• Title/Summary/Keyword: Korean Code

Search Result 11,497, Processing Time 0.054 seconds

Release Characteristics of Fission Gases with Spent Fuel Burn-up during the Voloxidation and OREOX Processes (사용후핵연료의 연소도 변화에 따른 산화 및 OREOX 공정에서 핵분열기체 방출 특성)

  • Park, Geun-Il;Cho, Kwang-Hun;Lee, Jung-Won;Park, Jang-Jin;Yang, Myung-Seung;Song, Kee-Chan
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.1
    • /
    • pp.39-52
    • /
    • 2007
  • Quantitative analysis on release behavior of the $^{85}Kr\;and\;^{14}C$ fission gases from the spent fuel material during the voloxidation and OREOX process has been performed. This thermal treatment step in a remote fabrication process to fabricate the dry-processed fuel from spent fuel has been used to obtain a fine powder The fractional release percent of fission gases from spent fuel materials with burn-up ranges from 27,000 MWd/tU to 65,000 MWd/tU have been evaluated by comparing the measured data with these initial inventories calculated by ORIGEN code. The release characteristics of $^{85}Kr\;and\;^{14}C$ fission gases during the voloxidation process at $500^{\circ}C$ seem to be closely linked to the degree of conversion efficiency of $UO_2\;to\;U_3O_8$ powder, and it is thus interpreted that the release from grain-boundary would be dominated during this step. The high release fraction of the fission gas from an oxidized powder during the OREOX process would be due to increase both in the gas diffusion at a temperature of $500^{\circ}C$ in a reduction step and in U atom mobility by the reduction. Therefore, it is believed that the fission gases release inventories in the OREOX step come from the inter-grain and inter-grain on $UO_2$ matrix. It is shown that the release fraction of $^{85}Kr\;and\;^{14}C$ fission gases during the voloxidation step would be increased as fuel burn-up increases, ranging from 6 to 12%, and a residual fission gas would completely be removed during the OREOX step. It seems that more effective treatment conditions for a removal of volatile fission gas are of powder formation by the oxidation in advance than the reduction of spent fuel at the higher temperature.

  • PDF

THE ELECTROMAGNETIC CHARACTERISTICS OF THE POLAR IONOSPHERE DURING A MODERATELY DISTURBED PERIOD (지자기교란시 극전리층의 전자기적인 특성)

  • 안병호
    • Journal of Astronomy and Space Sciences
    • /
    • v.12 no.2
    • /
    • pp.216-233
    • /
    • 1995
  • The distributions of the ionospheric conductivities, electric potential, ionospheric currents, field-aligned currents, Joule heating rate, and particle energy input rate by auroral electrons along with the characteristics of auroral particle spectrum are examined during moderately disturbed period by using the computer code developed by Kamide et al. (1981) and the ionospheric conductivity model developed by Ahn et al. (1995). Since the ground magnetic disturbance data are obtained from a single meridian chain of magnetometers (Alaska meridian chain) for an extended period of time (March 9 - April 27, 1978), they are expected to present the average picture of the electrodynamics over the entire polar ionosphere. A number of global features noted in this study are as follows: (1) The electric potential distribution is characterized by the so-called two cell convection pattern with the positive potential cell in the morning sector extending into the evening sector. (2) The auroral electrojet system is well developed during this time period with the signatures of DP-1 and DP-2 current systems being clearly discernable. It is also noted that the electric field seems to play a more important role than the ionospheric conductivity the conductivity over the poleward half of the westward electrojet in the morning sector while the conductivity enhancement seems to be more important over its equatorward half. (3) The global field-aligned current distribution pattern is quite comparable with the statistical result obtained by Iijima and Potemra (1976). However, the current density of Region 1 is much higher than that of Region 2 current at pointed out by pervious studies (e.g.; Kamide 1988). (4) The Joule heating occurs over a couple of island-like areas, one along the poleward side of the westward electrojet region in the afternoon sector. (5) The maximum average energy of precipitating electrons is found to be in the morning sector (07∼08 MLT) while the maximum energy flux is registered in the postmidnight sector (02 MLT). Thus auroral brightening and enhancement of ionospheric conductivity during disturbed period seem to be more closely associated with enhancement of particle flux rather than hardening of particle energy.

