• Title/Summary/Keyword: Korean Body Information

Search Result 2,860, Processing Time 0.038 seconds

Influence of Positional Changes of Arms and Legs to Electrocardiogram

  • Song, Joo-Eun;Song, Min-Ju;Kim, Ye-Sul;Yang, Ha-Nuel;Lee, Ye-Jin;Jung, Dongju
    • Biomedical Science Letters
    • /
    • v.24 no.1
    • /
    • pp.43-49
    • /
    • 2018
  • Electrocardiogram (ECG) is a widely used method to diagnose electrical activity of heart. Although it is a reliable and easy method, ECG could be interfered by electrical signals. One of the interfering signals is electromyogram (EMG) that is caused by muscle contraction in any parts of the body except heart. To avoid the EMG noise, an examinee is advised to be relaxed on supine position while measuring ECG. Sometimes, patients who can't put their arms and legs down on bed due to some reasons such as cast on arms or legs necessarily have the EMG noise. But detailed information about how much of the noise could be induced by positional change of arms and legs has not been reported. Here we examined the noise by analyzing ECG data from 14 candidates, 7 males and 7 females. The ECG data was obtained using the standard 12 lead ECG. EMG noise was induced by raising arms and legs at $90^{\circ}$, $60^{\circ}$ or $30^{\circ}$. Because arms are located close to the heart, noise by the raised arms was analyzed toward left or right arm separately. All of the examinees showed similar pattern of the EMG noise. EMG noise by positional change of left or right arm was clearly monitored in different limb leads. Change of leg positions induced the noise that was monitored in aVF of augmented leads and II and III of limb leads. There was a difference in degree of the noise between male and female examinees. In addition to the EMG noise, decrease of PR interval was monitored in particular positional changes, which was prominent in male examinees. These results will enlarge fundamental understanding about EMG noise in ECG.

A Methodology of Decision Making Condition-based Data Modeling for Constructing AI Staff (AI 참모 구축을 위한 의사결심조건의 데이터 모델링 방안)

  • Han, Changhee;Shin, Kyuyong;Choi, Sunghun;Moon, Sangwoo;Lee, Chihoon;Lee, Jong-kwan
    • Journal of Internet Computing and Services
    • /
    • v.21 no.1
    • /
    • pp.237-246
    • /
    • 2020
  • this paper, a data modeling method based on decision-making conditions is proposed for making combat and battlefield management systems to be intelligent, which are also a decision-making support system. A picture of a robot seeing and perceiving like humans and arriving a point it wanted can be understood and be felt in body. However, we can't find an example of implementing a decision-making which is the most important element in human cognitive action. Although the agent arrives at a designated office instead of human, it doesn't support a decision of whether raising the market price is appropriate or doing a counter-attack is smart. After we reviewed a current situation and problem in control & command of military, in order to collect a big data for making a machine staff's advice to be possible, we propose a data modeling prototype based on decision-making conditions as a method to change a current control & command system. In addition, a decision-making tree method is applied as an example of the decision making that the reformed control & command system equipped with the proposed data modeling will do. This paper can contribute in giving us an insight of how a future AI decision-making staff approaches to us.

Low-power Lattice Wave Digital Filter Design Using CPL (CPL을 이용한 저전력 격자 웨이브 디지털 필터의 설계)

  • 김대연;이영중;정진균;정항근
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.10
    • /
    • pp.39-50
    • /
    • 1998
  • Wide-band sharp-transition filters are widely used in applications such as wireless CODEC design or medical systems. Since these filters suffer from large sensitivity and roundoff noise, large word-length is required for the VLSI implementation, which increases the hardware size and the power consumption of the chip. In this paper, a low-power implementation technique for digital filters with wide-band sharp-transition characteristics is proposed using CPL (Complementary Pass-Transistor Logic), LWDF (Lattice Wave Digital Filter) and a modified DIFIR (Decomposed & Interpolated FIR) algorithm. To reduce the short-circuit current component in CPL circuits due to threshold voltage reduction through the pass transistor, three different approaches can be used: cross-coupled PMOS latch, PMOS body biasing and weak PMOS latch. Of the three, the cross-coupled PMOS latch approach is the most realistic solution when the noise margin as well as the energy-delay product is considered. To optimize CPL transistor size with insight, the empirical formulas for the delay and energy consumption in the basic structure of CPL circuits were derived from the simulation results. In addition, the filter coefficients are encoded using CSD (Canonic Signed Digit) format and optimized by a coefficient quantization program. The hardware cost is minimized further by a modified DIFIR algorithm. Simulation result shows that the proposed method can achieve about 38% reductions in power consumption compared with the conventional method.

