• Title/Summary/Keyword: Knife radiosurgery

Search Result 161, Processing Time 0.03 seconds

Development of De Novo Cavernous Hemangioma after Radiosurgery for Cavernous Hemangioma

  • Yeon, Je-Young;Suh, Yeon-Lim;Kim, Jong-Hyun;Lee, Jung-Il
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.6
    • /
    • pp.532-533
    • /
    • 2010
  • We report a rare case of cavernous hemangioma (CH) which developed in adjacent location to a preexisting CH after gamma knife radiosurgery (GKRS). A 36-year-old woman underwent GKRS for a CH in the left lentiform nucleus. Three-and-half years after radiosurgery, MRI revealed a new CH in the left caudate nucleus. Surgical excision of the new lesion was performed. The pathological examination confirmed the diagnosis of CH. In radiosurgery for CH, it should be noted that a new CH may develop, which is likely to result from the interaction between radiation and predisposing factors of the patient.

Gamma Knife Radiosurgery in Patients with a Hypothalamic Hamartoma Associated with Intractable Gelastic Epilepsy : Report of Three Cases

  • Ko, Che-Kyu;Hong, Seok-Ho;Ko, Tae-Sung;Lee, Jung-Kyo
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.1
    • /
    • pp.58-60
    • /
    • 2006
  • Hypothalamic hamartoma[HH] is an unusual nonneoplastic developmental lesion associated with gelastic epilepsy and precocious puberty, mostly found in children. Although open surgery has been attempted when antiepileptic medication failed to control seizures, its deep location and surrounding vital structures often rendered surgery unsuccessful. We describe the outcome of gamma knife radiosurgery in three children with a HH associated with gelastic epilepsy and reviewed the literature for a possible therapeutic mechanism.

Therapeutic Effect of Gamma Knife Radiosurgery for Multiple Brain Metastases

  • Lee, Chul-Kyu;Lee, Sang-Ryul;Cho, Jin-Mo;Yang, Kyung-Ah;Kim, Se-Hyuk
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.3
    • /
    • pp.179-184
    • /
    • 2011
  • Objective : The aim of this study is to evaluate the therapeutic effects of gamma knife radiosurgery (GKRS) in patients with multiple brain metastases and to investigate prognostic factors related to treatment outcome. Methods : We retrospectively reviewed clinico-radiological and dosimetric data of 36 patients with 4-14 brain metastases who underwent GKRS for 264 lesions between August 2008 and April 2011. The most common primary tumor site was the lung (n=22), followed by breast (n=7). At GKRS, the median Karnofsky performance scale score was 90 and the mean tumor volume was 1.2 cc (0.002-12.6). The mean prescription dose of 17.8 Gy was delivered to the mean 61.1% isodose line. Among 264 metastases, 175 lesions were assessed for treatment response by at least one imaging follow-up. Results : The overall median survival after GKRS was $9.1{\pm}1.7$ months. Among various factors, primary tumor control was a significant prognostic factor ($11.1{\pm}$1.3 months vs. $3.3{\pm}2.4$ months, p=0.031). The calculated local tumor control rate at 6 and 9 months after GKRS were 87.9% and 84.2%, respectively. Paddick's conformity index (>0.75) was significantly related to local tumor control. The actuarial peritumoral edema reduction rate was 22.4% at 6 months. Conclusion : According to our results, GKRS can provide beneficial effect for the patients with multiple (4 or more) brain metastases, when systemic cancer is controlled. And, careful dosimetry is essential for local tumor control. Therefore, GKRS can be considered as one of the treatment modalities for multiple brain metastase.

