• 제목/요약/키워드: Knee protection

검색결과 40건 처리시간 0.026초

동작 가변적 3D 프린팅 충격보호패드의 설계 (Design of motion-adaptable 3D printed impact protection pad)

  • 박정현;이진숙;이정란
    • 복식문화연구
    • /
    • 제30권3호
    • /
    • pp.403-413
    • /
    • 2022
  • The purpose of this study was to develop a 3D mesh-type impact protection pad with excellent motion adaptability and functionality by applying 3D printing technology. The hexagonal 3D mesh, which constitutes the basic structure of the pad, comprises two types: small and large. The bridge connecting the basic units was designed as the I-type, V-type, IV-type, and VV-type. After evaluating the characteristics of the bridge, it was found that the V-type bridge had the highest flexibility and tensile elongation. The hip joint pad and knee pad were completed by combining the hexagonal 3D mesh structure with the optimal bridge design. The impact protection pad was printed using a fused deposition modeling-type 3D printer with a filament made of thermoplastic polyurethane material, and the protection pad's performance was evaluated. When an impact force of approximately 6,500N was applied to the pad, the force attenuation percentage was 78%, and when an impact force of approximately 8,000N was applied, the force attenuation percentage was 75%. Through these results, it was confirmed that the 3D-printed impact protection pad with a hexagonal 3D mesh structure connected by a V-shaped bridge developed in this study can adapt to changes in the body surface according to movement and provides excellent impact protection performance.

흰쥐에서 MIA로 유발된 골관절염에 선방활명음 가미방이 미치는 영향 (Effects of Sunbanghwalmyung-Eum Gamibang on MIA-Induced Osteoarthritis in Rats)

  • 신유빈;박한별;김재수;이현종;임성철;이윤규
    • Korean Journal of Acupuncture
    • /
    • 제39권4호
    • /
    • pp.152-171
    • /
    • 2022
  • Objectives : This study was designed to investigate the effects of Sunbanghwalmyung-eum gamibang on Monosodium iodoacetate-induced osteoarthritis rats. Methods : Forty Sprague-Dawley (SD) rats were divided into 5 groups of 8 rats each. Osteoarthritis (OA) was induced by injecting MIA (2 mg/50 µl) into the joint cavity of the left knee of SD rats belonging to the experimental group, and normal saline was injected into the joint cavity of the left knee instead of MIA in the normal group. To the normal group and the controlled group (OA group), 2 ml of distilled water was orally administered. To the positive control group (Indomethacin group), indomethacin 2 ml at a concentration of 2 mg/kg, to the low concentration group of SHG (Low group), 2 ml of SHG at a concentration of 2 mg/kg, and to the high concentration group of SHG (High group), 2 ml of SHG at a concentration of 4 mg/kg ml was orally administered. The drug was administered for a total of 4 weeks, and histological changes were analyzed by Hematoxylin-Eosin staining and Safranin-O staining. In addition, inflammatory cytokines such as TNF-α, IL-1β, and IL-6, and MMP-13, TIMP-1, and GAGs were immunohistochemically analyzed. Finally, hematological examination, blood biochemical examination, and liver and kidney biopsy were performed. Results : SHG groups (Low and High) inhibited the matrix destruction and damage of the knee joint cartilage in SD rat model, and significantly prevented the reduction in cartilage thickness. In SHG groups, the expressions of TNF-α, IL-1β, IL-6 and MMP-13 were significantly decreased, and the expressions of TIMP-1, GAGs were significantly increased compared with OA group. The safety indicators had no significant differences among five groups. Conclusions : These results show that SHG has cartilage protection capacity, anti-inflammatory effect.

세가지 생약복합추출물, AIF의 연골 및 뼈 보호 효능 (Cartilage and Bone Protection Effect of AIF, a water extract from three herbs)