  • PDF

A study on the schematic organization of the sub-classification system of the Taeeumin symptomatology (태음인(太陰人) 병증(病證) 분류(分類)에 관한 연구(硏究))

  • Lee, Jun-Hee;Lee, Eui-Ju;Koh, Byung-Hee
    • Journal of Sasang Constitutional Medicine
    • /
    • v.23 no.1
    • /
    • pp.63-78
    • /
    • 2011
  • 1. Objectives: We aimed to propose a sub-classification system for the Taeeumin symptomatology by examining the Taeeumin pathology and symptomatology descriptions appearing in "Donguisusebowon". 2. Methods: The Gabo Edition and the Sinchuk Edition (the upgraded and revised edition) of "Donguisusebowon" were reviewed and examined for relevant information on the Taeeum pathology and symptomatology. 3. Results and Conclusions: 1) In the Taeeumin symptomatology, the Exterior disease develops from the basic pathology of Esophagus-Cold and the Interior disease from that of Liver-Heat, eventually progressing to damage of the expirational and dispersive energy of the Lung Sector, the Prime Core Organ or the excessively small organ of the Taeeum constitutional type. The resulting pathology can be broadly defined as the "Lung-Dryness symptomatology". 2) The case reports introduced in the Exterior disease section, including the Zhang Zhongjing Mahuang-tang treatment, Prolonged-affliction disease treatment, and Exterior disease Pestilential disease treatment, share several points in common. They all arise from the pathology of "weakness in the Lung sector and deficiency in the Exterior sector", and they can all be assigned to the same symptomatological division that presents with systemic heat and cold intolerance; this symptomatology can be defined as the "Esophagus-Cold symptomatology", the milder subdivision of the exterior symptomatology. 3) The body of text appearing in the last part of the Interior disease section commonly referred to as the "Taeeumin Conspectus" is in fact not a conspectus when its contents are actually examined. Instead, it can be understood from its pathological and symptomatological descriptions that the passage is explaining the more severe subdivision of the exterior symptomatology that has progressed from Esophagus-Cold to a pathology characterized by damaged expirational and dipersive energy of the Lung Sector. 4) The relocation of the "dry-related pathology" indicates a change in perspective regarding the "Dry-related symptomatology", which caused the rearrangement of the Interior disease into divisions of Liver-Heat symptomatology that is characterized by fulminant heat pathology and Dry-Heat symptomatology that is also accompanied by Lung-Dryness. 5) The Interior disease Yin-Blood Consumptive symptomatology should be included in the Dry-Heat symptomatology in the pathological scheme. 6) Based on the above, the subdivisions of the Taeeumin symptomatology should be arranged as "Esophagus-Cold symptomatology" and "Lung-Dry-Cold symptomatology" in the Exterior disease and "Liver-Heat symptomatology" and "Dry-Heat symptomatology" in the Interior disease.

Early Life History of Black Bullhead, Pseudobagrus koreanus(Pisces, Bagridae), from Kum River, Korea (금강에 서식하는 눈동자개 Pseudobagrus koreanus(Pisces, Bagridae)의 초기 생활사)

  • Kang, Eon-Jong
    • Korean Journal of Ichthyology
    • /
    • v.10 no.2
    • /
    • pp.184-190
    • /
    • 1998
  • The early life history of black bullhead, Pseudobagrus koreanus, endemic to Korea was investigated to get biological information needed in artificial production of seedlings and in recovering natural resources. The fertilized eggs showed some characteristics in having heavy sticky material and minute folds which is formed radical pattern on the egg membrane. The shape of egg was spherical and $2.59{\pm}0.08$(2.45~2.70, n=10)mm in diameter. The yolk had not oil globule. The first cleavage was observed 2 hrs after insemination at $21{\sim}23^{\circ}C$, and the progressive cleavage were done about 30 min. interval. The characteristic changing of the yolk surface started at morula stage and continued to the end of gastrula. Hatching was started 72 hrs and completed 90 hrs after fertilization. The size of the larvae were 5.41~5.81mm in total length and 2.76~2.94mm in preanal length, and the number of so mites was 15-16+33~34(48~50). The barbels and swimbladder were completed and all the fins except second dorsal were appeared 1 week after hatching. The larvae attained 9.67~10.52mm in total length and 5.20~5.65mm in preanal length. All the fin sets and color pattern were completed 2 weeks after hatching and body mucus was secreted at that stage. The juvenile attained 14.59~16.02mm in standard length, 3.31~4.16mm in head length and 8.07~9.31mm in prenal length.