CYBERKNIFE RADIOSURGERY FOR INOPERABLE RECURRED ORAL CANCER (사이버나이프를 이용한 수술 불가능한 재발성 구강암의 치험례)

  • Kim, Yong-Kack;Lee, Tae-Hee;Kim, Chul;Kim, Sung-Jin;Kim, Hyuk
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.30 no.1
    • /
    • pp.65-68
    • /
    • 2004
  • CyberKnife is a stereotactic radiosurgery system which could be used to treat many tumors and lesions. It provides the surgeon unparalleled flexibility in targeting using a compact light linear accelerator mounted on a robotic arm. Advanced image guidance technology tracks patient and target position during treatment, ensuring accuracy without the use of an invasive head frame. CyberKnife with Dynamic Tracking Software is cleared to provide radiosurgery for lesions anywhere in the body when radiation treatment is indicated. It has often been used to radiosurgically treat otherwise untreatable tumors and malformations. Moreover, this instrument treats tumors at body sites, most of which are unreachable by other stereotactic systems. Compared with conventional radiotherapy, it is fundamentally different that using non-invasive, frameless, no excessive radiation exposure to normal tissue. In oral malignant neoplasm, surgical excision and radiation therapy should be tried first, additionally chemotherapy could be considered. However, after failure of conventional therapies, patients had poor systemic condition and surgical limitation. So, CyberKnife could be a suitable therapy. A 49 years man was referred in recurred mandibular cancer treated by radiotherapy. The tumor was considered inoperable, because of extensive invasion and was not expected to good response to conventional therapies. We experienced a case of CyberKnife after 4 cycle chemotherapies, so we report it with review of literature.

A Case of Rapid Cycling Secondary Mania after Gamma-knife Radiosurgery (감마나이프 방사선수술 후 발생한 급속 순환성 이차성 조증 1예)

  • Chung, Chan-Ho;Chae, Jeong-Ho;Kim, Im-Ryol;Lee, Chung-Kyoon;Lee, Kyu-Hang
    • Korean Journal of Biological Psychiatry
    • /
    • v.3 no.2
    • /
    • pp.302-308
    • /
    • 1996
  • A case of rapid cycling mania secondary to gamma-knife radiosurgery for the treatment of refractory epilepsy was reported. A 21-year old woman who had a gamma-knife radiosurgical operation for the treatment of refractory seizure two years ago was admitted because of manic episodes. Although seizure was relieved, manic symptoms like decreased need for sleep, elated mood, unprovoked laughing, grandiose delusion and bizarre behaviors were developed 11 months after the operation. These symptoms recurred lour rimes for eight months. There were no past personal and family history of mood disorders. Laboratory examinations including electroencephalogram ana endocrinological study did not show any abnormal findings. The rapid cycling secondary manic was relieved by lithium. She was then discharged after 5 months. Mood change was not significant during follow-up while hypomania emerged by dose reduction. The secondary mania seemed to be caused or triggered by the right temporal lobe damage induced by gamma-knife radiosurgery.

  • PDF

Avoiding a Collision in Gamma Knife Radiosurgery : A Modified Mask Fixation Method

  • Hyeong Cheol Moon;Doheui Lee;Byung Jun Min;Young Gyu Kim;Yun-Sik Dho
    • Journal of Korean Neurosurgical Society
    • /
    • v.66 no.4
    • /
    • pp.476-481
    • /
    • 2023
  • Objective : The latest version of the Leksell Gamma Knife IconTM allows for mask- and frame-based fixation. Although mask fixation provides fractionated treatment and immobilization using a noninvasive method, it is not free from collision. The authors investigated the collision problem with a modified mask fixation method. Methods : This study presents a case of two meningiomas in the frontal area, where a collision occurs in the occipital area. A modified mask fixation method was introduced to avoid the collision : first, the edges of the head cushion were cut off and polystyrene beads with a diameter of approximately 5 cm were removed. Next, the head cushion was sealed using a stapler. Finally, the head cushion was flattened in the adapter. We compared the shot coordinates, 3-dimensional (3D) error, clearance distance, and vertical depth of the head cushion between the initial and modified mask fixations. Results : When comparing the initial and modified mask fixations, the difference in the shot coordinates was +10.5 mm along the y-axis, the difference in the 3D error was approximately 18 mm, and the difference in clearance was -10.2 mm. The head cushion was approximately 8 mm deeper in the modified mask fixation. Conclusion : Based on these findings, we recommend a modified mask fixation method for gamma knife radiosurgery using ICON with a collision.