  • 장순화;이병의;정동식;한정현;박정애;심성보;김세원;김정근
    • 생약학회지
    • /
    • 제39권1호
    • /
    • pp.1-6
    • /
    • 2008
  • AIF has been formulated using three herbs known to have anti-inflammatory and anti-osteolytic effects. In this study, the potential therapeutic effects of AIF for osteoarthritis were assessed in vitro and in vivo. The effects of AIF on the cartilage and bone protection (MMP-13 expression, GAG degradation, OPG release) were examined, in vitro. In addition, the therapeutic effect of AIF was evaluated using a chemical-induced osteoarthritis rat model. Rats were injected with iodoacetate intraarticularly in one knee joint and treated with the oral administration of 100 mg/kg AIF-glucosamine once a day for 3 weeks. And then, destruction of cartilage and bone was evaluated by histopathological assessment. AIF significantly inhibited the production of MMP13 and GAG in a dose dependent manner in vitro. Also, AIF increased the production of OPG. In OA rat model, the AIF-glucosamine treated group reduced cartilage destruction, compared to vehicle or glucosamine treated group. AIF showed potent protective effects for the destruction of cartilage and bone, in vitro and in vivo. These results suggest that AIF contains effective compound(s) which may modify the progression of arthritis.

여성노인의 낙상실태 및 충격보호팬츠 개발을 위한 기초 연구 (Basic Study on the Development of Impact Protective Pants and Falls of Elderly Women)

  • 이진숙;박정현;이정란
    • 한국의류산업학회지
    • /
    • 제16권6호
    • /
    • pp.945-953
    • /
    • 2014
  • This study aims to develop protective pants to relieve impact from falls and to present basic data for the development. The survey results are as follows; First, 45% of the respondents were in their 60s and 55% of them were in their over 70s and older. Also, 64% of them have fallen once for the past year and 36% of them have fallen twice or more. The older they were, the more there were those who have fallen twice or more. This indicated the older people has experienced more fall accidents again after a initial fall accident. Second, as per accident situations, the survey showed that fall accidents happened the most in the winter and in the afternoon (12-18 pm). Also, it happened on a street mostly and they were wearing sneakers or hiking boots when they got a hurt slipped in a front or side by missing their step in a walk. The injury areas are mostly knee and ankle. They had the bruises or a sprain in their knee and ankle mostly. The rate of bone fracture was 19.5%. Therefore, the protection area to falls in lower body is the knee. But hip and hip joint should be protected with knee as well because those are usually be broken when it is damaged. Third, approximately 80% of those who were hospitalized for treatment had surgery. Patients who had surgery were rather in their over 70s than in their 60s. The older they were, the more serious their fracture was. The period of hospital or outpatient treatment is more than three weeks in many cases. They responded their health got worse after falls. Aftereffects of accidents were physical discomfort, anxiety and medical costs. Falls to the old makes physical damage, psychological damage, which cause reduced physical activity and the increased cost of health care with economic losses. So it results on a negative impact on the life of the old. Fourth, elderly females were rarely aware of impact protective clothing and they have never purchased such clothing. For impact protective pants, the major consideration was suitable design for their body types. They liked casual style with front or side pockets and simple designs without any patterns or decorations. As per pants materials, they responded that they need functionality, activity and elasticity. Among the functional points, insulation of cloths are considered importantly, so the heat reservance of material in the impact protective pants should be considered carefully.

국산자동차의 보행자 보호를 위한 머리모형 충격시험 (Headform Impact Test for Pedestrian Safety using Domestic Vehicles)

  • 용부중;김시우;윤경한
    • 한국자동차공학회논문집
    • /
    • 제16권4호
    • /
    • pp.8-13
    • /
    • 2008
  • Since hundreds thousands of pedestrians are killed or injured in car accidents every year, a variety of research efforts have been performed to protect pedestrians in pedestrian-vehicle crashes. The IHRA reports that injuries on the child head, the adult head, and the adult lower leg/knee are the most critical in the crashes. Identifying the current status of international activities on pedestrian protection, this study, in particular, carries out headform impact test using selected domestic vehicles categorized by three groups - Sedan, SUV (Sport Utility Vehicle), and 1 Box (One Box) Vehicle. According to the valuable findings from the test results, this paper proposes a methodology under which the Korean Technical Regulation for protecting pedestrians in pedestrian-vehicle crashes will be developed.