  • PDF

The Implementation of Digital Neural Network with identical Learning and Testing Phase (학습과 시험과정 일체형 신경회로망의 하드웨어 구현)

  • 박인정;이천우
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.36C no.4
    • /
    • pp.78-86
    • /
    • 1999
  • In this paper, a distributed arithmetic digital neural network with learning and testing phase implemented in a body has been studied. The proposed technique is based on the two facts; one is that the weighting coefficients adjusted will be stored in registers without shift, because input values or input patterns are not changed while learning and the other is that the input patterns stored in registers are not changed while testing. The proposed digital neural network is simulated by hardware description language such as VHDL and verified the performance that the neural network was applied to the recognition of seven-segment. To verify proposed neural networks, we compared the learning process of modified perceptron learning algorithm simulated by software with VHDL for 7-segment number recognizer. The results are as follows: There was a little difference in learning time and iteration numbers according to the input pattern, but generally the iteration numbers are 1000 to 10000 and the learning time is 4 to 200$\mu\textrm{s}$. So we knew that the operation of the neural network is learned in the same way with the learning of software simulation, and the proposed neural networks are properly operated. And also the implemented neural network can be built with less amounts of components compared with board system neural network.

  • PDF

Development of Nitrogen Cooling Equipment for Personalized Local Area (개인 맞춤형 국소부위 질소 냉각 장비 개발)

  • Lee, Young-Ji;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.24 no.3
    • /
    • pp.913-916
    • /
    • 2020
  • In this paper, we propose the development of nitrogen cooling equipment for personalized local area. The proposed equipment consists of a cold air supply module, a body, and nitrogen injection with the following characteristics. First, it automatically controls the amount and time of cold air supply by utilizing information measuring skin temperature with volumetric temperature sensors, so it can have a competitive edge in function by ensuring complete safety. Second, if the distance measuring sensor is applied to the skin for more than a certain distance, it can block the cold air or control the discharge of nitrogen in conjunction with the control GUI to improve the efficiency of higher cooling therapy while providing safe management. Third, by installing a control module that can control the supply of nitrogen, the cost of maintenance can be minimized by minimizing the loss of nitrogen. Experiments at an external testing agency to evaluate the performance of the proposed equipment showed that the accuracy of the temperature sensor was measured in the range of ±3.8%, which is lower than the world's highest level(±5%), with a range of 110℃ to -160℃ similar to the world's highest level. Distance accuracy was measured in the range of ±3.0%, lower than the world's highest level(±5%), and weight accuracy in the range of ±0.1%, lower than the world's highest level(±5%). In addition, emission control was measured in four stages, higher than the world's highest level(stage 1) and nitrogen use was measured at 0.8L/min below the world's highest(6L/min). Therefore, the effectiveness of the methods proposed in this paper was demonstrated because they produced the same results as the world's highest levels.

Development of Life Test Equipment with Real Time Monitoring System for Butterfly Valves

  • Lee, Gi-Chun;Choi, Byung-Oh;Lee, Young-Bum;Park, Jong-Won;Nam, Tae-Yeon;Song, Keun-Won
    • International Journal of Fluid Machinery and Systems
    • /
    • v.10 no.1
    • /
    • pp.40-46
    • /
    • 2017
  • Small valves including ball valves, gate valves and butterfly valves have been adopted in the fields of steam power generation, petrochemical industry, carriers, and oil tankers. Butterfly valves have normally been applied to fields where in narrow places installing the existing valves such as gate valves and ball valves have proven difficult due to the surrounding area and the heavier of these valves. Butterfly valves are used to control the mass flow of the piping system under low pressure by rotating the circular disk installed inside. The butterfly valve is benefitted by having simpler structure in which the flow is controlled by rotating the disc circular plate along the center axis, whereas the weight of the valve is light compared to the gate valve and ball valve above-mentioned, as there is no additional bracket supporting the valve body. The manufacturing company needs to acquire the performance and life test equipment, in the case of adopting the improving factors to detect leakage and damage on the seat of the valve disc. However, small companies, which are manufacturing the industrial valves, normally sell their products without the life test, which is the reliability test and environment test, because of financial and manpower problems. Furthermore, the failure mode analysis of the products failed in the field is likewise problematic as there is no system collecting the failure data on sites for analyzing the failures of valves. The analyzing and researching process is not arranged systematically because of the financial problem. Therefore this study firstly tried to obtain information about the failure data from the sites, analyzed the failure mode based on the field data collected from the customers, and then obtained field data using measuring equipment. Secondly, we designed and manufactured the performance and life test equipment which also have the real time monitoring system with the naked eye for the butterfly valves. The concept of this equipment can also be adopted by other valves, such as the ball valve, gate valve, and various others. It can be applied to variously sized valves, ranging from 25 mm to large sized valves exceeding 3000 mm. Finally, this study carries out the life test with square wave pressure, using performance and life test equipment. The performance found out that the failures from the real time monitoring system were good. The results of this study can be expanded to the other valves like ball valves, gate valves, and control valves to find out the failure mode using the real time monitoring system for durability and performance tests.