Evaluation on the Usefulness of Lung Tumor Stereotactic Radiosurgery Applying the CyberKnife $Synchrony^{TM}$ Respiratory Tracking System (사이버나이프 $Synchrony^{TM}$ 호흡 추적 장치를 이용한 폐종양 방사선수술의 유용성 평가)

  • Kim, Gha-Jung;Bae, Seok-Hwan;Choi, Jun-Gu;Chae, Hong-In
    • Journal of radiological science and technology
    • /
    • v.33 no.4
    • /
    • pp.379-386
    • /
    • 2010
  • This study evaluated the motion of tumors during the entire period of therapy and the accuracy of radiosurgery among forty eight lung tumor patients who were underwent radiosurgery using the CyberKnife Synchrony Respiratory Tracking System. The motion of lung tumor was measured by the coordinates of a gold acupuncture needle inserted into the tumor or the area around the tumor using the CyberKnife image guided system. Then the accuracy of radiosurgery was evaluated based on the error of correlation computed with the motion tracking system. The lung tumor motion is Cranio-Caudal direction by an average of $2.63{\pm}1.87\;mm$, moved left-right direction by $1.13{\pm}0.71\;mm$, and anterior-posterior direction by $1.74{\pm}1.16\;mm$. The degree of rotational movement was $1.66{\pm}1.66^{\circ}$ on X axis, $1.20{\pm}0.97^{\circ}$ on Y axis, and $1.18{\pm}0.73^{\circ}$ on Z axis. The vector of translation movement was measured to be $3.78{\pm}2.00\;mm$ on the average. The results show that directions of Cranio-Caudal(p < 0.001), anterior-posterior direction(p < 0.029), and three dimensional vector value(p < 0.002) showed statistical significance, because the lower side of tumor showed more intensive movement compared to the upper side of tumor. The radiosurgery was carried out by compensating the motion of tumor after accurate investigation of the correlation error with the average of $0.95{\pm}0.62\;mm$ during the lung tumor radiosurgery with the CyberKnife Synchrony Respiratory Tracking System.

Gamma Knife Radiosurgery for Vestibular Schwannomas

  • Lim, Young-Jin;Choi, Seok-Keun
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.3
    • /
    • pp.159-167
    • /
    • 2007
  • Vestibular schwannoma (VS) is a benign tumor typically originated in the schwann cell of vestibular nerve and usually accompany hearing symptom. Microsurgical removal and radiosurgery have a great role for the treatment of VS. Recently radiosurgery has been considered as an alternative or primary treatment for VS with the tremendous increase of patients who were treated with gamma knife radiosurgery (GKS) though microsurgery still takes the premier. By many published results, it is proved that GKS is a effective and noninvasive technique for VS, especially small sized tumors with satisfactory tumor control rate. The authors assumed that GKS can be expected to achieve satisfactory tumor control rate for small VS under 5cc in volume. A major interest regarding radiosurgery nowadays is to determine the optimal radiation dose for hearing preservation to improve the quality of life of patients. The more high radiation dose are used for effective tumor growth control, the more radiation-related complications like as hearing deficit, the impairment of other cranial nerve function are increased. Since 1990's the mean radiation dose for tumor margin was more than 18 Gy, but there were high complication rate in spite of good tumor growth control. After the year of 2000, under the influence of advanced neuro-imaging techniques and radiosurgical planning system which enable clinicians to do more precise planning, marginal dose for VS has been decreased to 12-13 Gy and the radiation-related complications has been reduced. But because there may be a unexpected radiation induced complications as time goes by after the latency period, optimal radiation dose for VS should be established on the basis of more long term follow-up observation.

Evaluation of Real-time Measurement Liver Tumor's Movement and $Synchrony^{TM}$ System's Accuracy of Radiosurgery using a Robot CyberKnife (로봇사이버나이프를 이용한 간 종양의 실시간 움직임 측정과 방사선수술 시 호흡추적장치의 정확성 평가)