흰쥐의 MIA 유발 무릎 뼈관절염에 대한 840 nm LED의 효과 (Effect of 840 nm Light-Emitting Diode(LED) Irradiation on Monosodium Iodoacetate-Induced Osteoarthritis in Rats)

  • 제갈승주;권필승;김진경;이재형
    • 대한물리의학회지
    • /
    • 제9권2호
    • /
    • pp.151-159
    • /
    • 2014
  • PURPOSE: The purpose of this study was to evaluate whether light-emitting diodes (LED) irradiation could be effective in a noninvasive, therapeutic device for the treatment of osteoarthritis(OA). METHODS: Twenty-four male Sprague-Dawley rats were divided into four groups: Vehicle control (saline); monosodium iodoacetate-injection (MIA); LED irradiation after MIA injection (MIA-LED); indomethacin-treatment after MIA injection (MIA-IMT). OA was induced by intra-articular injection of 3 mg MIA through the patellar ligament of the right knee. Vehicle control rats were injected with an equivalent volume of saline. The LED was irradiated for 15 min/day for a week after 7 days of MIA treatment. To compare with the effect of LED irradiation, the indomethacin was administrated 20 mg/kg twice a week orally after 7 days of MIA treatment. Knee joints were removed and fixed overnight in 10% neutral buffered formalin and decalcified by EDTA for 2 week before being embedded in paraffin. The assessment of OA induction were monitored by knee movement and radiographic finding. Histologic analysis were performed following staining with hematoxylin and eosin, safranin O-fast green, or toluidine blue, picrosirius red, and histologic changes were scored according to a modified Mankin system. Apoptotic cell in tissue sections was detected using TUNEL method. RESULTS: Radiographic examination could not show the differences between the MIA-treated and the MIA-LED-treated rats. In the histologic analysis, however, LED irradiation prevented cartilage damage and subchondral bone destruction, and significantly reduced mononuclear inflammatory cell infiltration and pannus formation. LED irradiation also reduced apoptosis of cartilage cells, but it prevented apoptosis of infiltrated inflammatory cells in synovium. In addition, LED irradiation showed an increase of collagen production in the meniscus. CONCLUSION: These results suggest that the 840 nm LED irradiation would be a suitable non-thermal phototherapy for the treatment of OA, as a cartilage protection and anti-inflammatory modality.

몽골여자복식의 변천 및 요인에 관한 연구 -몽골.원 제국기 복식을 중심으로- (A Study on the Transformation and Transformational Factors in Mongolian Women's Costumes -Focusing of Women's Costumes of Mongol.Yuan Era -)

  • 최해율;남윤자;조우현
    • 복식
    • /
    • 제52권4호
    • /
    • pp.111-123
    • /
    • 2002
  • The purpose of this study is to correctly understand the shaping process of Mongolian women's costumes, which had close connection with Korean costumes. 'Nomadic' factors of Mongol costumes are trousers and jacket, with deel(袍) pleated in the waistline for horse riding, and knee-covering narrow-sleeved long dress for men and women alike for protection against the cold. However, Married women wore bogthag(gogo: ) containing symbols derived from nomadic way of life. 'Foreign' factors are divided into two kinds; foreign culture applied to Mongolian costumes(woven stuff, Koryo style), and transformation in costumes to adjust to the environmental alteration owing to extended territory(pigap(比甲), Jacket and skirt), the last of which served as the chief distinction between nomadic and Y an fashions. 'Religious' factors are unique patterns and colors while retaining their symbolism. Some aspects(mongke tengri or eternal sky) of Shamanism is reflected in avoidance of washing, while positive effect of Lamanism is evidenced in yellow cosmetic applied on the forehead and 16 sky devil dance clothes.dance clothes.

이중고리 동종 아킬레스건을 이용한 후방십자인대 재건 - 예비 보고 - (Anatomic Double-Bundle Posterior Cruciate Ligament Reconstruction Using Achilles Allograft - Preliminary Report -)

