aggregate, and the usage of crushed sand will be increased more and more. Generally, crushed sud is produced with wet process in domestic, but some manufacturing companies which are handicapped with local restrict are produced by dry process. In this study, analyzing the facilities of dry crushed sand, the quality properties of dry crushed sand was done by Korean Industrial Standards. Based on the quality results of dry crushed sand, the experiment of concrete with the dry crushed sand which is substitute for sea sand was done. As the results of basic qualities, the amount of 0.08 mm sieve passing ratio was over KS criteria, and the fineness modulus was higher than sea sand, and the other physical properties of dry crushed sand was similar to sea sand. The results of concrete experiment, according to the substitutive ratio of dry crushed sand is increased, the slump and air content of concrete was decreased by increase of fine particles of dry crushed sand, and the unit weight content, compressive & tensile strength of concrete were increased on the contrary. The physical properties of concrete used dry crushed sand were showed same tendency without relation to W/B. Consequently, if the fine particle contents of dry crushed sand was lower, it is judged that dry crushed sand is no problem to use for concrete aggregate and the amount of usage will be increased.

The Quality Properties of Self-Compacting Concrete Mixed with Tailing from the Sangdong Tungsten Mine (상동광산 광미를 혼합한 자기충전 콘크리트의 품질 특성)

  • Choi, Yun-Wang;Kim, Yong-Jic;Choi, Wook
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.6 s.96
    • /
    • pp.777-783
    • /
    • 2006
  • This study has focused on the possibility for recycling of tailings from the Sangdong tungsten mine as powder(TA) of self-compacting concrete(SCC). The experimental tests for slump-flow, time required to reach 500 mm of slump flow(sec), time required to flow through V-funnel(sec) and filling height of U-box test(mm) were carried out in accordance with the specified by the Japanese Society of Civil Engineering(JSCE). The results of this study, slump-flow of SCC was satisfied a prescribed range. And time required to reach 500 mm of slump flow(sec) and time required to flow through V-funnel(sec) decreased with increasing replacement of TA. But filling height of U-box test(mm), replacement of TA up to 30% were satisfied a prescribed range. The mechanical properties including compressive strength, splitting tensile strength and elastic modulus were checked with the requirements specified by Korean Industrial Standards(KS). The compressive strength of SCC decreased with increasing replacement of TA, splitting tensile strength and elastic modulus were similar to those of normal concrete. The fundamental durability was reviewed through the dry shrinkage rate and accelerated carbonation tests. As the result dry shrinkage rate and accelerated carbonation depth increased with increasing replacement of TA.

Suitability of classroom chairs from standpoint of body dimensions of school children in Korea (한국 아동의 신체치수에서 본 아동용 학교 의자의 적합성)

  • Cho, Am;Kim, Myung-Jin;Lee, Sang-Bong;Lee, Yoon-Dong;Oh, Byung-Wan
    • Journal of the Ergonomics Society of Korea
    • /
    • v.9 no.2
    • /
    • pp.55-63
    • /
    • 1990
  • School children sit long on chairs in their classrom. Their posture is closely related to their chairs. Study of this relationship is very imporant for the health and education of school children. This report presents the results of study condcuted to determine the present status of classroom chairs and solve any problems identifede. The study involved 125 teachers in Seoul and Pusan, 175 fourth graders in Seoul, and 109 fourth graders in Puasn. The body dimensions of the school children and the dimensions of their chairs and desks were measured, and their postures while they studied at their desk were photographed. The following problems were identified as a result of the investigation: (1) Chairs are allocated to pupils according to their stature. (2) The teachers are not satisfied with the chairs and the method by which the chairs are allocated to their pupils. (3) The pupils complain of low seat height, narrow seat, and hard backrest, among other conditions. (4) The pupils select a chair one size larger than that suggested by their body size. (5) The poor posture of the pupils is traced to the seat height and sasyaku$(sitting height {\times} 1/3-1)$ of their chairs, their habit, their way of holding pencils, and lack of instruction by their teachers. The following recommendations are made to solve these problems: (1) Adjust the seat height and desk height to accommodate the pupils. (2) Provide both teachers and pupils with adequate knowledge of chails. (3) Provided each pupil with one desk and make the desk adjustable to sit his or her body dimensions. (4) Allocate a chair and desk to each pupil for his or her exclusive use. (5) Reserch and develop conversion tables that help to find suitable chails for individual pupils. New values of sasyaku and desk height, not specified in Korean Industrial Standards(KS), are proposed.

  • PDF