  • PDF

Microbiological Study using Monitoring of Microorganism in Salt-Fermented Fishery Products (젓갈류에서의 위생지표 미생물 및 식중독균 모니터링을 통한 미생물학적 연구)

  • Lee, Sun-Mi;Lim, Jong-Mi;Kim, Ki-Hyun;Cho, Soo-Yeol;Park, Kun-Sang;Sin, Yeong-Min;Cheung, Chi-Yeun;Cho, Joon-Il;You, Hyun-Jeong;Kim, Kyu-Heon;Cho, Dae-Hyun;Lim, Chul-Ju;Kim, Ok-Hee
    • Journal of Food Hygiene and Safety
    • /
    • v.23 no.3
    • /
    • pp.198-205
    • /
    • 2008
  • In this study, microbial investigation is accomplished for 554 Jeot-kal samples(102 of Jeot-kal, 448 of Seasoned Jeot-kal and 4 of Sik-khe, respectively) that corresponds with Coliform-bacteria, Escherichia coli, Aerobic live bacteria as hygienic indicator microorganisms, and Staphylococcus aureus, Vibrio parahaemolyticus as Food-borne pathogenic microorganisms, Based on the methods in Korea Food Code, reliable data are obtained as follows; in 31.9% rate of the samples, Coliform bacteria are verified in the extent of $0{\sim}20,000$ CFU/g as 2.3 logCFU/g. Especially, Seasoned Jeot-kal(37.7%,2.3 logCFU/g) are detected to 6 and 2 folds higher than those of Jeot-kal, 5.9% and 1.4 logCFU/g. Likewise, Escherichia coli is detected from 9 samples only in Seasoned Jeot-kal, that includes seasoned squid, seasoned octopus, seasoned roe of pollack, seasoned large-eyed herring and seasoned hairtail. Aerobic live bacteria are also detected in the range of $0{\sim}8.9{\times}10^8CFU/g$. Against salinity, E. coli are detected in samples only less than 10% salinity. Concomitantly, aerobic live bacteria count is decreased to $5.5{\sim}3.6$ log CFU/g upon the salinity is increased up to 25%. However, S. aureus and V. parahaemolyticus are not detected in 554 samples, presumptively referring Jeot-kal products are somehow free from such food-borne pathogens. As the results above, we deliberately consider that the sanitary control in Jeot-kal, which be necessarily fermented- as well as non-microbially inactivated should be ensured in near future and also suggest an effectual microbial standard corresponding to the Negativity in E. coli for Jeot-kal products.

A Study on Requirement and Degree of the Satisfaction about Cosmeceuticals of Women (우리나라 여성들의 기능성화장품에 대한 요구 및 만족도 연구)

  • Kim Kang-Mi;Kim Ju-Duck
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.30 no.4 s.48
    • /
    • pp.571-582
    • /
    • 2004
  • Recently the well-being, which is regarded as the new cultural code, has brought a new change in the cosmetic industry. The application of the functional products is getting mere and lots of functional cosmetics are now diversifying from the skin-care into the make-up as well as the herbal products. So the future in the market of functional cosmetic products is prospected to be positive. Therefore, cosmetic companies need an approach bases on the concept of the well-being. So to speak, they need to understand the needs of customers accurately from the customers point of view. Also it is a crucial issue that how the unique characteristics of functional cosmetic products as well as the development of products base on the concept of well-being make in balance. In this study, we attempt to inspect the advanced domestic market of the functional products due to the well-being trend and try to propose an option of making an advance it through the customers survey (for example, their need and their satisfaction on the functional products, etc) on the functional cosmetic products. For this purpose, it has been surveyed on adult female customers aged 19 to 60 located in Seoul and Gyeonggi province. 379 questionnaires among 510 were used in the final analysis. Collected data was analyzed using the statistical package for the social science (SPSS) program that can give the information about the general characteristics of the subjects like the frequency and percentage. And we used Cronbach's u reliability test, $x^2\;(chi-square)$ frequency analysis, t-test, and one-wat ANOVA to investigate the customers need, their degree of the satisfaction on the functional products of their own, factors of their perception on the quality on them. We think that the results of our study can act not only as the fundamental data on the customers need, their usage pattern, and their degree of the satisfaction, but also as the important tips of planning the marketing strategies.