  • Kim, Gha-Jung;Shim, Su-Jung;Kim, Jeong-Ho;Min, Chul-Kee;Chung, Weon-Kuu
    • Radiation Oncology Journal
    • /
    • v.26 no.4
    • /
    • pp.263-270
    • /
    • 2008
  • Purpose: This study aimed to quantitatively measure the movement of tumors in real-time and evaluate the treatment accuracy, during the treatment of a liver tumor patient, who underwent radiosurgery with a Synchrony Respiratory motion tracking system of a robot CyberKnife. Materials and Methods: The study subjects included 24 liver tumor patients who underwent CyberKnife treatment, which included 64 times of treatment with the Synchrony Respiratory motion tracking system ($Synchrony^{TM}$). The treatment involved inserting 4 to 6 acupuncture needles into the vicinity of the liver tumor in all the patients using ultrasonography as a guide. A treatment plan was set up using the CT images for treatment planning uses. The position of the acupuncture needle was identified for every treatment time by Digitally Reconstructed Radiography (DRR) prepared at the time of treatment planning and X-ray images photographed in real-time. Subsequent results were stored through a Motion Tracking System (MTS) using the Mtsmain.log treatment file. In this way, movement of the tumor was measured. Besides, the accuracy of radiosurgery using CyberKnife was evaluated by the correlation errors between the real-time positions of the acupuncture needles and the predicted coordinates. Results: The maximum and the average translational movement of the liver tumor were measured 23.5 mm and $13.9{\pm}5.5\;mm$, respectively from the superior to the inferior direction, 3.9 mm and $1.9{\pm}0.9mm$, respectively from left to right, and 8.3 mm and $4.9{\pm}1.9\;mm$, respectively from the anterior to the posterior direction. The maximum and the average rotational movement of the liver tumor were measured to be $3.3^{\circ}$ and $2.6{\pm}1.3^{\circ}$, respectively for X (Left-Right) axis rotation, $4.8^{\circ}$ and $2.3{\pm}1.0^{\circ}$, respectively for Y (Crania-Caudal) axis rotation, $3.9^{\circ}$ and $2.8{\pm}1.1^{\circ}$, respectively for Z (Anterior-Posterior) axis rotation. In addition, the average correlation error, which represents the treatment's accuracy was $1.1{\pm}0.7\;mm$. Conclusion: In this study real-time movement of a liver tumor during the radiosurgery could be verified quantitatively and the accuracy of the radiosurgery with the Synchrony Respiratory motion tracking system of robot could be evaluated. On this basis, the decision of treatment volume in radiosurgery or conventional radiotherapy and useful information on the movement of liver tumor are supposed to be provided.

Gamma Knife Radiosurgery for Craniopharyngioma (두개인두종에 대한 감마나이프 방사선수술)

  • Chang, Jong Hee;Chang, Jin Woo;Park, Yong Gou;Chung, Sang Sup
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.5
    • /
    • pp.561-566
    • /
    • 2001
  • Objective : The purpose of this study are to evaluate the effectiveness of Gamma Knife radiosurgery(GKS) as a treatment of craniopharyngioma and to investigate the proper dose planning technique in GKS for craniopharyngioma. Method : Between May 1992 and March 1999, seven Gamma Knife radiosurgical procedures were done for residual tumor mass of 6 patients with craniopharyngioma after microsurgical resection. Conventional radiation therapy was not performed. In this study, their clinical, radiological and radiosurgical data were analyzed and the radiation dosage to the optic pathway, hypothalamus, pituitary stalk, and cavernous sinus were calculated and correlation with clinical outcome was evaluated. The mean follow-up period was 33.5 months(12.3-55.2 months). Result : The mean tumor volume was 4.4cc(0.4-18.0cc) and the maximum radiation dose ranged from 14 to 32 Gy(mean 20.9Gy). The radiation was given with isodose curve, 50-90% and the marginal dose varied within 8-22.4Gy(mean 12.7Gy). The mean number of isocenter was 4.3(1-12). The tumor was well controlled in all cases. In 5 of 7 cases, the size of tumor decreased to 10-50% of pre-GKS volume and remaining two showed no volume change. The mean dose to optic pathway was 5.7Gy(5.1-11.2Gy) and there were no complications. Conclusion : GKS seems to be effective for control of craniopharyngioma as an adjuvant treatment after microsurgical resection and even suboptimal dose for tumor margin is considered to be enough for tumor control. It is safe with careful dose planning to protect surrounding important structures, especially optic pathway. We believe conventional radiation therapy should be avoided because it has limitation for dose planning of additional treatments such as radiosurgery or intracystic instillation of radioisotope in case of recurrence.

  • PDF