  • 임홍철;유재철;한상환
    • 대한관절경학회지
    • /
    • 제6권1호
    • /
    • pp.7-13
    • /
    • 2002
  • 목적 : 후방십자인대 손상과 치료에 대한 기전과 처치 및 재건에 대한 여러 가지 술식이 보고되고 있다. 이에 본 저자들은 후방십자인대 손상 환자에서 이중 고리 아킬레스 동종이식건을 이용한 후방십자인대 재건술을 보고하고자 한다. 대상 및 방법 : 1999년 5월부터 2000년 7월까지 본원 정형외과학 교실에서 수술한 후방십자인대 손상 8명을 대상으로 하였다. 이들은 모두 아킬레스 동종이식건으로 만든 두 개의 건 다발을 이용하여 대퇴골측은 대퇴골 이중 터널(dual femoral tunnel) 방법으로 고정하였고, 경골측은 한 개의 터널로 고정하는 관절경적 후방십자인대 재건술을 시행하였다. 수술 후 1년 이상 추시 관찰하였으며, 결과는 Lysholm Knee Score와 KT-2000관절 계측기를 이용한 도수 최대 전위 검사법으로 건측과 비교하여 안정성 여부 및 기능을 평가하였다. 결과 : 후방십자인대 재건술을 시행 받은 8명을 1년 이상 추시한 결과 이식건 파열이 관찰되었던 한 례를 제외하고는 불안정성을 보이지 않았다. 술 후 감염 등의 중대한 합병증을 보이는 환자는 없었으며 다만 한 예에서 술 중 이식골의 골절이 있었고 다른 한 예에서 술 후 부적절한 보호로 인한 이식건의 파열을 관찰할 수 있었다. 결론 : 후방십자인대 손상에 대한 아킬레스 동종이식건으로 만든 두 개의 건 다발을 이용한 대퇴골 이중 터널 고정술은 이전의 방법들에 비해 생역학적으로 안정적인 방법으로 간주되나 보다 장기적인 추시 관찰 결과가 필요할 것으로 사료된다.

  • PDF

사회인 야구 참여자의 야구복 개발에 관한 연구 (A Development of Baseball Uniforms for Social Baseball Players)

  • 김예진;김은경;유은주
    • 한국의류산업학회지
    • /
    • 제17권5호
    • /
    • pp.800-814
    • /
    • 2015
  • This study develops baseball uniforms for amateur baseball players with excellent appearance and functional movement. This study selected a conventional baseball uniform and developed a new one for amateur baseball players with improved function and appearance based on previous research results. In case of developed baseball uniform materials, this study used polyurethane mixed fabric for the top to improve flexibility. A mesh material was used at the armpit, back, and bottom of the top, side line of pants and pockets to improve breathability. In addition, quilted material was added to the knee to improve durability and protection. For the patterns and design, this study used a gusset under the arm to assist in comfortable movement as well as reduced the length of the top and circumference of the hem to decrease unnecessary parts. For the pants, this study used a waistband gripper to avoid the top riding up, added darts behind the knees to bend comfortably, and added additional fabric inside the hem to prevent dirt. In addition, we reduced the width and length of the pants. Wearing evaluation was divided into appearance evaluation by experts and on-site-wearing test by baseball players. The wearing evaluation results for the developed baseball uniform indicated higher evaluations than a conventional baseball uniform in all sections as well as showed significant differences in all sections. The result of movement adaptability evaluation showed the highest satisfaction for 'the top does not ride up' and 'dirt do not get in'.

중·고등학생의 교복 착용 실태와 만족도 비교 (Comparison of Actual Status and Satisfaction of School Uniform between Middle and High School Students)

  • 이지민;이정란;구영석
    • 한국의류산업학회지
    • /
    • 제11권5호
    • /
    • pp.753-763
    • /
    • 2009
  • The purpose of this study was to investigate the wearing situation and satisfaction of school uniforms with the middle and high school boys and girls, who have been in uniforms for one or more years. The subjects for the survey were a total of 560 from the 2nd and the 3rd grade of the middle school, and the 1st and the 2nd grade of the high school. The survey was performed with the questionnaire of 60 questions; 36 questions related to the actual status, such as the purchase, size, repair, and design of a school uniform, and 24 questions related to satisfaction. The results were as follows; 1. Regarding the school uniform purchase, middle school students attached importance to famous brand, while high school students valued design above everything else. The students confused with the school uniform sizing systems were 82.1 % and 72.5 % in middle and high school students. 2. 43% of middle school students and 34% of high school students had experiences of repairing their school uniforms. Regarding the reason for repair, the size misfit was the highest. Boys preferred a single breasted boxy jacket with middle hip line length, and straight trousers, and girls preferred a fitted jacket of waist line length, and flare skirt of the knee line length. 3. School uniform satisfaction score showed that students were not satisfied with their school uniforms so much. Middle school students had significantly lower satisfaction about the design and psychological protection than high school students. Even though high school students showed lower satisfaction about the price and the care of school uniforms, there were no significant differences between them.