Monte Carlo Simulations of Detection Efficiency and Position Resolution of NaI(TI)-PMT Detector used in Small Gamma Camera (소형 감마카메라 제작에 사용되는 NaI(TI)- 광전자증배관 검출기의 민감도와 위치 분해능 특성 연구를 위한 몬테카를로 시뮬레이션)

  • Kim, Jong-Ho;Choi, Yong;Kim, Jun-Young;Im, Ki-Chun;Kim, Sang-Eun;Choi, Yeon-Sung;Joo, Kwan-Sik;Kim, Young-Jin;Kim, Byung-Tae
    • Progress in Medical Physics
    • /
    • v.8 no.2
    • /
    • pp.67-76
    • /
    • 1997
  • We studied optical behavior of scintillation light generated in NaI(TI) crystal using Monte Carlo simulation method. The simulation was performed for the model of NaI(TI) scintillator (size: 60 mm ${\times}$ 60 mm ${\times}$ 6 mm) using an optical tracking code. The sensitivity as a function of surface treatment (Ground, Polished, Metal-0.95RC, Polished-0.98RC, Painted- 0.98RC) of the incident surface of the scintillator was compared. The effects of NaI(TI) scintillator thickness and the refractive index of light guide optically coupling between the NaI(TI) scintillator and photomultiplier tube (PMT) were simulated. We also evaluated intrinsic position resolution of the system by calculating the spread of scintillation light generated. The sensitivities of the system having the surface treatment of Ground, Polished, Metal-0.95RC, Polished-0.98RC and Painted-0.98RC were 70.9%, 73.9%, 78.6%, 80.1% and 85.2%, respectively, and the surface treatment of Painted-0.98RC allowed the highest sensitivity. As increasing the thickness of scintillation crystal and light guide, the sensitivity of the system was decreased. As the refractive index of light guide increases, the sensitivity was increased. The intrinsic position resolution of the system was estimated to be 1.2 mm in horizontal and vertical directions. In this study, the performance of NaI(TI)-PMT detector system was evaluated using Monte Carlo simulation. Based on the results, we concluded that the NaI(TI)-PMT detector array is a favorable configuration for small gamma camera imaging breast tumor using Tc-99m labeled radiopharmaceuticals.

  • PDF

Reliability Based Stability Analysis and Design Criteria for Reinforced Concrete Retaining Wall (신뢰성(信賴性) 이론(理論)에 의한 R.C.옹벽(擁壁)의 안정해석(安定解析) 및 설계규준(設計規準))

  • Cho, Tae Song;Cho, Hyo Nam;Chun, Chai Myung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.3 no.3
    • /
    • pp.71-86
    • /
    • 1983
  • Current R.C. retaining wall design is bared on WSD, but the reliability based design method is more rational than the WSD. For this reason, this study proposes a reliability based design criteria for the cantilever retaining wall, which is most common type of retaining wall, and also proposes the theoretical bases of nominal safety factors of stability analysis by introducing the reliability theory. The limit state equations of stability analysis and design of each part of cantilever retaining wall are derived and the uncertainty measuring algorithms of each equation are also derived by MFOSM using Coulomb's coefficient of the active earth pressure and Hansen's bearing capacity formula. The levels of uncertainties corresponding to these algorithms are proposed appropriate values considering our actuality. The target reliability indices (overturning: ${\beta}_0$=4.0, sliding: ${\beta}_0$=3.5, bearing capacity: [${\beta}_0$=3.0, design for flexure: [${\beta}_0$=3.0, design for shear: ${\beta}_0$=3.2) are selected as optimal values considering our practice based on the calibration with the current R.C. retaining wall design safety provisions. Load and resistance factors are measured by using the proposed uncertainties and the selected target reliability indices. Furthermore, a set of nominal safety factors, allowable stresses, and allowable shear stresses are proposed for the current WSD design provisions. It may be asserted that the proposed LRFD reliability based design criteria for the R.C. retaining wall may have to be incorporated into the current R.C. design codes as a design provision corresponding to the USD provisions of the current R.C. design code.