A Breed Comparison on the Finishing Times of Racehorses (국내 경주마의 주파기록에 대한 품종별 비교 분석)

  • Kong, Hong-Sik;Lee, Hak-Kyo;Park, Kyung-Do;Cho, Byung-Wook
    • Journal of Animal Science and Technology
    • /
    • v.53 no.1
    • /
    • pp.23-27
    • /
    • 2011
  • This study was conducted to provide basic information for the improvement of racing performance of Jeju pony & Halla horse, using the 85,732 racing records collected from Jeju & Kwacheon racecourses from January 1, 2005 to December 31, 2009. During the last 5 years, a total of 2,892 heads of horses were racing at the Jeju racecourse and 11.7% (338 heads) of them were Jeju ponies. The average body weight of Jeju pony and Halla horse were 267 kg & 287 kg, respectively, which were 58% and 62% of that of Thoroughbred (460 kg). The repeatabilities of Jeju pony, Halla horse and Thoroughbred for finishing time were estimated in the range of 0.26-0.66 (average, 0.54), 0.34-0.68 (average, 0.56) and 0.37-0.60 (average, 0.50), respectively, and as the racing distance increased, the repeatabilities decreased. In the racing distance of 1,000 m, the differences in the finishing times between Thoroughbred & Jeju pony, Thoroughbred & Halla horse, and Jeju pony & Halla horse were 24.33 seconds, 10.81 seconds and 13.52 seconds, respectively. The racing performance of Halla horse was improved by 55.6% than that of Jeju pony at the 1,000 m race.

Outcomes of small for gestational age micropremies depending on how young or how small they are

  • Yu, Hee-Joon;Kim, Eun-Sun;Kim, Jin-Kyu;Yoo, Hye-Soo;Ahn, So-Yoon;Chang, Yun-Sil;Park, Won-Soon
    • Clinical and Experimental Pediatrics
    • /
    • v.54 no.6
    • /
    • pp.246-252
    • /
    • 2011
  • Purpose: The outcomes of small for gestational age (SGA) infants especially in extremely low birth weight infants (ELBWIs) are controversial. This study evaluated the mortality and morbidity of ELBWIs, focusing on whether or not they were also SGA. Methods: The medical records of 415 ELBWIs (birth weight<1,000 g), who were inborn and admitted to the Samsung Medical Center neonatal intensive care unit from January 2000 to December 2008, were reviewed retrospectively. Mortality and morbidities were compared by body size groups: very SGA (VSGA), birth weight ${\leq}$3rd percentile; SGA, 3rd to 10th percentile; and appropriate for gestational age (AGA) infants, >10th percentile for gestational age. For gestational subgroup analysis, groups were divided into infants with gestational age ${\leq}24^{+6}$ weeks (subgroup I), $25^{+0}$ to $26^{+6}$ weeks (subgroup II), and ${\geq}27^{+0}$ weeks (subgroup III) Results: Gestational age was $29^{+2}{\pm}2^{+6}$ weeks in the VSGA infants (n=49), $27^{+5}{\pm}2^{+2}$weeks in the SGA infants (n=45), and $25^{+4}{\pm}1^{+4}$ weeks in AGA infants (n=321). Birth weight was $692{\pm}186.6$ g, $768{\pm}132.9$ g, and $780{\pm}142.5$ g in the VSGA, SGA, and AGA groups, respectively. Cesarean section rate and maternal pregnancy-induced hypertension were more common in the VSGA and SGA than in AGA pregnancies. However, chorioamnionitis was more common in the AGA group. The mortalities of the lowest gestational group (subgroup I), and also of the lower gestational group (subgroup I+II) were significantly higher in the VSGA group than the SGA or AGA groups (P=0.020 and P=0.012, respectively). VSGA and SGA infants showed lower incidence in respiratory distress syndrome, ductal ligation, bronchopulmonary dysplasia, intraventricular hemorrhage than AGA group did. However, by multiple logistic regression analysis of each gestational subgroup, the differences were not significant. Conclusion: Of ELBWIs, extremely SGA in the lower gestational subgroups, had an impact on mortality, which may provide information useful for prenatal counseling.