  • PDF

The Study on Musculoskeletal Symptoms and it's Related Factors in Radio-Technologists (방사선사의 근골격계 증상과 유해 요인에 관한 연구)

  • Lee, Hyang-Seob;Han, Man-Seok
    • Journal of radiological science and technology
    • /
    • v.31 no.3
    • /
    • pp.239-247
    • /
    • 2008
  • In order to study the occurrence of symptoms of musculoskeletal disorders of radio-technologists employed at metropolitan general hospitals and the factors that influence such occurrence, standardized questionnaire by NIOSH that was modified and supplemented to be suitable for conditions in Korea was used. Answers collected from 143 radio-technologists in two weeks from June 13, 2007 were analyzed and the results are as follows. Factor that influence symptoms of musculoskeletal disorders by area were analyzed through multiple logistic regression analysis and the results found that in the neck area, risk increased as the burdening work category 2(Korea ministry of labor)(OR=3.94) and burdening work category 9(Korea ministry of labor)(OR=4.72) increased. In the shoulder region, risk increased as burdening work category 2(Korea ministry of labor)(OR=5.36), burdening work category 7(Korea ministry of labor)(OR=3.90), and burdening work category 9 (Korea ministry of labor)(OR=5.76) increased. In the arm/hand/wrist regions, risk increased as burdening work category 2 (Korea ministry of labor) (OR=6.91), and burdening work category 9 (Korea ministry of labor)(OR=3.76) increased. In the lower back region, risk increased as burdening work category 2 (Korea ministry of labor) (OR=3.06), and burdening work category 8 (Korea ministry of labor)(OR=8.14) increased. In the leg/knees/foot regions, risk increased as burdening work category 2 (Korea ministry of labor) (OR=3.63), and burdening work category 9 (Korea ministry of labor)(OR=2.96) increased. Conclusively, in factors that influence musculoskeletal disorder symptoms in radio-technologists, influence of subjective health conditions, total work experience, experience in current division, and burdening work category 2, 7, 8, and 9 (Korea ministry of labor) were most significant. Therefore, for preventive management, in addition to ergonomic and educational intervention for correcting improper posture during work, efforts for break time adjustment and stress reduction is needed, and encouragement and support for regular exercise is needed.

  • PDF

Evaluation of Microbiological Safety of Food Service Environment in Child Care Centers (어린이집 급식환경의 미생물학적 안전성 평가)

  • Lee, Han-Cheol;Jun, Se-Young;Ha, Heon-Ho;Song, Ju-Seok;Lee, Young-Ju;Kim, Jung-Beom
    • Journal of Food Hygiene and Safety
    • /
    • v.35 no.2
    • /
    • pp.146-151
    • /
    • 2020
  • This study investigated microbiological safety of employees' hands, dining tables, and indoor air in cooking areas and lunchrooms in child care centers. Microbiological tests were performed according to the Korea Food Code. Total numbers of aerobic bacteria and coliform bacteria were measured as 5.8±1.9 log CFU/hand and 4.0±2.4 log CFU/hand on employees' hands, and 4.3±3.0 log CFU/100 ㎠ and 2.6±3.3 log CFU/100 ㎠ on dining tables. Bacillus cereus were detected in two cases each of employees' hands and dining tables, respectively. The analysis of microbiological contamination of indoor air in chid care centers showed that the total numbers of aerobic bacteria and coliform bacterial were 28±7.2 CFU/plate and 3.1±2.9 CFU/plate, respectively. Bacillus cereus and Staphylococcus aureus were counted as 1.7±0.2 CFU/plate and 1.6±0.5 CFU/plate from the indoor air in child cate centers. These results indicate that indoor-air in child care centers is considered more safe compared to previous reports. In conclusion, it is necessary to carry out hygienic management using alcohol-based disinfectants before meals to remove microorganism contamination on dining tables and hands. In order to reduce microbial contamination in indoor air, it is also deemed necessary to freshen the sanitary caps, masks, and clothing of the catering staff with periodic ventilation of indoor air.

Empirical Research on the R&D Investment and Performance of Venture Businesses (벤처기업의 R&D 투자와 성과에 관한 실증연구)

  • Lee, D.K.;Lee, C.K.;Kim, J.H.
    • 한국벤처창업학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.179-208
    • /
    • 2008
  • In this research, an empirical analysis was performed to determine the correlation between management performance and R&D investment for domestic venture businesses in each industry. Specifically, an empirical analysis for each industry was attempted not only to clarify the general hypothesis on the relationship between management performance and R&D investment for venture businesses but also to demonstrate that differences exist for each industry. Empirical analysis was conducted for eight industries with respect to the $2002{\sim}2006$ panel data extracted as investigative results from the "Investigation Report on Science and Technology R&D Activities" published by the Ministry of Science and Technology. Industrial classification was limited to the middle-level classification (2-digit) in the Korea Standard Industry Code (KSIC) owing to the limited number of panels. Although this research only verified the overall positive effect of R&D activities and funds for existing research on corporate value or productivity and management performance, it was able to document the difference for each individual industry and each business size unlike existing research.Furthermore, the reliability of the research results was enhanced by targeting companies that have been continuously conducting R&D and management activities using consistent 5-year panel data in the analysis. Again, this was something that existing research did not have. Finally, through the use of recent data from 2002 after the IMF economic crisis up to 2006 in the empirical analysis, this research proposed the problems due to the prevailing circumstances at the time of entering the advanced nation stage based on an empirical analysis; the prevailing problems during the pursuit of advanced nation status before the IMF crisis broke out were not tackled. The key empirical analysis yielded several results. First, capital and size of the labor force have a positive correlation with the management performance for the entire company or the venture business. This applies to all eight industries as the subjects of the analysis. Second, although the number of years since a company has been established can have positive or negative correlation with management performance for the entire company or venture business in specific industries, a definite overall trend cannot be identified. Third, R&D investment can be said to have an overall positive effect on corporate management performance. Fourth, the size of the research staff cannot be said to be a factor unilaterally affecting the management performance of the entire company or the venture business. Fifth, the number of years a research institute has been in operation, which was assumed to have a positive effect on the management performance of a company because of the accumulated R&D know-how -- definitely acts as a positive factor contributing to the management performance of a company.

  • PDF

The Development of Air-kerma Strength Calculation Algorithm in Terms of the Absorbed Dose to Water for HDR Ir-192 Source (기준점에서의 물 흡수선량을 이용한 Ir-192 선원의 공기커마 세기 계산을 위한 알고리즘 개발)

  • Huh, Hyun-Do;Kim, Woo-Chul;Loh, John-Jk;Lee, Suk;Lee, Sang-Hoon;Cho, Sam-Ju;Shin, Dong-Oh;Choi, Jin-Ho;Kwon, Soo-Il;Kim, Seong-Hoon
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.232-237
    • /
    • 2006
  • The aim of this study was to develop the calculation algorithm of source strength of Ir-192 source In terms of the absorbed dose to water instead of an apparent activity (Ci). For this work the Multi Purpose Brachytherapy Phantom(MPBP) was developed, which was designed to locate the source and the chamber precisely at a specific position Inside the water phantom. The reference point of measurement was set at the 5 cm distance along the transverse axis of the source. For a brachytherapy source calibration, the absorbed dose to water calibration factor ($N_{D.W.Q}$) of an lonization chamber were determined and then apply standard protocols of absorbed dose to water. The calibration factor ($N_{D.W.Q}$) of the ion chamber (TM30013, PTW, Germany) was determined using the EGSnrcCPP Monte Carlo Code. The calculated calibration factor ($N_{D.W.Q}$) was 5.28 cGy/nC. The calculated factor was then used to determine the absorbed dose to water from which the air kerma strength for an Ir-192 source can be easily derived at the reference point (5 cm). The calculated air kerma strength showed discrepancies of -0.6% to +1.8% relative to the air kerma strength provided by the vendor, In this work we demonstrated that the air kerma strength ($S_k$) could be determined from the absorbed dose to water calibration factor for Ir-192 source. In audition, this source calibration method could be applied directly to the dose Calculation formalism of AAPM report TG-43.

  • PDF